Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Thermometrics Corporation
Description: In a three wire RTD one of the wires is connected to one side of the temperature element and the remaining two wires are connected to the other side of the element.
- Technology: Copper, Nickel, Platinum, Wire Wound
-
Supplier: Newark, An Avnet Company
Description: OVP 3 WIRE RTD
-
Supplier: Classic Automation LLC
Description: No Description Provided
- Data Acquisition: I/O Module
-
-
Supplier: Dataforth Corporation
Description: lead resistance. The specifications listed are for a 3-wire connection. A 2-wire connection of the RTD to the module is also possible and is achieved by adding a jumper between pin 5 (+EXC) and pin 6 (+IN) on the terminal block and connecting the RTD leads between
- Sensed Temperature: 32 to 752 F
- Operating Temperature: -40 to 176 F
- Reference Resistance: 100 Ohms
- Output: Analog Current (e.g., 4-20 mA)
-
Supplier: Thermometrics Corporation
Description: 3 wire rtd(±0.12% at 0°C)
- Diameter or Width Range: 0.125 inch
- Sensitive Length: 0.3 inch
- # of Lead Wires Per Element: 3
- Sensor Termination Type: Bare or Insulated Lead Wires
-
Supplier: Newark, An Avnet Company
Description: RTD PROBE, 3-WIRE RTD, 6IN LENGTH 1/4 IN DIAMETER
-
Supplier: Newark, An Avnet Company
Description: 3-WIRE RTD, 18 IN. LENGTH, 3/16 IN. DIAMETER
-
Supplier: Newark, An Avnet Company
Description: STYLE 2, 3 WIRE RTD ELEMENT WITH LEAD AN
-
Supplier: Dataforth Corporation
Description: lead resistance. The specifications listed are for a 3-wire connection. A 2-wire connection of the RTD to the module is also possible and is achieved by adding a jumper between pin 5 (+EXC) and pin 6 (+IN) on the terminal block and connecting the RTD leads between
- Analog Input Channels: 1 #
- Accuracy: 0.1 % FS
- Bandwidth: 0.003 kHz
- Input Impedance: 50 Mohms
-
Supplier: Dataforth Corporation
Description: excitation is provided from the module using two matched current sources. When using a 3-wire connection, this method allows equal currents to flow through the sensor leads, canceling the effects of lead resistances.The excitation currents are small (0.25mA) which minimizes
- Analog Input Channels: 1 #
- Accuracy: 0.075 % FS
- Maximum Output: 5 volts
- Bandwidth: 0.003 kHz
-
Supplier: Dataforth Corporation
Description: Each DSCA34 RTD input module provides a single channel of RTD input which is filtered, isolated, amplified, linearized, and converted to a high-level voltage output. Signal filtering is accomplished with a five-pole filter which provides 85dB of normal-mode rejection at 60Hz and 80dB
- Analog Input Channels: 1 #
- Accuracy: 0.08 % FS
- Bandwidth: 0.003 kHz
- Common Mode Rejection Ratio: 160 dB
-
Supplier: Conax Technologies
Description: 300°F (150°C). * The terminal barrel is larger than the sheath, crimped to the sheath and filled with potting compound to prevent moisture penetration. Barrel diameter sizes: up to 4-wire probes – 0.375″, 6- and 8-wire probes – 0.500″.
- Diameter or Width Range: 0.375 to 0.5 inch
- Probe Features: Available as an Assembly
- Sensor Termination Type: Bare or Insulated Lead Wires
- Element Material: Copper
-
Supplier: Acrolab Ltd.
Description: Acrolab's A520 style Thermocouples and RTDs are a low cost tube and wire alternative to Magnesium Oxide (MgO) styles. They are available in the common calibrations for Thermocouples as well as 2, 3 or 4 wire for RTDs.
- Diameter or Width Range: 0.25 inch
- Reference Resistance: 100 Ohms (Most Common)
- # of Lead Wires Per Element: 2, 3, 4
- Sensor Termination Type: Bare or Insulated Lead Wires, Plug or Quick Connect, Screw Tabs or Lugs
-
Supplier: OMEGA Engineering, Inc.
