Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Shimadzu Scientific Instruments, Inc.
Description: Highly advanced on-line TOC Analyzer excels in a wide range of applications The TOC-4200 is a high-performance on-line TOC analyzer, based on the proven 680°C Catalyst-aided Combustion Technology. This established technology is featured in a large installed base of Shimadzu
- Measurement Range: 0 to 20,000 ppm
- Average Analysis Time: 4 minutes
- Process Temperature Range: 1,256 F
- Operating Temperature: 33.8 to 104 F
-
Supplier: Accuris
Description: Continuous Total Organic Carbon Analyzer
-
Supplier: Shimadzu Scientific Instruments, Inc.
Description: TOC-VWS: Wet oxidation/NDIR method, standalone TOC-VWP: Wet oxidation/NDIR method, PC-controlled Shimadzu is proud to introduce the first Heated-UV-Persulfate system that utilizes three oxidation methods for maximum oxidation efficiency. This method ensures rapid, efficient breakdown of
- Measurement Range: 0.5 to 3,500 ppm
- Accuracy: 1.5 %
- Average Analysis Time: 4 minutes
- Operating Temperature: 41 to 95 F
-
-
Supplier: SAE International
Description: The second generation International Space Station (ISS) Total Organic Carbon Analyzer's (TOCA) function is to monitor concentrations of Total Organic Carbon (TOC) in ISS water samples. TOC is one measurement that provides a general indication of
-
Supplier: Mettler-Toledo Technologies GmbH
Description: On-Line TOC Sensor with Flow Control The 4000TOCe on-line TOC sensor with flow control provides continuous, fast and reliable monitoring of TOC levels from post RO waters to point-of-use. Continuous Flow to Detect Rapid Changes Allows quick reaction to Total Organic Carbon
- Measurement Range: 0.00005 to 1 ppm
- Accuracy: 5 %
- Resolution: 0.001 Parts per Billion
- Average Analysis Time: 1 minutes
-
Supplier: Hamilton Company
Description: These syringes are for water analysis with Total Organic Carbon (TOC) analyzers. The wetted parts are stainless steel and borosilicate glass. The plungers and barrels are not interchangeable or replaceable.
- Syringe Volume: 0.05000528064848635 cc
- Pressure Rating: 1,999.9999999999998 psig
- Needle Gauge: 24
- Needle Length: 2 inch
-
Supplier: Shimadzu Scientific Instruments, Inc.
Description: The TNPC-4110 is an easy to handle and simple to maintain total nitrogen/phosphorous/carbon analyzer that is intended to be used as an automatic water analyzer for the water quality regulations, currently being prepared for implementation, governing total nitrogen
- Accuracy: 3 %
- Process Temperature Range: 32 to 104 F
- Operating Temperature: 33.8 to 104 F
- Analysis Method: Combustion, UV Fluorescence
-
Supplier: TOC Systems, Inc.
Description: StarTOC OZONE PROMOTED/HYDROXYL RADICAL oxidation method offers solutions for a wide variety of applications. The analyzer is completely automatic, with an integral Microsoft* Windows-CE computer & Touch Screen Display. It eliminates troublesome & expensive factory reprogramming required by
- Measurement Range: 10 to 20,000 ppm
- Accuracy: 3 %
- Average Analysis Time: 9 minutes
- Computer Interface: Computer Interface
-
Supplier: TOC Systems, Inc.
