Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Accuris
Description: Nitrogen Oxide Deluted in Nitrogen (1)
-
Supplier: FIS Inc.
Description: SP Series - Nitrogen Oxides Environmental Monitoring Sensor
- Gas Types: Combustible Gas, Nitrogen Oxides (NxOx)
-
Supplier: Accuris
Description: Water quality Determination of nitrogen Determination of bound nitrogen (TNb), following oxidation to nitrogen oxides
-
-
Supplier: Accuris
Description: Water quality - Determination of nitrogen - Determination of bound nitrogen (TN b ), following oxidation to nitrogen oxides
-
Supplier: Accuris
Description: Water quality \x96 Determination of nitrogen \x96 Determination of bound nitrogen (TNb), following oxidation to nitrogen oxides
-
Supplier: ASTM International
Description: This method is for simultaneously determining organically based carbon, hydrogen and nitrogen in coals, cokes, oils and other materials. The detection range for each element is 0.04 to 100 mass-%. Water contained in the samples will contribute to the hydrogen values. Solid samples containing
-
Description: Criteria for testing methods and technical parameters for geometrical features, physicaland chemical properties, and de-nitrogen oxides (DeNOx) technological properties of power plantDeNOx plate-type catalysts are established in this standard.
-
Description: The procedure is applicable to mass concentration of nitrogen monoxide present up to approximately 12,5 mg/m3 of nitrogen dioxide up to approximately 19 mg/m3 at 25 °C and 101,3 kPa.
-
Supplier: CSA Group
Description: The procedure is applicable to mass concentration of nitrogen monoxide present up to approximately 12,5 mg/m3 of nitrogen dioxide up to approximately 19 mg/m3 at 25 °C and 101,3 kPa.
-
Description: Stationary source emissions -- Determination of the mass concentration of nitrogen oxides -- Naphthylethylenediamine photometric method
-
Description: Water quality -- Determination of nitrogen -- Part 2: Determination of bound nitrogen, after combustion and oxidation to nitrogen dioxide, chemiluminescence detection
-
Description: Specimens of textiles are exposed to nitrogen oxides. Two test differing in severity are provided.
-
Supplier: CSA Group
Description: ISO 105-G01:2016 specifies two methods for determining the resistance of the colour of textiles of all kinds and in all forms to the action of nitrogen oxides produced during combustion of gas, coal, oil, etc., and when air is passed over heated filaments. The two tests differ in
-
Supplier: CSA Group
Description: Specifies the fundamental structure and the most important performance characteristics of automated measuring systems for oxides of nitrogen to be used on stationary source emissions, for example combustion plants. The procedures to determine the performance characteristics are also
-
Supplier: Linde North America, Inc.
Description: Linde has been a quality supplier of Medical Gases, mixtures and equipment for over 50 years. Linde supplies a full line of gases for therapy, calibration, biological culture growth and various diagnostic testing requirements. Our wide range of medical gases and mixtures encompasses both in vivo
- Industrial Gases: Ethylene Oxide, Nitrogen
- Product Form: Gas
- Supply Options: Gas Cylinder
- Composition: Gas Mixture
-
Supplier: ASTM International
Description: "Trace Nitrogen in Liquid Petroleum Hydrocarbons by Syringe/Inlet Oxidative Combustion and Chemiluminescence Detection," D6069, "Trace Nitrogen in Aromatic Hydrocarbons by Oxidative Combustion and Reduced Pressure Chemiluminescence Detection," and D7184,"Ultra Low Nitrogen in
-
Supplier: ASTM International
Description: 1.1 This test method covers the manual determination of the combined nitrogen dioxide (NO2) and nitric oxide (NO) content, total NOx; in the atmosphere in the range from 4 to 10 000 μg/m3 (0.002 to 5 ppm (v)). 1.2 The maximum sampling period is 60 min at a flow rate of 0.4 L/min. 1.3
-
Supplier: SAE International
Description: nondispersive infrared (NDIR) methods. Measurement of total oxides of nitrogen by chemiluminescence and NDIR methods is discussed. This SAE Recommended Practice provides for the measurement of carbon dioxide, carbon monoxide, and oxides of nitrogen in diesel exhaust.
-
Supplier: CSA Group
Description: ISO 105-G04:2016 specifies a method for determining the resistance of the colour of textiles to the action of nitrogen oxide in the atmosphere at elevated temperatures and high relative humidities. For testing at lower humidities, see ISO 105‑G01.