Description: All of OMEGA's RTD elements can be supplied with additional lead wire attached to existing leads. Longer leads create more flexibility for use in many RTD probe sensor applications. The size of the potted junction between lead wire and element is kept as small as
- Operating Temperature: 450 to 900 F
- Nominal Resistance: 100 R0 @ 0° C
- Length: 0.0787402 inch
- Width / Diameter: 0.0787402 inch
-
Supplier: Electro-Sensors, Inc.
Description: 3/8-16 threaded stud probe. 3-wire Platinum Pt100 RTD output Attachment probe, sensor and cable Compatible with PLCs, meters, data acquisition, and hazard monitoring system with 3-wire Pt100 RTD- inputs Integral 1/2 in. flexible liquid-tight conduit
- Sensor Termination Type: Conduit Connector
- Features: RTD
- Process Connection: Threaded Fitting
-
Supplier: OMEGA Engineering, Inc.
Description: Model DRA-RTT-2 is a non-isolated signal conditioner that accepts 100 Ohm Platinum RTD input and converts this into a 4-20 mA process current output which is linearly proportional to temperature. These signal conditioners incorporate excellent lead wire compensation and linearization
- Analog Input Channels: 1 #
- Accuracy: 0.1 % FS
- Operating Temperature: -4 to 158 F
- Temperature Measurement Range: -4 to 158 F
-
Supplier: Chromalox
Description: 100 Ohm Platinum RTD Sensors 36" Teflon® Insulated 3-Wire Leads Standard with Subminiature MTP Series Connector
- Sensed Temperature: -328 to 446 F
- Sensitive Length: 1 inch
- Reference Resistance: 100 Ohms (Most Common)
- # of Lead Wires Per Element: 3
-
Supplier: Conax Technologies
Description: compound to prevent moisture penetration. Barrel diameter sizes: up to 4-wire probes – 0.375″, 6- and 8-wire probes – 0.500″. *T4(HT) high temperature model uses fiberglass braid insulated wire and high temperature insulation compound to achieve service temperature upper limit
- Diameter or Width Range: 0.375 to 0.5 inch
- Probe Features: Available as an Assembly
- Sensor Termination Type: Bare or Insulated Lead Wires
- Element Material: Copper
-
Supplier: Tempco Electric Heater Corporation
Description: Style 6-Rigid Straight Compression Fitting RTD Style 7-Rigid 45° Bend Compression Fitting RTD Style 8-Rigid 90° Bend Compression Fitting RTD
- Reference Resistance: 100 Ohms (Most Common)
- # of Lead Wires Per Element: 2, 3, 4
- Sensor Termination Type: Bare or Insulated Lead Wires, Plug or Quick Connect, Screw Tabs or Lugs
- Element Configuration: Double Element, Single Element
-
Supplier: OMEGA Engineering, Inc.
Description: The SA1-RTD is a surface temperature sensor that can be applied to most clean, dry surfaces. Just peel off the release sheet on the bottom of the sensor and the silicone adhesive bonds the sensor to the surface, no cements or epoxies to mix, apply and cure. The thin design of the
- Sensed Temperature: -99 to 554 F
- Reference Resistance: 100 Ohms (Most Common)
- # of Lead Wires Per Element: 3
- Probe Features: Available as an Assembly
-
Supplier: Tempco Electric Heater Corporation
Description: Melt Bolt RTD's come in three styles. Visit the Preconfigured & Stock Parts page for complete part number details and ordering information. Style RT1-Adjustable Tip Thermocouple tip immersion length can be field adjusted from flush to 2" Eliminates excess inventory Style RT2-Rigid Plug Mount
- Reference Resistance: 100 Ohms (Most Common)
- # of Lead Wires Per Element: 3
- Sensor Termination Type: Bare or Insulated Lead Wires, Flexible Conduit Leads, Other, Plug or Quick Connect
- Probe Configuration: Flexible Probe, Straight Probe
-
Supplier: Conax Technologies
Description: Characteristics: Can be programmed within second to measure temperatures within all RTD standard ranges. The RTD and resistance inputs have cable compensation for 3-wire connections. A limit can be programmed on the output signal. Mounting / Installation: Mounted
- Sensed Temperature: -328 to 1,562 F
- Reference Resistance: 10 Ohms, 100 Ohms, 1000 Ohms, 120 Ohms, 200 Ohms, 400 Ohms, 500 Ohms
- Output: Analog Current (e.g., 4-20 mA)
- Mounting Options: DIN Rail Mounting
-
Supplier: Conax Technologies
Description: Programmable within seconds to measure temperatures within all standard sensor ranges. The RTD and resistance inputs have cable compensation for 3-wire connection. Mounting / Installation: DIN Form B sensor head compatible. Supplied with 2 x M4 screws on a 33 mm(1.3”) BC
- Sensed Temperature: -328 to 1,562 F
- Reference Resistance: 10 Ohms, 100 Ohms, 1000 Ohms, 120 Ohms, 200 Ohms, 400 Ohms, 500 Ohms
- Output: Analog Current (e.g., 4-20 mA)
- Reference Material: Nickel / Nickel Alloys, Platinum
-
Supplier: Acrolab Ltd.