Description: • Five Oxidation Methods in One Analyzer • 103 Sample Stations & 1 Wash Station • Dual NDIRs • Widest Dynamic Range • Ease of operation with familiar Windows Software • Reliability Through Simplicity Unmatched Versatility & Reliability The StarTOC Automatic Benchtop analyzer is capable
- Measurement Range: 50,000 ppm
- Accuracy: 2 %
- Resolution: 50 Parts per Billion
- Average Analysis Time: 3 minutes
-
Supplier: O. I. Analytical
Description: No Description Provided
- Carrier Gas Flow: 200 ml/min
- Average Analysis Time: 20 minutes
- Process Temperature Range: 932 to 1,652 F
- Operating Temperature: 50 to 104 F
-
Supplier: Hach
Description: analyzer online and running instead of offline. Small footprint = critical wall space savings With one of the most compact analyzer footprints, this analyzer frees up wall space for other needed instruments. One instrument for multiple streams Providing the ability to monitor
- Measurement Range: 0 to 250 ppm
- Local Interface: Digital Front Panel
- Display Options: Digital Readout
- Sample Introduction: On-Line
-
Supplier: Hach
Description: breakdown of each process sample to deliver trusted results. Improve wastewater treatment process Capture changes in water quality with a direct analysis of Total Organic Carbon (contamination), Total Nitrogen and Total Phosphorus in the most challenging samples.
- Measurement Range: 0 to 10,000 ppm
- Local Interface: Digital Front Panel
- Display Options: Digital Readout
- Sample Introduction: On-Line
-
Supplier: TOC Systems, Inc.
Description: StarTOC Semi-Automatic Bench Top TOC is a low cost, accurate analyzer which utilizes components and software from the StarTOC Family of computer-controlled automated TOCs. Since operation and maintenance are extremely simple, it may be the analyzer of choice when less than 20 samples
- Measurement Range: 0 to 1,000 ppm
- Accuracy: 2 %
- Average Analysis Time: 2 minutes
- Analysis Method: Combustion, UV Persulfate Oxidation
-
Supplier: Hach
Description: Take the pain out of TOC analysis and lower your total cost of ownership Need to tust TOC results? • The QBD1200 has 95% less carryover. Inconsistent results? • Trust 2% standard deviation at 50 mg/L and 3% at 100 µg/L. Want to lower your Total Cost? • Stop wasting money. Save 60% of
- Measurement Range: 0.4 to 100 ppm
- Accuracy: 2 %
- Resolution: 3 Parts per Billion
- Local Interface: Digital Front Panel
-
Supplier: TOC Systems, Inc.
Description: StarTOC Dual Method was introduced to fully satisfy demands for measuring the total organic carbon in the most difficult industrial samples. Rugged FRP Enclosure allows direct outside installation and integral heating, cooling and purging, without requiring additional costly
- Measurement Range: 1 to 50,000 ppm
- Accuracy: 2 %
- Average Analysis Time: 6 minutes
- Computer Interface: Computer Interface
-
Supplier: Mettler-Toledo Technologies GmbH
Description: Real-time Total Organic Carbon Control The 6000TOCi on-line TOC sensor delivers reliable data to demonstrate compliance in Pharmaceutical water systems. The high performance sensor provides real-time data, internal diagnostics and reporting to easily meet audit requirements.
- Measurement Range: 0.00005 to 2 ppm
- Accuracy: 5 %
- Resolution: 0.001 Parts per Billion
- Average Analysis Time: 1 minutes
-
Supplier: O. I. Analytical
Description: No Description Provided
- Measurement Range: 0.002 to 30,000 ppm
- Average Analysis Time: 3 minutes
- Process Temperature Range: 1,256 to 1,652 F
- Operating Temperature: 50 to 113 F
-
Supplier: Real Tech, Inc.
Description: TOC PROBE Real Tech’s robust TOC submersible probe provides affordable real-time measurement of total organic carbon (TOC) and/or dissolved organic carbon (DOC) in water or wastewater. The TOC probe utilizes patent-pending technology to provide superior measurement
- Measurement Range: 0 to 6,000 ppm
- Average Analysis Time: 10 minutes
- Operating Temperature: 32 to 113 F
- General Features: Self Calibration
-
Supplier: Real Tech, Inc.
