Supplier: Analytical Industries Inc.
Description: Key features Oxygen sensor compatible with: AII-2000A AII-2000M Overview USA manufactured and medical certified electrochemical galvanic oxygen sensors with excellent accuracy and stability and individually tested prior to shipment. Fresh sensors direct from
- Operating Temperature: 32 to 113 F
- Operating Humidity: 0 to 99 %
- Gas Types: Oxygen (O2)
-
Supplier: Analytical Industries Inc.
Description: Key features Very easy to operate Maintenance free oxygen Sensors 0-100% O2 range Up to 32 months sensor lifetime Integral or remote sensor options Long battery life: up to 18 months of continuous operation for AII-2000 Palm O2 Accessories also available: Case and Foam
- Instrument Type: Analyzer
- Gas Types: Oxygen (O2)
-
Supplier: Process Sensing Technologies USA
Description: Analytical Industries’ AII-2000 series or Palm O2 handheld oxygen analyzers provide a very easy way to verify oxygen and other medical gases used in medical or veterinary clinics. These FDA approved inexpensive medical gas analyzers use maintenance-free advanced galvanic
- Operating Temperature: 41 to 113 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume
- Instrument Type: Analyzer
-
-
Supplier: GasLab
Description: The AlphaSense O2-A3 oxygen sensor is a plug-in replacement sensor for hand-held gas detectors that use an O2-A3 sensor. Like other electrochemical sensors, it uses less power and has good pressure and temperature independence. Features 0.1 to 20.9% oxygen
-
Supplier: GasLab
Description: The AlphaSense O2-A2 oxygen sensor is a replacement sensor for hand-held gas detectors that use an O2-A2 sensor. Features Electrochemical (EC) sensor designed to last for up to 2 years Good pressure and temperature independence Small, compact & maintenance free The
-
Supplier: Analytical Industries Inc.
Description: Key features OEM oxygen sensor for use in: Analytical Industries Palm O2 Remote Sensor Handheld Oxygen Analyzer Overview Analytical Industries Inc. (Aii) designs and manufactures galvanic oxygen sensors for both recreational and commercial divers.
- Gas Types: Oxygen (O2)
-
Supplier: CO2Meter.com
Description: The O2-A3 Alphasense Oxygen Sensor (formerly known as the AP-0004) is a plug-in replacement sensor for hand-held gas detectors that use an O2-A3 sensor. Gaining precise oxygen measurement is critical for industries that require its use for safety, medical, air
- Features: Other
- Gas Types: Oxygen (O2)
- Number of Gases Monitored: Single Gas
-
Supplier: CO2Meter.com
Description: The O2-A2 Alphasense Oxygen Sensor is designed to monitor 25% oxygen levels by volume. The sensor is most sought after as a replacement sensor for handheld gas detectors that use the O2-A2 sensor. Features Electrochemical Sensor measures up to
- Measurement Type: %Volume
- Electrical Outputs: Analog Voltage
- Features: Other
- Gas Types: Oxygen (O2)
-
Supplier: Analytical Industries Inc.
Description: 1-8 Tube to Sensor BC Restrictor 1 LPM Dome to Sensor Adaptor Blue Tee Adapter 15mm x 22mm Flow Diverter 15 mm 2 O-Ring Dovetail Pole Shelf Clamp Female Mounting Bracket Cable Coiled w/ Phono Jack (Exterior Sensor- Remote Style) Overview This family of cost-effective, 0-100%
- Instrument Type: Analyzer
- Gas Types: Oxygen (O2)
-
Supplier: GasLab
Description: atmospheric packaging gas testing or as a headspace oxygen analyzer for spot testing. Because of it's advanced optical chemical sensor, the TecPen MAP Oxygen Analyzer can take a measurement in 3 seconds. It is designed to last for years. Features Long-life optochemical
-
Supplier: ENMET Corporation
Description: P/N 10022-1100, SDS-97D Series Sensor/Transmitter Oxygen, O2 Features Non-intrusive push button calibration Excellent chemical selectivity 4-20 mA output, 24 VDC powered One-person calibration Digital display Electrochemical sensors RFI/EMI resistant Optional Precalibrated
- Electrical Outputs: Analog Current
- Display: Digital
- Gas Types: Oxygen (O2)
-
Supplier: GasLab
Description: GasLab's SAN-20 Personal Oxygen Safety Monitor is a wearable or hand-held personal oxygen level safety meter designed to monitor ambient air oxygen levels in real time. It is designed to protect workers in enclosed spaces around bulk gas storage, underground, below deck in
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Traditional in situ oxygen flue gas analyzers utilize zirconium oxide sensors to measure excess oxygen in process flue gas. These zirconium oxide sensors use a principle of operation based on the Nernst equation. This principle requires that the sensor cell be
- Operating Temperature: -40 to 300.2 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume
- Electrical Outputs: Analog Current
-
Supplier: COSA Xentaur Corporation
Description: CO2 sensor for a range of 0-20% (IR-Bench) and a H2S sensor for 0-500ppm (EC Sensor).