Description: Threaded nozzle thermocouples and RTDs are commonly used to measure the temperature of the nozzle on an injection molding machine. The A300 and A310 style is a versatile design and may be used in a wide variety of applications where space is a factor. Acrolab offers this style, as a standard,
- Diameter or Width Range: 0.25 inch
- Reference Resistance: 100 Ohms (Most Common)
- # of Lead Wires Per Element: 2, 3, 4
- Probe Configuration: Angled Probe
-
Supplier: OMEGA Engineering, Inc.
Description: This cable is great for manufacturing sensors or for use as extension wire. Available in 2, 3 and 4 wire constructions, two color codes (red/black or red/white), three insulation and jacketing materials (PFA, Fiberglass and PVC) and two conductor sizes (#24 or #26 AWG Stranded)
- Number of Conductors: 2 to 4 #
- Features: Cable Assembly, Copper and Copper Alloys, Other, Other / Specialty, Polyvinyl Chloride (PVC), Teflon®
- Application: Extender Cable
-
Supplier: Tempco Electric Heater Corporation
Description: Style 1-Adjustable Spring Bayonet RTD Insertion length adjustable from 1" to 10"One can replace several fixed-length thermocouples Forms easily to any angle Style 2-Adjustable Armor Cable Bayonet RTD Insertion length adjustable over length of armor cable One can replace several
- Sensitive Length: 0.375 to 0.357 inch
- Reference Resistance: 100 Ohms (Most Common)
- # of Lead Wires Per Element: 2, 3, 4
- Sensor Termination Type: Armor Leads, Bare or Insulated Lead Wires, Other, Plug or Quick Connect, Screw Tabs or Lugs
-
Supplier: Minco
Description: Minco miniature embedment RTDs feature a variety of mounting methods, including: spring loading or potting in drilled holes and factory applied babbitt metal tip to reduce overheating of the senors when installed in babbitt layer. They also feature standard lead wire options of PTFE
- Sensed Temperature: -58 to 392 F
- Diameter or Width Range: 0.125 inch
- Sensitive Length: 0.3 inch
- Reference Resistance: 10 Ohms
-
Supplier: Acromag, Inc.
Description: v1.1 and 2.0 compatible. Maximum cable length: 5.0 meters. Transient voltage suppression on power and data lines. USB Driver: Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system. Input (two channels): Default Configuration: Input: 100Ω Pt RTD,
- Operating Temperature: -40 to 158 F
- Reference Resistance: 10 Ohms, 100 Ohms, 1000 Ohms, 120 Ohms, 200 Ohms, 400 Ohms, 500 Ohms
- Output: Analog Current (e.g., 4-20 mA)
- Reference Material: Copper, Nickel / Nickel Alloys, Platinum
-
Supplier: Acromag, Inc.
Description: 100 ohm Pt RTD or 0-900 ohm input 4-20mA output (sink/source) 12-32V DC loop/local power USB configuration The TT231 model is a space-saving two-wire transmitter that converts a 100 ohm Platinum RTD sensor input to a proportional 4-20mA signal. Power is received from the output
- Accuracy: 0.1 % FS
- Operating Temperature: -40 to 176 F
- Temperature Measurement Range: -58 to 1,652 F
- Transmission Rate: 12,000 kbps
-
Supplier: Red Lion Controls, Inc.
