Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: TPI Corporation
Description: 120 V 1-PHASE INPUT SUPPLY RATING 1300 CFM FLOW RATE EXHAUST FAN GABLE MOUNT MOUNTING TYPE MOTOR DRIVE TYPE APPROVAL UL SIZE 15 INCH DIA X 6 INCH D
- Air Flow Rate: 1,300 SCFM
- Applications / Use: Exhaust Ventilation
- Draft: Induced Draft
-
Supplier: Greenheck
Description: Wall Exhaust Fans The Wall Exhaust Fans include both direct and belt driven fans with backward inclined centrifugal wheels. The motors on the fans are out of the airstream. The fans are suitable for sidewall applications. CW, CWB Models CW/CWB
- Air Flow Rate: 70 to 12,500 SCFM
- Static Pressure: 5 in H2O
- Applications / Use: Air Handling Units / HVAC, Exhaust Ventilation
- Material of Construction: Aluminum
-
Supplier: LTG Incorporated
Description: LTG centrifugal fans in the exhaust series are used mainly to extract combustion gases from industrial plants. Their special design makes them suitable for conveying media of up to 392 °F and volumetric flows of up to 10 005 cfm. They can also be used for other tasks involving high
- Air Flow Rate: 706 to 10,595 SCFM
- Static Pressure: 1.164245118985443 to 2.368636621384175 in H2O
- Applications / Use: Air Handling Units / HVAC, Exhaust Ventilation
- Product Form: Bare (No Motor, Controls)
-
-
Supplier: Continental Fan Manufacturing, Inc.
Description: RMD axial exhaust fans are suitable for roof or wall mounting, and are the perfect low cost choice for areas that have little or no duct-work. RMD fans are easy to install, corrosion resistant and feature a totally enclosed ball bearing motor. RMD fans are
- Air Flow Rate: 173 to 2,400 SCFM
- Media Temperature: 110 F
- Maximum Diameter (Fan or Blower Wheel): 10 to 18 inch
- Material of Construction: Aluminum, Steel
-
Supplier: Fläkt Woods Group SA
Description: Suitable for most medium volume, medium-high pressure applications. Typically used for commercial kitchen exhaust due to motor out of airstream and ease of cleaning. The fan is equipped with a high efficiency CentriflowPlus Impeller and the motor can be controlled with a
- Air Flow Rate: 5,720.9814 SCFM
- Static Pressure: 4.416102175462009 in H2O
- Media Temperature: 248 F
- Maximum Diameter (Fan or Blower Wheel): 0.9842525 to 1.968505 inch
-
Supplier: Cincinnati Fan
Description: Proof (ODP), Totally Enclosed (TEFC or TENV), or EXP (explosion proof) motors, models with explosion proof motors utilize cast aluminum propellers are standard. Features: Heavy-duty steel panels. 12"-20" fans have 16 gauge panels, 24"-30" fans have 14 gauge panels and
- Air Flow Rate: 38,650 SCFM
- Static Pressure: 407.5371674924572 in H2O
- Media Temperature: 104 F
- Maximum Diameter (Fan or Blower Wheel): 48 inch
-
Supplier: Thermon, Inc
Description: Specifically designed for both hazardous and general purpose industrial applications, the Ruffneck™ EFX Explosion-Proof Exhaust Fan is built for safety and durability. A number of optional features are available for customization, including Heresite® coating on all non-motor
- Maximum Diameter (Fan or Blower Wheel): 12 to 30 inch
- Material of Construction: Aluminum, Steel
- Design: Axial
- AMCA Class: Class I, Class II
-
Supplier: National Fan Company
Description: Stainless Steel Exhaust Fan : 24 in blade - 1/2 HP - 115 / 230V (5,200 CFM) Variable Speed GENERAL INFORMATION: "TF" series stainless steel circulating panel fans are designed for use as air tube circulators, exhaust and chimney or circulating fans for hog,
- Air Flow Rate: 5,200 SCFM
- Maximum Diameter (Fan or Blower Wheel): 24 inch
- Applications / Use: Exhaust Ventilation
- Product Form: Packaged (Complete System)
-
Supplier: HVACQuick.com
Description: Canarm/Leader P Series Direct Drive Panel Exhaust Fans. 12 Inch, 1100 nominal CFM, Low Noise, Single Speed, 115V, 1 phase Panel exhaust fan, sturdily constructed, direct drive, horizontal discharge for industrial, commercial and farm applications. Durable powder coat
-
Supplier: HVACQuick.com
Description: other commercial and industrial buildings. Heavy duty aluminum housing with built in shutters. Aluminum shutters automatically open when fan starts, close when fan stops. Heavy duty OSHA motor mount/guard is standard. Motors are totally enclosed, continuous run,
-
