Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Description: This guide has been prepared to aid in the application of relays and relaying schemes for the protection of synchronous generators for single-phase-to- ground faults in the stator winding. The guide is not intended for the selection of generator or ground connection
-
Supplier: Mersen
Description: ground faults and line faults using Mersen's HelioProtection fuse line. Features Low fault current interrupting capability Durable construction for enhanced system longevity Temperature cycle withstand capability Guaranteed operation at temperature
- Approvals / Standards: UL Approval, CSA Certification, IEC (UMF) Approval
- Current Rating: 30 amps
- Material: Other
- Mounting: Other
-
Supplier: Mersen
Description: minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line
- Approvals / Standards: UL Approval, CSA Certification, IEC (UMF) Approval
- Current Rating: 30 amps
- Material: Other
- Mounting: Other
-
-
Supplier: Mersen
Description: 6J designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground
- Approvals / Standards: UL Approval, CSA Certification
- Current Rating: 600 amps
- Material: Other
- Mounting: Other
-
Supplier: Mersen
Description: J designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground
- Approvals / Standards: UL Approval, CSA Certification
- Current Rating: 600 amps
- Features: Indicating
- Material: Other
-
Supplier: Waytek, Inc.
Description: self-locking hardware and optional weather-proof labels in standard options Supports SAE Circuit Protection Standards Included ground block section can separated from fuse block section affording increased deployment options for challenging installations Use with ATO
- Current Rating: 30 amps
- Features: Indicating
- Voltage Rating: 24 volts
-
Supplier: Waytek, Inc.
Description: self-locking hardware and optional weather-proof labels in standard options Supports SAE Circuit Protection Standards Included ground block section can separates from Fuse Block section affording increased deployment options for challenging installations Use with ATO
- Current Rating: 30 amps
- Features: Indicating
- Voltage Rating: 24 volts
-
Supplier: ASAP Semiconductor LLC
Description: POLYSWITCH 2.6A RESET FUSE SMD 2.6A 8A 40A 6V 0.025 ~ 0.075 Ohm 20s 2-SMD Digi-Reel«
- Device Type: Ground Fault Circuit Interrupters (GFCI), Resettable PTC
-
Supplier: ASAP Semiconductor LLC
Description: POLYSWITCH 3.00A RESET FUSE SMD 3A 8A 40A 6V 0.015 ~ 0.048 Ohm 35s 2-SMD Digi-Reel«
- Device Type: Ground Fault Circuit Interrupters (GFCI), Resettable PTC
-
Supplier: ASAP Semiconductor LLC
Description: POLYSWITCH 2.6A RESET FUSE SMD 2.6A 8A 40A 6V 0.025 ~ 0.075 Ohm 20s 2-SMD Cut Tape (CT)
- Device Type: Ground Fault Circuit Interrupters (GFCI), Resettable PTC
-
Supplier: Waytek, Inc.
Description: self-locking hardware and optional weather-proof labels in standard options Supports SAE Circuit Protection Standards Ground Block included - Ground Block section can separate from Fuse Block section, increasing deployment options for challenging installations Use with
- Current Rating: 30 amps
- Features: Indicating
- Voltage Rating: 24 volts
-
Supplier: ValueTronics International, Inc.
Description: mA Test on earth leakage relay RCDs (with RCDX10 optional accessory) Line/fault impedance with prospective short circuit current calculation High resolution line/fault impedance (with IMP57 optional accessory) Curve B, C, D, and K MCBs and type gG and aM fuses
- Types of Measurements: Insulation Resistance, Current Leakage Tester, Ground Bond Testers
-
Supplier: RS Components, Ltd.
Description: Professional range of Cooper Bussmann time delay fuses from the FRN-R series. The fuses are designed to provide motor overload, ground fault and short-circuit protection Mounting Style - Holder. Termination Style - Clip. Various current ratings available Current
- Current Rating: 2 amps
-
Supplier: RS Components, Ltd.
