Products/Services for Peak Detector Using Ad8361
-
HPLC Detectors - (49 companies)High performance liquid chromatograph (HPLC) detectors pass a beam of light through a column effluent as the fluid passes through a low-volume flow cell. Variations in light intensity are recorded and a chromatograph is generated. HPLC detectors use...Instrument TypeDetection MethodLocal Interface -
Radiation Detectors - (204 companies)Radiation detectors are used for medical diagnoses, radioactive dating measurements, and measurements of background radiation, activity levels and radiation doses. Radiation detectors are devices used to detect, track, and identify ionized radiation... -
Flaw Detectors - (252 companies)Flaw detectors are used to detect or measure defects in raw materials or finished products. This product area includes fault detectors, NDT instruments that are used to find faults in electrical, mechanical, optical, or other systems. Examples... -
Current Testers and Detectors - (45 companies)...receiver range short-mode, and open-mode receiver range. Current testers and detectors can perform audible continuity, continuity check, peak-spike, and/or true RMS measurements. They may also be used to test batteries, diodes, resistance temperature... -
Heat Detectors - (104 companies)Heat detectors are fire detection devices that sense heat produced by combustion. Heat detectors can trigger an alarm when they detect rapid temperature rise or reach a preset temperature. Heat detectors are fire detection devices that sense heat... -
GC Detectors - (38 companies)...is plotted from the time of injection and a chromatogram is generated. Gas chromatography detectors use one of several technology types to identify solutes as they exit the column. Choices include flame ionization, atomic emission, electron capture...
-
Flame Detectors - (182 companies)Flame detectors monitor and analyze incoming radiation at selected wavelengths. Flame detectors use optical sensors working at specific spectral ranges (usually narrowband) to record the incoming radiation at the selected wavelengths. Typically, 30...
-
Smoke Detectors - (260 companies)Addressable smoke detectors are fire detection products that communicate with each other in a networked system. Technology. In terms of technology, smoke detectors provide two choices: ionization chamber and photoelectric. Ionization detectors use...
-
Software Testing and Usability Services - (14 companies)Software testing and usability services evaluate software for performance, quality, user documentation, code documentation, compliance to standards and user friendliness for markets such as desktop, mobile, ecommerce, visualization and gaming...
-
Energy Use Consulting Services - (639 companies)Energy use consulting services help businesses design energy-efficient buildings, evaluate current energy usage, and develop energy management plans. They perform design reviews, energy audits, energy procurement assistance, project financing...
Product News
-
LadyBug Technologies LLC
Peak and Pulse Power Sensor LadyBug Technologies ' LB479A thermally stable peak and pulse Sensor utilizes patented technology to deliver no drift, high accuracy statistical pulse information along with average power. No user zeroing is required. The measurements are direct pulse measurement and are NOT calculated from duty cycle. The USB Sensor offers frequency coverage from 10 MHz to 8 GHz, unlike similar pulse sensors, the sensor 's full -60 dBm sensitivity is available in pulse mode. The product 's broad frequency... (read more) -
Micropower LLC
Cut Power Peaks While Fast Charging Eliminate power peaks and reduce costs. Dynamic Power Limitation (DPL) is an automatic function included in our Access and Lion battery charger series. Simply activate it to reduce those high power peaks and decrease costs. By using DPL you can control a selected group of chargers and set the available power according to your preferences, making sure that your electric bill never comes as a surprise. DPL eliminates high power peaks and expensive electrical bills by ensuring that a defined group... (read more)Browse Battery Chargers Datasheets for Micropower LLC -
InfraTec GmbH
PYRONEER Detectors with Lithium Tantalate The Rugged Ones - PYRONEER Detectors with Lithium Tantalate. LSV-Detectors combine reliability and long-term stability. Detectors for use in analytical devices and in spectroscopy have been part of InfraTec's portfolio for over 20 years. From the very beginning, these are based on high-quality, single-crystal lithium tantalate (LiTaO3). Introducing DLaTGS as a pyroelectric material last year, InfraTec developed the new PYRONEER series, which also includes spectrometer detectors based on LiTaO3... (read more)Browse Gas Sensors Datasheets for InfraTec GmbH -
Dexter Research Center, Inc.
Thermopile Detector for Gas Analysis quality. We now provide our customers with a choice from over 800 thermopile configurations, and we have new thermopile detectors coming on-line and new customers using our products around the world. Extensive line of Dexter Products includes: Temperature Detector Products. Security/Detection Detectors. Laser Power and Targeting Detectors. Gas Analysis Detectors. Fire Suppression/Detection. Infrared Imaging Products. Specialty Products: Thermopile Development Tools, Thermacon Motion Sensors... (read more) -
InfraTec GmbH
What are the advantages of a Pyroelectric Detector What is the advantage of a Pyroelectric Detector with an Integrated Beam Splitter?. Beam splitter detectors are multi-channel detectors with only a single aperture. The incoming radiation is divided into two or four spectral channels by micro mirrors inside the detector. The 2.5 mm diameter aperture allows the use of very small cuvettes for NDIR gas analysis. This results in a very low dead volume for the measurement system. In addition, many effects negatively influencing the measurement act... (read more)Browse Gas Sensors Datasheets for InfraTec GmbH -
Finder S.p.A. con unico socio
Small size movement detectors Function and features. Type 18.01 PIR movement detectors for indoor installation - wall mount. 1 NO 10 A. Output is electrically common to the supply voltage. Small size. Equipped with Light Dependent sensor and delay time. Switch off delay adjustment. Can be used in any position for movement detection. Wide detection angle (read more)Browse Motion and Occupancy Detectors Datasheets for Finder S.p.A. con unico socio -
Dexter Research Center, Inc.
