Pulse Counter Digital Counters

14 Results
VIPA SLIO Module, Function Modules -- 050-1BA00
from Yaskawa America, Inc. - Motion Division

Features. Easy Web Insterface. Every VIPA SLIO E/IP and Modbus TCP Fieldbus module has a web interface for displaying diagnostic information and status of attached modules. A simple connection of your network allows remote access to your VIPA SLIO modules. High Speed Backpland Bus. Achieve reaction... [See More]

  • Functions: Pulse Counter
  • Reset: Reset Input Available
  • Number of Functions: Single
  • Output / Interface: Voltage
Counters -- 1855974 [703DR001N-1248D from Curtis Instruments, Inc.]
from RS Components, Ltd.

Curtis 703DR001N-1248D Counter [See More]

  • Functions: Pulse Counter
  • Reset: Electrical
  • Direction: Up Count; Up
  • Display Type: Lcd
Counters -- 1855980 [703TXR002N-1248D from Curtis Instruments, Inc.]
from RS Components, Ltd.

6 digit panel mount LCD counter,12-48Vdc [See More]

  • Functions: Pulse Counter
  • Reset: Electrical
  • Direction: Up Count; Up
  • Display Type: Lcd
Counters -- 7263093 [99776610 from Crouzet]
from RS Components, Ltd.

CIM Impulse Counter 230Vac [See More]

  • Functions: Pulse Counter
  • Display Type: Wheels/Dial; Mechanical
  • Reset: Manual; Manual
  • Number of Digits: 5
Counters -- 7263110 [99776705 from Crouzet]
from RS Components, Ltd.

CIM Impulse Counter 110Vdc [See More]

  • Functions: Pulse Counter; Time Meter / Indicator (Clocks)
  • Display Type: Wheels/Dial; Mechanical
  • Reset: None; No reset
  • Number of Digits: 6
Counters -- 7263135 [99776716 from Crouzet]
from RS Components, Ltd.

CIM Impulse Counter 24Vdc [See More]

  • Functions: Pulse Counter; Time Meter / Indicator (Clocks)
  • Display Type: Wheels/Dial; Mechanical
  • Reset: Manual; Manual
  • Number of Digits: 5
Counters -- 7263144 [99776907 from Crouzet]
from RS Components, Ltd.

CIM Impulse Counter 24Vdc [See More]

  • Functions: Pulse Counter
  • Display Type: Wheels/Dial; Mechanical
  • Reset: None; No reset
  • Number of Digits: 6
DIN Counter -- FKA Series
from CARLO GAVAZZI Automation Components

24x48mm up to 2 inputs up-down counters for flush mounting. NPN, PNP or voltage inputs allow connection to any type of sensors or open collector output. The front key, which can be locked, allows fast and easy counting reset. 8 digit LCD display. 8mm digits. Reset button with locking function. [See More]

  • Functions: Pulse Counter
  • Direction: Up Count; Down Count; Bi-directional Counter; Quad
  • Number of Functions: Single
  • Reset: Remote
Full Logic Control Process Counter -- CT6000
from Electro-Sensors, Inc.

Full Logic Control Process Counter. Features. • Displays process, batch, total, and rate. • Full diagnostic functions. • Three programmable transistor. setpoint outputs and AC inputs. • Non-volatile memory. • Keypad lockout. • ETL approved to applicable UL and. CSA... [See More]

  • Functions: Arithmetic Functions; Batch Counter; Count Totalizer; Preset; Pulse Counter; Ratemeters (Tachometers)
  • Direction: Up Count; Down Count; Bi-directional Counter
  • Number of Functions: Multi
  • Reset: Remote; Manual; Auto; Separate Reset for Batch, Process, Total
Preset Counter -- NE210
from Baumer Ltd.

Measuring and processing of quality and quantity-relevant production data are cycles repeating a thousand times at machines and production facilities. By their controllers and process displays Baumer provides the task-matching, practice-oriented equipment. Process displays and tachometers enable... [See More]

  • Functions: Pulse Counter
  • Direction: Up Count
  • Number of Functions: Single
  • Reset: Manual
Totalizer -- ISI30
from Baumer Ltd.

Measuring and processing of quality and quantity-relevant production data are cycles repeating a thousand times at machines and production facilities. By their controllers and process displays Baumer provides the task-matching, practice-oriented equipment. Process displays and tachometers enable... [See More]

  • Functions: Arithmetic Functions; Pulse Counter
  • Direction: Up Count
  • Number of Functions: Multi
  • Reset: Manual
Totalizer -- ISI32
from Baumer Ltd.

Measuring and processing of quality and quantity-relevant production data are cycles repeating a thousand times at machines and production facilities. By their controllers and process displays Baumer provides the task-matching, practice-oriented equipment. Process displays and tachometers enable... [See More]

  • Functions: Arithmetic Functions; Pulse Counter
  • Direction: Up Count
  • Number of Functions: Multi
  • Reset: Manual
Totalizer -- N 208
from Baumer Ltd.

Measuring and processing of quality and quantity-relevant production data are cycles repeating a thousand times at machines and production facilities. By their controllers and process displays Baumer provides the task-matching, practice-oriented equipment. Process displays and tachometers enable... [See More]

  • Functions: Count Totalizer; Pulse Counter
  • Direction: Up Count
  • Number of Functions: Multi
  • Reset: Manual
Totalizer -- N 214
from Baumer Ltd.

Measuring and processing of quality and quantity-relevant production data are cycles repeating a thousand times at machines and production facilities. By their controllers and process displays Baumer provides the task-matching, practice-oriented equipment. Process displays and tachometers enable... [See More]

  • Functions: Pulse Counter
  • Direction: Up Count
  • Number of Functions: Multi
  • Reset: Manual