Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: ABB Measurement & Analytics
Description: Whichever of the two measurement ranges you choose, low range (0 to 40 NTU) or higher range (0 to 400 NTU), you can benefit from reliable, accurate turbidity measurement with automatic optical cleaning and dry standard calibration verification. Data Flow-through turbidity
- Display Type: None
- Measures Turbidity: Yes
- Operating Temperature: 32 to 122 F
- Turbidity Range: 0.0 to 400 NTU (Nephelometric Turbidity Units)
-
Supplier: OMEGA Engineering, Inc.
Description: The TRH444 is a compact turbidity analysis instrument designed for precision measurement of turbidity. The meter is equipped with an advanced microprocessor that results in long-term stability over a wide range of operational conditions. With its low level precision and
- Accuracy: 0.0100 ±% Full Scale
- Battery Powered: Yes
- Built-in or Self-calibration: Yes
- Display Type: Digital Display
-
Supplier: Anton Paar
Description: A solution for the measurement of turbidity in liquids, the HazeQC ME turbidity measuring module, is provided by Anton Paar as part of a modular measuring system. The approved ratio method with measurement at three angles (transmission 0°, scattered light at 25° and
- Display Type: Digital Display
- Measures Turbidity: Yes
- Mounting / Environment: Lab / Benchtop, In-Situ / Field
- Turbidity Range: 0.0 to 400 NTU (Nephelometric Turbidity Units)
-
-
Supplier: Real Tech, Inc.
Description: Real Tech’s Turbidity sensor provides rapid real-time measurement of turbidity or total suspended solids (TSS) in water or wastewater. The sensor uses a low-cost optical technology for low maintenance operation with no consumables. The measurement principle is based on IR
- Operating Temperature: 32 to 122 F
- Water Quality Measurement Instrument: Turbidity
-
Supplier: ABB Measurement & Analytics
Description: performance Data Range Turbidity: 0 to 4000 NTU Suspended solids: 0 to 100,000 mg/l SiO2 (100 g/l) Accuracy Turbidity: <±2 % measured value Suspended solids: dependent on sample Method 90° scattered light measurement
- Display Type: Digital Display
- Electrical Output: Analog Voltage Output, Analog Current Output, Switch / Alarm Relay Output
- Maximum Suspended Solids per Liquid Volume: 0.0 to 100000 ppm
- Measures Suspended Solids: Yes
-
Supplier: Campbell Scientific, Inc.
Description: The OBS-3+ Turbidity Monitor is a submersible probe, part of our OBS® line of products that use a backscatter method to measure turbidity. The OBS-3+ operates in the range of 0 to 4000 NTU. It replaces the OBS3 on our price lists. The OBS-3+ can be used in several applications
- Accuracy: 2 ±% Full Scale
- Display Type: None
- Electrical Output: Analog Voltage Output
- Measures Turbidity: Yes
-
Supplier: Analytical Technology, Inc.
Description: ATI’s Model A15/76 Turbidity Monitor is designed to meet the needs of both municipal drinking water systems and industrial water treatment for reliable, low-range turbidity measurement. The turbidity sensor is available with either a White Light Source for EPA Method 180
-
Supplier: HF scientific
Description: Connect this Raw Water Turbidity Sensor to a PLC for seamless integration with industrial control systems. Use any computer to display data, calibrate and customize the measurement without an intermediate analyzer electronics box. A LD500 local display can be used if desired.
- Display Type: None
- Measures Turbidity: Yes
- Mounting / Environment: Other
- Operating Temperature: 23 to 122 F
-
Supplier: HF scientific
Description: 0.01 NTU at low turbidity readings and an extended range to 1,000 NTU, the Micro100 is an ideal and affordable tool for research as well as routine analytical measurements.
- Accuracy: 2 ±% Full Scale
- Display Type: Digital Display
- Electrical Output: Switch / Alarm Relay Output
- Interface Options: Serial
-
Supplier: HF scientific
Description: ratio (color correction) mode is also featured. With a resolution of 0.0001 NTU at low turbidity readings and an extended range to 10,000 NTU, the Micro1000 Turbidimeter is an ideal and affordable tool for research as well as routine analytical measurements.
- Accuracy: 2 to 10 ±% Full Scale
- Display Type: Digital Display
- Electrical Output: Switch / Alarm Relay Output
- Interface Options: Serial
-
Supplier: Endress+Hauser, Inc.
