Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Aalborg Instruments
Description: Design Features rib-guided or fluted metering tubes facilitate stable and accurate readings interchangeability of flowtubes and floats manifolding at inlet or outlet (optional) ease of installation and exchange of flow tubes "non-rotating" adapter feature - glass flow tubes are
- Pipe Diameter: 0.125 to 0.25 inch
- Operating Temperature: 250 F
- Operating Pressure: 0 to 200 psi
- Media Temperature: 32 to 250 F
-
Supplier: ifm electronic gmbh
Description: Reliable detection of flow and medium temperature Suitable for water, oils and glycol solutions For installation in pipes With two scalable analogue outputs Clearly visible 4-digit LED display phase-out article Discontinuation date: 12/31/2025 Alternative articles: SU9030 +
- Media Temperature Range: 14 to 176 F
- Liquid Volumetric Flow Rate: 52.84 GPM
- Operating Pressure: 232.06032 psi
- Operating Temperature: 14 to 140 F
-
Supplier: ifm electronic gmbh
Description: Precise measurement of flow, consumption and medium temperature High accuracy, repeatability and measurement dynamics With two precise analogue outputs Clearly visible 4-digit LED display phase-out article Discontinuation date: 03/31/2026
- Media Temperature Range: 14 to 194 F
- Liquid Volumetric Flow Rate: 79.3 GPM
- Operating Pressure: 232.06032 psi
- Operating Temperature: 14 to 140 F
-
-
Supplier: Malema Sensors
Description: Features Fluid measurement performance is independent of fluid properties; eliminating the need to calibrate on different fluids Accuracy unaffected by flow regime (e.g., laminar or turbulent flow) or variations in flow velocity profile Sensors operate and measure in
- Pipe Diameter: 0.375 inch
- Media Temperature Range: 59 to 104 F
- Operating Pressure: 80 psi
- Mass Flow Rate: 0.0011025 to 11.025 lbs/min
-
Supplier: Hoffer Flow Controls, Inc.
Description: The unique design of Hoffer’s Oval Gear meter incorporates two SMOOTH (toothless) oval gears 90 degrees out of phase. The measurement gears are held together by two timing gears. The timing gears have a pitch diameter equal to the outside diameter of the measurement
- Pipe Diameter: 1 inch
- Media Temperature Range: -20 to 375 F
- Liquid Volumetric Flow Rate: 0.02 to 25 GPM
- Operating Pressure: 3,000 psi
-
Supplier: Clark Solutions
Description: The measuring mechanism in the DV04 flow meter consists of a pair of gearwheels that are driven by the fluid stream, much like a gearwheel pump. The measuring mechanism is supported by sleeve bearings or ball bearings. Two antimagnetic sensors, with a relative phase
- Pipe Diameter: 0.125 to 1.5 inch
- Media Temperature Range: -22 to 302 F
- Liquid Volumetric Flow Rate: 0.002112 to 184.8 GPM
- Operating Pressure: 4,568.68755 to 5,801.508 psi
-
Flow Computers, Totalizers, and Indicators - Portable Doppler Ultrasonic Flow Meter -- FD613 / FD614Supplier: OMEGA Engineering, Inc.
