Supplier: TEGAM, Inc.
Description: Thermocouple Thermometer °F or °C (Type K) Economical TEGAM's 874 Budget Series thermometers provide the economical solution for general-purpose temperature measurement needs. The units accept type K thermocouples and probes. Constructed with
- Celsius Scale: -85 to 1100 C
- Fahrenheit Scale: -120 to 1999 F
- General Features: Battery Powered, Splash Proof, Watertight or Direct Immersion
- Scale: Fahrenheit, Celsius
-
Supplier: TEGAM, Inc.
Description: Thermocouple Thermometer Factory Tough, Lab Accurate, Dual Input K, J, T & E The Model 912A is a dual channel digital thermometer compatible with type K, J, T or E thermocouple probes to provide a wide range of temperature measurements, (-418 °F to
- Celsius Scale: -250 to 1372 C
- Fahrenheit Scale: -418 to 2502 F
- General Features: Zero adjustment, NIST Traceable or ASTM Certified
- Length: 7.6 inch
-
Supplier: Taylor Precision Products LP
Description: Features K type thermocouple thermometer. Temperature range -58°F to 2498°F / -50°C to 1340°C. Accuracy +/- 2°F / +/- 1°C. Field recalibratable. Hold, maximum/minimum temperature and auto off features. Low
-
-
Supplier: Taylor Precision Products LP
Description: Features K type thermocouple with elastomeric boot. Temperature range -58°F to 1999°F / -50°C to 1300°C. Accuracy +/- 2°F / +/- 1°C. Field recalibratable. Mini-connectors for interchangeability with any type
-
Supplier: DigiKey
Description: THERMOCOUPLE THERMOMETER, K-TYPE
- Celsius Scale: 0.0 to 50 C
- General Features: Battery Powered
- Scale: Fahrenheit, Celsius
- Technology Type: Thermocouple Technology
-
Supplier: TEGAM, Inc.
Description: The Model 922B intrinsically safe thermocouple thermometer is a single-channel digital thermometer compatible with type K, J, T,E, N, R, S or B thermocouple probes to provide a wide range of temperature measurements, (-418 °F to 2502 °F) certified
- Celsius Scale: -250 to 1820 C
- Fahrenheit Scale: -418 to 3213 F
- General Features: Battery Powered, Zero adjustment
- Scale: Fahrenheit, Celsius
-
Supplier: TEGAM, Inc.
Description: The Model 921B is a single-channel intrinsically safe digital thermometer compatible with type K, J, T,E , N, R, S or B thermocouple probes to provide a wide range of temperature measurements, (-418 °F to 2502 °F) certified intrinsically safe for use in potentially
- Celsius Scale: -250 to 1820 C
- Fahrenheit Scale: -418 to 3213 F
- General Features: Battery Powered, Zero adjustment
- Scale: Fahrenheit, Celsius
-
Supplier: Taylor Precision Products LP
Description: Features 1.575mm tip diameter probe. For use with model 9405 K type thermocouple thermometer.
- Basic Element Used: Thermocouple
-
Supplier: Taylor Precision Products LP
Description: Features Angle surface probe with 5' lead.
- Basic Element Used: Thermocouple
-
Supplier: Cole-Parmer
Description: • Wraparound cord and probe storage • Impact resistant • Waterproof design This highly accurate, type K thermocouple thermometer has a two-second response time and can be used one handed or by detaching the probe for remote use. The probe is designed to snap in place
- Celsius Scale: -40 to 260 C
- Digital Technology Type: Thermocouple Technology
- Fahrenheit Scale: -40 to 500 F
- Local Interface: Digital Front Panel
-
Supplier: SensorsONE, Ltd.
Description: The 2000T thermometer has a robust IP67 sealed enclosure suitable for indoor and outdoor industrial environments. The LCD readout has a 1999 resolution for displaying temperature in deg C or F and also includes a backlight for use in poor lighting conditions. The battery life is typically
-
Supplier: AMETEK Sensors, Test & Calibration
Description: Thermocouple KT 4, cable sensor. Measurement of temperature in ducts, pockets, machine construction containers, environmental chambers and test. Operating range is in solid, fluid and gaseous medias up to 400°C.
