Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Tradeport Electronics Group
Description: DAC-PD-7 is designed to reduce complicated tasks (calibration, wiring, and evaluation) with Partial Discharge (PD) measurements, so that can test PD promptly and easily without the expert knowledge. DAC-PD-7 alone allows all of the tests on PD without peripheral
-
Supplier: Qualitrol Company, LLC
Description: A self sufficient and portable PDM system for rapid monitoring and analysis of partial discharge in gas insulated switchgear (GIS) and power transformers. The system is field operated, touch screen based and gives engineers the tools required for diagnosing partial
-
Supplier: OMICRON electronics Corp. USA
Description: Partial discharge (PD) phenomena is evidence of a degrading insulation capacity. As partial discharge often precedes an insulation breakdown of high voltage equipment, its detection and monitoring is of vital importance. The pioneers of multi-channel synchronous PD
- Components / Products Tested: Power Supplies / Transformers, Specialty / Other
- Options / Module Types: Measure Unit / Monitor, Test Software / Program Generator
- Tester / Test Capability: Other
- Type / Form Factor: Test Module / Sub-system
-
-
Description: Defines a standard test method to assess the ability of an electromechanical component (essentially a connector) to be used under specified voltage conditions without showing partial discharges.
-
Supplier: Accuris
Description: Connectors for Electronic Equipment; Tests and Measurements - Part 4-2: Voltage Stress Tests - Test 4b: Partial Discharge
-
Supplier: Accuris
Description: Connectors for electronic equipment - Tests and measurements - Part 4-2: Voltage stress tests - Test 4b: Partial discharge
-
Supplier: Accuris
Description: Connectors for Electronic Equipment - Tests and Measurements - Part 4-2: Voltage Stress Tests - Test 4b: Partial Discharge
-
Supplier: CSA Group
Description: Defines a standard test method to assess the ability of an electromechanical component (essentially a connector) to be used under specified voltage conditions without showing partial discharges.
-
Supplier: CSA Group
Description: Applies to all types of insulating liquids used in medium and high voltage equipment. Not necessarily adapted to liquids with values of PDIV greater than 70 kV. This publication has the status of a technical report type 3.
-
Description: Applies to all types of insulating liquids used in medium and high voltage equipment. Not necessarily adapted to liquids with values of PDIV greater than 70 kV. This publication has the status of a technical report type 3.
-
Supplier: Marposs Corp
Description: produce failure of motors after short operating times (hours, days or weeks) in particular when the motor is driven by Electronic Speed Regulator (Inverter). The Partial Discharge Measurements (in particular the PDIV Test) are useful in improving the quality of production
- Mounting / Loading Options: Automatic / Inline
- Type: Gaging System / Station
-
Supplier: Qualitrol Company, LLC
Description: partial discharges from electrical interference (noise) in order to prevent false indications (alarms) when the monitored equipment is connected to the power system by >30m of power cable. Robust continuous monitor tested to withstand harsh plant conditions. Modular
-
Supplier: Marposs Corp
Description: – DLT), vibration and/or noise measurement, Partial Discharges Measurement and PDIV test (Partial Discharge Inception Voltage) in order (among other purposes) to verify the suitability of a motor to be driven by Inverter. The system AMT320/W includes in the basic
-
Supplier: IRISS, Inc.
Description: The SONUS PD is specifically designed for Partial Discharge (PD) and Airborne Emission (AE) detection on Medium and High Voltage Switchgear. The unit detects Transient Earth Voltage (TEV) signals generated by internal partial discharge as well as ultrasound acoustic
- Form Factor: Portable / Hand Held / Mobile
- Instrument Type: Condition Monitor / Fault Detector
- Technology: Ultrasonic
-
Supplier: Marposs Corp
Description: proposed as option. The most important optional tests are the Partial Discharge Test that are strongly suggested. E.D.C. is the first European Company to study (since 1998) and propose new tests that allow identification of insulation problems between windings to
-
Description: instrument transformers. DGA may also be valuable for over-excitation tests run over an extended period of time. Experience with DGA results, before and after short-time dielectric tests, indicates that DGA is normally less sensitive than electrical and acoustic methods for detecting
-
Description: partial discharges. However, DGA will indicate when these partial discharges become harmful to the insulation and may be detected by inspection [2]. This edition includes the following significant technical changes with respect to the previous edition: a) the specific
-
Supplier: Hangzhou Crysound Electronics Co., Ltd.