Supplier: National Fan Company
Description: Panel Exhaust Fan Explosion Proof: 12 in blade (1,640 CFM) * PLEASE CALL OUR OFFICE FOR PRICING ON 3 PHASE MOTOR Fans are sturdily constructed, direct drive, horizontal discharge for industrial, commercial and farm applications. FEATURES: •Explosion proof motors
- Air Flow Rate: 1,640 SCFM
- Maximum Diameter (Fan or Blower Wheel): 12 inch
- Applications / Use: Exhaust Ventilation
- Features: Explosion Proof, Wall / Panel Mount
-
Supplier: Twin City Fan & Blower
Description: Application The TCPE Propeller Wall Fan is designed for low static pressures and can be mounted in a wall vertically or in a ceiling horizontally. All units come standard with a spun galvanized panel (except explosion proof, which is aluminum), zinc plated motor mount/guard, custom
- Air Flow Rate: 390 to 7,615 SCFM
- Static Pressure: 407.4121674924572 in H2O
- Maximum Diameter (Fan or Blower Wheel): 8 to 24 inch
- Applications / Use: Air Handling Units / HVAC, Exhaust Ventilation
-
Supplier: Hartzell Air Movement
Description: sound and air performance. Accessories include explosion-proof, chemical-duty or other special motors; disconnect switch; bird screen; fiberglass damper; and more. Additional features: FRP construction Direct Drive: Motors have extended shafts Belt Drive: Motors are totally
- Static Pressure: 0 to 3 in H2O
- Maximum Diameter (Fan or Blower Wheel): 12 to 18 inch
- Drive Type: Belt Drive, Direct Drive
- Features: Explosion Proof, Other
-
Supplier: Pelonis Technologies, Inc.
Description: PTGA series Axial Exhaust Fans are designed to provide optimal airflow and efficiency for residential and commercial applications. Each fan housing and impeller are made of high-quality UV resistant ABS material and also includes an innovative blade design that maximizes airflow
- Static Pressure: 0.2 in H2O
- Applications / Use: Air Handling Units / HVAC, Exhaust Ventilation
- Environment: Clean Air / Gas
- Drive Type: Direct Drive
-
Supplier: Allied Electronics, Inc.
Description: Features: AC Fans with Round Venturi Housing Shallow Depth with External Rotor Motor for Exceptional Performance and Long Life Individual Sickle Blades Made of Sheet Steel Are Welded onto the External-Rotor Motor and Dynamically Balanced Direction of Rotation Is CCW Looking at
-
Supplier: Twin City Fan & Blower
Description: deep spun venturi. The wheel, motor and drive assembly are completely isolated from the fan supports by rubber isolators to reduce transmission of noise and vibration. The top cap also provides complete protection for the motor and drive assembly, while allowing quick access to
- Air Flow Rate: 585 to 11,600 SCFM
- Static Pressure: 410.0371674924572 in H2O
- Maximum Diameter (Fan or Blower Wheel): 12.25 to 31.5 inch
- Drive Type: Belt Drive
-
Supplier: Twin City Fan & Blower
Description: backward inclined centrifugal wheel precisely matched to a deep spun venturi. The wheel, motor and drive assembly are completely isolated from the fan supports by rubber isolators to reduce transmission of noise and vibration. The top cap also provides complete protection for the
- Air Flow Rate: 585 to 11,600 SCFM
- Static Pressure: 410.0371674924572 in H2O
- Maximum Diameter (Fan or Blower Wheel): 12.25 to 31.5 inch
- Drive Type: Belt Drive
-
Supplier: Twin City Fan & Blower
Description: backward inclined centrifugal wheel precisely matched to a deep spun venturi. The wheel, motor and drive assembly are completely isolated from the fan supports by rubber isolators to reduce transmission of noise and vibration. The top cap also provides complete protection for the
- Air Flow Rate: 224 to 3,865 SCFM
- Static Pressure: 408.2871674924572 in H2O
- Maximum Diameter (Fan or Blower Wheel): 8.38 to 18.25 inch
- Design: Centrifugal
-
Supplier: Johnson Controls, Inc.
Description: airstream cooling for the motors and bearings. Units float on vibration isolators. Ball bearing motors, sheaves, belts and self-aligning ball bearings are all standard brands of national manufacturers. All components are selected for durability, efficiency and value. FEATURES AND
- Air Flow Rate: 39 to 17,516 SCFM
- Static Pressure: 1.5 in H2O
- Drive Type: Belt Drive, Direct Drive
- Design: Centrifugal
-
Supplier: AirPro Fan & Blower Co.