Description: The portable TOC/DOC Field Meter from Real Tech provides simple and affordable testing of organic matter in water or wastewater output as total organic carbon (TOC) or dissolved organic carbon (DOC). Operation is straight forward with accurate and repeatable
- Measurement Range: 0 to 2,500 ppm
- Operating Temperature: 32 to 113 F
- Display Options: Digital Readout
- Features: Other
-
Supplier: Hach
Description: EZ7102 Total Organic Carbon, 0 - 500 mg/L EZ7103 Total Organic Carbon, 0 - 1,000 mg/L EZ7104 Total Organic Carbon, 0 - 5,000 mg/L EZ7105 Total Organic Carbon, 0 - 10,000 mg/L EZ7120 Total Carbon, 0 - 20
- Titration Method: Autotitration
- Computer Interface Options: Computer Interface
- Local Interface: Digital Front Panel
- Display Type: Digital Readouts
-
Supplier: Linde North America, Inc.
Description: US EPA Method 25, "Determination of Total Gaseous Nonmethane Organic Emissions as Carbon;" Method 25A, "Determination of Total Gaseous Organic Concentration Using a Flame Ionization Analyzer;" Method 25B, "Determination of Total Gaseous Organic
- Concentration: 9.995 to 99.99 %
- Application / Function: Calibration Gas / Gas Standard
- Industrial Gases: Carbon Dioxide, Hydrogen, Nitrogen, Oxygen
- Supply Options: Gas Cylinder, Other
-
Supplier: Real Tech, Inc.
Description: Real Tech’s bypass TOC sensor offers a practical and affordable real-time monitoring solution for many organics monitoring applications. The sensor provides rapid, real-time measurement of TOC without the use of reagents. Benefiting from Real Tech’s innovative Split-Sense Pro technology and
- Carrier Gas Flow: 1,000 ml/min
- Average Analysis Time: 0.5 minutes
- Operating Temperature: 32 to 113 F
- Features: Other
-
Supplier: ASTM International
Description: to an exited NO2. As the excited NO2 returns to the ground state, it emits radiation that is measured photo-electrically. 1.3 Total and dissolved organic carbon analysis by Test Method D7573 can be analyzed at the same time on the same sample simultaneously using a properly
-
Supplier: SAE International
Description: conventional suite of analyzers and individual light HCs were measured using an FT-IR analyzer. PM emissions data were collected from filter samples taken before and after the DOC using gravimetric analysis, Soxhlet extraction with speciation of extracted HCs, and total
-
Supplier: AGC Chemicals Americas, Inc.
Description: paper, stone and tile protection, technical textiles and nonwovens production, exposure and resistance testing Flemion Ion Exchange Membranes: brine/membrane analysis, sample preparation, history and recordkeeping, total organic carbon (TOC) testing, induced couple plasma (ICP)
- Industry: Automotive, Chemical / Material Processing, Food / Beverage, Health Care / Medical, Nuclear / Utility, Piping / Pressure Vessel
- Test Methods: Chromatography (GC, HPLC, etc.), Infrared Spectroscopy (FTIR, etc.), Mechanical Testing, Microscopy / Metallography, Property Testing, Rheology, Thermal Analysis, UV / Vis Spectroscopy
- Capabilities: Environmental Exposure Testing, Environmental Testing and Analysis Services, Sunlight Exposure / Solar Simulation
- Features: North America, Northeast US Only, Other, United States Only
-
Supplier: AGC Chemicals Americas, Inc.
