Supplier: Micro Sensor Co., Ltd.
Description: and capable for use in hydrogen environments. Its all-welded design of sensing elements, wide working temperature, and various cable materials optional, make it an effective pressure-measuring solution for the hydrogen industry. · Hydrogen Service Gold Plated Diaphragm ·
- Working Pressure Range: 1.450377 to 1,015.2639 psi
- Pressure Measurement: Absolute, Gauge
-
Supplier: Accuris
Description: METHOD FOR MEASUREMENT OF HYDROGEN EVOLVED FROM DEPOSITED METAL
-
Supplier: Accuris
Description: Method of Measurement for Hydrogen Evolved from Steel Welds
-
-
Supplier: SAE International
Description: which necessitate physical measurements of the fuel supply [ 1 ]. BMW has developed an equation and subsequent testing methods to accurately and effectively determine hydrogen fuel consumption in light-duty vehicles using only exhaust emissions. Known as "Hydrogen-Balance", the
-
Supplier: Accuris
Description: Method of measurement of hydrogen permeation and determination of hydrogen uptake and transport in metals by an electrochemical technique
-
Supplier: Accuris
Description: Method of measurement of hydrogen permeation and the determination of hydrogen uptake and transport in metals by an electrochemical technique
-
Supplier: CSA Group
Description: evaluating hydrogen uptake in metals, based on measurement of steady-state hydrogen flux. It also describes a method for determining effective diffusivity of hydrogen atoms in a metal and for distinguishing reversible and irreversible trapping. ISO 17081:2014 gives
-
Description: describes a method for evaluating hydrogen uptake in metals, based on measurement of steady-state hydrogen flux. It also describes a method for determining effective diffusivity of hydrogen atoms in a metal and for distinguishing reversible and irreversible trapping. ISO
-
Supplier: Electro Optical Components, Inc.
Description: Electro Optical Components offers state of the art hydrogen sensor products. The technology uses a patented nano thin-film technology (palladium alloy) with key advantages in hydrogen sensing. The sensor technology uses a thin film palladium alloy that absorbs and desorbs
- Operating Temperature: -40 to 131 F
- Gas Types: Hydrogen (H2)
- Number of Gases Monitored: Single Gas
- Measurement Type: Trace
-
Description: Metallic and other inorganic coatings -- Electrochemical measurement of diffusible hydrogen in steels -- Barnacle electrode method
-
Description: ISO 23828:2008 specifies the procedures for measuring the energy consumption of fuel cell passenger cars and light duty trucks which use compressed hydrogen and which are not externally chargeable.
-
Supplier: CSA Group
Description: analysis such as gas chromatography, mass spectrometry and so on. In the case of hydrogen continuous charging such as hydrogen absorption in aqueous solution at free corrosion potential, hydrogen absorption in atmospheric corrosion environments and hydrogen absorption in
-
Supplier: H2scan, Corp.
Description: H2scan's HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10%
- Operating Temperature: -4 to 104 F
- Operating Humidity: 0 to 95 %
- Response Time: 60 seconds
- Measurement Type: %Volume, Leakage
-
Supplier: ASTM International
Description: 1.1 This test method covers an electronic hydrogen detection instrument procedure for measurement of plating permeability to hydrogen. This method measures a variable related to hydrogen absorbed by steel during plating and to the hydrogen permeability of the plate
-
Supplier: ABB Measurement & Analytics
Description: This technique is fast, accurate over a broad measurement range and offers outstanding reproducibility. The AlSCANTM is recognized by the industry with more than 400 units sold worldwide. The AlSCANTM hydrogen analyzer is portable and designed to survive the severe plant environment.
- Sample Form: Gaseous Samples
- Elements Analyzed: Hydrogen (H)
- Analysis Method / Detection Technology: Thermal Conductivity Detector
-
Supplier: ASTM International
Description: 1.1 This test method covers an electronic hydrogen detection instrument procedure for measurement of plating permeability to hydrogen. This method measures a variable related to hydrogen absorbed by steel during plating and to the hydrogen permeability of the plate
-
Supplier: Hydrogen Sense Technology Co., Ltd
Description: The H2Sense 8 series Hydrogen Sensor is specially designed for Hydrogen measurement applications in Fuel Cell sector. Our patent solid state palladium alloy hydrogen thin film sensor technology is hydrogen specific and does not have cross sensitivity with other gas
- Operating Temperature: -40 to 248 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Voltage
- Gas Types: Hydrogen (H2)
-
Supplier: ASTM International
Description: 1.1 This test method is primarily intended for gravimetric determination of particulates in hydrogen intended as a fuel for fuel cell or internal combustion engine powered vehicles. This test method describes operating and quality control procedures required to obtain data of known quality
-
Supplier: Micro Sensor Co., Ltd.