Description: AirPro’s industrial material-handling fan (IEPW) moves not only air but also material at medium-to-high static pressures. With its rugged design, this heavy-duty industrial exhaust fan is able to move heavy, sticky, and abrasive materials through the airstream without
- Air Flow Rate: 80,000 SCFM
- Static Pressure: 45 in H2O
- Media Temperature: 1,200 F
- Design: Centrifugal
-
Description: Model UBH belt drive tubeaxial exhausters are ideally suited for roof exhaust applications that require the motor, drives and bearing located out of the airstream. The high velocity upblast discharge of the UBH disperses air high above the buildings roof. Capacities range from 1757 to
- Air Flow Rate: 1,757 to 61,236 SCFM
- Applications / Use: Air Handling Units / HVAC, Exhaust Ventilation
- Design: Axial
- Drive Type: Belt Drive
-
Supplier: Cincinnati Fan
Description: RBE fan is available in all aluminum or all stainless steel construction. This fan is available in AMCA A, B, or C spark resistant construction. Features: All models available with housing and wheel widths from 50% to 100%, in 5% increments, to deliver the performance you need with a
- Air Flow Rate: 22,528 SCFM
- Static Pressure: 447.7871674924572 in H2O
- Media Temperature: 750 F
- Maximum Diameter (Fan or Blower Wheel): 41 inch
-
Supplier: Allied Electronics, Inc.
Description: Features: External Rotor Shaded-Pole Motor Impedance Protected Against Overloading Metal Fan Housing and Impeller Air Exhaust Over Struts Counterclockwise Rotation Looking at Rotor Mounting from Either Face Using Four 0.185" (4.7 mm) Holes 2.8 × 0.5 mm Flat Pin Power Terminals
-
Supplier: Loren Cook Company
Description: Restaurant Exhaust Ventilator provides maximum performance and durability in kitchen hood exhaust applications. VCR unit top cap assembly is designed to provide weather protection for the motor and drive components while maintaining easy tool free access for inspection and
- Air Flow Rate: 279 to 28,806 SCFM
- Maximum Diameter (Fan or Blower Wheel): 10 to 49 inch
- Material of Construction: Aluminum
- Design: Centrifugal
-
Supplier: Allied Electronics, Inc.
Description: Mounting is from either face using two 0.169" (4.3 mm) holes. Motor is a PSC external rotor motor. Features: All Units Have Safety Agency Approvals — See Footnotes Die Cast Aluminum Housing, Sheet Steel Impeller Ball Bearing Construction 0.110 Terminals Air Exhausts Over Struts
-
Supplier: Loren Cook Company
Description: weather protection for the motor and drive components while maintaining easy, tool free access for inspection and maintenance. Standard lifting lugs, located under the top cap, provide for safe, fast and efficient lifting of the unit to a rooftop. One piece fan base, which includes a
- Air Flow Rate: 4,300 to 11,000 SCFM
- Material of Construction: Aluminum
- Drive Type: Belt Drive, Direct Drive
- Design: Centrifugal
-
Supplier: Hartzell Air Movement
Description: from belt or direct drive models. Available in 12 sizes from 12 through 57″ wheel diameters, single-width, single-inlet construction (SWSI). Available in Class II, III and IV and narrow-width construction; Arrangement 1, 4, 8, 9, 9M or 10. Fan housings for sizes 12 through 29″ are field
- Static Pressure: 0 to 25 in H2O
- Maximum Diameter (Fan or Blower Wheel): 12 to 57 inch
- Material of Construction: Aluminum, Stainless Steel, Steel
- Design: Centrifugal
-
Supplier: Allied Electronics, Inc.
Description: Features: External Rotor Shaded-Pole Motor Die Cast Aluminum Housing Sheet-Steel Impeller Welded to Rotor Air Exhaust Over Struts Counterclockwise Rotation Looking at Rotor Mounting from Either Face Using Two 4.6 mm Holes 2.8 × 0.5 mm Flat Pin Power Terminals Capable of 50 Hz Operation
-
Supplier: Continental Blower, LLC
Description: The Continental Advantage Rugged cast iron or cast aluminum modular construction designed for continuous, dependable operation year after year Uniform delivery of pulse free, oil free air Quiet performance in compliance with OSHA regulations without the need for silencing Variable volume flow
- Air Flow Rate: 45,000 SCFM
- Material of Construction: Aluminum, Cast Iron
- Product Form: Bare (No Motor, Controls)
- Drive Type: Belt Drive, Direct Drive
-
Supplier: Enervex, Inc.