-
Supplier: SAE International
Description: nondispersive infrared (NDIR) methods. Measurements of total oxides of nitrogen by chemiluminescence and NDIR methods is discussed.
-
Supplier: GENERON
Description: Cargo Hold and Hull Fumigation Cargo Hold Inerting / Oxidation Control FPSO (Floating Production, Storage & Offloading Systems) LNG / LPG Transporting Perishable Goods The GENERON® Marine Series is ideal where low to medium Nitrogen flow rates are required in a small footprint. GENERON®
- Output Flow Rate: 5,831.52696 to 41,653.764 SLM
- Features & Approvals: Compressor Included
- Generator Type: Nitrogen
-
Description: This standard establishes criteria for testing methods and technical parameters for geometrical features, physical and chemical properties and DeNOx technological properties of power plant DeNOx plate-type catalyst.
-
Supplier: GFS Chemicals, Inc.
Description: ITEM#:1174 NiO CAS#:1313-99-1 F.W.:74.71 NFPA#:2-0-0 Specific Gravity: 0.000 DOT:NR Descriptions: Nickel (II) oxide. Specification TEST 1. Assay 98.0% min. 2. Chloride 0.005% 3. Nitrogen compounds 0.005% 4. Sulfate 0.01% 5. Cobalt 0.2% 6. Copper 0.02% 7. Iron 0.02% 8. Zinc 0.02%
- Features: All Non-Metals, Oxides, Transition Metals (Ti, Fe, Ni, etc)
- State of Matter: Powder
-
Supplier: Edwards Vacuum
Description: Mistral is an electrically-heated hot air oxidation unit coupled with a proven three-stage wet scrubber and self-cleaning inlets. Mistral employs a patented hydrogen inject system and is capable of removing pyrophoric and acid gases) for semiconductor applications such as polysilicon and
-
Supplier: Gelest, Inc.
Description: Safety Packaging Under Nitrogen
- Chemical System: Silicone
-
Supplier: Shimadzu Scientific Instruments, Inc.
Description: The TNPC-4110 is an easy to handle and simple to maintain total nitrogen/phosphorous/carbon analyzer that is intended to be used as an automatic water analyzer for the water quality regulations, currently being prepared for implementation, governing total nitrogen and total
- Accuracy: 3 %
- Process Temperature Range: 32 to 104 F
- Operating Temperature: 33.8 to 104 F
- Analysis Method: Combustion, UV Fluorescence
-
Supplier: GFS Chemicals, Inc.
Description: ITEM#:5596 HgO CAS#:21908-53-2 F.W.:216.59 NFPA#:4-0-0 Specific Gravity: DOT:6.1/II Descriptions: Specification TEST 1. Assay 99.0% min. 2. Insoluble in dil. HCl 0.03% 3. Residue after reduction 0.025% 4. Chloride 0.025% 5. Sulfate 0.015% 6. Nitrogen compounds 0.05% 7. Iron 0.02% Properties
- Features: All Non-Metals, Oxides
- State of Matter: Powder
-
Supplier: Gelest, Inc.
Description: Additional Properties Hydrolytic Sensitivity 2: reacts with aqueous acid Safety Hazard Info ivn mus, LD50: 100 mg/kg Packaging Under Nitrogen
- Features: Non-Metals (C, N, O, P, S), Other Metals (Al, In, Sn, Pb, etc.)
- Type: OrganoMetallics
-
Supplier: Branch Environmental Solutions
Description: reduce the operating cost compared to Direct Thermal Oxidation if the VOC is very low in concentration. Branch can help you evaluate the best choice. Some compounds containing Nitrogen (such as Ammonia) use catalytic destruction because there are specific catalyst developed to destroy Ammonia
- Required Airflow: 25,004.025 SCFM
- Oxidation Technology: Catalytic
-
Supplier: ENMET Corporation
Description: P/N 10022-1700, SDS-97D Series Sensor/Transmitter Nitrogen Dioxide, NO2 Features Non-intrusive push button calibration Excellent chemical selectivity 4-20 mA output, 24 VDC powered One-person calibration Digital display Electrochemical sensors RFI/EMI resistant Optional Precalibrated Sensor
- Electrical Outputs: Analog Current
- Display: Digital
- Gas Types: Nitrogen Dioxide (NO2)
-
Supplier: Gelest, Inc.
Description: Safety Packaging Under Nitrogen
- Features: Non-Metals (C, N, O, P, S), Other Metals (Al, In, Sn, Pb, etc.)
- Type: OrganoMetallics
-
Supplier: GFS Chemicals, Inc.
