-
Supplier: Gagemaker L.P.
Description: Calipers are the universal measuring tool thanks in part to their versatility. Most calipers 12”/300mm and under can perform OD, ID and step measurements and normally have a depth rod for measuring deep recesses. Calipers are available with plastic, stainless steel
- Caliper Type: Nib Jaws, Slide Caliper
- Display: Dial / Analog / Direct Reading Scale
- Graduation / Resolution: 5.00E-4 to 1.00E-3 inch
- Range: 0.0 to 40 inch
-
Supplier: Transcat, Inc.
Description: Product Highlights Absolute Encoder; Takes OD, ID, Step Measurements 0 to 12" Range, ‚±0.0015" Accuracy 0.0005"/0.01 mm LCD Resolution No SPC Output 20,000-Hr Battery Life Each Unit Includes Caliper Battery Molded Case Instruction Manual
- Range: 12 inch
-
Supplier: Transcat, Inc.
Description: Product Highlights Mitutoyo ABSOLUTE 500-168 Digital Caliper, Stainless Steel, Battery Powered, Inch/Metric, 0-12" Range, +/-0.0015" Accuracy, 0.0005" Resolution Hardened stainless steel construction for protection of caliper components Four-way measurement
- Range: 12 inch
-
-
Supplier: Mahr Inc.
Description: Product features High contrast analog display Locking screw above Lapped guide way Measuring blade for inside measurements Slide and beam made of hardened stainless steel Step measuring function Immediate measurements due
- Display: Digital Display
- Graduation / Resolution: 5.00E-4 inch
- Range: 0.0 to 6 inch
- Units: English, Metric
-
Supplier: Mahr Inc.
Description: Product features High contrast analog display Locking screw above Lapped guide way Measuring blade for inside measurements Slide and beam made of hardened stainless steel Step measuring function Immediate measurements due
- Display: Digital Display
- Graduation / Resolution: 5.00E-4 inch
- Range: 0.0 to 6 inch
- Units: English, Metric
-
Supplier: Mahr Inc.
Description: Product features High contrast analog display Locking screw above Lapped guide way Measuring blade for inside measurements Slide and beam made of hardened stainless steel Step measuring function Immediate measurements due
- Display: Digital Display
- Graduation / Resolution: 5.00E-4 inch
- Range: 0.0 to 12 inch
- Units: English, Metric
-
Supplier: Mahr Inc.
Description: Product features High contrast analog display Locking screw above Lapped guide way Measuring blade for inside measurements Slide and beam made of hardened stainless steel Step measuring function Immediate measurements due
- Display: Digital Display
- Graduation / Resolution: 5.00E-4 inch
- Range: 0.0 to 12 inch
- Units: English, Metric
-
Supplier: Flexbar Machine Corporation
Description: display DIN 862 Locking screw Knife points Stepped jaw ends for internal measurementsElectronic functions Variable SPC output RS-232 & Digimatic ON/OFF Switch Zero point setting in any position mm
-
Supplier: Transcat, Inc.
Description: Product Highlights Absolute Encoder; Takes OD, ID, Step Measurements 0 to 12" Range, ‚±0.0015" Accuracy 0.0005"/0.01 mm LCD Resolution With SPC Output 20,000-Hr Battery Life Each Unit Includes Caliper Battery Molded Case Instruction Manual
- Range: 12 inch
-
Supplier: Transcat, Inc.
Description: Product Highlights Hardened stainless steel construction with satin chrome finish, for protection of caliper Four-way measurement capability for outer dimension (OD), inner dimension (ID), depth, and step measurements Vernier sliding scale moves only when spring
-
Supplier: Flexbar Machine Corporation
Description: interference. .001 reading, .100 revolution on all calipers. 360 degree bezel locks for zero setting. 4-way measurement - inside, outside, step and depth. Satin chrome finish. Each caliper supplied in its own fitted case.Model No. 15782, 0-12" Black Face Dial
-
Supplier: Flexbar Machine Corporation
Description: interference. .001 reading, .100 revolution on all calipers. 360 degree bezel locks for zero setting. 4-way measurement - inside, outside, step and depth. Satin chrome finish. Each caliper supplied in its own fitted case.Model No. 15780, 0-6" Black Face Dial
-
Supplier: Flexbar Machine Corporation
Description: interference. .001 reading, .100 revolution on all calipers. 360 degree bezel locks for zero setting. 4-way measurement - inside, outside, step and depth. Satin chrome finish. Each caliper supplied in its own fitted case.Model No. 15781, 0-8" Black Face Dial
-
Supplier: NationSkander California Corporation
Description: Large 5-Digit Easy-To-Read LCD On/Off Button With Battery Saving Automatic Shut-Off Zero Setting Button SAE/Metric Button (Inches/Millimeters) Takes Four Measurement: Inside, Outside, Depth, Step Measurement Capacity: 0 - 6" / 0 - 150mm
-
Supplier: Garage Equipment Supply
Description: Range: 0-6"/0-150mm. Graduations: .0005"/.01mm. Easy to read digital display with direct inch/metric conversion. Capable of 4 measurements - inside, outside, depth and step.