Description: Analog Input Channels RTD input range: -200-850 deg C RTD overall accuracy: .05% or .5 deg C A/D resolution 16 bits (0.003%) Temperature coefficient +/- 50 ppm per °C (span and offset) RTD Type: 100 Ohm Platinum RTD Alpha: .00385 or .00392 RTD Connections: 2 or
-
Supplier: Pyromation
Description: The flexible RTD extensions illustrated below are constructed using stranded copper wire with various insulations. They are used as extension cords to provide suitable connections between sensors, jack panels, or instrumentation. Resistance temperature detectors (RTDs), also
- Sensed Temperature: -328 to 399.2 F
- Diameter or Width Range: 0.125 to 0.375 inch
- Reference Resistance: 100 Ohms (Most Common)
- # of Lead Wires Per Element: 2, 3, 4
-
Supplier: TE Connectivity
Description: Configuration Features Lead Wire Configuration : 3 Wire Single (Red / White / White) Dimensions Lead Wire Length : 914.4 MM [36 INCH ] Sheath Outside Diameter : 3.18 MM [.125 INCH ] Wire Size (AWG) : 26 Product Type Features Connection Head Type : None
- Element Material: Platinum
- Features: RTD
-
Supplier: Ultra Energy
Description: Welded Fitting RTD, Industrial Temperature Sensor, RTD. Designed for direct immersion applications where a male fitting is needed for mounting. Model 201 is a straight sheath temperature sensor. Model 203 is a Reduced Tip/Fast Response temperature sensor.
- Reference Resistance: 100 Ohms (Most Common)
- # of Lead Wires Per Element: 3
- Sensor Termination Type: Bare or Insulated Lead Wires, Other
- Element Material: Platinum
-
Supplier: Industrial Filter & Pump Mfg. Co.
Description: Resistance temperature detectors (RTD’s) use the change in the electrical resistance of a wire wound device with a positive temperature coefficient to signal a change in the temperature. As a standard, Nexthermal uses 100-ohm class B platinum wire-wound elements manufactured to
-
Supplier: Durex Industries
Description: Durex manufactures a line of multi-purpose hand held temperature probes for foodservice, industrial process, and laboratory applications. Temperaure Probe features include handles of stainless steel, Teflon, or plastic and coil cord leadwires that can be constructed to withstand ambient
- Diameter or Width Range: 0.125 to 0.375 inch
- Sensitive Length: 3 to 22.125 inch
- Reference Resistance: 100 Ohms (Most Common), 1000 Ohms, 120 Ohms
- # of Lead Wires Per Element: 2
Find Suppliers by Category Top
Featured Products Top
-
Sensor Technology IST AG has studied and dealt with this problem intensively and has developed a new sensor which is especially designed for the needs of high-precision and long-term stable measurements. 3. New 4-wire RTD by IST AG - the reference (read more)
Browse Resistive Temperature Devices (RTD) Elements Datasheets for Innovative Sensor Technology IST USA Division -
The transmitter is designed to work with 3-wire RTDs and sends the sensor data via cellular signal to service towers that, in turn, sends it to a customer cloud or to the SignalFire cloud. The information can be viewed via a computer, tablet or cell phone. Signal transmission (read more)
Browse Resistive Temperature Devices (RTD) Elements Datasheets for Pyromation -
designed to work with 3-wire RTDs and sends the sensor data via cellular signal to service towers that, in turn, sends it to a customer cloud or to the SignalFire cloud. The information can be viewed via a computer, tablet or cell phone. Signal transmission intervals can be set to various options (read more)
Browse RTD Temperature Transmitters Datasheets for Pyromation -
Conax Technologies designs and manufactures RTD assemblies for a wide variety of industries and applications, including wire-wound platinum RTD (read more)
Browse RTD Temperature Probes Datasheets for Conax Technologies -
RTD assemblies for a wide variety of industries and applications, including wire-wound platinum RTD assemblies that can be bent like a thermocouple, except in the tip portion that contains the element. Our thin (read more)
Browse RTD Temperature Probes Datasheets for Conax Technologies -
