Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Tempco Electric Heater Corporation
Description: Heat trace cables are used to counteract the effects of heat loss from process piping systems. It comes in 2 styles: Constant Wattage and Self-Limiting. Common Applications Asphalt Plants Freeze Protection Mines Oil Refineries Pulp and Paper Mills Sprinkler Systems
- Heater Type: Heat Tracing, Heating Cable
-
Supplier: Radwell International
Description: NELSON HEAT TRACING Heating Elements PLT-BS-U-3
-
Supplier: Radwell International
Description: RAYCHEM THERMAL MANAGEMENT Heating Elements CS-100-A
-
-
Supplier: Radwell International
Description: SIEMENS INDUSTRY Heating Elements ASZ6.6
-
Supplier: Radwell International
Description: CABLE, CWP PIPE TRACE, 280 W, 120 V, 40 FT LENGTH WITH THERMOSTAT & PLUG. FREE 2 YEAR RADWELL WARRANTY
-
Supplier: Heatizon Systems
Description: Heat Trace Eaves, Gutters & Downspouts with GutterMelt Gutter Melt SR 120, 208, 240, and 277V Self Regulating roof and gutter heat trace cables are designed to economically and effectively provide heat to maintain water flow paths on eaves, in gutters
- AC Voltage Required: 120 to 277 volts
- Fuel / Energy Source: Electric
- Maximum Operating (Sheath) Temperature: 150 F
-
Supplier: Chromalox
Description: Hot Water Maintenance for Temperatures up to 140°F Heat Output Varies Along Pipe Length to Deliver Heat Where Needed Circuit Lengths up to 800 ft 16 Awg Buss Wires Self-Regulating Conductive Core Fluoropolymer Jackets Wattages at 5 and 10 w/ft 120 and 208-277 V Cable Available
- AC Voltage Required: 120 to 277 volts
- Fuel / Energy Source: Electric
- Heater Type: Heat Tracing, Heating Cable
- Maximum Operating Temperature: 140 F
-
Supplier: OMEGA Engineering, Inc.
Description: SRM/E self-regulating heating cable provides safe, reliable heat tracing for process temperature maintenance and freeze protection of pipes, valves, tanks and similar applications. The 190°C (375°F) maximum exposure temperature rating allows steam cleaning of process equipment with up
- AC Voltage Required: 120 to 240 volts
- Fuel / Energy Source: Electric
- Insulation Options: Fiberglass Insulation
- Maximum Operating (Sheath) Temperature: 420 F
-
Supplier: RS Components, Ltd.
Description: Self Limiting Heat Tape-Termination kit - Electrical Power & Industrial Cable - Trace Heating Accessories
-
Supplier: Chromalox
Description: The DTS-HAZ digital thermostat kit is a microprocessor based temperature control and power connection kit used for freeze protection or process temperature maintenance of pipes or tanks protected by heat tracing products. This thermostat can be used with Constant Wattage, Mineral Insulated or
- Temperature Set Point Range: -80 to 1100 F
- Thermostat Type: Digital
-
Supplier: Chromalox
Description: The Chromalox intelliTRACE ITC series is designed for line or ambient sensing heat trace applications such as freeze protection and/or process temperature control. This controller may be used with constant wattage, mineral insulated or self regulating heating cables. The
- Temperature Controller Type: Heating Control
-
Supplier: Thermon, Inc
Description: monolithic co-extrusion process, HTSX is the market leading self-regulating heat tracing technology. The heat output of HTSX varies in response to the surrounding temperature. Variations in the ambient temperature or heat lost through the thermal insulation are compensated for
- AC Voltage Required: 110 to 120 volts
- Fuel / Energy Source: Electric
- Heater Type: Heating Cable
- Maximum Operating Temperature: -60 to 302 F
-
Supplier: CSA Group
Description: Preface This is the fourth edition of CSA C22.2 No. 130, Requirements for electrical resistance trace heating and heating device sets. It supersedes the previous edition published in 2003 under the title Requirements for electrical resistance heating cable and heating device sets, two
-
Supplier: UL Standards & Engagement
Description: This part of IEC 60079 standard specifies general and testing requirements for electrical resistance trace heaters for application in explosive atmospheres with the exclusion of those for EPL Ga and Da. This standard covers trace heaters that comprise either factory or field
-
Supplier: R. STAHL, Inc.