- Base, Noble and Refractory Metal Type: J, K
- Configuration: Grounded Thermocouple, Ungrounded Thermocouple
- Diameter or Width Range: 0.2362 inch
- Element Configuration: Single Element
-
Supplier: AMETEK Sensors, Test & Calibration
Description: Thermocouple and resistance thermometer assemblies – special sensors. For surfaces, energy measurement and handheld sensors. The 1814-2304 series of temperature sensors is typicially used within the following fields of application:
- Base, Noble and Refractory Metal Type: K, T
- Configuration: Grounded Thermocouple, Ungrounded Thermocouple
- Diameter or Width Range: 0.0394 to 0.2362 inch
- Element Configuration: Single Element
-
Supplier: AMETEK Sensors, Test & Calibration
Description: The 1800 series is a serie of thermocouple and resistance thermometer assemblies classified for installation on ships for surveillance of engines, bearings, cooling systems, cargo etc. These marine type sensors are specially designed with high resistance against vibration
- Base, Noble and Refractory Metal Type: J, K
- Configuration: Grounded Thermocouple, Ungrounded Thermocouple
- Diameter or Width Range: 0.1181 to 0.2362 inch
- Element Configuration: Single Element, Double Element
-
Supplier: Isotech North America
Description: combination of PRT and Thermocouple. The TTI-7 supports ten thermocouple Types, B,C, D, E, J, K, N, R, S and T and Pt100 thermometers. Connect up to 16 sensors via the optional switchboxes, Model 954 and 958.
- Digital: Application Software Included, Battery Powered, Has Datalogger or Data Collection Capability?, Records Min/Max Values
- Digital Technology Type: Thermocouple Technology, RTD Technology
- Interface Options: Serial Interface
- Local Interface: Digital Front Panel
-
Supplier: Cole-Parmer
Description: auto power-off after 30 minutes of inactivity to save on battery power. Accept both type K or J thermocouple probes with a miniconnector. Available in single and dual input, with results displayed on a large 1 1/4" x 1 3/4" LCD. The dual input meter (94461-12) can read and
- Celsius Scale: -200 to 1370 C
- Digital Technology Type: Thermocouple Technology
- Fahrenheit Scale: -328 to 2498 F
-
Supplier: Cole-Parmer
Description: auto power-off after 30 minutes of inactivity to save on battery power. Accept both type K or J thermocouple probes with a miniconnector. Available in single and dual input, with results displayed on a large 1 1/4" x 1 3/4" LCD. The dual input meter (94461-12) can read and
- Celsius Scale: -200 to 1050 C
- Digital Technology Type: Thermocouple Technology
- Fahrenheit Scale: -328 to 1922 F
-
Supplier: Cole-Parmer
Description: • Measures both non-contact and contact temperature • Wide temperature range for IR temperature and type K thermocouple measurements • Automatic emissivity adjustment (for temperatures 212°F or higher) • Memory stores up to 20 readings
- Celsius Scale: -50 to 800 C
- Digital Technology Type: Thermocouple Technology
- Fahrenheit Scale: -58 to 1472 F
-
Supplier: Telatemp Corporation
Description: resistance. Features include a large easy-to-read illuminated display, an easy-to-use five-button control panel, Min/Max, Hold, °F / °C switchable, auto shutoff, and low battery indicator. Each thermometer is individually factory calibrated. Automatic field calibration is easily
-
Supplier: AMETEK Sensors, Test & Calibration
Description: Thermocouple and resistance thermometer assemblies – special sensors. For surfaces, energy measurement and handheld sensors. The 1814-2304 series of temperature sensors is typicially used within the following fields of application:
- Base, Noble and Refractory Metal Type: K
- Diameter or Width Range: 0.0079 to 0.0197 inch
- Element Configuration: Single Element
- Probe Configuration: Flexible Probe
-
Supplier: Radwell International
Description: FLASHCHECK THERMOCOUPLE THERMOMETER, TYPE K, FLASHCHECK RUGGY KIT, WITH 25056 (NEEDLE PROBE). FREE 2 YEAR RADWELL WARRANTY
-
Supplier: REED-Direct
Description: or °F Accepts K-type thermocouples Includes 9V battery and holster SPECIFICATIONS: Temperature Range: -58 to 2000°F (-50 to 1300°C) Resolution: 0.1°F/°C or 1°F/°C Accuracy: ±0.5% of reading +2°F/1°C Power Supply: Single 9V battery Dimensions: 165 x 76 x 43mm Weight: 403g