Description: installation with a wall distance greater than 8 cm (3") - Measurement under pressure to avoid degassing - Integrated temperature measurement - Permissible distance between sensor and transmitter: 200 m (660 ft) Standardized and simple: - Measurement according to EN
- Display Type: None
- Measures Turbidity: Yes
- Mounting / Environment: In-Situ / Field
- Operating Temperature: -4 to 140 F
-
Supplier: HF scientific
Description: 35 years of optical measurement expertise has allowed HF scientific to become the leader in regulatory reporting turbidimeters. The HF scientific MicroTOL Online Turbidimeter has been specifically designed to meet regulations of the EPA and ISO 7027. Features include fast and easy calibration
- Accuracy: 2 to 5 ±% Full Scale
- Display Type: Digital Display
- Electrical Output: Analog Current Output, Switch / Alarm Relay Output
- Interface Options: Serial
-
Supplier: Endress+Hauser, Inc.
Description: Turbimax W CUS 41 is a process and immersion turbidity sensor for service water and solids content measurement. The measurement is based on multi-channel technology and applies the 90° scattered light method. Your benefits: Measuring range from 0.01 FNU to 300 g
- Display Type: None
- Measures Turbidity: Yes
- Mounting / Environment: In-Situ / Field
- Operating Temperature: -4 to 140 F
-
Supplier: Endress+Hauser, Inc.
Description: Turbimax CUS51D is a process and immersion sensor for the measurement of low, middle and high turbidities and solids content. It is based on the Memosens protocol. Your benefits: Optimum adaption to your measuring tasks: The optics integrated in the sensor head
- Display Type: None
- Measures Turbidity: Yes
- Mounting / Environment: In-Situ / Field
- Operating Temperature: -4 to 140 F
-
Supplier: Endress+Hauser, Inc.
Description: CUM223 is a transmitter for turbidity and suspended solids mesurement. The modular design of the transmitter allows easy adaption to a variety of customer requirements. Starting with the basic version for "measurement and alarm generation", the transmitter can be equipped with
- Built-in or Self-calibration: Yes
- Display Type: Digital Display
- Electrical Output: Analog Voltage Output, Analog Current Output, Switch / Alarm Relay Output
- Maximum Suspended Solids per Liquid Volume: 0.0 to 9999 ppm
-
Supplier: Hach
Description: The Surface Scatter 7 sc High Range Turbidimeter offers superior performance across a measurement range of 0 to 9999 NTU. The Hach Surface Scatter 7 sc Turbidimeter (SS7) is the original non-contact turbidimeter. This design minimizes sensitivity loss due to high turbidity samples; in
- Measures Turbidity: Yes
- Mounting / Environment: Panel, Other
- Turbidity Range: 0.0 to 9999 NTU (Nephelometric Turbidity Units)
-
Supplier: Hach
Description: The TU5 Series platform employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability between measurements. For the first time you will be able to remove uncertainty of which
- Display Type: Digital Display
- Measures Turbidity: Yes
- Mounting / Environment: Panel, Other
-
Supplier: Peak Process Controls Inc/Sigrist
Description: Lab turbidity measurement in bottles or cuvettes for breweries/distilleries
- Controller Functionality: Yes
- Display Type: Digital Display
- Interface Options: Serial
- Measures Turbidity: Yes
-
Supplier: Accuris
Description: STANDARD TEST METHOD FOR THE CONTINUOUS MEASUREMENT OF TURBIDITY ABOVE 1 TURBIDITY UNIT (TU)
-
Supplier: American Water Works Association (AWWA)
Description: The measurement and monitoring of turbidity before, during, and after treatment is the primary subject of this training DVD for water treatment operators. Operators must know how to monitor and measure turbidity before, during, and after treatment, to learn how well the
- Modality: eLearning (Video / CBT)
- Type: Tutorial / Workshop
-
Supplier: SWAN Analytical USA, INC.
Description: Electronic transmitter/controll er for the measurement of turbidity; for wall mounting. Measuring range: 0.000 to 200 FNU/NTU with a precision of +/- 0.003 FNU or 1% of reading. For the use with Swansensor Turbiwell.
- Accuracy: 1 ±% Full Scale
- Display Type: Digital Display
- Electrical Output: Analog Current Output
- Measures Turbidity: Yes
-
Supplier: SWAN Analytical USA, INC.
Description: High precision, non-contact nephelometer based on ISO 7027 (EN 27027, DIN 38404) for the continuous measurement of turbidity in pure water, potable water, surface water treatment and effluent. Turbidimeter with sample chamber and valve for chamber drain. High precision secondary
- Accuracy: 1 ±% Full Scale
- Display Type: None
- Electrical Output: Analog Current Output
- Measures Turbidity: Yes
-
Supplier: Turner Designs, Inc.