Description: MPM280Au Hydrogen Pressure Sensor is a measuring element specially developed for hydrogen measurement applications. The transducer has a flat membrane structure as a whole and adopts gold plating techniques on the membrane, so as to effectively prevent the occurrence of
- Measurement Type: Absolute, Gauge
- Device Category: Sensor
-
Supplier: ABB Measurement & Analytics
Description: LGR’s Hydrogen Sulfide Analyzer (H2S Analyzer) measures H2S in ambient air and in industrial processes with extremely high precision, sensitivity and accuracy. No longer do you have to wait a long time to measure hydrogen sulfide gas with high reliability – LGR’s H2S Analyzer provides
- Application: Ambient Air Monitoring, Process Gas
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Hydrogen Sulfide (H2S)
-
Supplier: H2scan, Corp.
Description: configured to operate in background gas streams with up to 95% relative humidity and temperatures up to 60°C. The HY-OPTIMA™ 1700 series is ideal for process gas applications where real time continuous measurements of hydrogen can increase process plant efficiencies, improve
- Operating Temperature: -4 to 104 F
- Operating Humidity: 0 to 95 %
- Response Time: 30 seconds
- Measurement Type: %Volume
-
Supplier: ABB Measurement & Analytics
Description: LGR's Hydrogen Chloride Analyzer (HCl, H2O) provides sensitive measurements of HCl and H2O in ambient air or in industrial process flows (e.g., coal and cement exhaust streams) continuously with extremely high precision and sensitivity. No longer do you have to spend a lot of money or
- Application: Ambient Air Monitoring, Process Gas
- Instrument Type: Analyzer
- Gas Types: Hydrogen Chloride (HCl), Water Vapor
- Number of Gases Monitored: Multi Gas
-
Supplier: LECO Corporation
Description: Hydrogen determinations are delivered quickly and precisely with the DH603 using residual, diffusible, and total hydrogen measurements. This robust instrument determines the amount of residual hydrogen (or diffusible and residual hydrogen when equipped with the
- Elements Analyzed: Hydrogen (H)
-
Supplier: H2scan, Corp.
Description: H2scan's 2620 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of
- Operating Temperature: 39.2 to 140 F
- Response Time: 60 seconds
- Measurement Type: %Volume, Leakage
- Application: Ambient Air Monitoring
-
Supplier: ASTM International
Description: 1.1 This test method describes the procedure for measuring diffusible hydrogen in steels by an electrochemical method. 1.2 This test method is limited to carbon or alloy steels, excluding austenitic stainless steels. 1.3 This test method is limited to flat specimens to which the cell can be
-
Supplier: Roscid Technologies
Description: The Model H2Trans is simple, accurate and economic measurement of Hydrogen at trace and % levels. A simple Display and one point calibration allow easy and fast start-up of the instrument. Optional 1/2 G Ex ia IIC T4 (ATEX) Specifications Measuring range ppm : 100 – 100000 ppm H2
- Response Time: 70.0000000000002 seconds
- Operating Temperature: 32 to 122 F
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
-
Supplier: Analytical Industries Inc.
Description: Key features Hazardous area certified - ATEX / UKEx / IECEx / cMETus Proven electrochemical sensor Sample air dilution pump built in Optional H2S scrubber on sample outlet Quick measurement response time Integral data logging of measurement Overview The GPR-7100 hydrogen sulfide
- Features: Data Logger, Hazardous Environments
- Gas Types: Hydrogen Sulfide (H2S)
-
Supplier: Roscid Technologies
Description: The Model H2S-Tracer is simple, accurate and very economic measurement of Hydrogen Sulfide at ppm levels.
- Instrument Type: Analyzer
- Gas Types: Combustible Gas, Hydrogen Sulfide (H2S), Toxic Gas
- Display: Digital
- Number of Gases Monitored: Single Gas
-
Supplier: SAE International
Description: This SAE Recommended Practice describes a procedure for measuring gaseous hydrogen emissions from the aqueous battery system of a battery-powered passenger car or light truck. The purpose of this procedure is to determine what concentrations of hydrogen gas an electric vehicle together
-
Description: ISO 14372:2011 specifies a method for the relative ranking, by 24 h exposure to humid air and subsequent diffusible hydrogen testing, of manual metal arc electrode coatings related to their tendency to absorb moisture. This test method has limited potential applicability since it is unlikely
-
Supplier: H2scan, Corp.
