-
Supplier: Instrumentation Northwest, Inc.
Description: status, monitor real time data, create flexible and powerful test sequences, as well as display data in tabular or graphic format and export to spreadsheets and databases. This sensor is fast, accurate, and precise to very low oxygen levels (0.01 ppm) and is the right technology
-
Supplier: Real Tech, Inc.
Description: Real Tech’s Dissolved Oxygen (DO) sensor uses a luminescent optical technology approved by the ASTM International Method D888-05. The compact and robust sensor requires no calibration and very minimal power. Without oxygen consumption, the sensor allows for
- Accuracy: 1 % FS
- Maximum Diameter / Width: 1.06 inch
- Maximum Length: 5.75 inch
- Operating Pressure Range: 70 psi
-
Supplier: CO2Meter.com
Description: Current Consumption: 600 mA @ 24VDC Dimensions: 3.5 x 2.75 x 0.50 inches Communication Analog: Linear 0-10V or 4-20mA Digital: RS485 Models CM-0134 25% Oxygen Sensor CM-0160 95% Oxygen Sensor Warranty 90 days - See CO2Meter Terms and Conditions
- Operating Temperature: -22 to 158 F
- Specific Gas Types: Oxygen (O2)
-
-
Supplier: CO2Meter.com
Description: Current Consumption: 600 mA @ 24VDC Dimensions: 3.5 x 2.75 x 0.50 inches Communication Analog: Linear 0-10V or 4-20mA Digital: RS485 Models CM-0134 25% Oxygen Sensor CM-0160 95% Oxygen Sensor Warranty 90 days - See CO2Meter Terms and Conditions
- Operating Temperature: -22 to 158 F
- Specific Gas Types: Oxygen (O2)
-
Supplier: Pem-Tech, Inc.
Description: addressed via MODBUS RTU interface. The MODBUS output provides sensor status, alarm & fault conditions. Alarm levels can be programmed via MODBUS RTU or via magnetic switch on the face of the transmitter board assembly. Ultra 1000 can be calibrated in less than 2 ½ minutes. The
- Electrical Outputs: Analog Current, Switch
- Features: Hazardous Environments
- General Gas Types: Toxic Gas
- Measurement Type: %LEL, Trace
-
Supplier: Edgetech Instruments Inc.
Description: graph 5 ranges offered: 0-100ppm, 0-1000ppm, 0-10000ppm, 0-1%, 0-25% Oxygen sensor: a micro fuel cell Easy, accessible potentiometer for one-point field calibrations
- Electrical Outputs: Analog Current
- General Gas Types: Combustible Gas
- Measurement Type: %Volume, Trace
- Number of Gases Sensed: Single Gas
-
Supplier: Pem-Tech, Inc.
Description: concentration in ppm, calibration prompts and sensor fault codes Suitable for use in Hazardous Location Description Model PT395 Series is a microprocessor-based sensor for the detection of toxic gas in ambient air. The unit features easy one-man calibration initiated
- Electrical Outputs: Analog Current, Switch
- Features: Hazardous Environments
- General Gas Types: Toxic Gas
- Measurement Type: %LEL, Trace
-
Supplier: CO2Meter.com
Description: - less than 60 seconds - ensures that your DO analyzer is always ready for use. The optical oxygen sensor is not affected by other gases including nitrogen or carbon dioxide. Measurements are taken in seconds. The data can be logged to the internal memory and downloaded via USB. A
- Accuracy: 20000 to 50000 ppm
- Display Type: Digital Display
- Dissolved O2 Range: 0.0 to 2 ppm
- Mounting / Environment: Portable
-
Supplier: CO2Meter.com
Description: The TecMicro O2-Oxygen Sensors are chemical gas sensors that can measure oxygen levels from a few parts per billion to 100% O2 by volume in ambient air or in liquid depending on the model. They are incredibly sought after for breweries, modified atmosphere packaging
- Specific Gas Types: Oxygen (O2)
-
Supplier: Mettler-Toledo Technologies GmbH
Description: High operational availability, top performance and easy maintenance InPro6960i designed for brewery application offers high operational availability, top performance and easy maintenance for the measurement of dissolved oxygen in wort aeration in breweries. The optical oxygen
- Accuracy: 1 % FS
- Mounting Options: In-Line (Insertion)
- Operating Pressure Range: 174 psi
- Oxygen Range: 0.0080 to 25 ppm
-
Supplier: ABB Measurement & Analytics
Description: sensor is 12 months, although many users benefit from a much longer operational period. Data Used up to 20 ppm or 200 % saturation Bayonet-fit connection makes removal simple Choice of process connections in BSP or NPT Replaceable oxygen sensor simplifies maintenance
- Accuracy: 0.1000 ppm
- Control Relays: 2
- Controller Functionality: Yes
- Dissolved O2 Range: 0.0 to 20 ppm
-
Supplier: Angst+Pfister Sensors and Power
Description: Product type SensorMeasuring range 0-1000 ppmDevice type Portable, StationaryGasflow Flow by diffusion, Forced flowTechnology ZirconiaApprovals NoOutput signal 55 +/-25 µA in 1000 ppm oxygenFeatures Zirconia, ppm oxygen sensorSupplier
- Electrical Outputs: Analog Current
-
Supplier: Pem-Tech, Inc.