- Display: Digital Display
-
Supplier: American Welding Society (AWS)
Description: This thousandths-reading caliper features a no-glare dial for accurate readings of inside, outside, depth and step measurements. The slide is easily advanced and retracted with a free-wheeling thumb roller, and the 6" bar scale is marked with 1/10" and 1mm graduations for
-
Supplier: ValueTronics International, Inc.
Description: and refurbished test equipment. Additional Features: 12-inch Dial Caliper Graduation: .001" Range/rev: .1" Accuracy: ±002" With depth bar Permitting four types of different measurement (internal, external, depth and step
- Calibrator Style: Other Specific Calibration?
- Process, Environmental, Thermodynamic Properties: Temperature
-
Supplier: ValueTronics International, Inc.
Description: and refurbished test equipment. Additional Features: 12-inch Dial Caliper Graduation: .001" Range/rev: .1" Accuracy: ±002" With depth bar Permitting four types of different measurement (internal, external, depth and step
- Calibrator Style: Other Specific Calibration?
- Process, Environmental, Thermodynamic Properties: Temperature
-
Supplier: ValueTronics International, Inc.
Description: and refurbished test equipment. Additional Features: Hardened stainless steel construction for protection of caliper components Four-way measurement capability for multiple applications: outside diameter (OD), inside diameter (ID), depth, and step
- Calibrator Style: Other Specific Calibration?
- Process, Environmental, Thermodynamic Properties: Temperature
-
Supplier: ValueTronics International, Inc.
Description: and refurbished test equipment. Additional Features: 6" Dial Caliper Series 505 Dial range: 200 Covered rack for longer,dust free operation, inside,outside,depth & step measurements Stainless steel, hardened thoughout
- Calibrator Style: Other Specific Calibration?
- Process, Environmental, Thermodynamic Properties: Temperature
-
Supplier: RS Components, Ltd.
Description: Vernier Caliper with hardened Stainless Steel frame and jaws for extremely accurate outside, inside, step and depth measurements. Dual scale with both metric and imperial readings. Manufactured from hardened steel. Fine adjustment mechanism with lockscrews. Suitable for general
-
Supplier: RS Components, Ltd.
Description: Vernier Caliper with hardened Stainless Steel frame and jaws for extremely accurate outside, inside, step and depth measurements. Dual scale with both metric and imperial readings. Manufactured from hardened steel. Fine adjustment mechanism with lockscrews. Suitable for general
-
Supplier: RS Components, Ltd.
Description: Dial caliper for precision inside, outside, depth and step measurements Carbon Fibre construction. External/ Internal jaws. Depth rod. Rotatable bezel. Graduated 0.1mm. Graduations per revolution 100. Travel per revolution 10mm Caliper Type = Dial Capacity = 150mm
-
Supplier: RS Components, Ltd.