Description: partial discharge fault is found in the power system.The industrial acoustics imager is made of aluminum alloy shell, which is strong and durable and can adapt to the complex and changeable working environment. CRY2623 is especially for our overseas customers with English/Korean/Frenc
- Computer Interface Options: Serial Interface
- Leak Test Method: Ultrasonic Leak Detector
-
Supplier: SONOTEC Ultraschallsensorik Halle GmbH
Description: ultrasound level. This is particularly useful for comparative tests and regular maintenance checks. The SONAPHONE T ultrasonic transmitter is used alongside the SONAPHONE RD to detect leaks in non-pressurised systems: The transmitted signals escape through the leak points and are located by
- Display Type: Digital Readouts
- Leak Test Method: Ultrasonic Leak Detector
- Local Interface: Digital Front Panel
- Operating Temperature: 14 to 140 F
-
Supplier: SONOTEC Ultraschallsensorik Halle GmbH
Description: the inspection of tanks, pipes, valves and slide valves. This budget detection device can also be used for the reliable early detection of damage to friction or anti-friction bearings and for the detection of damage to electrical insulation after partial discharges. In non
- Display Type: Analog Meter or Indicator
- Leak Test Method: Ultrasonic Leak Detector
- Local Interface: Digital Front Panel
-
Supplier: CSA Group
Description: instrument transformers. DGA may also be valuable for over-excitation tests run over an extended period of time. Experience with DGA results, before and after short-time dielectric tests, indicates that DGA is normally less sensitive than electrical and acoustic methods for detecting
-
Supplier: CSA Group
Description: partial discharges. However, DGA will indicate when these partial discharges become harmful to the insulation and may be detected by inspection [2]. This edition includes the following significant technical changes with respect to the previous edition: a) the specific
-
Supplier: OFIL Systems
Description: fit for remote testing of high & medium voltage apparatuses. UVollé enables seeing pinpointed image of corona partial discharge and the emitting source. The visual information can be augmented with further data about the ambient conditions and GPS, recorded and stored for
- Form Factor: Portable / Hand Held / Mobile
- Instrument Type: Condition Monitor / Fault Detector
-
Supplier: Atlas Inspection Technologies, Inc.
Description: Corona Cameras for Early Detection of Partial Discharge and Arcing of Electrical Assets A Corona Camera offers an early and superior means of detecting corona discharge and arcing. Bi-Spectral UV imaging allows for daytime inspecting for the the indicators of degredation and
-
Supplier: OFIL Systems
Description: DayCor® RailHD is an automatic autonomous corona and arcing partial discharge detection system designed for fast inspection of electrified railways. The system inspects, displays, processes, records and generates reports for prognosis of the electrical traction condition. RAIL HD is
- Instrument Type: Condition Monitor / Fault Detector
-
Supplier: OFIL Systems
Description: conditions, and a powerful LED flashlight, to support poor lit inspected objects. Luminar HD is fit for remote testing of high & medium voltage apparatuses. It enables seeing pinpointed image of corona partial discharge and the emitting source. With the built-in GPS, temperature
- Form Factor: Portable / Hand Held / Mobile
- Instrument Type: Condition Monitor / Fault Detector
-
Supplier: AENOR
Description: Connectors for electronic equipment - Tests and measurements -- Part 4-2: Voltage stress tests - Test 4b: Partial discharge.
