Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Sonel Test
Description: Measure leakage current This small, specialised measuring instrument is most often used to test alternating currents of up to 200 A. It performs measurements with a maximum resolution of 0.1 mA. With its leakage current measurement capability, the CMP-200 clamp
- Display: Digital Meter, Other
- Testing Method: Manual
-
Supplier: Sonel Test
Description: selected for different methods of analyzing the leakage spot GUD-1 generator for objects of the same pressure Description of the product Sonel TUD-1 is a compact, portable device that receives airborne ultrasonic waves and transforms them into
- Testing Method: Manual
-
Supplier: Allied Electronics, Inc.
Description: Fluke-360 AC Leakage Current Clamp Meter The Fluke 360, a rugged and accurate solution for leakage curent measurement Ideally designed for non-invasive checks of insulation condition, the Fluke 360 Leakage meter allows you to perform tests without powering down the
- AC Current Range: 0.0030 to 60 amps
- AC Voltage Range: 300 volts
- DC Current Range: 0.0030 to 60 amps
- Features: Battery Powered
-
-
Supplier: Kikusui America, Inc.
Description: The Leakage Current Tester TOS3200 is designed to perform leakage current (touch current and protective conductor current) tests on general electrical equipment but not medical electrical equipment. It enables you to conduct tests that conform to the
- Display: Digital Meter
- Features: Remote Control, Warning Indicator Light
- Interfaces: GPIB, RS232, Other
- Safety Agency Rating: CE Conformity Marks, IEC
-
Supplier: REED-Direct
Description: soft carrying case SPECIFICATIONS: Current Range: 40mA to 100A AC Resolution: 10µA to 100mA AC Accuracy: ±(1.0% +3 digits) Voltage Range: 400 VAC Resolution: 0.1 VAC Accuracy: ±(1.5% +10 digits) Resistance Range: 40 to 400? Resolution: 0.1? Accuracy: ±(1.0% +2 digits) Dimensions: 8.2 x 1.7 x
- AC Current Range: 0.0 to 100 amps
- AC Voltage Range: 0.0 to 400 volts
- Electrical Measurements: Audible Continuity, Continuity Check, Max/Min or Peak Spike Measurement
- Features: Overload Protection
-
Supplier: Allied Electronics, Inc.
Description: COMPACT CLAMP METER FOR LEAKAGE CURRENT
-
Supplier: Sonel Test
Description: Adapter for measuring the primary leakage current of welding devices and the PE leakage current of three-phase devices. To be used with meters of the PAT series.
-
Supplier: Fluke
Description: The Fluke 360 leakage tester is a rugged and accurate solution for leakage current measurement. Ideally designed for non-invasive checks of insulation condition, the Fluke 360 leakage meter allows you to perform tests without powering down the installation or
-
Supplier: TelephoneStuff.com
Description: For those who prefer traditional analog clamp meters, the 710 series hits the spot. Both rotary drum and flat scale models offer accurate, easy-to-read analog measurements. Features: - 40mA to 60AAC current capability - Audible continuity - Data hold - Analog bar graph - Min/Max - Includes
-
Supplier: Hoyt Electrical Instrument Works, Inc.
Description: Auto-Ranging microprocessor controlled. Earth resistivity ( ) test. Earth testing at 20O, 200O, 2kO, Earth voltage measuring : 0~300V AC. Automatic C spike check. Automatic P spike check. 2-Wire test, 3-Wire test, 4-Wire test. LCM display. Auto power OFF. Data hold. 200 measurement results can be
- Display: Digital Meter
- Resistance Range: 0.0 to 2 kohms
- Safety Agency Rating: Other
- Testing Method: Manual
-
Supplier: Hoyt Electrical Instrument Works, Inc.