Description: The FD610 Series ultrasonic flow meter features advanced Trans-Phase measuring technology, providing accurate and reliable flow velocity assessments in closed piping systems. The FD610 Series utilizes a non-invasive clamp-on transducer which is placed on the outside of a
- Number of Inputs: 1 inputs
- Number of Control Outputs: 1 outputs
- Operating Temperature: -40 to 180 F
- Outputs: Analog Current
-
Supplier: ASTM International
Description: the sensible and latent heat storage capacity for products incorporating phase-change materials (PCM). 1.2.1 The storage capacity of a PCM is well defined via four parameters: specific heats of both solid and liquid phases, phase change temperature(s) and phase change
-
Description: natural gas, and ethane. Included are flow measurement performance requirements for meters of two accuracy classes suitable for applications such as custody transfer and allocation measurement. ISO 17089-1:2010 specifies construction, performance, calibration, and output
-
Supplier: CSA Group
Description: natural gas, and ethane. Included are flow measurement performance requirements for meters of two accuracy classes suitable for applications such as custody transfer and allocation measurement. ISO 17089-1:2010 specifies construction, performance, calibration, and output
-
Supplier: Watson Marlow Pumps Group
Description: elements Twin rollers give higher flow, four rollers give lower pulsation IP55 protection, 24 hour-duty rated Compact, portable design Two-year comprehensive warranty Value for Life: The lowest cost of ownership 0.55kW and 0.75 kW 3-phase 50/60Hz industrial motor/gearbox Eex-d
- Maximum Discharge Flow: 4.9 GPM
- Maximum Discharge Pressure: 60 psi
- Power Source: AC Powered
- Pump Type: Injection Pumps, Metering Pumps, Peristaltic Pumps, Positive Displacement Pumps, Self-Priming Pump
-
Supplier: CSA Group
Description: displacement meters in the metering of two-component mixtures of the same phase such as water and oil. It is not applicable to two-phase flow when gases or solids are present under metering conditions (i.e. two-phase flow). It can be
-
Description: the standards is presented. Key features: Explains the physical mechanism of energy flow under different conditions: single- and three-phase, sinusoidal and nonsinusoidal, balanced and unbalanced systems Starts at an elementary level and becomes more complex, with six core chapters and
-
Supplier: NETZSCH Premier Technologies LLC
Description: offers you investment security right from the beginning. Technique Technical details of the premix vessels GammaVita Type ABF und ABW The premix vessel GammaVita Type ABF designed for a fat phase and is mostly equipped with a two-zone heating and an additional grinding head. The premix
- Capacity: 0.35314657269815464 to 353.1465726981546 cubic feet
- Mixer Type: Agitator, Rotor-Stator
- Display Type: Analog Meter
- Operating Condition: Batch Operation
-
Supplier: OMEGA Engineering, Inc.
Description: to 10 Vdc, or 4 to 20 mA analog signals. The unique design of the FTB-3000 oval gear meter incorporates two smooth (toothless) oval gears positioned 90 degrees out of phase. The measurement gears are held together by two timing gears. The standard meter contains no
- Pipe Diameter: 1 inch
- Media Temperature Range: 302 to 348.8 F
- Liquid Volumetric Flow Rate: 2 to 25 GPM
- Operating Pressure: 3,000 psi
-
Description: ISO/TR 11583:2012 describes the measurement of wet gas with differential pressure meters. It applies to two-phase flows of gas and liquid in which the flowing fluid mixture consist of gas in the region of 95 % volume fraction or more. ISO/TR 11583:2012 is an extension of
-
Supplier: ASME
Description: included in this technical report: o Definition of terms o The significance of two-phase flow patterns to wet gas meter applications o Practical industrial problems that occur when applying the wet gas flow metering technologies o Uncertainty associated with wet
-
Supplier: ASME Standards and Certification
Description: included in this technical report: o Definition of terms o The significance of two-phase flow patterns to wet gas meter applications o Practical industrial problems that occur when applying the wet gas flow metering technologies o Uncertainty associated with wet
-
Supplier: CSA Group
Description: systems method. Ratings are obtained as follows: a) source flow ripple (in the standard "Norton" model) amplitude, in cubic meter per second[m3/s], and phase, in degree, over 10 individual harmonics of pumping frequency; b) source flow ripple (in the modified model)
-
Supplier: Watson Marlow Pumps Group
Description: elements Twin rollers give higher flow, four rollers give lower pulsation IP55 protection, 24 hour-duty rated Compact, portable design Two-year comprehensive warranty Value for Life: The lowest cost of ownership 0.55kW and 0.75 kW 3-phase 50/60Hz industrial motor/gearbox Eex-d
- Maximum Discharge Flow: 4.9 GPM
- Maximum Discharge Pressure: 60 psi
- Power Source: AC Powered
- Pump Type: Injection Pumps, Metering Pumps, Peristaltic Pumps, Positive Displacement Pumps, Self-Priming Pump
-
Supplier: Watson-Marlow Fluid Technology Group
Description: There is a choice of speeds: 77 rpm and 251 rpm Flow rates from 0.1 litre/min to18 litre/min Other speeds are available on request 621FX Duplex fixed speed drives have twin pumpheads allowing two channel pumping. There is a choice of speeds: 69 rpm and 183 rpm Flow rates to