Description: ITEM#:902 CuO CAS#:1317-38-0 F.W.:79.55 NFPA#:2-0-0 Specific Gravity: 0.000 DOT:NR Descriptions: Powder Specification TEST 1. Assay 99.0% min. 2. Insoluble (in dil HCl) 0.02% 3. Carbon compounds (as C) 0.01% 4. Chloride 0.005% 5. Nitrogen compounds (as N) 0.002% 6. Sulfate 0.02% 7. Free
- Features: All Non-Metals, Oxides, Transition Metals (Ti, Fe, Ni, etc)
- State of Matter: Powder
-
Supplier: Gelest, Inc.
Description: Safety Packaging Under Nitrogen
- Viscosity: 800 to 1,000 cP
- Index of Refraction: 1.415
- Chemical System: Silicone
-
Supplier: Linde North America, Inc.
Description: gas production plants worldwide are strategically located in key manufacturing markets. This gives you the benefit of timely deliveries, flexibility and security of supply. Electronic special gases, including silane, nitrogen trifluoride, ammonia and dopant mixtures are shipped in a variety
- Application / Function: Electronic and Semiconductor
- Product Form: Gas
- Supply Options: Gas Cylinder, Other
- Industrial Gases: Nitric Oxide
Find Suppliers by Category Top
Featured Products Top
-
SCREW COMPRESSOR UNITS DELTA SCREW WITH BELT DRIVE FOR COMPRESSING AIR, NITROGEN AND OTHER NEUTRAL GASES. (read more)
Browse Air Compressors Datasheets for Aerzen USA Corp. -
) Built-in high-efficiency filter, suitable for clean rooms, semiconductors, and optical components. Nitrogen-filled tabletop oven (anti-oxidation) Can introduce nitrogen to prevent metal, copper parts, and components from oxidizing and changing color at high temperatures. (read more)
Browse Ovens (industrial) Datasheets for Guangdong Atmars Industry Co., Limited -
equally emission-intensive. In particular, they produce carbon dioxide and nitrogen oxide, two pollutants that are coming under increasingly stringent regulation by the Environmental Protection Agency (EPA). But now, with the successful introduction of the world’s first 4kV heater (read more)
Browse Industrial Heaters Datasheets for Gaumer Process -
particular, they produce carbon dioxide and nitrogen oxide, two pollutants that are coming under increasingly stringent regulation by the Environmental Protection Agency (EPA). But now, with the successful introduction of the world’s first 4kV heater, industry has the power to change its (read more)
Browse Electric Heaters Datasheets for Gaumer Process -
potentially harmful emissions. Environmental Concerns Surrounding Ships Ship emissions are a growing environmental concern as they contribute to air pollution and climate change. The emissions generated by ships include carbon dioxide (CO2), sulfur oxides (SOx), nitrogen oxides (NOx), and (read more)
Browse Datasheets for Mid-Mountain Materials, Inc. -
particulate matter and nitrogen oxides, can lead to respiratory and cardiovascular problems. Because of this, managing diesel exhaust extraction effectively is of utmost importance, especially in port environments where diesel engines power various equipment and vehicles. Here, we (read more)
Browse Coated Fabrics Datasheets for Mid-Mountain Materials, Inc. -
exhaust, such as particulate matter and nitrogen oxides, can lead to respiratory and cardiovascular problems. Because of this, managing diesel exhaust extraction effectively is of utmost importance, especially in port environments where diesel engines power various equipment and vehicles (read more)
Browse Ceramic Insulation and Textiles Datasheets for Mid-Mountain Materials, Inc. -
HASTELLOY X is a wrought nickel base alloy with excellent high temperature strength and oxidation resistance. All of the product forms are excellent in terms of forming and welding. Although HASTELLOY X is primarily noted for heat and oxidation resistance it (read more)
Browse Nickel and Nickel Alloys Datasheets for High Performance Alloys, Inc. -
embedded into the PLC logic. Jewellok-engineered systems feature automated leak detection and emergency shut-off protocols that can isolate a section of the manifold in milliseconds. Furthermore, the PLC manages Nitrogen (N2) blanketing for volatile solvents, maintaining an inert environment to prevent (read more)
Browse Gas Cabinets and Distribution Systems Datasheets for Shenzhen Jewellok Technology Co., Ltd. -
500A 1-Circuit Liquid Nitrogen Slip Ring: Ultra-Low Temperature (-196°C) High-Precision Power (read more)
Browse Slip Rings Datasheets for JiuJiang Ingiant Technology Co., Ltd.