Description: rotation (clockwise or anti-clockwise) on a LED. To test the tripping time or the tripping current of a Earth Leakage Circuit Breaker, make sure to connect the earth wire. This instrument represents the quickest and easiest way for servicing, repairing and electrical maintenance of 3
- Display: Digital Meter
- Safety Agency Rating: CE Conformity Marks, IEC
- Testing Method: Manual
-
Supplier: Evident Scientific
Description: TFB - Attached The magnetic flux leakage probes offer a superior high-saturation optimized magnetic design. Changeable wear rings improve wear resistance. These probes are ideal for air-cooler tubing inspection (with aluminum fins) and for circumferential crack detection. Features
- NDT Probe Technology: Eddy Current, Magnetic Flux Leakage
-
Supplier: Hoyt Electrical Instrument Works, Inc.
Description: High quality Taut Band movement. Four functions : DC current. AC current. AC+DC current and ACV measurement. Three input resistance ranges : 1k O, 1.5kO and 2k O 200uA full scale value. ±2.5% full scale value accuracy. Built-in overload protection circuit. Robust, Compact and
-
Supplier: Hoyt Electrical Instrument Works, Inc.
Description: Lines x 16 Characters LCD Very low consumption. Accurate digital readout of disconnection time Automatic Data Hold function. Zero crossing circuitry permit testing at 0° or 180°. Disconnection phase polarity shown on LCD display. Auto-off and off override. Polarity trip indicator (positive or
- Display: Digital Meter
- Safety Agency Rating: CE Conformity Marks
- Testing Method: Manual
-
Supplier: Sonel Test
Description: Designed to check: leakage current of a welding machine's primary circuit in a situation when it is supplied from a single-phase or threephase mains (16 A or 32 A), PE leakage current for devices supplied from a three-phase mains with a maximum current of 16 A or
-
Supplier: Ikonix USA
Description: minimum and maximum readings for Voltage, Current, Watts, Power Factor, and Leakage Current. It can be configured for use in stand alone applications or as part of a test system when interconnected to any Associated Research Hipot or Ground Bond tester. The 620L may also be
- Display: Digital Meter
- Features: Remote Control, PLC Interface
- Interfaces: GPIB, RS232, Other
- Safety Agency Rating: CE Conformity Marks
-
Description: Description / Abstract There is no abstract information for this document.
-
Description: Description / Abstract There is no abstract information for this document.
-
Supplier: Altech Corp.
Description: protection of equipment (GFPE) using the 10mA and 30mA fault current ratings, especially when high distributed capacitance or other leakages cause excessive nuisance trips at lower fault cur rents. Applications for the 300mA and 500mA ratings are equipment protection and fire
- Continuous Current Rating: 16 amps
- Mounting Style: DIN Rail Mounted
- Number of Poles: 2
- Operating Temperature: -13 to 104 F
-
Supplier: Allied Electronics, Inc.
Description: Diode, Zener; 8.2V; Zener Impedance, Maximum; Current, Reverse, Leakage, Maximum
- Diode Type: Zener Diodes
- IF: 200 mA
- IR: 31 mA
- VF: 1.2 volts
-
Supplier: Nexperia B.V.
Description: Low leakage switching diode, encapsulated in an SOD123 small Surface-Mounted Device (SMD) plastic package. Features and benefits High switching speed: trr = 0.8 µs Low leakage current: IR = 3 pA Repetitive peak reverse voltage
- Diode Applications: Switching, Low Leakage
- IF: 215 mA
- IR: 5.00E-6 mA
- RoHS Compliant: Yes
-
Supplier: Nexperia B.V.
Description: Epitaxial medium-speed switching diode with a low leakage current in a small SOT23 plastic SMD package. Features and benefits Plastic SMD package Low leakage current: typ. 3 pA Switching time: typ. 0.8 us Continuous reverse voltage: max. 75 V
- Diode Applications: Low Leakage
- IF: 215 mA
- IR: 5.00E-6 mA
- RoHS Compliant: Yes
-
Supplier: Nexperia B.V.
Description: Epitaxial, medium-speed switching diode with a low-leakage current encapsulated in a small SOD323 SMD plastic package. Features and benefits Plastic SMD package Low-leakage current: typ. 3 pA Switching time: typ. 0.8 us Continuous reverse voltage
- Diode Applications: Switching, Low Leakage
- RoHS Compliant: Yes
-
Supplier: Nexperia B.V.