- Maximum Discharge Flow: 0.0026400000000000004 to 5.016 GPM
- Maximum Discharge Pressure: 30 to 60 psi
- Discharge Size: 0.25196864 to 0.6692917 inch
- Power Source: AC Powered
-
Supplier: LS Industries
Description: x 62" long Two analog amp-meters Two 10 HP motors on two shot impellers
- Power: 10 HP
- Machine Mounting: Blast Cabinet / Enclosure, Floor / Skid
- Operation: Cleaning / Surface Preparation, Descaling / Stripping
- Abrasive Feed: Dry / Air
-
Supplier: Sunnen Products Company
Description: facilities doing resurfacing and repair of actuators for construction, mining, farming and forestry equipment. It is also ideal for applications such as flow tube/meter run cleanup, extruder tube repair and other low stock removal jobs. The HTA Series is available in two models:
- Power: 3 HP
- AC Voltage & Phase: 460 / 480 V 60 Hz, 50 Hz / International Power, Three-Phase
- Automation / Material Handling: Automatic / Indexing, PLC
- Applications / Material Abraded: Automotive, Metals / Metalworking
-
Supplier: CECOR
Description: The CECOR CE10 60/60 and 100/100 gallon are the smallest single-phase electric combination units. The CE10 offers a deep vacuum, generating a suction lift of 17″ of Hg (mercury) or 231″ (6 meters) water. Deep vacuum sucks up sump contents in minutes – contents flow through the
-
Supplier: Laurel Electronics LLC
Description: quadrature accepts A & B quadrature encoder signals to provide an analog output that tracks position, length, angle, or rate. The A & B quadrature signals are 90° out of phase, and their phase relationship determines whether up counts (+) or down counts (-) are produced. One,
- Operating Temperature: -40 to 158 F
- Direction: Bi-directional Counter
- Output / Interface: Current, Ethernet, Voltage
- Mounting: DIN Rail Mount
-
Supplier: Laurel Electronics LLC
Description: and RS232/RS485 output transmitter for quadrature accepts A & B quadrature encoder signals to provide an analog output that tracks position, length, angle, or rate. The A & B quadrature signals are 90° out of phase, and their phase relationship determines whether up counts (+) or down
- Operating Temperature: -40 to 158 F
- Direction: Bi-directional Counter
- Output / Interface: Current, Serial, Voltage
- Mounting: DIN Rail Mount
Find Suppliers by Category Top
Featured Products Top
-
regardless of flow conditions. The robust design guarantees durability, making it suitable for even the most challenging industrial environments. Unlike conventional flow meters, this mass flow meter accurately measures all types of media, including gases, liquids, two-phase, and three-phase (read more)
Browse Flow Meters Datasheets for Holykell Technology Company Limited -
Generally, one-way flow, inline flow meters have an integral check valve assembly that prevents the oil from flowing in reverse. This feature is safe when testing hydraulic pumps, but creates a potential hazard when testing double-acting cylinders and reversible motors. Due (read more)
Browse Flow Meters Datasheets for HydraCheck Inc. -
The Lee Company’s Dual Metering Flow Control valve is a two way restrictor that allows a designer to specify a different metered flow rate in each direction. The valve is ideal for high pressure hydraulic applications with system pressures up to 3000 psi. It features all stainless steel (read more)
Browse Flow Orifices and Flow Restrictors Datasheets for Lee Co. (The) -
Delivering accurate steam flow measurement in a space-saver design, the V-Cone Steam Flow Meter from McCrometer is ideal for Campus District Energy Facilities and eliminates many of the common equipment layout problems associated with steam processes in HVAC and Electric Power Co (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
to determine mass flow rates. At their core, these meters have two primary sensors: Click to keep reading (read more)
Browse Mass Flow Meters and Controllers Datasheets for Sierra Instruments, Inc. -
electronics are located outside the process stream and are not subject to vibration from the manufacturing process. Plant Efficient Configurations Designed to fit into just about any existing process with minimal changes, the CentriFlow® Meter is available in two (read more)
Browse Solids Flow Meters Datasheets for Eastern Instruments -
The Lee Company’s High Pressure Dual Metering Flow Control valve is a two way restrictor that allows a designer to specify a different metered flow rate in each direction. The valve is ideal for high pressure hydraulic applications with system pressures up to 5000 psi. It features all (read more)
Browse Control Valves Datasheets for Lee Co. (The) -
the ultrasonic flow meter is also possible with the software. In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples (read more)
Browse Flow Meters Datasheets for PCE Instruments / PCE Americas Inc. -
With its innovative design, the V-Cone Flow Meter from McCrometer offers superior accuracy and can be installed in close proximity to pumps in crowded plant (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
With its innovative design, the V-Cone Flow Meter from McCrometer offers superior accuracy and can be installed in close proximity to pumps in crowded plant (read more)
Browse Flow Meters Datasheets for McCrometer, Inc.