- Celsius Scale Divisions: 0.1000 +/-C
- Digital: Battery Powered, Records Min/Max Values
- Digital Technology Type: Thermocouple Technology
- Fahrenheit Scale: -58 to 2000 F
-
Supplier: Radwell International
Description: DUAL INPUT DIGITAL THERMOMETER, HANDLES TEMPERATURES UP TO 900C (1600F), DISPLAYS T1/T2 PLUS MIN/MAX OR AVG, MEASURES J/K/T/E-TYPE THERMOCOUPLES, POWERED BY 3 AA BATTERIES. FREE 2 YEAR RADWELL WARRANTY
-
Supplier: DigiKey
Description: THERMOMETER, K-TYPE, 9 V, MINIAT
- Celsius Scale: 0.0 to 50 C
- General Features: Battery Powered
- Scale: Fahrenheit, Celsius
- Technology Type: Thermocouple Technology
-
Supplier: Yokogawa Corporation of America
Description: TX10 Series offers thermocouple thermometers that support K, J, E and T type thermocouples. There are three models available: 1-channel single-function, 1-channel multi-function, and 2-channel multi-function models. Digital Thermometers come in single
- Scale: Fahrenheit, Celsius
- Thermometer Type: Digital Thermometer
-
Supplier: DigiKey
Description: INFRARED THERMOMETER, TYPE K, -6
- Celsius Scale: 0.0 to 50 C
- General Features: Battery Powered
- Scale: Fahrenheit, Celsius
- Technology Type: Thermocouple Technology, Thermal Pyrometer / Detector
-
Supplier: SKF/Global
Description: SKF offers fifteen K-type thermocouple probes for use with SKF digital thermometer TMTL 1400K.
- Base, Noble and Refractory Metal Type: K
- Diameter or Width Range: Up to 0.5512 inch
- Element Configuration: Single Element
- Probe Configuration: Angled Probe
-
Supplier: ValueTronics International, Inc.
Description: and energy audits, science experiments, semiconductor technology manufacturing, and circuit terminal testing. Used and refurbished test equipment thermometers log data in Fahrenheit and Celsius and use an easy-to-read digital display screen. ValueTronics has thermocouple, infrared,
-
Supplier: ValueTronics International, Inc.
Description: and energy audits, science experiments, semiconductor technology manufacturing, and circuit terminal testing. Used and refurbished test equipment thermometers log data in Fahrenheit and Celsius and use an easy-to-read digital display screen. ValueTronics has thermocouple, infrared,
-
Supplier: Tempco Electric Heater Corporation
Description: Type J or K Thermometers with single or dual input, with direct or differential measurements to 0.1 deg
- Digital Technology Type: Thermocouple Technology
- Fahrenheit Scale: -328 to 2498 F
- Scale: Fahrenheit
-
Supplier: SensorsONE, Ltd.
Description: The 2028T portable digital thermometer is protected by a IP-67 waterproof case for use in an outside industrial environment. The LCD display has a 3 1/2 digit resolution for showing the measured temperature in degrees Celsius or Fahrenheit and also includes max/min reading storage, display
-
Supplier: OMEGA Engineering, Inc.
Description: The HH300 Series is a low cost digital thermometer, small enough to fit in your pocket. They are available in single or dual input models with standard features such as min/max reading, reading hold, and both are C to F switchable. Their temperature range is from -200 to 1370C (-328 to
- Celsius Scale Divisions: 0.1000 +/-C
- Digital Technology Type: Thermocouple Technology
- Fahrenheit Scale: -328 to 2498 F
- Fahrenheit Scale Divisions: 0.1000 +/-F
-
Supplier: Glas-Col, LLC
Description: Choose features to match application. These thermocouples, available in a variety of sizes and constructions, are for use with Glas-Col temperature controls and the digital thermometer. Thermocouples are type J unless identified differently in catalog number.
- Base Metal Type: K
- Gauge: 24
- Insulation / Sheath Material: Fiberglass
- Length: 48 inch
-
Supplier: InspectorTools
Description: Ideal for field testing providing a hard copy data Four Thermocouple type selections: K, J, T, and E Scan mode sequentially displays T1, T2, or (T1-T2) and simultaneously prints all 3 readings Max/Min/Avg readings Hi/Lo alarm settings Programmable time intervals with real time
-
Supplier: Transcat, Inc.
