Supplier: Accuris
Description: TR35 Underwater concreting
-
Supplier: Accuris
Description: Prefabricated reinforced concrete houses
-
Supplier: Accuris
Description: DECK COVERING, LATEX CONCRETE
-
-
Supplier: Rath USA Inc.
Description: Rath’s refractory castables offer a wide range of materials with the highest technical standards. Depending on the application, the concretes can withstand up to 1800°C Typical applications Whether dense and insulating castables, low-cement and cement-free castables, vibration
- Max Use: 1,100 to 1,800 C
- Cement / Raw Material Form: Concrete, Mortar
- Shape: Powder / Aggregate
-
Supplier: Accuris
Description: STANDARD TERMINOLOGY RELATING TO CONCRETE AND CONCRETE AGGREGATES
-
Supplier: ASTM International
Description: Standard Terminology Relating to Concrete and Concrete Aggregates
-
Supplier: ASTM International
Description: Rules for Inspection of Concrete and Reinforced Concrete Work (Withdrawn 1935)
-
Supplier: Titebond
Description: adhesion of these compounds to concrete, wood, tile and other sound floor coverings. When added to portland cement and a sand mixture, Titebond Concrete Primer enhances the bonding of new, wet stucco or concrete to old concrete, masonry, stucco and similar surfaces. It
- Substrate: Concrete / Masonry
- Features: Floor
- Form: Liquid
- Type: Primer
-
Supplier: Aervoe Industries Incorporated
Description: No Description Provided
- Use Temperature: 60 to 100 F
- Cure / Technology: Air Setting / Film Drying, Single Component System
- Industry: Building / Construction
- Substrate Compatibility: Concrete / Masonry
-
Supplier: Oldcastle Infrastructure, Inc.
Description: Precast pipe is offered in multiple styles including round, elliptical, perforated, gasketed and jacking with a variety of connection types available. Oldcastle Precast pipe is designed to meet ASTM C-76, ASTM C-443, AASHTO M170, and APWA specifications. Piping can be used in virtually any project
- Diameter: 12", 18", 24", 30", 36"
- Material: Concrete
- Features: Other Size >36"
- Shape: Round
-
Supplier: Miller Fall Protection / Honeywell
Description: Concrete D-Bolt Anchorage Connector (417C/) includes a 5/8-in. (16 mm) stud-type expansion anchor that is ideal for applications with concrete and lightweight concrete that meet required specifications (min. 2,000 psi [13.8 MPa]). Can be installed on a vertical wall or overhead
- Type: Anchorage Connectors
-
Supplier: Ebinger Manufacturing Corp.
Description: ANCHOR LENGTH 12 INCH ANCHOR SIZE 3/4 INCH WEIGHT 35 LB PER BOX PACKAGING QUANTITY 20 PER BOX INCLUSIONS/FEATURES NUTS AND WASHERS
- Hole Size (Diameter): 0.75 inch
- Length: 12 inch
- Types: Concrete Anchors (Anchor Bolts)
-
Supplier: R. S. Hughes Company, Inc.
Description: Devcon brown asphalt & concrete sealant with a 48 hr cure time. This asphalt & concrete sealant is waterproof. Provides a 60 min working time. Works in a mix ratio of 2:1. Maximum operating temperature is +250 F. Perfect for patching applications.
- Use Temperature: 250 F
- Features: Leveling / Filling Compound
-
Supplier: Miller Fall Protection / Honeywell
Description: The Disposable Concrete Anchor Strap (8185CX) is uniquely designed to provide temporary anchorage on concrete forms. Constructed of 1-3/4-in. (44 mm) wide, abrasion-resistant webbing. Forged steel D-ring (8185C) is capable of withstanding 5,000 lbs. (22 kN). Standard lengths of 2-ft.
- Type: Lanyards / Straps
-
Supplier: United Bio Lube
Description: No Description Provided
- Kinematic Viscosity (@ 40°C): 8 cSt
- Industry Applications: Automotive / Transportation, MIL-SPEC / Military, Machine / Gears, Marine
- Features: Biodegradable, Lubricant, Specialty, Specialty / Other
- Functions: Corrosion Inhibitor / Rust Preventative, Mold Release / Release Agent
-
Supplier: CSA Group
Description: ISO 1920-7:2004 specifies non-destructive test methods for use on hardened concrete. The methods included are: a) determination of rebound number; b) determination of ultrasonic pulse velocity; and c) determination of pull-out force.