Description: Professional range of Cooper Bussmann time delay fuses from the FRN-R series. The fuses are designed to provide motor overload, ground fault and short-circuit protection Mounting Style - Holder. Termination Style - Clip. Various current ratings available Current
- Current Rating: 5 amps
-
Supplier: RS Components, Ltd.
Description: Professional range of Cooper Bussmann time delay fuses from the FRS-R series. The fuses are designed to provide motor overload, ground fault and short-circuit protection Mounting Style - Holder. Termination Style - Clip. Various current ratings available Current
- Current Rating: 15 amps
-
Supplier: RS Components, Ltd.
Description: Professional range of Cooper Bussmann time delay fuses from the FRS-R series. The fuses are designed to provide motor overload, ground fault and short-circuit protection Mounting Style - Holder. Termination Style - Clip. Various current ratings available Current
- Current Rating: 2 amps
-
Supplier: CableOrganizer.com, Inc.
Description: either a time-delay or a fast-acting fuse is needed, which makes selection easier and certainly cuts down on the spare fuse inventory you have to stock creating a substantial cost reduction. These fuses are intended to provide short circuit and ground fault
-
Supplier: CableOrganizer.com, Inc.
Description: What's special about these fuses? Provides motor overload, ground fault and short-circuit protection so that your devices are protected from potentially irreparable damage Sturdy units will hold an overload up to five times greater than its ampere rating for a minimum
-
Supplier: Quail Electronics
Description: devices & appliances which use the IEC-60320-C14 inlet. These power cords feature a ground wire. We incorporated a Ground Lead on this C13 to add an extra layer of fault protection. In the event of an electrical short in your equipment, the Ground Lead will
- Compliances and Approvals: RoHS Compliant, PSB
- Cord Length: 98.43 inch
- Male End Type: BS 1363 (UK), EN 60320-C14
- Number of Conductors: 3 Conductors
-
Supplier: Radwell International
Description: CIRCUIT BREAKER,3 POLE,30AMP,30MA,NO- FUSE,W/GROUND FAULT PROTECTION, 100-240VAC. FREE 2 YEAR RADWELL WARRANTY
- Number of Poles: 3
-
Supplier: Radwell International
Description: CIRCUIT BREAKER, TYPE HPC, TYPE THPR, HIGH PRESSURE, CONTACT FUSIBLE SWITCH, 3 POLE, 3 PHASE, 800 AMP, 600V, 200KA @ 480V, HIGH INTERRUPTING CAPACITY, BUILT-IN GROUND FAULT PROTECTION, BOTTOM-FEED. FREE 2 YEAR RADWELL WARRANTY
- Continuous Current Rating: 800 amps
- Number of Poles: 3
-
Supplier: Radwell International
Description: EARTH LEAKAGE CIRCUIT BREAKER, GROUND FAULT PROTECTION, FRAME SIZE: 50, 3 POLE, 100-240 VAC, 50 AMP 30 MILLIAMPS, NO-FUSE CIRCUIT BREAKER, INTERRUPTING RATING 14 KILLOAMPS, UL 489. FREE 2 YEAR RADWELL WARRANTY
- Continuous Current Rating: 50 amps
- Number of Poles: 3
- Rated AC Voltage: 240 volts
-
Supplier: Radwell International
Description: DISCONTINUED BY MANUFACTURER, NO -FUSE BREAKER, WITH GROUND FAULT PROTECTION, 150A, 3 POLE, A 100-300-500MA, 50/60HZ, 240VAC 35KA. FREE 2 YEAR RADWELL WARRANTY
- Number of Poles: 3
-
Supplier: UL Standards & Engagement
Description: for ground-fault protection when combined with ground-fault sensing and relaying equipment as follows: a) Switches for use with Class I ground-fault sensing and relaying equipment include those that are capable of interrupting 12 times their rated current or that have
-
Supplier: CSA Group
Description: acceptability for ground-fault protection when combined with ground-fault sensing and relaying equipment as follows: a) Switches for use with Class I ground-fault sensing and relaying equipment include those that are capable of interrupting 12 times their rated current or
-
Supplier: Eaton Cooper Power Systems
Description: Protected transformers are available with a variety of protection options including a MagneX Interrupter, a secondary breaker with weak link for secondary fault and overload protection, a primary weak link fuse, current-limiting fusing for high interrupting ratings
- Maximum Primary Voltage Rating: 2400 to 19920 volts
- Maximum Secondary Voltage Rating: 120 to 600 volts
- Mounting / Form Factor: Pole-Mounted
- Output Voltage: AC
-
Supplier: Microchip Technology, Inc.