Gas Analysis...Thermopile Detector and new customers using our products around the world. Extensive line of Dexter Products includes: Temperature Detector Products. Security/Detection Detectors. Laser Power and Targeting Detectors. Gas Analysis Detectors. Fire Suppression/Detection. Infrared Imaging Products. Specialty Products: Thermopile Development Tools, Thermacon Motion Sensors, Integrated Temperature Measurement Solutions. Infrared Thermopile Detectors. For more information and a datasheet, please continue to our website. (read more) -
New Yorker Electronics Co., Inc.
TD1260 Series Detector Switches E-Switch introduces the TD1260 Series detector switch, a high-performance solution designed for precise and reliable detection in a variety of applications. This compact switch offers exceptional durability and accuracy, making it ideal for use in security systems, automated equipment, consumer electronics, and other devices that require motion or activation detection. The TD1260 Series is engineered to deliver consistent performance in detecting changes in physical conditions, such as motion... (read more) -
Dexter Research Center, Inc.
ST60 Silicon - Thermopile Detector Features: A single-channel silicon-based thermopile provides lowest cost solutions in a small active area of 0.61mm x 0.61mm in a TO-5 package. Time constant of 18ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/ C. This detector has a very short thermal shock response to ambient temperature change. Applications: Excellent for non-contact temperature, fire suppression, horizon sensor, and gas analysis. Benefit: Low cost and small active... (read more)Browse Thermopiles Datasheets for Dexter Research Center, Inc. -
Acme Engineering Products
Refrigerant Leak Detector The Acme REF-IR-ST Sensor/Transmitter is designed to detect the presence of refrigerant leaks in enclosed areas. The REF-IR-ST series employs a high-precision NDIR sensor ideal for gas-specific and accurate measurements of the most commercially used refrigerants. With its 1PPM resolution, 0-1000PPM measuring range, and operating temperature and humidity characteristics, the REF-IR-ST far exceeds the current ASHRAE 15 requirements. Learn more. (read more)Browse Gas Transmitters Datasheets for Acme Engineering Products
-
Detection and diagnosis of oral neoplasia with an optical coherence microscope
… higher frequency, the displacement of the mounted piezo per volt was too low to balance the two harmonics without damage to the piezo, but a driving signal of 7.5 Vp-p was used to provide a peak -to-peak displacement of … A linear rms detector AD8361 Analog, Norwood, MA de- modulated the signal and provided an estimate of signal in- tensity, or the square of the fringe amplitude.
-
A novel 5GHz RF power detector
The simulation and experimental results show the power detector using bipolar transistors is a prospective candidate circuit for GHz signal detection. [4] R.G. Meyer, “Low-Power Monolithic RF Peak Detector Analysis”, IEEE J. Solid-State Circuits, Vol … Englewood Cliffs, NJ: Prentice-Hall, 1949 [6] AD8361 Product, Analog Device .
-
Transient Force Atomic Force Microscopy: A New Nano-Interrogation Method
The 4 peaks in the sample profile are detected in the likelihood ratios using a threshold that can detect a 0.25 nm peak in the sample profile with 99% detection probability and 1% false alarm rate. The innovation signal from FPGA is fed to a true power detector circuit (Analog Devices AD8361 ) and the output is connected to the auxiliary input of AFM setup.
-
Information Computing and Applications
… collect the value of electrical level of the sync pulse to measure the peak power of the … The detector part of the circuit is shown in Fig.2: the center adopts the AD company's true-value power detector chip AD8361 . 3-way power input use the same circuit, while power signals corresponding to different AD input ports.
-
Temperature Compensation of a MEMS Resonator Using Quality Factor as a Thermometer
… to a range of frequencies around its resonance and measuring the 3 dB bandwidth of the peak . An RMS detector can convert the signal amplitude into a DC voltage signal which is easily measured … … the thermometers, an oscillator like the one shown in Figure 1 was assembled using a 1.3 … … 53132A counter was used to measure the frequency of the resonator, and a AD8361 RMS detector was …
-
Balanced Single Photon Avalanche Detector with Variode‐Based Spike Noise Cancellation
One part is send to an analog comparator (Analog Devices, ADCM572) for discrimination, whereas the other part is send to a RF power detector (Analog Devices, AD8361 ) for feedback. The control algorithm is quite similar to the lock-in ampli- fier method used in electro optic … The threshold we used is much lower than the peak value of spike as shown in Figure …
-
Materials Engineering and Automatic Control
… be not unique because of measurement error, and thus the probability density distribution may have several peaks . We will use this distribution to establish the location reliability model, and design a dedicated technique to … If known the relative location among the light source, moving object and photoelectric detector , it can be … … the sampling rate needed by the system, the TI Corporation's double channel transforms chip AD8361 was adopted.
-
http://dspace.mit.edu/bitstream/handle/1721.1/45405/317411582-MIT.pdf?sequence=2
AD8361 (Analog Devices) together with a high-pass filter at 100 kHz and a low-pass filter at 100 MHz is used as an envelope detector . The peaks at 1.23 MHz are due to the modulation of the OPO crystal for the …
-
The Tevatron tune tracker pll - theory, implementation and measurements
obtain power from this, we simply square the output of the AD8361 . where F2 is the output of the Fourier detector and P the output from the power detector The error signal from the summer is used example, the phase shift at resonance is +10◦ then the resonance peak that we measure .
-
Radiolocation in Ubiquitous Wireless Communication
In comparison, a related part, AD8361 , has a range of only about 30 dBm. It uses the error signal (the measure of deviation from the reference) in a damped negative feedback … 1 Crest factor of a waveform is defined as the ratio of the peak to the rms … 1997) Pilotte, M. Application Note AN-691 – Operation of RF Detector Products at Low Frequency, http …
Indicates content that may require registration and/or purchase.