Description: Vernier Caliper with hardened Stainless Steel frame and jaws for extremely accurate outside, inside, step and depth measurements. Dual scale with both metric and imperial readings. Manufactured from hardened steel. Fine adjustment mechanism with lockscrews. Suitable for general
Find Suppliers by Category Top
Featured Products Top
-
direction; For example: measurement of step gages) Popular Measuring Options: API Threaded Connection Frames (NUE, LTC, EUE, Line Pipe, STC, Buttress) Dial Bore Gage Kit Radial Internal Clearance (RIC) kit / Radial (read more)
Browse Micrometers Datasheets for Pratt & Whitney Measurement Systems, Inc. -
-side Dimension (SD = both probes travel in same direction; For example: measurement of step gages) Popular Measuring Options: API Threaded Connection Frames (NUE, LTC, EUE, Line Pipe, STC, Buttress) Dial Bore Gage Kit (read more)
Browse Dimensional Gages and Instruments Datasheets for Pratt & Whitney Measurement Systems, Inc. -
builders, further developments of automated composite processing as well as automatic tool changeover have become main stream. Pratt & Whitney understands that with these new technologies, measurement solutions need to keep pace. Pratt & Whitney provides measurement solutions to such (read more)
Browse Dimensional Gages and Instruments Datasheets for Pratt & Whitney Measurement Systems, Inc. -
Dimensional Calibration Services Pratt & Whitney Measurement Systems has the technical capability and the metrology expertise needed to make reliable calibrations of master artifacts (read more)
Browse Calibration and Repair Services Datasheets for Pratt & Whitney Measurement Systems, Inc. -
= Same-side Dimension (SD = both probes travel in same direction; For example: measurement of step gages) Popular Measuring Options: API Threaded Connection Frames (NUE, LTC, EUE, Line Pipe, STC, Buttress) Dial Bore Gage Kit Radial Internal (read more)
Browse Bore and ID Gages Datasheets for Pratt & Whitney Measurement Systems, Inc. -
reproducibility Motorized probe - Improves system stability and eliminates operator influence Digital laser interferometer - Guarantees maximum resolution, traceability, and performance Two-step (read more)
Browse Optical Micrometers and Laser Micrometers Datasheets for Pratt & Whitney Measurement Systems, Inc. -
interferometer - Guarantees maximum resolution, traceability, and performance Two-step calibration - Advanced time saving feature allows for calibration in only 30 seconds.Mastering with two, NIST traceable blocks, allows continuous, accurate measurement over the full direct reading (read more)
Browse Optical Micrometers and Laser Micrometers Datasheets for Pratt & Whitney Measurement Systems, Inc. -
the Electrolimit® Indicator: Rigid design - For maximum repeatability and reproducibility Factory calibration - Used for most measurements Two-step user calibration - Allows choice of user or factory calibration (read more)
Browse Dimensional Indicators and Comparators Datasheets for Pratt & Whitney Measurement Systems, Inc. -
- Used for most measurements Two-step user calibration - Allows choice of user or factory calibration Flexible anvil fixturing - Ensures system integrity and accommodates a variety of measurement applications (read more)
Browse Dimensional Indicators and Comparators Datasheets for Pratt & Whitney Measurement Systems, Inc. -
Gauge Block Calibration (A2LA accredited / ISO 17025/cert# 2629.01) Force System Calibration (A2LA accredited / ISO 17025/cert# 2629.01) Step Gages / Gauge Bars / Surveillance Masters (read more)
Browse Test Equipment and Instrument Repair Services Datasheets for Pratt & Whitney Measurement Systems, Inc.
More Information Top
-
Effect of Elasticity of Tubes of the Hydraulic Pressure Simulator on Results of Calibration of Noninvasive Sphygmomanometers
Linear size and diameter of tubes were determined using an S Cal Pro sliding caliper with measuring step 0.01 mm and measuring error 20 μm.
-
General Quantum Modeling of Combining Concepts: A Quantum Field Model in
Fock Space
For twelve items, Pen-Knife, Stapler, Scissors, Tin Opener, Scalpel, Paper Clip, Paint Brush, Step Ladder, Measuring Calipers , Toothbrush, Spoon and Meat Thermometer, the values of c2 are different from 1 and 0, requiring genuine quantum field modeling.
-
Prediction of biomechanical trabecular bone properties with geometric features using MR imaging
Registration steps included taking caliper measurements , digital images and noting visible anatomic features at every cut.
-
Prediction of Biomechanical Properties of Trabecular Bone in MR Images With Geometric Features and Support Vector Regression
Registration steps included taking caliper mea- surements and digital images to note anatomic features at every cut.
-
Stepped mirrored structures for generating true time delays in stationary optical delay line proof-of-principle experiments for application to optical coherenc...
Step height was gauged using a pair of vernier callipers measuring each individual step .
-
Tunable laser-diode digital holographic interferometry without measuring wavelength differences
A step object profile with discontinuous structure can be measured by using a synthetic wavelength to be sufficiently large that is derived from a known step height measured by vernier calipers but not wavelength measurements.
-
Bone measurement by enhanced contrast image analysis: Ovariectomized and intact Macaca fascicularis as a model for human postmenopausal osteoporosis
The mean step height generated by each change in density was correlated to the natural log of the ac- tual height of the wedge step as measured with dial calipers .
-
A periodontal probe that measures to one tenth millimeter.
This configuration eliminates the need for multiple step measurements using stents or calipers .
-
Microbiology of Concretions, Sediments and Mechanisms Influencing the Preservation of Submerged Archaeological Artifacts
… and place on clear plastic to catch any rusticle debris falling off the platform; (Step 2) photograph (digitally) each coupon with label; (Step 3) photograph the ABS side plates inside and out; ( Step 4) measure with digital callipers the swell on the …
-
A micro-photonic stationary Optical Delay Line for fibre optic time domain OCT
The average step height measured with the callipers was 150 um, with a 10 um precision.
Indicates content that may require registration and/or purchase.