Description: paper, stone and tile protection, technical textiles and nonwovens production, exposure and resistance testing Flemion Ion Exchange Membranes: brine/membrane analysis, sample preparation, history and recordkeeping, total organic carbon (TOC) testing, induced couple plasma (ICP)
- Form: Bulk Solids / Granules
- Services Offered: Compounding, Formulation or Synthesis, Inspection & Analytical Testing, Research and Development
- Run / Batch Size: Laboratory / Bench, Pilot Scale
- Features: North America, Northeast US Only, United States Only
Find Suppliers by Category Top
Featured Products Top
-
Challenge: In the production of activated carbon, wastewater primarily originates from the soaking, washing, and regeneration processes. These wastewaters typically contain large quantities of organic substances, suspended solids, acidic or alkaline compounds, and (read more)
Browse Wastewater Treatment Equipment Datasheets for KINTEP NEW POWER -
FlowEVO PLUS and Silarex PLUS you can get even better performance and sensitivity. An example of this is in the measurement of Total Organic Compounds (TOC). Check out the performance and sensitivity. The best by far!!! (read more)
Browse Gas Sensors Datasheets for Electro Optical Components, Inc. -
Emissions monitoring for total VOC’s or carbon bed breakthrough in pollution control equipment - Flame Ionization Detectors BTU Monitoring of gaseous streams (read more)
Browse Gas Instruments Datasheets for Control Instruments Corp. -
Analyzers Combustible, toxic and oxygen monitoring in production and storage areas - SmartMaxII and Gas Sensors Emissions monitoring for total VOC’s or carbon bed breakthrough in pollution control equipment - Flame Ionization Detectors BTU Monitoring for optimum (read more)
Browse Gas Instruments Datasheets for Control Instruments Corp. -
prioritize total organic carbon (TOC), particles or bacterial loads. Fortunately, these standards can be broken down into three broad groups that align with Asahi/America's high purity pipe systems (see table 1 (read more)
Browse Piping Systems Datasheets for Asahi/America, Inc. -
measure the wide range of combustible vapors that might be present. A flame temperature type will include the widest possible range of combustible gases and vapors, including non?hydrocarbons such as hydrogen and carbon monoxide. Flammability data for organic binders may be difficult to (read more)
Browse Combustion Analyzers Datasheets for Control Instruments Corp. -
-controlled automation to manage bulk fluid transport with total precision. To handle volatile organic solvents safely, the CDS includes Nitrogen (N2) blanketing and secondary containment with automated leak detection. By combining advanced metallurgy with smart monitoring, the 316L Electropolished CDS (read more)
Browse Gas Cabinets and Distribution Systems Datasheets for Shenzhen Jewellok Technology Co., Ltd. -
commonly used to separate and analyze organic molecules and permanent gases by vaporizing compounds without inducing thermal decomposition. It is used to analyse compounds with a boiling range from nC1 to nC100, although most applications are within a narrower boiling range of nC3 to nC44. These (read more)
Browse Datasheets for Environics, Inc. -
. Furthermore, the system is compatible with industry-standard software and comes with Ommatidia Atelier, which helps users maximize the value of their data. In comparison to tools like robotic total stations, point cloud laser scanners, 3D scanners, and CMM machines, the Q1 stands out for its (read more)
Browse LiDAR Sensors Datasheets for Ommatidia LiDAR -
introduced to the lubricating oil. Here are the most common: Combustion by-products Exhaust gases (blowby gases) that leak past the piston rings, valve guides and turbocharger seals into the crankcase. These gases contain particles of carbon, water, acids (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific
Conduct Research Top
-
Right First Time Works for Public Relations, Too
, Close or Sell Five Plants How Effective Document Management Helps Accelerate Time to Market Effects of Persulfate Reagent Stability on a Total Organic Carbon Analyzer Instrument Blank Values Development and Validation of a Corona CAD Method for Simultaneous Determination of Peptides, Lipids
-
Validating On-Line TOC Analyzers for Real-Time Release
of Its PAT Solutions With CAMO s Unscrambler Technology Online Reaction Monitoring of Inprocess Manufacturing Samples by UPLC ANATEL A643a Total Organic Carbon (TOC) Analyzer PAT Answers: FDA's Final Guidance From Underperformance to Overachieving: Culture Change at Bayer Berkeley Aseptic Blow-Fill
-
Validating On-Line TOC Analyzers for Real-Time Release