Description: H2scan's HY-ALERTA™ 600B/610B Fixed Area Hydrogen Monitors will provide hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to
- Operating Temperature: -4 to 104 F
- Operating Humidity: 0 to 95 %
- Response Time: 60 seconds
- Measurement Type: %Volume, Leakage
-
Supplier: Hydrogen Sense Technology Co., Ltd
Description: The H2Sense Model 3100 is designed for online Hydrogen in oil Dissolved Gas Analysis (DGA) measurement for oil immersed transformer and other oil filled equipment. Our patent solid state palladium alloy hydrogen thin film sensor is hydrogen specific and does not have
- Monitored Properties: Oil Properties
- Technology: Wired
-
Supplier: Vaisala
Description: For Bio-Decontamination Processes The Vaisala PEROXCAP® Hydrogen Peroxide, Humidity, and Temperature Probe HPP270 series probes HPP271 and HPP272 are designed for demanding hydrogen peroxide bio-decontamination where repeatable, stable, and accurate measurement is essential.
- Operating Temperature: 32 to 158 F
- Electrical Outputs: Analog Current, Analog Voltage
- Features: Other, Temperature Measurement
- Number of Gases Monitored: Single Gas
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 335 Portable Analyzer has been designed for the detection of hydrogen (H2) primarily in air or N2 However it can be used in some other applications with several background gases present. Consult Nova on these applications.The thermal conductivity (T/C) cell provides a fast and
- Response Time: 10 seconds
- Operating Temperature: 55 to 120 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: Hach
Description: The ORBISPHERE 51x controller using ORBISPHERE thermal conductivity sensors provides precise, selective and reliable measurements of H₂. This system is designed for process monitoring in liquid or gas phases across a wide range of applications from beverage production to rinsing semiconductor
- Number of Inputs: 1 inputs
- Number of Control Outputs: 3 outputs
- Control Signal: Current Loop, Network / Fieldbus Output, Serial / Digital, Switch / Relay Output
- Features: Datalogger
Find Suppliers by Category Top
Featured Products Top
-
High flow measurement accuracy Hydrogen is one of the gases through which ultrasound is least likely to propagate. As a result, the ultrasonic waves that propagate through the housing (housing noise) become relatively large compared to the ultrasonic signals that propagate (read more)
Browse Ultrasonic Flow Meters Datasheets for Aichi Tokei Denki Co., Ltd. -
Everything you need to know about custody transfer in the hydrogen industry Custody transfer for hydrogen is now being made possible using the latest generation of measurement technologies. ABB’s Danny Knoop explains how. Custody (read more)
Browse Flow Computers, Totalizers, and Indicators Datasheets for ABB Measurement & Analytics -
Analytical Industries Inc. Hydrogen Sulphide Analyzers are engineered to deliver dependable detection and measurement of hydrogen sulphide gas in a wide range of industrial environments. With responsive and accurate sensing technology, these analyzers support (read more)
Browse Gas Instruments Datasheets for Analytical Industries Inc. -
Knick Interface delivers SIL-rated voltage transducers and monitoring devices engineered for demanding applications like those seen within hydrogen electrolyzer and fuel cell systems. Precise measurement of stack and string-level voltage, current, and temperature is safely achievable with Knick (read more)
Browse Data Acquisition Datasheets for Knick Interface LLC -
gas analyzer systems for hydrogen monitoring Insufficient rejection of process heat can reduce the efficiency of electricity-production and increase the risk of mechanical failure. Exponentially increasing energy demands worldwide and largely (read more)
Browse Gas Instruments Datasheets for ABB Measurement & Analytics -
technologies is ideal for applications demanding precise monitoring of hydrogen levels and UVB radiation, making it a valuable asset in both industrial and research environments. There is a rapidly increasing demand for dependable detection methods to enhance safety. The S16495 photodiode is (read more)
Browse Photodiodes Datasheets for Hamamatsu Photonics Europe -
GAS High Performance Thermal Conductivity Gas Detection Modules are an excellent for precise measurement of Hydrogen (H2). They are robust, not affected by gases with dirt and dust because the measurement is not optical. They are nonselective, so good measurements in gas (read more)
Browse Gas Sensors Datasheets for Electro Optical Components, Inc. -
in various applications. In electrical circuits like circuit breakers in SF6 Gas, or moisture level control in hydrogen gas to cool generators. The applications in the semiconductor and the medical industry are mainly moisture content control in process gases and in (read more)
Browse Moisture Meters Datasheets for Innovative Sensor Technology IST USA Division -
wide range of gases and liquids. Whether monitoring hydrogen purity or moisture in transformer oil, our solutions help prevent corrosion, reduce downtime, and extend equipment life. Smart measurement is key to smarter energy. (read more)
Browse Moisture Meters Datasheets for Panametrics -
capability of the P45000 at cost-effective conditions. The compact P45000 high voltage transducer is designed for measurements of high DC voltages up to 3,900 V DC and AC voltages up to 4,500 V ACpeak, and is therefore ideally suited for industrial applications, such as in test bench setup and the hydrogen industry. For more informatoin, please visit our website at www.knick-interface.com or call at 714-499-9077. (read more)
Browse Electrical Voltage Sensors Datasheets for Knick Interface LLC
Conduct Research Top
-
Brand New Pressure Transmitter for Hydrogen Pressure Measurement
Micro Sensor designs the MPM480GH pressure transmitter, which is specially used for hydrogen pressure measurement to help users carry out hydrogen production and operation safely and reliably.