Conduct Research Top
-
Protecting petroleum workers against sulfur dioxide and nitrogen oxides with air filters
As exploration and production activity in the U.S. petroleum industry picks up, workers may become exposed to the health risks associated with chemicals found in their workplace environments as well as petroleum products and processes themselves. However, air filtration systems can serve as much
-
How to Remove Oxides of Nitrogen from Air
Removal of Oxides of Nitrogen - N0x can be achieved by injecting Ammonia into the air and then...
-
The On-Line Detection of Oxides of Nitrogen in Light Hydrocarbon Streams
Producers of high purity monomers (ethylene) have identified the. need to measure the presence of Oxides of Nitrogen (NOX) at very. low PPB levels, and take steps to avoid potentially hazardous. conditions, in the Cold Box.
-
Tool for Detecting A Wide Range of Hazardous Gases
This instrument is mostly used to monitor the presence of polluting gases such ozone, nitrogen oxide, sulfur dioxide, and carbon monoxide but is capable of detecting numerous dangerous chemicals in the industry.
-
AdBlue (R)/DEF: Refractometric Analysis
AdBlue (R), also known as DEF, is an aqueous urea solution. It lowers nitrogen oxides in diesel emissions. International standards demand that refractive index be measured for the determination of the urea concentration in AdBlue (R).
-
Air Pollution : Ammonia and Hydrogen Sulfide and Ambient Calibration
The most common air pollutants include carbon monoxide, ground level ozone, nitrogen oxides, particulate matter, sulfur oxides, and volatile organic compounds. There are other pollutants that are important both due to their impact on the environment and on public health. We will take a look at two
-
Dry Sorbent Injection (DSI) Application Story
Background: New EPA regulations have changed the emissions standards for coal fired power plants operating in the United States forcing them to reduce their Sulfur dioxide (SO2), Sulfur trioxide (SO3), Mono-nitrogen oxides (NOx) and Mercury levels.
-
Particle Size Analysis of the Zeolite in Catalysis Industry (.pdf)
afterburning, nitrogen oxide elimination...). Zeolite is one of the most employed elements in the catalysis because of its molecular sieve power and its low cost. Its particles size has a big influence on the productivity catalyst reaction.
More Information Top
-
Basic Nitrogen Compounds
AMMONIA OXIDATION AND LOWER NITROGEN OXIDES PRODUCTION XVI.
-
Code of Federal Regulations > Title 40 - Protection of Environment > Clean Air Act / Air Programs (CAA) > [40 CFR Part 52] Approval and Promulgation of Impleme...
Action on petitions submitted under section 126 relating to emissions of nitrogen oxides .
-
HazMat Data: For First Response Transportation Storage and Security 2nd Edition Complete Document
… Vapors are heavier than air and will collect and stay in low areas Vapors in confined areas (e.g., tanks, sewers, buildings) may explode when exposed to fire Toxic products of combustion may include carbon monoxide, nitrogen oxide , and hydrogen cyanide Do …
-
Code of Federal Regulations > Title 40 - Protection of Environment > Clean Air Act / Air Programs (CAA) > [40 CFR Part 60] Standards of Performance for New Sta...
Emission guidelines for municipal waste combustor metals, acid gases, organics, and nitrogen oxides .
-
Federal Register > Tuesday, April 3, 2012 > [77 FR 20218] Secondary National Ambient Air Quality Standards for Oxides of Nitrogen and Sulfur
B. History of Reviews of NAAQS for Nitrogen Oxides and Sulfur Oxides .
-
Federal Register > Monday, August 1, 2011 > [76 FR 46084] Secondary National Ambient Air Quality Standards for Oxides of Nitrogen and Sulfur
B. History of Reviews of NAAQS for Nitrogen Oxides and Sulfur Oxides .
-
States > Wisconsin > State > Regulations > Natural Resources > Air Pollution Control > [WI AC nr 440] 440 - Standards of Performance for New Stationary Sources
19) " Nitrogen oxides " means all oxides of nitrogen except nitrous oxide, as measured by test methods set forth in this chapter or incorporated by reference in this chapter by s. NR 440.17.
-
States > Michigan > State > Regulations > Environmental Quality > Air Pollution Control > Chapter 336 > Air Quality Division > [MAC R 336d1801] Part 8 - Emissi...
(c) "Low-NOx burners" means 1 of several developing combustion technologies used to minimize the formation of emissions of nitrogen oxides .
Indicates content that may require registration and/or purchase.