Description: Model PT295 is a microprocessor-based sensor for toxic gas detection in parts per million (ppm) level. The unit features easy one-man calibration initiated by simply activating a magnetic switch and applying the gas. The complete sensor consists of a stainless steel
- Electrical Outputs: Analog Current, Switch
- Features: Hazardous Environments
- General Gas Types: Toxic Gas
- Measurement Type: %LEL, Trace
-
Supplier: Terra Universal, Inc.
Description: Perfect for high-precision oxygen detection inside a glovebox or other enclosure Zirconium-oxide or electrochemical fuel cell sensor provides long service life, ppm-precision, and rapid response time for increased productivity Three auto-ranging scales available: 0.01 ppm
- Application: Confined Space Monitoring
- Display: Digital
- Features: Sampling Pump
- Instrument Type: Analyzer
-
Supplier: Edgetech Instruments Inc.
Description: Range The unit will offer ranges between 0-100ppm, 0-1,000ppm, 0-10,000ppm of oxygen. 0-1% to 0-25% O2. Sensor The OxyTrans uses a special fuel cell to measure the oxygen concentration. The sensor meets the industrial requirements for accuracy,
- Electrical Outputs: Analog Current
- General Gas Types: Combustible Gas
- Measurement Type: Trace
- Number of Gases Sensed: Single Gas
-
Supplier: Edgetech Instruments Inc.
Description: modular and made of stainless steel. A defective measuring cell can be repaired by replacing the defective part only, rather than the complete unit. Portable oxygen transmitter Oxygen ranges selectable within 0-10,000ppm and 0-25% Power 85-230Vac, Optional: battery powered Uses
- Electrical Outputs: Analog Current
- Measurement Type: %Volume, Trace
- Number of Gases Sensed: Single Gas
- Operating Temperature: 32 to 122 F
-
Supplier: Mettler-Toledo Technologies GmbH
Description: system, reducing the total cost of ownership. Easy Installation The GPro 500 is an alignment-free TDL gas analyzer, meaning that the typical challenges of TDL installation and alignment are significantly reduced. Gas Measured Oxygen Lower Detection Limit 100 ppm-v Measurement
- Accuracy: 2 % FS
- Mounting Options: In-Line (Insertion)
- Operating Pressure Range: 11.6 to 72.52 psi
-
Supplier: Angst+Pfister Sensors and Power
Description: Product type Gas sensor moduleMeasuring range 0-1000 ppmDevice type StationaryGasflow Forced flowTechnology ZirconiaApprovals NoOutput signal 4-20 mAFeatures Zirconia, electronic board and sensor connected via a cableSupplier Angst+Pfister Sensors and Power
- Electrical Outputs: Analog Current
-
Supplier: Edgetech Instruments Inc.
Description: Range The unit will offer ranges between 0-100ppm, 0-1,000ppm, 0-10,000ppm of oxygen. 0-1% to 0-25% O2. Sensor The OxyTrans uses a special fuel cell to measure the oxygen concentration. The sensor meets the industrial requirements for accuracy,
- Display: Digital
- Electrical Outputs: Analog Current
- General Gas Types: Combustible Gas
- Measurement Type: Trace
-
Supplier: Sensidyne, LP
Description: Minimum Indicated Concentration .............. 31 ppm Repeatability .................... .................... ...... ± 2% of reading Accuracy * .................... .................... ......... ± 2% of full scale Zero Drift
- Features: Intrinsically Safe
- General Gas Types: Combustible Gas
- Measurement Type: Trace
- Number of Gases Sensed: Single Gas
-
Supplier: SWAN Analytical USA, INC.