Description: AquaFluor® is a lightweight, inexpensive, handheld fluorometer/turbidimeter ideal for field use. Its small size and durability make the AquaFluor perfect for the user who needs quick measurements away from the laboratory. Dual-channel capability allows users to measure fluorescence and
- Battery Powered: Yes
- Measures Turbidity: Yes
- Mounting / Environment: Hand Held
-
Supplier: SWAN Analytical USA, INC.
Description: High Precision Nephelometer complying with ISO 7027 (EN 27027, DIN 38404) for the continuous measurement of low level turbidity in pure and ultra pure water. Features Range: 0.000 to 100.0 FNU with a precision of ± 0.001 FNU or 1% of reading
- Accuracy: 1 ±% Full Scale
- Display Type: Digital Display
- Electrical Output: Analog Current Output
- Event Triggered: Yes
-
Supplier: Accuris
Description: STANDARD TEST METHOD FOR THE CONTINUOUS MEASUREMENT OF TURBIDITY ABOVE 1 TURBIDITY UNIT (TU) - INCLUDES STANDARD + REDLINE (PDF)
-
Supplier: SWAN Analytical USA, INC.
Description: High precision, non-contact nephelometer based on ISO 7027 (EN 27027, DIN 38404) for the continuous measurement of turbidity in feed water. Features Range: 0.000 to 200.0 FNU with a precision of ± 0.003 FNU or 1% of reading. Turbidimeter with sample
- Accuracy: 1 ±% Full Scale
- Display Type: Digital Display
- Electrical Output: Analog Current Output
- Event Triggered: Yes
-
Supplier: ASTM International
Description: 1.1 This test method covers the online and inline determination of high-level turbidity in water that is greater than 1.0 turbidity units (TU) in municipal, industrial and environmental usage. 1.2 In principle there are three basic applications for on-line measurement set ups.
-
Supplier: ASTM International
Description: 1.1 This test method covers the on-line and in-line determination of high-level turbidity in water that is greater than 1.0 turbidity units (TU) in municipal, industrial and environmental usage. 1.2 In principle, there are three basic applications for on-line measurement set ups
-
Supplier: ASTM International
Description: 1.1 This test method covers the on-line and in-line determination of high-level turbidity in water that is greater than 1.0 turbidity units (TU) in municipal, industrial and environmental usage. 1.2 In principle, there are three basic applications for on-line measurement set ups
-
Supplier: Peak Process Controls Inc/Sigrist
Description: Non-contact measurement, auto calibrating, for drinking water applications
- Built-in or Self-calibration: Yes
- Controller Functionality: Yes
- Display Type: Digital Display
- Electrical Output: Analog Current Output
-
Supplier: Peak Process Controls Inc/Sigrist
Description: In-line measurement in pipe sizes from 1" to 6"
- Controller Functionality: Yes
- Display Type: Digital Display
- Electrical Output: Analog Current Output, Switch / Alarm Relay Output
- Interface Options: Serial
-
Supplier: KROHNE Messtechnik
Description: Reliable sludge blanket measurement via optical sensor. The sludge level meter OPTISYS SLM 2100 features an accurate and reliable profile measurement of the sedimentation tank using an optical sensor which travels through all layers of the tank reading suspended solids concentration at
- Display Type: Digital Display
- Electrical Output: Analog Current Output
- Event Triggered: Yes
- Measures Turbidity: Yes
-
Supplier: Accuris
Description: STANDARD TEST METHOD FOR ON-LINE MEASUREMENT OF TURBIDITY BELOW 5 NTU IN WATER
-
Supplier: Accuris
Description: STANDARD METHOD FOR DETERMINING MCS STABILIZER CONCENTRATION IN EL2 TREATMENT SOLUTION SAMPLES BY TURBIDITY MEASUREMENT
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: range. For the higher measuring range, an additional photodiode is positioned at the opposite side; therefore, measurement is performed via the transmitted light method.
- Accuracy: 5 ±% Full Scale
- Battery Powered: Yes
- Display Type: Digital Display
- Measures Turbidity: Yes
-
Supplier: ABB Measurement & Analytics
Description: AV412 UV254 dual-channel, low- and high-range dissolved organics monitors are designed for use on potable water treatment plants. In particular, they can be used to monitor the quality of the outlet from sand and carbon filters to provide a THM precursor measurement. Long term field trials
- Display Type: Digital Display
- Electrical Output: Analog Current Output, Switch / Alarm Relay Output
- Measures Turbidity: Yes
- Mounting / Environment: Panel, Other
-
Supplier: ASTM International
Description: 1.1 This test method is applicable to the on-line measurement of turbidity under 5 nephelometric turbidity units (NTU) in water. 1.2 It is the user's responsibility to ensure the validity of this test method for waters of untested matrices. 1.3 In this test method calibration
-
Supplier: optek-Danulat, Inc.