Description: fault detection Supports 85 Vrms internal ringing 3.3 V and battery supplies Dual battery operation for system power saving Automatic battery switching Intelligent thermal management Compatible with inexpensive protection
- IC Package Type: Other
-
Supplier: Haida International Equipment Co., Ltd.
Description: temperature: =30? Compressed air: 0.5~0.7MPa Standard configuration: Light of chamber’s condition, timer 1pc, fairlead (25x100mm) 1pc, trundle 4pcs, Levelers4pcs Safety device: ground fault circuit interrupters, the chambers temperature is too high
- Configuration: Floor Mount
- Features: Programmable
- Temperature Control: Heating, Cooling
- Temperature Range: -65 to 175 C
-
Supplier: Tripp Lite by Eaton
Description: types and selectable line to battery power transfer voltages. Includes AC input surge suppression. Includes hospital grade plug and outlets with GFI (ground fault interrupter) protection. TUV tested to UL458 (mobile inverter) and CAN/CSA-C22.2 No. 107.1-01. Meets GSA ambulance
- AC Input Current: 32 amps
- AC Input Voltage: 120 volts
- AC Output Voltage: 120 volts
- DC Input Current: 127 amps
-
Supplier: Tripp Lite by Eaton
Description: with utility- or generator-supplied AC electricity filtered through premium ISOBAR surge protection. It's the ideal, quiet alternative to gas generators -- with no fumes, fuel or noise to deal with! The MRV2012UL Inverter/Charger supplies up to 2000 watts of continuous 120V AC power from any
- AC Input Current: 38 amps
- AC Input Voltage: 120 volts
- DC Input Current: 190 amps
- DC Input Voltage: 12 volts
-
Supplier: Bourns, Inc.
Description: The Bourns Technology Center is home to several emerging high-tech companies in Riverside, California. It is dedicated to providing a strong partnership between resident companies and the community. The Bourns Technology Center is located at the entrance to one of the fastest developing industrial
- Current Rating: 7 amps
- Fuse Type: Protective
- Mounting: Solderable (surface mount)
- RoHS Compliant: Yes
-
Supplier: Altech Corp.
Description: British fuses are typically used for industrial and general applications to protect cable and motor circuits. They are available with four different mounting plates.
- Approvals / Standards: BSI Approval, IEC (UMF) Approval
- Current Rating: 16 amps
- Fuse Type: Protective
- Mounting: Replaceable (with holder or clips)
-
Supplier: SOC America, Inc.
Description: SOC Fuse Technology Over its fifty-two years of existence, SOC has spent considerable research efforts to ensure the safety of its customers, and has worked with Mitsubishi Motors for fifteen of those years on the development of highly reliable fuses for electric vehicles. The
- Current Rating: 10 amps
- Fuse Type: Protective
- Material: Ceramic
- Mounting: Solderable (surface mount)
-
Supplier: Opto 22
Description: The SNAP-FUSE4AB is a pack of 25 4-amp fuses for use with SNAP racks and power supplies.
- Current Rating: 4 amps
- Fuse Type: Protective
- Material: Glass
- Mounting: Replaceable (with holder or clips)
-
Supplier: Block USA, Inc.