Description: outputs for use in calibrating thermometers, transmitters,control lers or recorders. Model 433201 for 115V Each Unit Includes Type K Thermocouple Calibration Cable Copper calibration cable 9V NiCad rechargeable battery Neckstrap AC adaptor/recharger Case NIST Certificate
Find Suppliers by Category Top
Featured Products Top
-
outputs provided by the electronics box, including 0/4 – 20 mA, 0 – 5 V, 0 – 10 V, thermocouple (type K), USB, RS485, RS232 interfaces, relay outputs (2 x optically isolated), ProfiNet, Modbus TCP, Modbus RTU Ethernet TCP and EtherNet/IP. This adaptability facilitates seamless (read more)
Browse Infrared Thermometers Datasheets for Optris Infrared Sensing, LLC -
A transmitter for temperature measurement, the P32100 plays a key role in offering universal usability for all known temperature sensors. Whether it's paired with resistance thermometers or thermocouples, its 6-mm housing with infrared interface and SIL approval make it the reliable and safe (read more)
Browse RTD Temperature Transmitters Datasheets for Knick Interface LLC
More Information Top
-
Digi Sense type K thermocouple thermometer from Cole-Parmer
Digi-Sense® type K thermocouple thermometer .
-
Temperature / Thermocouples
It is an ideal Humidity & Temperature Meter with scores of practical applications for laboratorial, industrial, Engineer and professional use.615 is Humidity meter with Air and type K thermocouple thermometer .
-
Role of hyperthermia in the protective action of clomethiazole against MDMA (‘ecstasy’)‐induced neurodegeneration, comparison with the novel NMDA channel block...
Temperature was measured by use of a digital readout thermocouple ( Type K thermometer , Portec, U.K.) with a resolution of +0.18C and accuracy of +0.28C attached to a CAC-005 Rodent Sensor which was inserted 2.5 cm into the …
-
The mechanisms involved in the long‐lasting neuroprotective effect of fluoxetine against MDMA (‘ecstasy’)‐induced degeneration of 5‐HT nerve endings in rat bra...
Temperature was measured during the 6 h following MDMA administration by means of a digital readout thermocouple ( Type K thermometer , Portec, U.K.) with a resolution of+0.18C and accuracy of+0.28C attached to a CAC-005 Rodent Sensor which …
-
Studies on the role of dopamine in the degeneration of 5‐HT nerve endings in the brain of Dark Agouti rats following 3,4‐methylenedioxymethamphetamine (MDMA or...
Temperature was measured by use of a digital readout thermocouple ( Type K thermometer , Portec, U.K.) with a resolution of +0.18C and accuracy of +0.28C attached to a CAC-005 Rodent Sensor which was inserted 2.5 cm into the …
-
A comparative study on the acute and long‐term effects of MDMA and 3,4‐dihydroxymethamphetamine (HHMA) on brain monoamine levels after i.p. or striatal adminis...
Temperature was measured using a digital readout thermo- couple ( Type K thermometer , Portec, U.K.) with a resolution of 70.11C and accuracy of 70.21C, which was attached to a CAC-005 Rodent Sensor inserted 2 cm into the rectum of …
-
3,4‐Methylenedioxymethamphetamine increases interleukin‐1β levels and activates microglia in rat brain: studies on the relationship with acute hyperthermia and...
Immediately before and up to 24 h after MDMA injection, tempera- ture was measured by use of a digital readout thermocouple ( Type K thermometer ; Portec, Wrestlingworth, UK) with a resolution of ± 0.1°C and accuracy of ± 0.2°C attached to …
-
The nNOS inhibitor, AR‐R17477AR, prevents the loss of NF68 immunoreactivity induced by methamphetamine in the mouse striatum
Temperature measurement was performed using a digital readout thermocouple ( Type K thermometer , Portec, Wrestlingworth, UK), with a resolution of ± 0.1°C and accuracy of ± 0.2°C, attached to a CAC-005 Rodent Sensor (Portec).
-
Studies, using in vivo microdialysis, on the effect of the dopamine uptake inhibitor GBR 12909 on 3,4‐methylenedioxymethamphetamine (‘ecstasy’)‐induced dopamin...
Temperature measurement was performed using a digital readout thermocouple ( Type K thermometer , Portec, UK), with a resolution of ± 0.1°C and an accuracy of ± 0.2°C, attached to a CAC-005 rodent sensor.
-
Protection against 3,4‐methylenedioxymethamphetamine‐induced neurodegeneration produced by glutathione depletion in rats is mediated by attenuation of hyperthe...
Temperature was measured by use of a digital readout thermocouple ( Type K thermometer , Portec, Wrestlingworth, UK) with a resolu- tion of ± 0.1°C and accuracy of ± 0.2°C attached to a CAC-005 Rodent Sensor which was inserted into the …