wire insulation, appropriate process connection hardware, wire termination styles, and possible use of extension grade conductors vs. thermoelement conductors for the lead wiring. Industry applications (read more)
Browse Resistive Temperature Devices (RTD) Elements Datasheets for Conax Technologies -
.12%), class A (0.06%), 1/3 class B (0.04%), and higher accuracies upon request. IST sensors are available in SMD and wired configurations, and in sizes ranging from 1.6mm to 10mm (L), and 0.8mm to 5.08mm (W). Standard sensors can be customized with a variety of wire material, length, and (read more)
Browse Resistive Temperature Devices (RTD) Elements Datasheets for Innovative Sensor Technology IST USA Division -
RTD assemblies for a wide variety of industries and applications, including wire-wound platinum RTD assemblies that can be bent like a thermocouple, except in the tip portion that contains the element. Our (read more)
Browse RTD Temperature Probes Datasheets for Conax Technologies -
equipment, usually computers, located thousands of feet away in central control areas. They accept a wide range of inputs, including millivolt, volt, milliamp, thermocouple, RTD, potentiometer, and slide wire. They operate on power from a 2-wire signal loop and modulate the (read more)
Browse Signal Conditioners Datasheets for Dataforth Corporation -
signals; they also offer 8-channel measurement of five thermocouple types including accurate cold junction compensation and linearization. All channels are individually configurable for range, alarm limits, and averaging. RTD Input Modules interface to 2- or 3-wire sensors including six RTD (read more)
Browse Data Acquisition Datasheets for Dataforth Corporation
Conduct Research Top
-
Using a 3-Wire RTD to Prevent Temperature Measurement Errors
Workers in food storage, medical monitoring and many other industries rely on RTD temperature measurements to protect their valuable inventory. CAS DataLoggers Applications Specialists offer this quick datalogging tutorial recommending 3-wire RTDs to customers to improve the accuracy
-
Lead Compensation Techniques for RTDs
compensation schemes were invented and have come to be known as 2 wire, 3 wire and 4 wire.
-
3 Ways to Troubleshoot RTD Probes on an Accsense System
Several Accsense data logger pods can connect with PT-100 RTD temperature probes to provide highly accurate measurements. These probes are 3-wire probes and can present some problems when users do the initial install. With this in mind, the Applications Specialists at CAS DataLoggers have prepared
More Information Top
-
Component assessment for IEC 61508 - a worked example
In the case of our 3 Wire RTD we can be certain by inspection that only one fault will result in loss of the measurement.
-
CR4 - Thread: 3 wire RTD explanation, K type thermocouple cold junction compensation
3 wire RTD explanation, K type thermocouple cold junction compensation .
-
CR4 - Thread: RTD temperature probes
Previous in Forum: where can i buy in the philippines a 3 wire rtd splitter?
-
CR4 - Thread: 4 Wire RTD Transmitters
I have calibrated a 3 wire RTD transmitter before but have now come across a 4 wire one, 2 reds and 2 whites and am puzzled as to how to connect up my decade box up to it?
-
CR4 - Thread: What's the Difference? 2-wire, 3-wire, 4-wire RTDs
A 3 wire RTD places the 3rd lead in the opposite side of the Bridge,thus compensating for lead resistance.
-
CR4 - Thread: where can i buy in the philippines a 3 wire rtd splitter?
where can i buy in the philippines a 3 wire rtd splitter?
-
CR4 - Thread: What is the Use of Third Wire in 3 Wire RTD?
What is the Use of Third Wire in 3 Wire RTD ?
-
CR4 - Thread: PT100 4 Wire.
The 3 wire RTD functions the same as a 4 wire RTD however, it uses one monitor wire in conjunction with one of the sensing leads to facilitate use of the feedback signal as a means of measuring the cable/wire length to …
-
CR4 - Thread: Flow meter
Next in Forum: 3 wire RTD explanation, K type thermocouple cold junction compensation .
-
CR4 - Thread: Instrument
Previous in Forum: 3 wire RTD explanation, K type thermocouple cold junction compensation .
Indicates content that may require registration and/or purchase.