Description: Exhaust Fan with vertical discharge. The EFV is a ruggedly designed fan build in cast aluminum. The MBESV system is extremely suitable for retrofitting. Sustainable Advantages Economical. Over a 15-year period a typical demand-controlled EXHAUSTO-system serving 8 kitchen hoods
-
Supplier: Micro Air
Description: Micro Air® model SCA exhauster arms are used on a wide variety of fume and particulate exhaust applications. Designed to control airborne pollutants at their generation point, SCA arms can be equipped with a fan to vent outside, or ducted to Micro Air® air cleaners or dust collectors
- Diameter: 4 to 8 inch
- Length: 5 to 12 ft
-
Supplier: Enervex, Inc.
Description: The MFES, Multi-story Fireplace Exhaust System™ provides a perfect draft for gas-fired fireplaces exhausting into a common chimney and is essentially a variant of the CASV, Chimney Automation System. This is a well-tested, and listed, concept in mechanical venting of fireplaces in multi-story
-
Supplier: Airflow Systems, Inc.
Description: Multiple-bay facilities often resort to opening overhead doors and running fans for relief from the annoyance of vehicle exhaust. If not removed, vehicle exhaust can contribute to worker illness, increase facility maintenance expense, and harm the sensitive electronics of
- Collector Type: Wall or Column
-
Supplier: Howden
Description: Tellus Fans Howden Tellus Variable Pitch Axial Flow Fans - A uniquely designed axial fan providing operating economy, low sound power levels and reliability. When reliability and adaptability are paramount, the Tellus fan is the preferred choice for the most demanding
- Applications / Use: Air Handling Units / HVAC, Exhaust Ventilation
- Design: Axial
- Environment: Clean Air / Gas, Corrosive Gases, Dirty Air / Gas
- Product Form: Packaged (Complete System)
-
Supplier: Howden
Description: Cased axial flow fans Howden Donkin long cased axial flow fans perform under the toughest conditions. With airflow ranging from 980 to a maximum 5,750 m³/Hr there’s a Donkin HCT fan to suit your needs. We also supply the Majax-2, Maxflo Majax BIF and Vanax cased axial flow
- Air Flow Rate: 576.5634 to 3,382.8975 SCFM
- Media Temperature: -13 to 104 F
- Design: Axial
- Environment: Clean Air / Gas, Dirty Air / Gas
Find Suppliers by Category Top
Featured Products Top
-
Fuji Electric provides solutions for Exhaust Fan Systems to manage starting torque and overcome system resistance. We offer adjustable speed operation to ensure ventilation performance.
(read more)
Browse AC Motor Drives Datasheets for Fuji Electric Corp. of America -
such as health care, education, retail, hotel, manufacturing, and office, the FRENIC-MEGA (G2) is ideally suited for applications involving Air Handling Units, Supply and Return Fans, Exhaust Fans, Cooling Tower Fans, Condenser Fans, Chilled Water Pumps, Hot Water Pumps, & Pressure Boosting Pumps (read more)
Browse AC Motor Drives Datasheets for Fuji Electric Corp. of America -
Fans, Exhaust Fans, Cooling Tower Fans, Condenser Fans, Chilled Water Pumps, Hot Water Pumps, & Pressure Boosting Pumps. Follow us! Youtube (read more)
Browse AC Motor Drives Datasheets for Fuji Electric Corp. of America -
MAC 10® IQ FFU The MAC 10® IQ FFU combines advanced EC motor technology with Envirco’s proprietary baffling system and a forward curve fan to deliver intelligent, energy-efficient performance. Its electronically (read more)
Browse Air Filters (industrial) Datasheets for Envirco -
Rosenberg's EHAG Series single-inlet backward curved radial fans with electronically commutated (EC) motors can reduce energy consumption by up to 35% in many applications compared to standard AC fans. They are available in five sizes from 355 mm to 560 mm (14 to 22 inches) with (read more)
Browse HVAC Fans and Blowers Datasheets for Rosenberg USA -
change in performance. This is why Variable Frequency Drives (VFDs) are so effective. By adjusting the motor's speed to match the system's exact demands, a VFD can deliver substantial energy savings and give you precise control over your ventilation system. Centrifugal Fan (read more)
Browse Fans and Blowers (industrial) Datasheets for Hartzell Air Movement -
Fans are used in several industries and applications to move air for heat transfer, (such as convection cooling and heating), air exchange (such as ventilation and exhaust) or filtration. They typically consist of a moving element like blades or vanes, connected through a shaft to a motor that (read more)
Browse Fans and Blowers (industrial) Datasheets for Pelonis Technologies, Inc. -