Conduct Research Top
-
Flowmeters Benefit From Silicon Advances
For example, new versions of Coriolis mass flowmeters now claim the ability to measure two-phase flows and to measure viscosity directly. Ultrasonic flowmeters, which now include multiple paths to provide a far more accurate measurement, are enjoying an application renaissance. And even the lowly
-
Getting the Most from Coriolis Flowmeters in Pharmaceutical Processes
technologies are generally preferred when the flow rate to be measured is kept in a small range, the process fluid is a consistent density, and the flow rate is volumetric. There has been much recent attention given to the difficulties associated with transient flow (two-phase flow, entrained gas, slug
-
MSilica Nanoparticles Treated by Cold Atmospheric-Pressure Plasmas Improve the Dielectric Performance of Organic-Inorganic Nanocomposites
fabrication techniques such as hot. embossing and injection molding. We consider mixing in four devices that are inspired by. the DEP-based devices in [20, 21]. A pressure drop is used to. drive the flow of two parallel deionized water streams. through the devices. One stream contains beads
More Information Top
-
http://eprints.hud.ac.uk/9673/1/final_Thesis.pdf
Differential pressure devices (e.g. orifice plate and Venturi meter) have been widely used as two phase flow meters and considerable theoretical and experimental studies have been published.
-
https://dspace.lib.cranfield.ac.uk/bitstream/1826/8347/1/Arubi_Tesi_Thesis_2011.pdf
The Haimo multiphase flow meter is a combination of gas-liquid two phase flow meter and three phase water cut meter.
-
Three-phase flow measurement in the petroleum industry
… alaska.gov/ogc/MeterGuide.html accessed in January 2012 Meribout M, Al-Rawahi N, Al-Naamany A, Al-Bimani A, Al-Busaidi K and Meribout A 2010 Integration of impedance measurements with acoustic measurements for accurate two phase flow metering in case of high …
-
http://eprints.hud.ac.uk/9345/2/Yousif-Muhamedsalih-poster2010.pdf
This investigation is aimed to provide a two phase flow meter capable to measure the velocity, volume fraction and volumetric flow rate for water and solid inside multi-phase flow loop.
-
A New Technology for the Metering of Low Quality Steam
This measurement philosophy has been successfully incorporated into a two phase flow meter .
-
Installation Case Studies of the Downhole Fiber Optic Multiphase Flowmeter System
Gysling, D.L., Vandeweijer, T., and van der Spek, A.: "Development of a Permanent Downhole Two Phase Flow Meter ," paper presented at the SRI 2000 Multiphase Metering and Pumping Conference, Houston, Texas, February.
-
Downhole Fiber-Optic Flowmeter: Design, Operating Principle, Testing, and Field Installations
Gysling, D.L., Vandeweijer, A., and van der Spek, A.M.: “The Devel- opment of a Fiber Optic Two Phase Flow Meter ,” Proc., Strategic Research Inst., Multiphase Metering and Pumping Conference, Hous- ton, February 2000.
-
Field Trial of a Downhole, Fiber Optic, Two-phase Flowmeter in PDO's Nimr Field
Gysling, D.L., Vandeweijer, A., and van der Spek, A M., “The Development of a Fiber Optic Two Phase Flow Meter ”, Strategic Research Institute, Multiphase Metering and Pumping Conference, Houston Texas, February, 2000.
-
Improved Reservoir Management With Intelligent Multizone Water-Alternating-Gas (WAG) Injectors and Downhole Optical Flow Monitoring
The De- velopment of a Fiber Optic Two Phase Flow Meter .
-
Improved Reservoir Management with Intelligent Multi-Zone WAG Injectors and Downhole Optical Flow Monitoring
Development of a Fiber Optic Two Phase Flow Meter , Strategic .
Indicates content that may require registration and/or purchase.