Description: Sensor for the measurement of dissolved oxygen in the ppm range in water treatment technology. Features Precise oxygen measuring cell with integrated temperature measuring. Automatic monitoring of diaphragm integrity and electrolyte exhaust. Easy
- Accuracy: 0.3000 % FS
- Maximum Diameter / Width: 1.26 inch
- Maximum Length: 6.14 inch
- Mounting Options: In-Line (Insertion)
-
Supplier: Angst+Pfister Sensors and Power
Description: Also available with measurement ranges 0...1000 ppm, 0...5% or 0...25%
- Electrical Outputs: Analog Current
-
Supplier: Angst+Pfister Sensors and Power
Description: Also available with measurement ranges 0...1000 ppm, 0...5% or 0.1...95%
- Electrical Outputs: Analog Current
-
Supplier: Mettler-Toledo Technologies GmbH
Description: (23-482°F); Optional(for probe installation) 0-600°C (0-1112°F) with additional thermal barrier Effective path length 50mm - 10m, depending on adaption Process Adaption or Sensor Sensor Gas Measured:OxygenGas Measured:OxygenEffec tive path length:50mm - 10m
- Mounting / Environment: Lab / Benchtop
-
Supplier: Panametrics
Description: cell O2 sensor technology User selectable ranges for ppm and percent oxygen User-friendly and intuitive user interface with diagnostics Microprocessor-based , all-digital technology for reliable operation Low maintenance, economical and compact Sensor failure output error
- Display: Digital
- Electrical Outputs: Analog Current
- Features: Hazardous Environments, Intrinsically Safe
- Measurement Type: %Volume, Trace, Leakage
-
Supplier: SST Sensing Ltd.
Description: The O2I-Flex Oxygen Sensor Interface Electronics provides the electronics necessary to power and control SST’s range of zirconium dioxide oxygen sensors. The O2I-Flex oxygen sensor interface electronics can be user configured to output measuring ranges of
- Electrical Outputs: Analog Voltage, Analog Current
- Number of Gases Sensed: Single Gas
- Operating Temperature: 14 to 158 F
- Specific Gas Types: Oxygen (O2)
-
Supplier: Myron L Company
Description: High Performance Features Industry Leading Accuracy Adjustable for Altitude and Salinity 3 Calibration Methods: Air, Water and 0 ppm DO Dynamic Membrane Temperature Correction Easy to Use - One Button Control Waterproof
- Battery Powered: Yes
- Built-in or Self-calibration: Yes
- Display Type: Digital Display
- Dissolved O2 Range: 0.0 to 20 ppm
-
Supplier: Transcat, Inc.
Description: Product Highlights Dual backlit display of Oxygen Concentration and Temperature Measures dissolved oxygen from 0 to 20.0mg/L and 0 to 100.0% oxygen plus temperature from 32 to 122°F (0 to 50°C) Automatic Temperature Compensation from 0 to 50°C via
-
Supplier: Process Sensing Technologies USA
Description: Suitable for trace oxygen measurements from 0.1 ppm through to purity applications at 100% oxygen, these rugged portable instruments share the same advanced sensor technology as the online process oxygen analyzers ensuring confidence in their reliability and
- Display: Digital
- Features: Self Calibration
- Instrument Type: Analyzer
- Measurement Type: %Volume, Trace
-
Supplier: Process Sensing Technologies USA
Description: .05ppm allows a minimum oxygen measurement range of 0 to 10 ppm O2. Ideal for clean gas applications and when used with the XLT oxygen sensor type it allows measurement in pure carbon dioxide. The Analytical Industries long-life oxygen sensors are
- Display: Digital
- Features: Self Calibration
- Instrument Type: Analyzer
- Measurement Type: %Volume, Trace
-
Supplier: Process Sensing Technologies USA
Description: A panel mounted oxygen analyser with a remote sensor allows flexibility of installation. The GPR-1900 gas analyzer is suitable for trace oxygen measurements as low as 0-10 ppm; the GPR-2900 measures O2?up to 100%. The remote sensor block allows a very easy
- Measurement Type: %Volume, Trace
- Operating Temperature: 41 to 113 F
-
Supplier: Process Sensing Technologies USA
Description: for oxygen concentrators. The flexibility is further enhanced by different mounting options and multiple sensor types Features: Zirconia or electrochemical sensor technology options 0 to 100ppm, 0 to 1,000ppm, 0 to 25%, 0 to 96% O2 Gas connections via KF40
- Display: Digital
- Features: Self Calibration
- Instrument Type: Analyzer
- Measurement Type: %Volume, Trace
-
Supplier: Emerson Automation Solutions – Rosemount
Description: The Model 5081 family of transmitters can be used to measure pH, ORP, conductivity (using either contacting or toroidal sensors), resistivity, oxygen (ppm and ppb level), free chlorine, total chlorine, and ozone in a variety of process liquids. Choice of communication protocol:
- Accuracy: 0.0100 ppm
- Display Type: Digital Display
- Dissolved Oxygen Sensor Technology: Galvanic
- Dissolved O2 Range: 0.0 to 99 ppm
-
Supplier: OTT Hydromet
Description: Measures conductivity, temperature, depth, dissolved oxygen, pH, turbidity, and chlorophyll. It is ideally suited for extended deployments in remote, biologically rich environments, for depths to 350 m Factory calibration and streamlined reference checks enable users to generate
- Mounting / Environment: Other
-
Supplier: Sensidyne, LP
Description: Minimum Indicated Concentration .............. 0.07 ppm Repeatability .................... .................... ...... ± 2% of reading Accuracy * .................... .................... ......... ± 2% of full scale Zero Drift
- Features: Intrinsically Safe
- General Gas Types: Toxic Gas
- Measurement Type: Trace
- Number of Gases Sensed: Single Gas
-
Supplier: Sensidyne, LP
Description: Minimum Indicated Concentration .............. 2 ppm Repeatability .................... .................... ...... ± 2% of reading Accuracy * .................... .................... ......... ± 2% of full scale Zero Drift
- Features: Intrinsically Safe
- General Gas Types: Toxic Gas, Combustible Gas
- Measurement Type: Trace
- Number of Gases Sensed: Single Gas
-
Supplier: Sensidyne, LP
Description: Minimum Indicated Concentration .............. 4 ppm Repeatability .................... .................... ...... ± 2% of reading Accuracy * .................... .................... ......... ± 2% of full scale Zero Drift
- Features: Intrinsically Safe
- General Gas Types: Toxic Gas, Combustible Gas
- Measurement Type: Trace
- Number of Gases Sensed: Single Gas
Find Suppliers by Category Top
Featured Products Top
-
Advanced Photoacoustic NDIR CO? Sensor for Compact Environmental Monitoring The SCD40-D-R2 from Sensirion is a miniature CO? sensor utilizing innovative photoacoustic non (read more)
Browse Gas Sensors Datasheets for Win Source Electronics -
features: Non Dispersive Infra-Red (NDIR) Dual beam / Reference channel Measure 20 refrigerent gases with one sensor Internal calibration curve for each Freon Dual range 2000 ppm and 1000 ppm selectable Easy target gas (read more)
Browse Gas Sensors Datasheets for Electro Optical Components, Inc. -
Sensore’s trace oxygen sensors are designed for applications requiring highly accurate measurement of very low oxygen concentrations—from percentage levels down to parts per million (ppm). These advanced sensors are ideal for monitoring oxygen in inert gas systems, glove boxes, gas (read more)
Browse Dissolved Oxygen Sensors Datasheets for Sensore Electronic GmbH -
concentrations. The new PAS sensors measure ethylene concentrations in a range from 5 to 1,000 ppm with a precision tolerance of 1 percent of the measured value ±1.5 ppm. The sensor module is designed to automatically control all processes and components. No external controller required (read more)
Browse Gas Sensors Datasheets for Electro Optical Components, Inc. -
Reliable, long-life oxygen measurement for demanding industrial and safety-critical applications The Microx ProSafe SIL2 oxygen transmitter combines advanced zirconia sensor technology with SIL2-certified safety performance, offering highly accurate oxygen monitoring (read more)
Browse Dissolved Oxygen Sensors Datasheets for Sensore Electronic GmbH -
ADI's ADR1001 is a fully integrated, ultra-low drift, buried Zener precision voltage reference solution in a single chip. By integrating the entire signal conditioning circuitry required by the LTZ1000 into a single chip, the ADR1001 significantly reduces the overall solution (read more)
Browse Current Sensors Datasheets for DigiKey -
There are two versions of these Hydrogen Chloride (HCL)sensors: 4HCL-20 0 – 20ppm resolution (read more)
Browse Gas Sensors Datasheets for Electro Optical Components, Inc. -
TS-3032-C7 is an ultra-low power 12-bit Temperature Sensor Module combined with an High Performance Temperature Compensated Real-Time Clock IC with I²C interface and High and Low (read more)
Browse Sensor Chips Datasheets for Micro Crystal AG -
- 20ppm Semeatech has a complete line of Electrochemical Sensors and Accessories for your gas sensing requirements. (read more)
Browse Gas Sensors Datasheets for Electro Optical Components, Inc. -
The AsH3 Arsine Sensor has: Detection range of 0 - 1ppm Resolution of 50 ppb Fast with minimal cross sensitivity Excellent baseline stability (read more)
Browse Gas Sensors Datasheets for Electro Optical Components, Inc.