Description: Epitaxial, medium-speed switching diode with a low-leakage current encapsulated in a small SOD323 SMD plastic package. Features and benefits Plastic SMD package Low-leakage current: typ. 3 pA Switching time: typ. 0.8 us Continuous reverse voltage
- Diode Applications: Switching, Low Leakage
- IF: 200 mA
- IR: 5.00E-6 mA
- RoHS Compliant: Yes
-
Supplier: Tecmark Corporation
Description: The LineGard PGFM product family provides ELCI (equipment leakage) ground fault sensing and is designed and manufactured by North Shore Safety, a leader in innovative safety products. The PGFM series operates in tandem with a Sensata ™ LEL series, UL 489 listed circuit breaker, with shunt
- CSA Mark: Yes
- Configuration: Single Device
- Device Type: Other
- Mounting / Packaging: Other
-
Supplier: Cole-Parmer
Description: • Available for sale in the United States and Canada only • The AC50A Leakage Current Clamp Multimeter offers 10 microAmp resolution for measuring low AC current • AC current measurement to 60 A • Leakage current measurements with resolution of 0.01 m
- AC Current Range: 50 amps
- AC Voltage Range: 400 volts
- DC Voltage Range: 400 volts
-
Supplier: MultiDimension Technology Co., Ltd.
Description: The information provided herein by MultiDimension Technology Co., Ltd. (hereinafter MultiDimension) is believed to be accurate and reliable. Publication neither conveys nor implies any license under patent or other industrial or intellectual property rights. MultiDimension reserves the right to make
- Accuracy: 2 %FS
- Input Voltage: 5 volts
- Operating Temperature: -40 to 185 F
- Output Type: Analog
-
Supplier: Accuris
Description: APPLIANCE LEAKAGE-CURRENT INTERRUPTERS
-
Supplier: Accuris
Description: TESTER, CURRENT LEAKAGE
-
Supplier: Accuris
Description: LEAKAGE CURRENT PROTECTION DEVICES
-
Supplier: Accuris
Description: LEAKAGE CURRENT FOR APPLIANCES
-
Supplier: Evident Scientific
Description: Features Superior high-saturation optimized magnetic design Improved wear resistance and changeable wear rings Ideal for air-cooler tubing (with aluminum fns) and for circumferential crack detection
- Diameter / Width: 12 to 29.6 mm
- NDT Probe Technology: Eddy Current, Magnetic / Hall Effect
- Style / Type: Pencil Probe
-
Supplier: SOCOMEC
Description: RESYS M40 earth leakage relays associated with a remote trip breaking device (automatic power breaking), provide the following functions: - protection against indirect contact, - limitation of leakage currents. They also preventively monitor electrical installations via their
- Current Sensing Range: 0.0300 to 30 amps
- Differential Voltage: Yes
- Features: Sealed Relay, Visual Indicator
- Frequency Sensing Range: 15 to 400 Hz
-
Supplier: Seaward Group USA
Description: The A203ES is a cost effective, simple to use, rugged test system suited to manufacturing or laboratory environments. It can deliver a test voltage of 0 to 5 kV a.c. from an internal 500VAtransformer source, and has displays that show both output voltage and current flow. Over-current
- Display: Analog Meter
- Features: Warning Indicator Light, Buzzer or Annunciator
- Safety Agency Rating: CE Conformity Marks
- Testing Method: Manual
-
Supplier: Seaward Group USA
Description: as accurate, hassle-free and convenient as possible. The Europa Plus electrical safety testing analyzer allows you to carry out accurate ground bond and leakage measurements even when multiple earth paths exist - a feature only our testers can provide. Other advances in the Europa Plus
- Current Leakage Range: 0.1000 to 19.99 milliamps
- Display: Digital Meter
- Features: Buzzer or Annunciator, Multiple Test Setup, Rapid Cutoff
- Interfaces: RS232
-
Supplier: Seaward Group USA
Description: . Traceable test results help demonstrate that a rental tool or repaired appliance is electrically safe and meets OSHA recomendations.Tests include ground bond, flash/hipot, and function and load test, continuity, polarity and leakage measurements.