-
Description: ISO 1920-7:2004 specifies non-destructive test methods for use on hardened concrete. The methods included are: a) determination of rebound number; b) determination of ultrasonic pulse velocity; and c) determination of pull-out force.
-
Supplier: Gilson Company, Inc.
Description: Concrete Reference Thermometer checks calibration of other devices used for temperature determinations in cement and concrete. Meets ASTM C 1064 and E 77. Mercury-filled with black engraved numbers against yellow background. Calibrated for 3in (76mm) immersion and includes a
-
Supplier: Norton Abrasives
Description: Sharp, coarse grit silicon carbide abrasive provides a economical cost solution for cutting brick, block, concrete on walk behind saws
- Outer Diameter (OD): 14 inch
- Bore ID / Shank Diameter: 1 inch
- Thickness: 0.1875 inch
- Grit Size: 24 # or Microns
-
Supplier: Norton Abrasives
Description: Sharp, coarse grit silicon carbide abrasive provides a economical cost solution for cutting brick, block, concrete on high-speed saws
- Outer Diameter (OD): 14 inch
- Bore ID / Shank Diameter: 1 inch
- Thickness: 0.125 inch
- Grit Size: 24 # or Microns
-
Supplier: KOSTER American Corporation
Description: VAP I® ORS C is a 2-component, VOC Compliant, Low viscosity, High Solids Epoxy used in conjunction with the ORS Detergent to coat concrete slabs contaminated with Oil Based Hydrocarbons. Cures in about 12 hours.
- Type: Cleaner / Cleaning Agent
-
Supplier: CSA Group
Description: has been added. (h) Annex C of CSA A231.2: Was added to highlight the issues related to the use of segmental concrete units that don't meet the aspect ratio requirements for concrete pavers. CSA gratefully acknowledges the contribution of the Interlocking Concrete Pavement
-
Supplier: Weiss Technik North America, Inc.
Description: Cement & Concrete Test Chamber – Reliable Testing Equipped with both dry and submerged storage Stainless steel construction workspace area accessible through large fully hinged doors. Removable stainless steel wire shelves and 6”-deep removable cement curing trays Top tanks fully equipped
- Temperature Control: Cooling
- Features: Shelves
-
Supplier: AMICO
Description: Structures around the world have foundations and other design elements that require concrete. StayForm is the most cost effective solution for forming bulkheads, tunnels or any below-grade structure. StayForm is easy-to-cut when forming construction joints, keyways and curved shapes, saving
-
Supplier: CSA Group
Description: ISO 16311-2:2014 describes general requirements and procedures for the assessment of concrete structures. The assessment can be initiated under the following circumstances, but not limited to: a) an anticipated change in use or extension of design service life; b) structural deterioration due
-
Supplier: American Welding Society (AWS)
Description: Explains metalized zinc cathodic protection systems for corrosion protection of concrete structures with steel reinforcing. A publication useful to departments of transportation, port facilities, power plants, and other operations responsible for repair and maintenance of concrete
-
Supplier: InspectorTools
Description: thermo-hygrometer that measures ambient Temperature and RH and calculates Dew point and GPP. Relative Humidity is a crucial factor to consider when installing a floor over a concrete sub floor. The RH sensor of TotalCheck is removable and conforms to the ASTM F-2170 standard to determine if
-
Supplier: Hubbell Electrical Products
Description: OCTAGON TYPE PRE-GALVANIZED STEEL MATERIAL 3 INCH UL 514A, CSA C22.2 APPROVAL 37 CU INCH CAPACITY (3/4 INCH TO 1 INCH) SINGLE ROW SIDES KNOCKOUT SIZE 8 KNOCKOUT(S) APPLICABLE STANDARD ANSI, NEMA OS1
- Depth: 3 inch
- Features: Knockouts
- Material: Steel
- Type: Terminal and Junction Boxes
-
Supplier: UL Standards & Engagement
Description: 1.1 These requirements cover concrete masonry units classified for use in fire resistive walls in accordance with the conditions of acceptance of the Standard for Fire Tests of Building Construction and Materials, UL 263. 1.2 Concrete masonry units are classified as follows: a) 2-hour
-
Supplier: TelephoneStuff.com
Description: Large Capacity Concrete Recessed Stamped Steel Floor Box is a recessed multi-service floor box that offers unsurpassed capacity while maintaining separation of power from low voltage cables. Concrete Recessed Floor Box Features: - Stamped Steel Floor Box is fully adjustable - Service
- Material: Steel
-
Supplier: American Welding Society (AWS)
Description: This AWS standard is a specification for thermal spraying zinc anodes on steel reinforced concrete. This standard is formatted as an industrial process instruction. The scope includes: job description, safety, pass/fail job reference standards, feedstock materials, equipment, a step-by-step
Find Suppliers by Category Top
Featured Products Top
-
(C1797, Specification for Ground Calcium Carbonate and Aggregate Mineral Fillers for Use in Hydraulic Cement Concrete) was developed by ASTM International’s committee on concrete and concrete aggregates (C09). ASTM member Caroline Talbot (read more)
Browse Standards and Technical Documents Datasheets for ASTM International -
Federal Signal Corporation - Industrial Signaling and Systems
Are duty cycles burning out your audible horns?