- Operating Temperature: 41 to 113 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume, Trace
- Instrument Type: Analyzer
-
Supplier: Process Sensing Technologies USA
Description: The Palm O2, Palm CO and AII-300 are handheld oxygen analyzers that provide a very easy way to verify oxygen levels prior to welding or in scuba diving tanks. Analytical Industries’ AII-3000 series or Palm O2 are a convenient way to check oxygen levels in welding gases.
- Operating Temperature: 41 to 113 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume, Trace
- Display: Digital
-
Supplier: RKI Instruments, Inc.
Description: No Description Provided
- Operating Temperature: 14 to 104 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %LEL, %Volume, Trace
- Application: Ambient Air Monitoring, Personal Exposure Monitoring
-
Supplier: DOD Technologies Inc.
Description: benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed. GX-6000 PID sensors are also resistant to
- Operating Temperature: -4 to 122 F
- Measurement Type: %LEL, %Volume
- Gas Types: Combustible Gas
- Display: Digital
-
Supplier: Linde North America, Inc.
Description: ideal for environments where deep water may be encountered. Features 4 port - 4 Gas Instrument 26 gas sensor options Data logging capability Internal Pump as standard (non-pump option) Heavy duty - extremely robust Cam lock attachment Infra-red data download Sensors
- Operating Temperature: -4 to 131 F
- Operating Humidity: 20 to 90 %
- Response Time: 10.00000000000002 seconds
- Measurement Type: %LEL
-
Supplier: Linde North America, Inc.
Description: Compact design Top display Alligator clip attachment IP65 and IP67 rated Sensors Flammable/Oxygen: LEL Methane, LEL Propane, LEL Pentane, LEL Butane, LEL Ethylene, LEL Hydrogen, LEL Alcohols/Ketones/Solvents, Oxygen. Toxic: Ozone, Carbon Monoxide, Hydrogen Sulphide, Sulphur
- Operating Temperature: -4 to 131 F
- Operating Humidity: 20 to 90 %
- Response Time: 10.00000000000002 seconds
- Measurement Type: %LEL
-
Supplier: MSA Safety
Description: Designed for superior lifespan—patented sensors operate for over two years—and high performance, the ALTAIR Single-Gas Detector is the smart choice for market-leading, cost-effective gas monitors. Features sensor options for carbon monoxide, hydrogen sulfide, and oxygen coupled
- Measurement Type: %Volume, Trace
- Features: Audible or Visual Alarms
- Gas Types: Carbon Monoxide (CO), Hydrogen Sulfide (H2S), Oxygen (O2)
- Application: Confined Space Monitoring, Personal Exposure Monitoring
-
Supplier: Industrial Scientific Corporation
Description: The MX6 iBrid® is the most adaptable six-gas monitor on the market. With hundreds of possible sensor combinations and a robust list of available configuration settings, the MX6 iBrid gas detector is ready to monitor oxygen, toxic and combustible gas, and volatile organic compounds
- Number of Channels: 6
- Operating Temperature: -4 to 131 F
- Operating Humidity: 15 to 95 %
- Measurement Type: %Volume, Trace
-
Supplier: Industrial Scientific Corporation
Description: Built to Industrial Scientific's highest quality and reliability standards, GasBadge® Pro provides a lifetime of gas hazard protection. Interchangeable sensors enable the GasBadge Pro to be quickly adapted to monitor unsafe levels of oxygen or any one of the following toxic gases:
- Number of Channels: 1
- Operating Temperature: -40 to 140 F
- Operating Humidity: 0 to 99 %
- Features: Audible or Visual Alarms, Data Logger
-
Supplier: Linde North America, Inc.