- Current Leakage Range: 0.1000 to 10 milliamps
- Display: Digital Meter
- Features: Warning Indicator Light, PLC Interface, Buzzer or Annunciator, Multiple Test Setup, Rapid Cutoff, Front Panel Lockout
- Interfaces: RS232, Printer Port
-
Supplier: Seaward Group USA
Description: selectable via the rotary selector switch and dedicated push buttons for individual Single Fault Conditions. A sequence of leakage measurements can be selected for different medical devices without requiring a power break, providing a quick test solution for medical equipment requiring a
- Current Leakage Range: 0.0200 to 10 milliamps
- Display: Digital Meter
- Features: Buzzer or Annunciator
- Resistance Range: 100 to 100000 kohms
Find Suppliers by Category Top
Featured Products Top
-
that provide superior performance in the areas of: Thermal efficiency Electrical efficiency Total optical power Electrical efficiency gains are achieved by ensuring less current leakage around the semiconductor quantum wells where electron energy is (read more)
Browse Diode Lasers Datasheets for SemiNex Corporation -
The ALD810016 from Advanced Linear Devices is a part of the ALD8100xx family of Supercapacitor Auto Balancing (SAB) MOSFETs. This innovative solution is designed to address the critical challenges of voltage and leakage-current balancing in series (read more)
Browse Metal-Oxide Semiconductor FET (MOSFET) Datasheets for Advanced Linear Devices, Inc. -
include ground fault protection of equipment (GFPE), especially when high distributed capacitance or other leakages cause excessive nuisance trips at lower fault currents. RCCB Four Pole, 2- or (read more)
Browse Circuit Breakers Datasheets for Altech Corp. -
If you do have current leakage or are looking to prevent this danger in the future, make sure to contact us about North Shore Safety’s Linegard™ 30-Amp and 50-Amp Equipment Leakage Circuit Interrupter (ELCI) products that are made to prevent this hazardous electrical leakage. NSS (read more)
Browse Ground Fault Circuit Interrupters (GFCI) Datasheets for Tecmark Corporation -
Littelfuse Pxxx0S3N SIDACtors Provide High Surge Current Overvoltage Protection in Compact Package Designed for industrial applications, including factory (read more)
Browse Surge Protective Devices (SPDs) Datasheets for Littelfuse, Inc. -
support global AC EV charger safety standards including: Level 2 (UL2231-2) Mode 2 (IEC62752) Mode 3 (IEC62955) Protection against both AC and DC leakage current that can present serious shock risks Single-phase and three-phase designs (read more)
Browse Circuit Protection Components Datasheets for Littelfuse, Inc. -
broad inductance range from 0.15µH to 4.7µH and supports a significant current range of 7A to 32.5A. Designed for optimal performance, this power inductor excels in high current capacity, low Direct Current Resistance (DCR), enhanced efficiency, and reduced acoustic noise, making it (read more)
Browse Inductors, Coils, and Chokes Datasheets for ECS Inc. International -
varistors). TVS diodes have high impedance, so they act like open circuits during normal operating conditions (have low current leakage). They do not degrade, provided they are operated within the limits for which they are designed. They are manufactured in a variety of (read more)
Browse Transient Voltage Suppressor Diodes (TVS) Datasheets for MDE Semiconductor, Inc. -
Description Terminals for three phases, neutral conductor and ground 1 stage Very high attenuation Industrial or low leakage current versions Unique Selling Proposition Compact design with small footprint Single-stage filter for high efficiency Light weight design Wide temperature range (read more)
Browse Datasheets for SCHURTER Inc -
when the diode is exposed to light while reverse biased, the leakage current through it, goes up. The brighter the light from the LED, the higher the leakage current through the HV diode. Similarly, current flow through the LED determines the light intensity level. The higher the current flow (read more)
Browse Optocouplers Datasheets for Voltage Multipliers, Inc.