installation on walls, panels, 4-inch square outlet boxes, cabinets, or deep concrete wall constructions. A Double Projector accessory (Model PR2) mounted on the front of the unit directs side sound output, optimizing signaling for long, narrow rooms or corridors. The 450E is UL, cUL and ULC Listed and (read more)
Browse Audible Alarms Datasheets for Federal Signal Corporation - Industrial Signaling and Systems -
Rated CSFM Approved UL and cUL UL Fire Listed and ULC Canadian Fire (read more)
Browse Audible Alarms Datasheets for Federal Signal Corporation - Industrial Signaling and Systems -
transmission without signal interruption or contact failure under heavy-duty working conditions. -40°C Extreme Temperature Stability: Wide operating temperature range of -40°C to +65°C maintains consistent electrical performance in cold regions, high-altitude sites, and (read more)
Browse Slip Rings Datasheets for JiuJiang Ingiant Technology Co., Ltd. -
) by (a) improving plant capacity (b) improving effluent quality (c) implementing water reuse to counter water scarcity and (d) meeting population growth and tightening permit demands. Designed for both existing and newly proposed plants, the TITAN MEM-BOX™ membrane (read more)
Browse Wastewater Treatment Equipment Datasheets for Smith & Loveless, Inc. -
-resolution greenhouse gas monitoring from space, to manufacture optical sensors for their C12, C13, C14 and C15 satellites set to launch into orbit in 2024. The new satellites will join GHGSat’s expanding constellation which detects and (read more)
Browse Gas Sensors Datasheets for ABB Measurement & Analytics
More Information Top
-
Civil Engineering, Architecture and Sustainable Infrastructure II
C35 concrete .
-
Advances in Civil Structures
1) The quality of unprotected concrete specimens decreased after 300 freeze-thaw cycles and the quality decreasing extent of C50 and C35 concrete specimens is far less than that of C25 concrete specimens in three different erosion environment (Table3 and Table 4).
-
Trends in Building Materials Research
The gradations of C35 concrete are shown in Table 1.
-
Advanced Building Materials and Sustainable Architecture
… is shown in Figure 2, the results shows the numerical specimen compressive strength of 34.5Mpa, the elastic modulus 31.7GPa, Poisson's ratio of 0.2, this result is more consistent with the standard values of C35 concrete cube test as described …
-
Trends in Civil Engineering
C35 concrete f c = 16.7 N / mm 2 , Ac = 0.175m 2 , HRB335 reinforcing steel bar, f y = 310 N / mm .
-
Vibration, Structural Engineering and Measurement I
High-rise building using C35 concrete , mainly is used as compressive material.
-
Structural Foundation Designers' Manual
= 1.20 N/mm2 This is well within the allowable value of 3.75 N/mm2 for grade C35 concrete , given by CP 110: Part 1: Table 21(3) (BS 8110 does not give allowable local bond stresses).
-
Corrosion of reinforcement in concrete (EFC 25)
The C65 concrete with 10% microsilica contains most chlorides, 380 gm-2 surface, while the C35 concrete with 20% microsilica shows the least chloride penetration, 217.8 gm-2 surface.
-
Recent Development on Material Science and Environmental Material
C30 concrete as a test object, through their work performance and experimental study on the strength, determine the appropriate ratio of stone powder sand and washed sand, and then applied to C20, C25, C35 concrete , test concrete workability and mechanical properties respectively …
-
Advances in Civil Engineering and Architecture Innovation
The lattice shell's bar use Q235 steel, modulus of elasticity E=2.06×105Mpa, mass density ρ=7850kg/m3, poisson ratio 0.3; Independent column use C35 concrete , modulus of elasticity E=2.55×105Mpa, mass density ρ=2500kg/m3, poisson ratio 0.2.
Indicates content that may require registration and/or purchase.