Description: Suitable for both indoor or outdoor use for armoured or unarmoured cables and heat trace cables. With O-ring seal for ingress protection. Features Seal on outer sheath only Applications Outdoor or indoor for armoured or unarmoured cables.
- Material: Brass, Stainless Steel
- Mounting Size: 0.6299 to 3.54 inch
- Temperature Range: -76 to 275 F
-
Supplier: Heat Trace Products, LLC
Description: The 2800 family of self-regulating heating cable is designed for all your commercial freeze protection applications. The Heat Trace Products Self-Regulating design allows for safety and ease of cut-to-length installation, Heat Trace Products Dekoron self-regulating
- AC Voltage Required: 110 to 277 volts
- Heater Type: Heat Tracing, Heating Cable
- Heating Capacity: 0.0030 to 0.0060 kW
- Maximum Operating (Sheath) Temperature: 150 F
-
Supplier: Transcat, Inc.
Description: ) Traceable certificate Tool for insertion tubes Heat shield JOFRACAL USB cable Manual Test cables (2 x red, 2 x black) Traceable certificate - for reference sensor input Traceable certificate - for sensor-under-test input
- Process, Environmental, Thermodynamic Properties: Temperature
-
Supplier: Thermon, Inc
Description: the thermostat switch. E4X-1 A nonmetallic NEMA 4X enclosure combines thermostat functions and heating cable power connection into a single unit that can be installed directly onto a heat-traced pipe (or to a nozzle protruding from a tank).The E4X-1 provides watertight, dust tight and
- Temperature Set Point Range: 35 to 235 F
- Thermostat Type: Mechanical
-
Supplier: Panametrics
Description: simple operation Humidity measurements are traceable to National Institute of Standards and Traceability (NIST) Applications Environmental test chambers Engine test cells Clean rooms Air conditioning and heat exchange coil testing Metrology labs
- Application: Moisture in Gases / Air
- Dew Point Accuracy: 0.3600 +/-F
- Dew Point Range: -103 to 167 F
- Digital Outputs: Serial Interface
-
Supplier: The Kahn Companies
Description: variety of industries: heat treating, pharmaceutical, food and beverage, utilities, semiconductors and many other manufacturing applications. The Kahn Easidew Hygrometer consists of a digital display with integral signal conditioning board, ceramic dewpoint sensor and an interconnecting
- Application: Moisture in Gases / Air
- Dew Point Accuracy: 3.6 +/-F
- Dew Point Range: -148 to 68 F
- Display: Digital Readouts
-
Supplier: FX PCB Co., Ltd.
Description: metal-based copper-clad laminate with a good heat dissipation function. The single-layer Alu PCB is composed of a three-layer structure: circuit layer (copper foil), insulating layer, and metal base layer, see below stack up for your reference: We also designed a 2 Layer Aluminum PCB and
- Materials of Construction: Aluminum Foil / Cladding, Copper Foil / Cladding, Specialty / Other
- Thickness: 0.0197 to 0.1969 inches
-
Supplier: Inductotherm Group
Description: Radyne’s innovative new Voyager HHT™ portable hand-held induction heating system is designed for use in tight spaces. For brazing, soldering, heating, drying, coating and heat shrink, the Voyager HHT™ moves the assembly line directly to the finished assembly. The power
- Applications: Drying, Other
- Output Power: 10 kW
-
Supplier: Technic, Inc.