Description: solution for both operators and engineers across all industries. Features Premium instrument 28 gas sensor options Intelligent gas sensing Data logging capability Alligator clip attachment Compact design Lightweight and robust, IP65 rated and designed to IP67 standards Sensors
- Operating Temperature: -4 to 149 F
- Operating Humidity: 20 to 90 %
- Response Time: 10.00000000000002 seconds
- Measurement Type: %LEL
-
Supplier: Vaisala
Description: silicon-based non-dispersive infrared (NDIR) sensor • A single-beam, dual-wavelength CO2 measurement with no moving parts • Compensation options for temperature, pressure, humidity and oxygen • Wide operating temperature and humidity ranges • Diffusion and flow-through models •
- Operating Temperature: -40 to 140 F
- Electrical Outputs: Analog Current, Analog Voltage
- Gas Types: Carbon Dioxide (CO2)
- Number of Gases Monitored: Single Gas
-
Supplier: Process Sensing Technologies USA
Description: (suffix '-SS'). The detectors are fitted with a single sensor that be either an Infrared Sensor, for the detection of Hydrocarbon gases or Carbon Dioxide, a 'Pellistor' Catalytic Sensor for detection of both Hydrocarbon gases and Hydrogen or an Electrochemical Sensor for
- Operating Temperature: 140 F
- Operating Humidity: 0 %
- Instrument Type: Detector
- Mounting Type: Fixed
-
Supplier: MSA Safety
Description: of externally-attached components. High performance XCell Sensors last longer: Typical life greater than 4 years for combustible, O2, CO/H2S, SO2, CO/NO2 and CO (high concentration) sensors. Typical life greater than 3 years for NH3 and Cl2 sensors. Most sensor response
- Operating Temperature: -40 to 122 F
- Measurement Type: %LEL, %Volume, Trace
- Gas Types: Ammonia (NH3), Carbon Dioxide (CO2), Carbon Monoxide (CO), Chlorine (Cl2), Chlorine Dioxide (ClO2), Combustible Gas, Hydrocarbons, Hydrogen Cyanide (HCN), Hydrogen Sulfide (H2S), Methane (CH4) / Natural Gas, Nitrogen Dioxide
- Features: Audible or Visual Alarms, Hazardous Environments, Interchangeable Probes, Intrinsically Safe, Other, Sampling Pump
-
Supplier: Bacharach, Inc.
Description: alkalines or line power) ensure the unit is always ready for use. Probes and hoses come in a variety of lengths and materials to satisfy a wide range of applications, including NOx, SO2 and other requirements. Automatic sensor protection not only guards the sensors from damage, but
- Operating Temperature: 32 to 113 F
- Operating Humidity: 15 to 90 %
- Measurement Type: %Volume, Trace
- Instrument Type: Analyzer
-
Supplier: New England Tubing Technologies
Description: provide more functionality in the same tubular cross-section – critical for today’s minimally invasive surgeries. Our eTubing™ designs can add analog and digital transmission of electrical signals for sensor capabilities, powering devices, and temperature/oxygen monitoring features by
-
Supplier: Emerson Automation Solutions – Rosemount
Description: optional local HART® interface. Sensors can be easily exchanged, with NE-MOS Solid State, Electrochemical, Infrared and Catalytic Bead sensor technologies available. The Millennium II BASIC transmitter automatically recognizes any connected pre-calibrated sensor and maintains an
- Number of Channels: 1
- Response Time: 4.999999999999998 seconds
- Operating Temperature: -67 to 185 F
- Operating Humidity: 0 to 99 %
-
Supplier: Emerson Automation Solutions – Rosemount
Description: from a fixed gas detection solution. Sensors can be easily exchanged, with NE-MOS Solid State, Electrochemical, Infrared and Catalytic Bead sensor technologies available. The Millennium II transmitter automatically recognizes any connected pre-calibrated sensor and maintains an
- Number of Channels: 1
- Response Time: 4.999999999999998 seconds
- Operating Temperature: -67 to 185 F
- Operating Humidity: 0 to 99 %
-
Supplier: Emerson Automation Solutions – Rosemount
Description: area with a single transmitter - Mix & Match, Plug & Play! No other platform can offer this kind of versatility and performance. Sensors can be easily exchanged, with NE-MOS Solid State, Electrochemical, Infrared and Catalytic Bead sensor technologies available. The Millennium II
- Number of Channels: 2
- Response Time: 4.999999999999998 seconds
- Operating Temperature: -67 to 185 F
- Operating Humidity: 0 to 99 %
Find Suppliers by Category Top
Featured Products Top
-
signals for sensor capabilities, powering devices, and temperature/oxygen monitoring features by incorporating these customized wires or cables within the wall of the tube itself. Typical Elements for Hybrid Tubing: Power supply Measuring (read more)
Browse Medical Tubing Datasheets for New England Tubing Technologies -
In industrial automation, photoelectric sensors are small, but indispensable tools. They drive innovation and optimization across many industries, precisely detect objects, and ensure that everything runs smoothly. So, whether it's maintaining (read more)
Browse Proximity Sensors Datasheets for SICK -
Now you can gain complete visibility and control over your logistics operations with zone management solutions. Zone control is the process of controlling the flow of goods from one material handling function to another in an efficient and cost-effective manner.
