Supplier: Accuris
Description: Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-52: Examinations and measurements - Guide hole and alignment pin deformation constant, CD for 8 degree angled PC rectangular ferrule, single mode fibres
-
Supplier: Accuris
Description: Fibre optic interconnecting devices and passive components - Basic test and measurement procedures Part 3-52: Examinations and measurements - Guide hole and alignment pin deformation constant, CD for 8 degree angled PC rectangular ferrule, single mode fibres
-
Supplier: Accuris
Description: Fibre optic interconnecting devices and passive components \x97 Basic test and measurement procedures Part 3-52: Examinations and measurements \x97 Guide hole and alignment pin deformation constant, CD for 8 degree angled PC rectangular ferrule, single mode fibres
-
-
Supplier: Accuris
Description: Fibre optic interconnecting devices and passive components \x96 Basic test and measurement procedures \x96 Part 3-52: Examinations and measurements \x96 Guide hole and alignment pin deformation constant, CD for 8 degree angled PC rectangular ferrule, single mode fibres
-
Description: IEC 61300-3-52:2014 describes a procedure to measure guide hole and alignment pin deformation constant, CD for 8 degree angled PC rectangular ferrule multi-fibre connectors. Keywords: measure guide hole, alignment pin deformation constant, CD, 8 degree angled PC rectangular ferrule
-
Supplier: CSA Group
Description: IEC 61300-3-52:2014 describes a procedure to measure guide hole and alignment pin deformation constant, CD for 8 degree angled PC rectangular ferrule multi-fibre connectors. Keywords: measure guide hole, alignment pin deformation constant, CD, 8 degree angled PC rectangular ferrule
-
Supplier: SAE International
Description: Measuring deformation under dynamic loading is still a key problem in the automobile industry. The first spatial phase-shift shearography system for relative deformation measurement is reported. Traditional temporal phase-shift technique-based shearography systems are capable of
-
Supplier: SAE International
Description: bumper system. Three bumper systems were evaluated. Two QS F-D measurements were performed for each bumper system in order to demonstrate the repeatability of the QS F-D measurement. These measurements had a compression phase and a rebound phase. A series of crash tests were
-
Supplier: ASTM International
Description: 1.1 This test method describes an in situ method for determining the deformation properties of existing unreinforced solid-unit masonry. This test method concerns the measurement of in-situ masonry deformability properties in existing masonry by use of thin, bladder-like flatjack
-
Supplier: AENOR
Description: Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-52: Examinations and measurements - Guide hole and alignment pin deformation constant, CD for 8 degree angled PC rectangular ferrule, single mode fibres
-
Supplier: AENOR
Description: Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-52: Examinations and measurements - Guide hole and alignment pin deformation constant, CD for 8 degree angled PC rectangular ferrule, single mode fibres (Endorsed
-
Supplier: ASTM International
Description: performance of the devices, as insufficient knowledge is available to predict the consequences of the use of any of these devices in individual patients for specific activities of daily living. Furthermore, it is not the intention of this specification to describe or specify specific
-
Supplier: Trilion Quality Systems
Description: ARAMIS is a powerful optical system for measurement of complex materials and structures for their 3D deformation and strain during loading. This tool is a highly robust, full-field, non-contact strain measuring testing device. The system offers a non-contact measurement
-
Supplier: ASTM International
Description: test is designed to allow for the comparative evaluation of intervertebral body fusion devices. 1.4 Guidelines are established for measuring test block deformation and determining the subsidence of intervertebral body fusion devices. 1.5 Units-The values stated in SI units are
-
Supplier: ASTM International
Description: deformation and determining the subsidence of intervertebral body fusion devices. 1.5 Since some intervertebral body fusion devices require the use of additional implants for stabilization, the testing of these types of implants may not be in accordance with the manufacturer's
-
Supplier: tecsis LP
Description: The strain transducer has been designed for applications with the need to measure the deformation due to external forces acting on an existing component. The device is simply screwed onto the component. After calibration the unit obtains the characteristics of a force transducer.