Conduct Research Top
-
Overcoming Patient Leakage Current Issues
IEC 60601 is the generally accepted standard for medical electrical and electronic equipment, required for the commercialization of this type of equipment in many countries. To guard against electric shock, the specification defines maximum leakage currents for equipment with an applied part
-
How Some Supervisory and Leakage Currents Can Affect Today's Low-Power Solenoid Valves
In process plants worldwide, low-power solenoid valves are used as pilot valves to open. and close larger ball or butterfly valves, or on control valves for fail-safe air release if there's. a loss of power or air. They work by pressurizing or depressurizing associated actuators.
-
Simulated Line Leakage Tests: Hocus-Pocus?
either are its nominal line voltage or at 110% of its nominal specified input voltage. It is designed to measure the leakage current that could flow through the human body under both normal and single fault conditions. Fault conditions can occur during everyday use when the ground or neutral circuits
-
Low Current MOSFET Balances High Value than 1000 Farads
A MOSFET can have low current and low voltage and still effective balance a wide range of supercapacitors with values beyond 1000F because the supercapacitor current does not flow through the MOSFET. The MOSFET only control the leakage current of individual supercapacitor cells and therefore
-
Isolation Transformer to Perform Line Leakage or Functional Run Tests
that incorporates an Isolation Transformer which is the preferred method. The current leakage path to earth ground has been eliminated with the use of the isolation transformer. This effectively eliminates the shock hazard.
-
Using the MFIA Impedance Analyzer to characterize the ESR of a Super-capacitor
When characterizing any capacitor, three critical parameters are capacitance, leakage current and equivalent series resistance (ESR).
-
Typical TVS Design Aids
Leakage current will double for every 10 to 15°C rise in temperature, depending upon the voltage (usually referenced to the ambient temperature).
-
What Tests do Ceramic Heating Elements Have to do Before they Leave the Factory?
1) Power-on test 2) Insulation resistance detection 3) Leakage Current Test
-
A New Method of Balancing Supercapacitors in a Series Stack Using MOSFETs
Novel Circuit Design Offers Insight on Over-Voltage Problem that Jeopardizes Cell Life and Provides Solution on How to Implement Automatic Leakage Current Equalization
More Information Top
-
http://www.mouser.com/catalog/supplier/library/pdf/NichiconProductCatalog.pdf
Category Temperature Range Rated Voltage Range Rated Capacitance Range Capacitance Tolerance Leakage Current .
-
Advanced Power Rectifier Concepts
On-state current flow via thermionic emission is described followed by the impact of image force barrier lowering on the reverse leakage current .
-
Tradeoffs and Optimization in Analog CMOS Design
… and channel length; performance includes effective gate-source bias and drain-source saturation voltages, transconductance efficiency, transconductance distortion, normalized drain-source conductance, capacitances, gain and bandwidth measures, thermal and flicker noise, mismatch, and gate and drain leakage current ; velocity saturation, vertical-field …
-
Leakage in Nanometer CMOS Technologies
Leakage current has become a major portion of the total power consumption, and in many scaled technologies leakage contributes 30-50% of the overall power consumption under nominal operating conditions.
-
Multi-voltage CMOS Circuit Design
Starting with a detailed overview of the evolution of IC technologies, the authors go on to examine: the sources of power consumption in CMOS ICs; the mechanism that produce sub-threshold and gate oxide leakage currents ; advanced supply and threshold voltage scaling …
-
Statistical Performance Analysis and Modeling Techniques for Nanometer VLSI Designs
Chapter 8 introduces an efficient stochastic method for analyzing the voltage drop variations of on-chip power grid networks, considering log-normal leakage current variations with spatial correlation.
-
Fundamentals of Power Semiconductor Devices
On-state current flow via thermionic emission is described followed by the impact of image force barrier lowering on the reverse leakage current .