More Information Top
-
Design, Fabrication, and Testing of Getter-Based Atmosphere Purification and Waste Treatment System for a Nitrogen-Hydrogen-Helium Glovebox
Oxygen Sensor (0- 1000 ppm .
-
Study of x/spl alpha/-Fe/sub 2/O/sub 3/-(1-x)ZrO/sub 2/ solid solution for low-temperature resistive oxygen gas sensors
The relative resistance of the sensor at 1000 ppm of oxygen was characterized at the operating temperature of 320 C.
-
Inorganic solid state chemically sensitive devices: electrochemical oxygen gas sensors
… of reactive gases. so that equilibrium gas concentrations may be measured where required: response time to a change in gas concentration can be rapid (e.g. -50 ms for a zirconia oxygen sensor in more than 1000 PPM 0:at 700 "C …
-
O/sub 2/ sensing properties of Zn- and Au-doped Fe/sub 2/O/sub 3/ thin films
It is observed the sensor has a high response to oxygen at 1000 ppm of O and good linearity in a wide range of concentration (100 ppm—0.1% of oxygen).
-
Investigation of structural and gas sensing characteristics of un-doped and Co-doped SnO2 nanostructured thin films
Figure 3 shows the oxygen and carbon dioxide sensing characteristics of the Co–SnO2 thin films measured at different temperatures when exposed to a fixed amount of these gases (injecting 1000 ppm oxygen and carbon dioxide respectively into the sensor chamber).
-
Glucose oxidase immobilization onto a plasma‐induced graft copolymerized polymeric membrane modified by poly(ethylene oxide) as a spacer
Thepermeability of GOD immobilizedonto a PAAc- grafted PE membrane was studied by adding stan- dard concentrations of the substrate, glucose, from 25 to 1000ppm , and measuring the dissolvedoxygen obtained at the oxygen sensor .
-
Gas Detection - Safety - Grainger Industrial Supply
• Certifed Pre-Owned Gas Detector, Detects Carbon Monoxide, Hydrogen Sulfide, Oxygen , Lower Explosive Limit, Sensor Range CO 0 to 1000 ppm , H2S 0 to 500 ppm, O2 0 to 30 Percent, LEL 0 to 100 Percent, Housing Color Black, Operating Temp.
-
ZCP2006MST3163
The requirements for NOx sensor are very close to those of lambda oxygen sensor ; operating temperature 300- 1000 , sensing range 1003000 ppm and corrosive atmosphere containing from 3% to 8% oxygen with water vapor[4].
-
Carbon Monoxide (CO) Gas Detectors - Grainger Industrial Supply
• Certifed Pre-Owned Gas Detector, Detects Carbon Monoxide, Hydrogen Sulfide, Oxygen , Lower Explosive Limit, Sensor Range CO 0 to 1000 ppm , H2S 0 to 500 ppm, O2 0 to 30 Percent, LEL 0 to 100 Percent, Housing Color Black, Operating Temp.
-
Carbon Monoxide Detectors - Grainger Industrial Supply
• Certifed Pre-Owned Gas Detector, Detects Carbon Monoxide, Hydrogen Sulfide, Oxygen , Lower Explosive Limit, Sensor Range CO 0 to 1000 ppm , H2S 0 to 500 ppm, O2 0 to 30 Percent, LEL 0 to 100 Percent, Housing Color Black, Operating Temp.
Indicates content that may require registration and/or purchase.