- Accuracy: 2 ±% Full Scale
- Operating Temperature: -4 to 176 F
- Output: Analog Current, Analog Voltage
- Device: Sensor / Transducer
-
Supplier: Certex UK
Description: allows for a QUIC-CHECKTM measurement to determine if the throat opening has changed, thus indicating abuse or overload. To check, use a measuring device to measure the distance between the marks. If the measurement does not meet the dimensions shown below (Deformation
- Maximum Load Capacity: 5.51155655 tons
- Weight: 8.2908 lbs
- Special Applications: Hook
- Features: Other
-
Supplier: Certex UK
Description: allows for a QUIC-CHECKTM measurement to determine if the throat opening has changed, thus indicating abuse or overload. To check, use a measuring device to measure the distance between the marks. If the measurement does not meet the dimensions shown below (Deformation
- Maximum Load Capacity: 16.53466965 tons
- Weight: 39.4695 lbs
- Special Applications: Hook
- Features: Other
-
Supplier: Certex UK
Description: allows for a QUIC-CHECKTM measurement to determine if the throat opening has changed, thus indicating abuse or overload. To check, use a measuring device to measure the distance between the marks. If the measurement does not meet the dimensions shown below (Deformation
- Maximum Load Capacity: 1.7636980960000002 tons
- Weight: 1.43325 lbs
- Special Applications: Hook
- Features: Other
-
Supplier: Certex UK
Description: allows for a QUIC-CHECKTM measurement to determine if the throat opening has changed, thus indicating abuse or overload. To check, use a measuring device to measure the distance between the marks. If the measurement does not meet the dimensions shown below (Deformation
- Maximum Load Capacity: 44.0924524 tons
- Weight: 227.115 lbs
- Special Applications: Hook
- Features: Other
-
Supplier: SAE International
Description: The debate surrounding roof deformation and occupant injury potential has existed in the automotive community for over 30 years. In analysis of real-world rollovers, assessment of roof deformation and occupant compartment space starts with the post-accident roof position. Dynamic
-
Supplier: Trilion Quality Systems
Description: by the CCD camera. Using appropriate image treatment, the difference between the two images shows up with black interference fringes (real time viewing of the actual deformation). Common uses include: - Deflection, strain, thermal expansion and residual stress measurements - FEA
-
Supplier: NETZSCH-Gerätebau GmbH
Description: optional devices for load and deformation measurement and/or constant deformation rate, additional information about the limits of elasticity and crack propagation in ceramic test pieces can be obtained. The modulus of rupture model 422 E/4 is used to test small single
- Test Media: Ceramics / Glass
- Display & Special Features: Computer Interface / Networkable
- Mounting / Loading Options: Laboratory / Batch
- Features: Other
-
Supplier: Haida International Equipment Co., Ltd.
Description: displacement: Encoder (2500P/R), ascending 4 times precision H. Displacement resolution: 0.001mm I. Safety device: Overload emergency stop device, fluctuation travel limit device, leakage automatic broken electricity system, automatic breakpoint stop function Software: The
- Force / Load Capacity: 441 lbs
- Test Speed: 0.003937007874015741 to 19.68503937007871 in/min
- Display / User Interface: Application Software, Computer Interface, Digital Readout / Interface
- Mechanical Test: Tensile
-
Supplier: ASME Standards and Certification
Description: manufacturing. Special emphasis on aerospace, automotive, medical device, precision instrumentation and related industries. Click here for a print-friendly version of this description. Click here for a print-friendly version of a brochure on ASME's B89.7 Measurement Uncertainty
-
Supplier: ASME
Description: manufacturing. Special emphasis on aerospace, automotive, medical device, precision instrumentation and related industries. Click here for a print-friendly version of this description. Click here for a print-friendly version of a brochure on ASME's B89.7 Measurement Uncertainty
-
Supplier: CSA Group
Description: ISO 16790:2005 specifies a method for determining the drawing and break characteristics of molten plastics. The method involves the measurement of the force generated in deforming a molten filament under defined extrusion temperature and drawing conditions. Data is generated under
-
Description: ISO 16790:2005 specifies a method for determining the drawing and break characteristics of molten plastics. The method involves the measurement of the force generated in deforming a molten filament under defined extrusion temperature and drawing conditions. Data is generated under
-
Supplier: SAE International
Description: device to determine the firing time of deployment. However, it is generally not easy to measure soil deformation behavior and interaction force with the vehicle at every instant. In contrast, numerical simulation can be an effective way to obtain time history data of soil
-
Supplier: Epsilon Technology Corp.
Description: lateral deformation of specimens. They are self-supporting on the sample and clip on in seconds. The traditional way this deformation has been measured was prone to errors caused by slight rocking of the sample as it is loaded. The self-supporting design of the Model 3911 eliminates
- Test Temperature: -40 to 212 F
- Test Standard: ASTM
- Test Fixture Type: Extensometer
- Application: Tensile
-
Supplier: Security Engineered Machinery Co., Inc.
Description: email. Maintenance Program Statement of Work Check access door for proper operation. Check rotate gate to ensure it is securely in place and rotates smoothly. Check slide assembly for proper operation. Clean foreign matter and/or dirt from slide assembly and device tray. Check rotation of
-
Supplier: DigiPas Technologies Inc.
Description: VibroMeter display real time vibration graph AngularMeter display real-time angle graph Basic PC Sync software USB connection (5 Meters) to device for remote data display Professional PC Sync Software USB connection to device for remote data logging (Optional) Wireless Bluetooth Low
- Angular Range: 0 to 20 degrees
- Angular Resolution: 0.001 degrees
- Measuring Technology: Electronic
-
Supplier: DigiPas Technologies Inc.
Description: Specification Measuring range: 0.000° ~ ±2.000° dual-axis Resolution: 0.0002”/ft or 5-second (0.020 mm/M or 0.001°) Accuracy: ±0.0004”/ft or 10-second (± 0.002°) from 0° to ±0.5° ± 0.004° at other angles User may use device without or with Bluetooth® Measurement when paired with
- Angular Range: 0 to 2 degrees
- Measuring Technology: Electronic
-
Supplier: DigiPas Technologies Inc.