Description: loaded into a sliding drawer mechanism to provide a precise location for the automatic hoist to pick up. The hoist picks up a cassette and automatically conveys the cassette through each of the wet processing steps via a servomotor cable driven, X and Z-axis hoist. When the cassette is
- Application / Industry: Semiconductor / Wafer, Solar / Photovoltaic
- Equipment / System Type: Automated System
- Process / Technology: Electroplating
Find Suppliers by Category Top
Featured Products Top
-
. No more manual adjustments; our cables think for you. Comprehensive Connection Kits: Every successful heat trace installation requires reliable connections. Gaumer's connection kits are engineered for ease of use and (read more)
Browse Electric Heaters Datasheets for Gaumer Process -
Electric heat trace, or surface heating, is the application of heat to an external surface that compensates for heat lost due to changes in temperature in ambient surroundings. A well designed heat trace system should ensure that the heat trace cable’s input (read more)
Browse Heat Tracing Datasheets for Thermon, Inc -
withstands the temperature exposures associated with steam purging. The heat output of HTSX cable varies in response to the surrounding temperature. Variations in the ambient temperature or heat lost through the thermal insulation are compensated for automatically along the entire length of a heat-traced (read more)
Browse Electric Heaters Datasheets for Thermon, Inc -
Probes Heat Trace Heated Injection Machine Nozzles Lab Equipment Machine Components Pipe Heaters Silicon Wafer Processing Sprue Bushing in Runnerless Molding (read more)
Browse Coil Heaters Datasheets for Tempco Electric Heater Corporation -
FLX self-regulating heating cables are designed to provide freeze protection and temperature maintenance to metallic and nonmetallic pipes, tanks and equipment. FLX heating cables are rated for heat outputs of 10, 16, 26 and 33 watts/meter at 10°C (3, 5, 8 and 10 watts/foot at 50° F (read more)
Browse Heat Tracing Datasheets for Thermon, Inc -
. Additionally, these additives reduce power consumption, increase print speed and reduce the risk of heat damage. When integrated into the jacket material of wires and cables, along with AGC’s standard color masterbatch offerings, these concentrates provide (read more)
Browse Chemical Additives and Agents Datasheets for AGC Chemicals Americas, Inc. -
length required in the field. Flexible materials and small cross-section provide an excellent bending radius for wrapping around complex geometries. ENERGY EFFICIENT The heat output of DLX varies along the length of the traced equipment or surface, providing the (read more)
Browse Heat Tracing Datasheets for Thermon, Inc -
Series Constant Watt Heating Cable Long Line Temperature Maintenance or Freeze Protection TEK series resistance constant watt heating cables are used where circuit lengths exceed the limitations of parallel resistance heating cables. Circuit lengths up to 12,000 feet (3,658 m) can be (read more)
Browse Electric Heaters Datasheets for Thermon, Inc -
The self-regulating heat output of KSR cable varies in response to the surrounding concrete temperatures. When the concrete is at or below freezing temperatures, KSR will deliver the maximum power output. As the concrete warms-up, the power output of the cable will decrease. Energy efficiency (read more)
Browse Flexible Heaters Datasheets for Thermon, Inc -
connector & cage configurations Improved Thermal Management • Utilizes integrated thermal bridge and Zipper heat sinks technology which provide superior thermal performance Design (read more)
Browse Cable Assemblies Datasheets for TE Connectivity
Conduct Research Top
-
Heat Trace Cable vs. Immersion Heaters
With the advancement in technology and increase in industrial demand, industries have started to mobilize over different heating methodologies such as whether to use heating cables or immersion heaters.
-
Self Regulating Heat Trace Cables Comparison
Knowing the difference between CR and CT, what they are designed to do and the applications for which they are suited can result in a great deal of savings because of the cost variation.
-
Electric Snow Melt System Evaluation Utilizing Infrared Imaging (.pdf)
This paper explains the use of Infrared Imaging as a method to quickly and efficiently determine the operational ability of snow melt systems for roof, valley, gutters and downspouts. It could also be easily utilized for these other heat trace cable systems: ?Pavement and Walkway Snow Melt Systems
More Information Top
-
CR4 - Thread: Self Regulating Heat Tracing Cable
Self Regulating Heat Tracing Cable .
-
Flow assurance modeling using an Electrical Trace Heated Pipe-In-Pipe: From Qualification to Offshore Testing
The ETH-PIP is a standard Pipe-in-Pipe enhanced with 4 heat trace cables , and 2 DTS optical fibers spiralled against the inner pipe and covered by a high performance thermal insulation.
-
Controlling Condensation Through the Use of Active and Passive Glazing Systems
Others will allow this approach only if the electrical heat trace cables are Underwriters Laboratories (UL) listed specifically for window applications.
-
[An improved, more reliable and more marketable version of the Automatic Metering System]
Texas Research Institute Austin, Inc. (TRI/Austin) was tasked by Letco International to evaluate its Automatic Metering System (AMS), a proportional controller for heat tracing cable .
-
Technical and Economical Comparison of Subsea Active Heating Technologies
… with the development of heated flexible pipe designated IPB (Integrated Production Bundle) already used for field development in West Africa and Brazil as well as a rigid heated pipe-in-pipe technology, both using electrical heat trace cables , Technip has been involved …
Indicates content that may require registration and/or purchase.