and backward inclined fan, the LEDC tops the industry in energy efficiency. Its electronically commutated (EC) motor with internal microprocessor offers high performance and delivers long motor life with energy consumption rates as low as 90W @ 90 fpm. Utilizing Envirco’s experience in FFU (read more)
Browse Cleanroom Supplies and Accessories Datasheets for Envirco -
and backward inclined fan, the LEDC tops the industry in energy efficiency. Its electronically commutated (EC) motor with internal microprocessor offers high performance and delivers long motor life with energy consumption rates as low as 90W @ 90 fpm. Utilizing Envirco’s experience in FFU (read more)
Browse Fans and Blowers (industrial) Datasheets for Envirco -
Fans, Exhaust Fans, Cooling Tower Fans, Condenser Fans, Chilled Water Pumps, Hot Water Pumps, & Pressure Boosting Pumps. Follow us! Youtube (read more)
Browse Datasheets for Fuji Electric Corp. of America
Conduct Research Top
-
If Efficiency and Reliability Matter, so do Fan Motor Types
If efficiency and reliability matter, so do fan motor types. Fans are used in several industries and applications to move air for heat transfer, (such as convection cooling and heating), air exchange (such as ventilation and exhaust) or filtration. They typically consist of a moving element, like
-
LTG Tangential Fans
Tangential fans, also referred to as cross-flow fans (CFF), or cross-flow blowers, offer a uniform laminar flow pattern without the use of baffles or vanes. Extended linear air flow is exhausted across the entire length of the fans' impeller while they are characterized by their low-profile, quiet
-
Axial vs. Centrifugal Fans
Fans are used in several industries and applications to move air for heat transfer, (such as convection cooling and heating), air exchange (such as ventilation and exhaust) or filtration. They typically consist of a moving element like blades or vanes, connected through a shaft to a motor
-
Improving Energy Efficiency in Pharmaceutical Manufacturing Operations Part II: HVAC, Boilers and Cogeneration
individually, each measure may offer small savings, but combined they add up to significant savings and short payback periods. First, let s consider HVAC systems, which consist of dampers, supply and exhaust fans, filters, humidifiers, dehumidifiers, heating and cooling coils, ducts, and various
More Information Top
-
Acceptance test report for portable exhauster POR-007/Skid E
For a l l testing completed i n Section 5, if " EXHAUST FAN MOTOR " VTP-M-001 does not s t a r t when "START PUSH BUTTON" VTP-PB-IO1 i s pressed, then "STOP PUSH BUTTON" VTP-PB …
-
RELIABILITY ANALYSIS OF THE ELECTRICAL POWER DISTRIBUTION SYSTEM TO SELECTED PORTIONS OF THE NUCLEAR HVAC SYSTEM
Electrical Power Distribution from LC A and LC B to Supply and Exhaust Fan Motors (Assumption 5.7).............................................................................................
-
Exhaust Fan Motors - Grainger Industrial Supply
• Exhaust Fan Motors .
-
Plutonium Uranium Extraction Facility Documented Safety Analysis
The only remaining utilities in the PUREX compound are a skid-mounted substation that supplies power for surveillance monitoring and control, surveillance lighting, exhaust fan motors , and the water supply for the remaining three fire hydrants.
-
CR4 - Thread: 0.55 KW Single Phase Exhaust Fan Motor Cable
0.55 KW Single Phase Exhaust Fan Motor Cable .
-
Reliability centered maintenance pilot system implementation 241-AP-tank farm primary ventilation system final report
Exhaust Fan Motor , .
-
Gasification Plant Cost and Performance Optimization
… • Continental Bucket Elevator - 40 tph capacity • Primary Coal Silo - 363 Tons for 24 hour storage, 21 ft. diameter x 42 ft. cylinder height, with bottom hopper and discharge gate, top dust collector and vent, with 15 hp exhaust fan motor .
-
Mining industry process upgrades to reduce energy intensity while improving end product quality
Set the exhaust fan motor controller to maintain a nominal 3250 kW power on the fan motor and d) Closely monitor the total product moisture - this is the moisture of the recombined dryer product and by passed material, the target is 7 …
-
Ventilation Fan Fires: Overheated Windings Lead to Failed Thermal Limit Switch
A common winding failure within an exhaust fan motor caused by an electrical short between adjacent windings.
-
Energy-Efficient HVAC Design
The sources of energy consumption in this type of systems are air handling unit supply fan motor input power, return/ exhaust fan motor input power, hot water .
Indicates content that may require registration and/or purchase.