Description: The Haze Control is a powerful, microprocessor-based photometric converter. The Haze Control is built off the C4000 design, but has been engineered specifically for high precision haze (turbidity) measurements. The Haze Control converter operates with the optek DTF16 (11°/90° scattered
- Controller Functionality: Yes
- Display Type: Video Display
- Electrical Output: Analog Voltage Output, Analog Current Output, Switch / Alarm Relay Output
- Interface Options: Serial
-
Supplier: Emerson Automation Solutions – Rosemount
Description: to prevent erroneous turbidity readings. The Clarity II™ turbidimeter incorporates the popular and easy to use Model 1056 analyzer. The Model 1056 analyzer features a large display with easy to read process variables, a modular design with slide-in measurement boards, and extensive
- Accuracy: 2 ±% Full Scale
- Display Type: Video Display
- Electrical Output: Analog Current Output, Switch / Alarm Relay Output
- Measures Turbidity: Yes
-
Supplier: Emerson Automation Solutions – Rosemount
Description: data and diagnostics for on-screen viewing or download via a USB 2.0 data port The T56 Clarity II™ turbidimeter system is intended for the determination of turbidity in water. Low stray light, high stability, efficient bubble rejection, and a display resolution of 0.001 NTU make
- Accuracy: 2 ±% Full Scale
- Display Type: Video Display
- Electrical Output: Analog Current Output, Switch / Alarm Relay Output
- Measures Turbidity: Yes
-
Supplier: optek-Danulat, Inc.
Description: The model AF45-EX is a single channel UV absorption sensor with an additional lamp reference channel. The sensor is designed for inline operation and provides accurate concentration measurements with great repeatability, linearity and resolution. The AF45-EX can be used in hazardous
- Display Type: None
- Filters: Yes
- Measures Turbidity: Yes
- Mounting / Environment: Other
-
Supplier: optek-Danulat, Inc.
Description: The model AF46-EX is an advanced, dual channel UV absorption sensor with two additional lamp reference channels. This sensor is designed for inline operation and provides accurate concentration measurements with great repeatability, linearity and resolution. The AF46-EX can be used in
- Display Type: None
- Filters: Yes
- Measures Turbidity: Yes
- Mounting / Environment: Other
-
Supplier: optek-Danulat, Inc.
Description: The model AF46 is an advanced, dual channel Ultraviolet (UV) absorption sensor with two additional lamp reference compensation channels. This sensor is designed for inline operation and provides accurate measurements with great repeatability, linearity and resolution. The AF46 is used for
- Display Type: None
- Filters: Yes
- Measures Turbidity: Yes
- Mounting / Environment: Other
-
Supplier: Emerson Automation Solutions – Rosemount
Description: The Model 56 Analyzer offers single or dual sensor input with an unrestricted choice of dual measurement combinations. The high resolution full-color display gives unsurpassed visibility and functionality for liquid analytical instrumentation. High resolution full-color screen: easily viewed
- Controller Functionality: Yes
- Display Type: Digital Display
- Electrical Output: Analog Current Output
- Measures Turbidity: Yes
-
Supplier: CSA Group
Description: ISO 7027-1:2016 specifies two quantitative methods using optical turbidimeters or nephelometers for the determination of turbidity of water: a) nephelometry, procedure for measurement of diffuse radiation, applicable to water of low turbidity (for example drinking water); b
Find Suppliers by Category Top
Featured Products Top
-
Total cell density measurement by the Dencytee sensor is based on optical density, commonly known as the turbidity of a suspension at near-infrared (NIR) wavelengths. All particles and molecules that scatter the NIR light will be detected. This optical density signal can be correlated to (read more)
Browse Conductivity Electrodes Datasheets for Hamilton Company -
. “With results like this, online viable cell monitoring will become standard within five years.” For total cell density measurement, Hamilton’s Dencytee sensor offers a significant improvement over traditional classical turbidity sensors. As the cells grow (read more)
Browse Dissolved Oxygen Sensors Datasheets for Hamilton Company -
Ultrameter II line. The 6PFCE features the same stability and accuracy of the 6P in conductivity, resistivity, TDS, pH, ORP and temperature measurements but with enhanced free chlorine equivalent readings developed through extensive bench testing at the Myron L Company. FCE™ directly measures ORP (read more)
Browse Water Quality Testing Instruments Datasheets for Myron L Company
Conduct Research Top
-
The Measurement of Turbidity and Suspended Solids
We say that a particular water sample is turbid when the sample is hazy or cloudy. The main effect of the haziness is that we cannot see clearly through the sample after a certain distance, as the distance over which it is possible to see clearly decreases as the turbidity increases.