It is a critical component of any effective supply chain management system, as it helps ensure that products and service...
(read more)
Browse Proximity Sensors Datasheets for SICK -
Photoelectric Sensor - Small Size Diffused Fargo Controls announces two Diffused Photoelectric Proximity Sensors. These models have a smaller size and an increased (read more)
Browse Proximity Sensors Datasheets for Fargo Controls, Inc. -
Fargo Controls - Proximity Sensors: Exceptionally Priced Inductive, Capacitive & Photoelectric Sensors. This proximity sensor line offers an appealing assortment of the most popular configurations of Inductive, Capacitive and (read more)
Browse Proximity Sensors Datasheets for Fargo Controls, Inc. -
Fargo Controls, Inc.'s Long Range Inductive Proximity Sensors offer some of the largest sensing distances for inductive sensors in the industry. Their distances are up to 4 times that of standard Inductive sensors. Sensors can now be mounted semi (read more)
Browse Proximity Sensors Datasheets for Fargo Controls, Inc. -
Fargo Controls, Inc. is proud to offer our Miniature Inductive Proximity Sensors with extended sensing distance. Their small size and increased sensing range allows them to be used in applications (read more)
Browse Proximity Sensors Datasheets for Fargo Controls, Inc. -
Fargo Controls, Inc. has Inductive Metal Face Proximity Sensors with Extended Sensing Distance. These flush mount 8mm, 12mm and 18mm diameter inductive sensors have a one-piece stainless steel body that includes the (read more)
Browse Proximity Sensors Datasheets for Fargo Controls, Inc. -
SICK’s economical global series of photoelectric sensors welcomes the new long range G20 sensor. G20 at-a-glance: Excellent price/performance ratio Intuitive and fast commissioning with light/dark switching, additional front LED and adjustable signal delay (read more)
Browse Photoelectric Sensors Datasheets for SICK -
Your Benefits Reduce conveyor downtime due to false switchings on background-objects Optimize sensor performance by configuring beam spacing to the mm Increase detection area across the entire conveyor bed by removing blind zones on (read more)
Browse Proximity Sensors Datasheets for SICK
Conduct Research Top
-
Why Measure CO2?
and Biofuel Production. algae biofuel sensor. Algae is used to transform water and CO2 into methane and oxygen. High carbon dioxide levels are required to maximize methane production, while low oxygen levels are required to protect the organisms. We offer CO2 sampling meters to insure peak algae
More Information Top
-
A hand-held optical sensor for dissolved oxygen measurement
The optical sensing system of the hand-held oxygen sensor is simple.
-
CR4 - Thread: Allen Bradley Question? DDV
Next in Forum: Handheld Oxygen Sensor .
-
Influence of post-exercise hypoxic exposure on hepcidin response in athletes
During the 3 h post-exercise HYP exposure, the FIO2 was recorded each hour using a hand-held oxygen sensor (Handi®+ , Maxtech, Ut, USA), and blood oxygena- tion levels were monitored in the final 15 min of this recov- ery period by…
-
Spectroscopy Setup for UV-Vis Diffuse Reflection Measurements
• Handheld Oxygen Sensor for Measuring Gaseous Dissolved Oxygen in a Variety of Media .
-
High-Resolution Spectrometer and Accessories for Laser Analysis
• Handheld Oxygen Sensor for Measuring Gaseous Dissolved Oxygen in a Variety of Media .
-
Overcoming Limitations of Handheld Raman Analysis – Ocean Optics IDRaman mini
• Handheld Oxygen Sensor for Measuring Gaseous Dissolved Oxygen in a Variety of Media .
-
Dichroic Filter Array Patented Patterned Coatings Technology by Ocean Optics
• Handheld Oxygen Sensor for Measuring Gaseous Dissolved Oxygen in a Variety of Media .
-
Fiber Optic Oxygen Sensors, Theory of Operation by Ocean Optics
• Handheld Oxygen Sensor for Measuring Gaseous Dissolved Oxygen in a Variety of Media .
-
Oxygen Sensing Kit - FoxyKit from Ocean Optics : Quote, RFQ, Price and Buy
Handheld Portable Oxygen Sensor - NeoFox Sport Phase Measurement System from Ocean Optics .
-
Phase Measurement System - NeoFox Oxygen Sensor from Ocean Optics : Quote, RFQ, Price and Buy
Handheld Portable Oxygen Sensor - NeoFox Sport Phase Measurement System from Ocean Optics .
Indicates content that may require registration and/or purchase.