Description: Input rated voltage 24 Vdc Output rated voltage 24 Vdc Output rated current 4 x 8 A Ambient temperature -10° C to +60° C Efficiency typ. 96 % Protection index IP 20 Electronic circuit breaker to UL 60950, UL
- Approvals / Standards: UL Approval
- Current Rating: 8 amps
- Fuse Type: Protective
- Mounting: Other
Find Suppliers by Category Top
Featured Products Top
-
What is the HF note? As the NEC now requires Ground Fault protection for a larger scope of applications & higher rated circuits in the recent Code cycles, high frequency during start up (read more)
Browse Ground Fault Circuit Interrupters (GFCI) Datasheets for Tecmark Corporation -
Special Purpose Ground Fault Circuit Interrupter (SPGFCI) Product (read more)
Browse Ground Fault Circuit Interrupters (GFCI) Datasheets for Tecmark Corporation -
2026 Code Year: NEC 680 Lets dive into the Ground Fault Protection requirements of the Leisure Water industry. Read about what NEC 680 mandates for pools, spas, fountains, and more (read more)
Browse Ground Fault Circuit Interrupters (GFCI) Datasheets for Tecmark Corporation -
Altech PV protection components are built to help safeguard key parts of a solar power system, from the DC string side through the inverter and out to the grid connection. gPV fuses are designed to protect cables and PV modules against reverse overcurrent, helping (read more)
Browse Fuses Datasheets for Altech Corp. -
The Vicfuse VD Series is a high-performance semiconductor protection fuse designed for advanced DC circuit protection in power electronic systems. It is engineered to safeguard sensitive semiconductor devices such as diodes, thyristors, GTOs, and IGBTs from (read more)
Browse Circuit Protection Components Datasheets for VICFUSE -
The Vicfuse UL Class Fuse Series is a comprehensive industrial protection portfolio designed to support a wide range of AC and DC electrical systems. The series is organized into multiple UL fuse classes, each optimized for specific operating requirements (read more)
Browse Circuit Protection Components Datasheets for VICFUSE -
semiconductor devices are highly sensitive to short-circuit faults. Even a brief overcurrent event can cause irreversible damage. VRA semiconductor protection fuses provide ultra-fast, high-capacity protection, allowing engineers to precisely coordinate protection schemes while ensuring system safety, reliability, and compact design integration. (read more)
Browse Fuses Datasheets for VICFUSE -
, the VSP-000 fuse combines high fault protection with low I²t energy let-through. This helps prevent damage to downstream semiconductor devices and enhances system reliability. Key Features (read more)
Browse Circuit Protection Components Datasheets for VICFUSE -
OEM electrical systems Industrial Benefits The VCTMP fuse is engineered to provide dependable protection for motor-driven systems where temporary startup currents are common. Its time-delay design helps improve system uptime by reducing unnecessary fuse replacement, while its current-limiting characteristics help protect equipment from damaging fault currents. (read more)
Browse Fuses Datasheets for VICFUSE -
end equipment comes a greater need for protection. E-Fuse, enabled by Microchip's 700V and 1200V Silicon Carbide (SiC) technology, provides a faster, more reliable method for protecting power electronic applications. E-Fuse solutions can detect and interrupt fault currents microseconds (read more)
Browse Power MOSFET Datasheets for Richardson RFPD
Conduct Research Top
-
Fake Products, Real Dangers
that commonly counterfeited electrical products include extension cords, fuses, circuit breakers, surge protectors and ground fault circuit interrupters. So what does any of this have to do with the plastics industry? Plenty. Plastics manufacturers, processors and compounders such as Plastics Color Corporation
More Information Top
-
Selecting overcurrent protection for three-phase transformers
This makes it more difficult to provide overload capability and ground fault protection with fusing from the primary side of a delta-grounded-wye transformer.
-
In-situ permeability measurements with direct push techniques: Phase II topical report
The instrument package houses all power supplies, a/d (analog to digital) modules, ground fault protection , fuses , power switches, and outlets.
-
Development and Application of Fault-Withstand Standards for Power Transformers
Fuse Protection - Ground Faults .
-
Best Practices for Commercial Roof-Mounted Photovoltaic System Installation
The specific wiring failure that occurred in both the Bakersfield and Mount Holly fires was that one of the conductors faulted but did not blow the protective ground - fault fuse .
-
Electricity and the Working Diver
If the electrical system is powered via standard circuit breakers and fuses without ground fault protection the fault current is limited only by the circuit breaker or fuse rating.
Indicates content that may require registration and/or purchase.