Description: Specification Measuring range: 1.0” or 0.00° ~ ±5.00° dual-axis Resolution: 0.002”/ft or 40-second (0.18 mm/M or 0.01°) Accuracy: ±0.004”/ft or 80-second (± 0.02°) from 0° to ±0.5° and 0.04° at other angles User may use device without or with Bluetooth® Measurement when paired with
- Angular Range: 5 degrees
- Measuring Technology: Electronic
-
Supplier: DigiPas Technologies Inc.
Description: Specification Measuring range: 90.000° ~ ±5.000° dual-axis Measurement Resolution Table: Vertical Stroke Length (mm) Resolution 50 1µm / 50mm 100 2µm / 100mm 150 3µm / 150mm 300 5µm / 300mm 400 7µm / 400mm 500 9µm / 500mm 800 14µm / 800mm 1,000 17µm / 1,000mm Measurement Accuracy:
- Angular Range: 90 to 5 degrees
- Measuring Technology: Electronic
Find Suppliers by Category Top
Featured Products Top
-
information about the device under test (DUT); the test sequence and test parameters can be varied automatically from DUT to DUT based on this information Takes advantage of the high-speed computing technology of modern PCs to take measurements and perform test analyses in parallel, thereby (read more)
Browse Test, Inspection, and Measurement Software Datasheets for Radiant Vision Systems -
Widely used for measuring deformations in three- and four-point bend tests, compression tests and a variety of general-purpose deflection measurements. These strain gaged devices come with a magnetic base for easy mounting. Deflection is measured with a single arm with an attached (read more)
Browse Deflectometers and Extensometers Datasheets for Epsilon Technology Corp. -
systems; devices for control of movement and distance, digital cameras for machine vision, measurement instruments for railway transport; video processing FPGA IP-cores and hardware; machine vision systems. RIFTEK products are delivered in more than 70 countries. Company representative (read more)
Browse Dimensional Gages and Instruments Datasheets for RIFTEK EUROPE Sp. z.o.o. -
, sometimes with a disposable for the separation of the pressure sensor from the media. Further requirement could be, that cleaning and sterilization should be avoided, no medium should leak out and the hose should be easy to replace. One field of such an application are medical devices, e (read more)
Browse Pressure Sensors Datasheets for Endress + Hauser – Sensors & Components -
drifted. However, traditional measurement techniques like Coordinate Measuring Machines (CMM) do not fit well for the task – the process is slow and tubes are tricky for alignment and for measurement via touchprobing. Characteristics of formed tubes such as deformation, elongation and (read more)
Browse Dimensional Gages and Instruments Datasheets for Accurex Measurement, Inc. -
; 2D and 3D laser scanners; optical micrometers; absolute linear encoders; data acquisition, processing and indication systems; control systems; devices for control of movement and distance, digital cameras for machine vision, measurement instruments for railway transport; video processing FPGA IP (read more)
Browse Dimensional and Profile Scanners Datasheets for RIFTEK EUROPE Sp. z.o.o. -
using devices of proven metrological quality, and then post-processed in an intuitive and user-friendly software ecosystem. In the wake of these numerous improvements, POLYAÉRO® Center of Excellence thus found itself in need of reliable means for digitizing parts and models that (read more)
Browse 3D Scanners Datasheets for FARO CREAFORM
Conduct Research Top
-
Surface Acoustic Wave (SAW) Torque Measurement - How it Works...
The measurement technology for our 'TorqSense ' RWT410/420, RWT430/440 and RWT450/460 Series Torque Transducers and torque meters is based on the patented technology of measuring the resonant frequency change of 'Surface Acoustic Wave ' (SAW) devices in a non-contact manner when strain is applied
More Information Top
-
SIMPLE PERFORMANCE TESTER FOR SUPERPAVE MIX DESIGN: FIRST-ARTICLE DEVELOPMENT AND EVALUATION
Given that the flow time and flow number are determined from the derivative of the strain history, the Project 9-29 research team suggested that an actuator-mounted deforma- tion measuring device could be used to detect flow in these tests.
-
EVALUATION OF INDIRECT TENSILE TEST (IDT) PROCEDURES FOR LOW-TEMPERATURE PERFORMANCE OF HOT MIX ASPHALT
In many cases, the changes are slight, such as rounding the maximum load to 100 kN rather than 98 kN, or the recom- mended 0.1 µm sensitivity for the deformation measuring devices compared with the original 0.125 µm sensitivity.
-
Implementation of Startup Procedures in the Laboratory
Deformation measurement device 2.
-
An effect on walk and plantar contact area from ice immersion approach
A plantar skin deformation is measured by a “plantar skin deformation measurement device ” (Fig.1).
-
Springer Handbook of Experimental Solid Mechanics
Deformation Measuring device .