Focuses on Quality Online Reaction Monitoring of Inprocess Manufacturing Samples by UPLC ANATEL A643a Total Organic Carbon (TOC) Analyzer PAT Answers: FDA's Final Guidance From Underperformance to Overachieving: Culture Change at Bayer Berkeley Aseptic Blow-Fill-Seal Technology vs. Traditional Aseptic
-
Compliance with JP 16 TOC Requirements Using the Sievers 900 and 500 RL TOC Analyzers and Standards
The first instrument requirement for the total organic. carbon test detailed by the Japanese Pharmacopeia. (JP) in the General Tests section <2.59> specifies that. the instrument be capable of measuring organic carbon. down to 0.05 mg/L (50 ppb). The Sievers 500 RL. and 900 Series TOC Analyzers
-
Validating the TOC Method for Cleaning Validation Applications in the Pharmaceutical Industry
Pharmaceutical drug manufacturers looking for gains in. quality and efficiency have led to a growing interest in. using Sievers* Total Organic Carbon (TOC) Analyzers for. cleaning validation. Most pharmaceutical or biotech. facilities currently own a TOC analyzer for compendial. USP water testing
-
Reliability of TOC Results In Ultra-Pure Water Analysis (.pdf)
The intent of this technical note is to discuss current methods of TOC (Total Organic Carbon) analysis, including their advantages and limitations in the analysis of ultrapure water. For purposes of this paper, "ultrapure" water is defined as that water in the 500 ppb (parts-per -billion) range
-
New United States Pharmacopeia (USP) Sterile Water Testing Requirements
to these monographs describe. new test requirements for Total Organic Carbon Chapter <643>. Pharmaceutical manufacturers are to prepare for these new. requirements starting August 1, 2013.1 These changes will directly. affect the validation and intended use of new or existing total. organic carbon
-
TOC Analysis in a Chemical Laboratory
The monitoring, control, and optimization of organics in these applications are generally done using the Total. Organic Carbon (TOC) method. The challenge then becomes finding a robust TOC analyzer that can handle. all samples ranging from clean steam condensate to highly contaminated brine
More Information Top
-
CO2 Capture by Absorption with Potassium Carbonate
… D.2.4 Calibration Gas Operation .......................................................117 D.3 Sample Collection................................................................................119 D.3.1 Preparation of sample vials......................................................119 D.3.2 Collecting Sample....................................................................119 D.3.3 Injecting Sample ......................................................................119 D.4 Total Organic Carbon Analyzer Operation..........................................121 D.4 …
-
The use of carbon mass balances in the study of biological oxidation
The total organic carbon analyzer was used for carbon balance determinations and illustrative examples taken from studies of biological oxidation toxicity to cupric ion.
-
A novel high‐temperature combustion based system for stable isotope analysis of dissolved organic carbon in aqueous samples. II: optimization and assessment of...
METHODS A high‐temperature combustion Total Organic Carbon analyzer was interfaced with continuous flow isotope ratio mass spectrometry (TOC/IRMS) for the simultaneous analysis of the bulk DOC concentration and δ13C signature.
-
Nitrogen and Carbon Dynamics and the Role of Enchytraeid Worms in Decomposition of L, F and H Layers of Boreal Mor
Dissolved inorganic carbon in soil solution, Rhizon sampler with 0.1 μm cut-off, total organic carbon analyser OCad .
-
https://helda.helsinki.fi/bitstream/handle/10138/28025/chemical.pdf?sequence=1
To achieve better a time resolution for the WSOC and ion measurements, a particle-into-liquid sampler (PILS) was coupled with a total organic carbon analyzer (TOC) and two ion chromatographs (IC).
-
http://repositories.lib.utexas.edu/bitstream/handle/2152/3557/chen_eric.pdf?sequence=6
453 Appendix J: Standard Operating Procedure for Shimadzu 5050A Total Organic Carbon Analyzer ....................................................................................................
-
Functions of Natural Organic Matter in Changing Environment
The carbon content in different fractions of soil organic matter was quantified using a total organic carbon analyzer .
-
Environmental Biotechnology and Materials Engineering (2013)
Appratus: pH meter, electronic balance, ultraviolet-visible spectrophotometer, table high speed centrifuger , automatic powder X-ray diffraction, scanning electron microscopy (SEM), analytical balance, muffle furnace, magnetic stirrer (HJ-4B), TOC5000A total organic carbon analyzer .
Indicates content that may require registration and/or purchase.