-
What is Green Hydrogen?
Electricity from renewable sources is subject to strong fluctuations and cannot be stored. This requires numerous workarounds, including the use of green power to create hydrogen, which is transported and used via the natural gas network. This presents challenges to the infrastructure of the gas
-
Hydrogen Sulfide Monitoring in Wastewater Applications
Hydrogen sulfide is gas commonly found in wastewater applications produced during the decomposition of organic matter. It is toxic, combustible and can be very corrosive. Monitoring it using a data logger requires an understanding of why the data is being collected and how it is being used to make
-
Achieve Unmatched Sensitivity and Real-time Measurement Performance of Your Hydrogen and Nitrogen Impurities with Quantum Cascade Laser Analyzers
Assuring hydrogen and nitrogen gas purity is critical across multiple processing industries and applications. For several key processes, the purity of the gas must be precisely monitored and controlled to ensure the product is within specification and avoid damage to equipment or process line
-
Moisture Measurement for Hydrogen and Natural Gas Blending
Michell Instruments: supporting the roll-out of net zero technologies
-
Considerations for Vaporized Hydrogen Peroxide Process Development
, low ppm measurement, and condensation.
-
The detection of Total Organic Chloride and/or Hydrogen Chloride
conditioning the analyser can determine the organic chlorides or hydrochloric acid (HCL) content in gases. and volatile liquid hydrocarbon streams. This paper describes the use of, on-line or in lab analysers based on the dry colorimetric technique, in. performing these measurements. This technique
-
Trace HCl Measurements in Coal-fired Power Plant Emissions Using Cavity Enhanced Laser Absorption Spectroscopy
New EPA regulations are requiring hydrogen chloride (HCI) emissions to be monitored in concentrations below 1 ppm for power plants and 3 ppm for cement plants. The properties of HCI, its reaction to other elements and sensitivity to temperature make meeting the measurement requirements challenging
More Information Top
-
Hydrogen Transport & Cracking in Metals
The larger permeability of iron to hydrogen measured when the exit face is coated with palladium is thus mainly to be attributed to the elimination of the air grown oxide.
-
2009 Annual Progress Report: DOE Hydrogen Program, November 2009 (Book)
Feng Zheng, Scot D. Rassat, David J. Heldebrant, Dustin D. Caldwell, Christopher L. Aardahl, Tom Autrey, John C. Linehan, and Kenneth G. Rappé, Automated gas burette system for evolved hydrogen measurements .
-
2010 Annual Progress Report: DOE Hydrogen Program
Results for Task 1.0, Develop and/or refine courses in hydrogen technology: To date, we have created two new courses,• “Fundamentals of Hydrogen as an Energy Carrier” to be taught in fall semesters and “ Hydrogen Measurements Laboratory” to be taught …
-
Cladding embrittlement during postulated loss-of-coolant accidents.
These post-oxidation hydrogen measurements were corrected for weight gain for comparison to pretest values.
-
http://www-pub.iaea.org/MTCD/publications/PDF/TE_1661_Web.pdf
HYDROGEN MEASUREMENT ........................................................................................
-
Review of Recent Developments in the Field of Magnesium Corrosion
represent data for which there appeared to be asignificantamountofhydrogendissolvedintheMgspecimen, so that the data would be moved upward if it were possible to plot the total amount of hydrogen generated rather than the amount of hydrogen measured .
-
Fundamental Physics in Particle Traps
Unfortunately, the precision of the hydrogen circular-state mea- surements is not sufficient to help resolve the large discrepancy between the µp measurement and the hydrogen measurements (CODATA).
-
Hot Extraction of Diffusible Hydrogen and Its Measurement Using a Hydrogen Sensor
Consequently, there was a need for an eco-friendly alternative method of diffusible hydro- gen measurement with at least the same or better mea- suring accuracy compared to the Mercury Method.
Indicates content that may require registration and/or purchase.