-
Description: Kwalyti Tooling and Machinery offers partial or complete Rebuild and Reconditioning services for virtually any brand of form-fill-seal packaging machinery. Have Kwalyti recondition a piece of your existing equipment, and you are guaranteed to appreciate the benefits that a rebuilt
- Industry: Consumer, Food and Beverage, General Industrial, Medical, Packaging, Pharmaceutical
- Location: North America, United States Only, Midwest US Only
- Machine Type: Fill and Seal Machines, Form Fill and Seal Machines, Forming Machines, Sealing Machines, Other
- Services: Prototype, R&D, Test / Inspect, Other
-
Supplier: UL Standards & Engagement
Description: 1.1 This part of IEC 60079 standard specifies the requirements for the design, construction, testing and marking of electrical equipment and Ex Components with type of protection increased safety "e" intended for use in explosive gas atmospheres. Electrical equipment
-
Supplier: UL Standards & Engagement
Description: 1.1 This part of IEC 60079 standard specifies the requirements for the design, construction, testing and marking of electrical equipment and Ex Components with type of protection increased safety "e" intended for use in explosive gas atmospheres. Electrical equipment
-
Supplier: ASTM International
Description: procedures appear in the following sections: Procedure Sections Cold Bend Test 42 to 44 Dielectric Strength Retention Test 28 to 30 Electrical Tests of Insulation 17 to 24 Heat Distortion Test 41 Heat Shock Test 40 Partial-Discharge Extinction Level
-
Supplier: ValueTronics International, Inc.
Description: subassemblies (complete phone, power amplifier, mixer, receiver, display etc.) are activated or deactivated, defective partial clusters can easily be found without using additional, complex test equipment. The reproducibility of pulse current measurements can be improved even
- DC Output Power: 150 watts
Find Suppliers by Category Top
Featured Products Top
-
conventional treatment. Method 1633 detects both conditions, providing a single landfill PFAS analysis that reflects real transport risk, instead of partial compound snapshots. Dual visibility in a single test also helps accelerate long-term management decisions. Sample Collection And (read more)
Browse Analytical Laboratory Services Datasheets for DOD Technologies Inc. -
, as well as a built-in redundancy diode for parallel and N+1 operation, are available on request. The DIO 120 converters are tested for corona (partial discharge) extinction at a minimum of 10kVrms and Hi-Pot tested for 20kVrms. The feedback system on the primary side employs a special (read more)
Browse DC-DC Converters Datasheets for ABSOPULSE Electronics Ltd.
Conduct Research Top
-
Middle East State Owned Utility Conpany Fault Prevented
The Middle East based State Owned Utility company use the IRISS Sonus PD instrument to test for Partial Discharge in their medium voltage Switchgear and accessories. In March 2014, high levels of discharge were detected on a Ring Main Unit using the Sonus PD and in response to this an offline
-
The Value of Inspection for Electrical Utilities
in various formats. Seeing corona partial discharge, correlating it to factors such as pollutions, precipitation, design and linking to past performance and faults is an example of information that utilities seek.
More Information Top
-
Condition Monitoring of Cables Task 3 Report: Condition Monitoring Techniques for Electric Cables
Special Equipment Requirements - The test is performed using highly specialized partial discharge testing equipment capable of providing an high voltage ac source of specified frequency that is capable of inducing the onset of partial discharges at voids, imperfections, gaps, or other anomalous …
-
CR4 - Thread: Partial Discharge Testing
The company that I work for owns a Ldic PD Smart Partial Discharge test equipment which is driven by a Doble M4000.
-
GIS
It can be simulated as a 110v-550KV GIS partial discharge test equipment .
-
PD
It can be simulated as a 110v-550KV GIS partial discharge test equipment .
-
Influence factors and simulation of GIS partial discharge signal propagation
The above list is only used up to the receiving points, which may correspond with the actual reception points GIS partial discharge test equipment .
-
Area 1 program summary
668 noise Mitigation and noise evaluation Diagnostics of Solar Material Partial Discharge Test equipment in a nAVLAP Certified emissions and Immunity ISO 17025 Compliant Testing Chamber.
-
Research Situation and Development Trend of Cable Distributed Temperature On-line Monitoring Technologies
Therefore, improving the precision of partial discharge testing equipment is the key factor [1,2].
-
Insulation & Dielectric Breakdown Design Considerations in Sub-Atmospheric Environments
However, difficulties arose with utilizing commercial partial discharge test equipment to evaluate electronic systems used in sub-atmospheric environments.
-
Effect of manufacturer, winding age and insulation type on stator winding partial discharge levels
Iris Power Engineering manufactures on-line partial discharge test equipment for machines.
-
Partial Discharge Characteristics of Silicone Liquids
Partial Discharge Test Equipment and Procedure A needle-plane electrode system as shown in Fig. 1 was used for the measurements.
Indicates content that may require registration and/or purchase.