-
Measurement and Control Basics, Fourth Edition
. application to analytical measurement. Three sections were also added to. Chapter 8 on photoconductive sensors, photomultiplier tubes, and turbidity. analyzers. Chapter 9 on flow measurement contains new coverage on Reynolds. Number and fluid flow profiles. The discussion of the basic principles
-
Development of a Low-Maintenance Turbidimeter
State-of-the-art turbidity meters for potable water analysis are based on the nephelometric measurement principle as described in Standard Methods and adopted by the ISO standards. Turbidity is determined by the measurement of light, scattered at an angle of 90° to the incident beam.
-
Coastal Harmful Algae Bloom Monitoring via a Sustainable, Sail-Powered Mobile Platform
dissolved organic matter (CDOM) and turbidity provided an environmental context for the blooms. While the autonomous sailboat directly adds to our phytoplankton/HAB monitoring capabilities, the package may also help to ground-truth satellite measurements of HABs if careful validation measurements
More Information Top
-
Bookshelf and Unified Agenda > Environmental Protection Agency > Office of Water > Microbial and Disinfection Byproduct Rules > [FDBKF2003110514024862843] Guid...
Chapter 3 provides information regarding approved turbidity methods, analytical issues associated with turbidimeters and turbidity measurement , quality assurance and quality control issues, and data collection and management issues.
-
States > South Carolina > State > Regulations > Chapter 61 - Department of Health and Environmental Control > [SCCR 61-58] 058 - State Primary Drinking Water R...
68) "Filter profile" is a graphical representation of individual filter performance, based on continuous turbidity measurements or total particle counts versus time for an entire filter run, from startup to backwash inclusively, that includes an assessment of filter performance while another filter …
-
States > Illinois > State > Regulations > Title 35 - Environmental Protection > Subtitle F - Public Water Supplies > Chapter I - Pollution Control Board > [35 ...
"Filter profile" is a graphical representation of individual filter performance, based on continuous turbidity measurements or total particle counts versus time for an entire filter run, from startup to backwash inclusively, that includes an assessment of filter performance while another filter is …
-
States > Nebraska > State > Regulations > Health and Human Services System > [179 NE AC] 179 - Public Water Systems
Filter profile means a graphical representation of individual filter performance, based on continuous turbidity measurements or total particle counts versus time for an entire filter run, from startup to backwash inclusively, that includes an assessment of filter performance while another filter is …
-
Code of Federal Regulations > Title 40 - Protection of Environment > Clean Water Act / Water Programs (CWA) > [40 CFR Part 141] National Primary Drinking Water...
Filter profile is a graphical representation of individual filter performance, based on continuous turbidity measurements or total particle counts versus time for an entire filter run, from startup to backwash inclusively, that includes an assessment of filter performance while another filter is …
-
Data summary report on short-term turbidity monitoring of pipeline river crossings in the Moyie River, Boundary County, Idaho: PGT-PG&E Pipeline Expansion Proj...
Turbidity Measured in the Grab Samples at Crossing #8 ..............................
-
AWWA M37 - Operational Control of Coagulation and Filtration Processes
Measurement of turbidity and the variability of the turbidity measurement .
-
Federal Register > Thursday, January 5, 2006 > [71 FR 654] National Primary Drinking Water Regulations: Long Term 2 Enhanced Surface Water Treatment Rule
This reduction must be determined using daily turbidity measurements in the presedimentation process influent and effluent and must be calculated as follows: log10 (monthly mean of daily influent turbidity)-log10 (monthly mean of daily effluent turbidity).
-
States > Delaware > State > Regulations > Title 16 - Health and Social Services > 4400 - Health Systems Protection > 4000 - Division of Public Health > 4462 - ...
"Filter Profile" means a graphical representation of individual filter performance, based on continuous turbidity measurements or total particle counts versus time for an entire filter run, from startup to backwash inclusively, that includes an assessment of filter performance while another filter is …
-
States > Massachusetts > State > Regulations > 310 - Department of Environmental Protection > [310 CMR 22] 022 - Drinking Water
Filter Profile means a graphical representation of individual filter performance, based on continuous turbidity measurements or total particle counts versus time for an entire filter run, from startup to backwash inclusively, that includes an assessment of filter performance while another filter is …