Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Accuris
Description: Standard Method of Test for Apparent Viscosity of Hot-Poured Bituminous Crack Sealant Using Brookfield Rotational Viscometer RV Series Instrument
-
Supplier: Haida International Equipment Co., Ltd.
Description: Mooney viscometer Applications: Mooney viscometer is used for testing reclaimed rubber or gross rubber viscosity, etc. Computer control, data display, automatic calibration. Mooney viscometer is a precision laboratory test instrument of rubber industries. The
-
Supplier: CANNON Instrument Company
Description: For Dilute Solution Viscosity of Polymers in Organic Solvents and Aqueous Solutions to 135 °C PolyVISC® is a fully automated, benchtop capillary viscometer with an 11 position sample handler for unattended processing and testing of of dilute solution viscosity of polymers in
- Kinematic Viscosity Range: 0.3 to 20,000 cSt
- Display & Special Features: Computer Interface / Networkable, Laboratory / Benchtop (Batch)
- Features: Specialty / Other
-
-
Supplier: CANNON Instrument Company
Description: For Dilute Solution Viscosity of Polymers in Organic Solvents and Aqueous Solutions miniPV® is a fully-automated, single sample, benchtop viscometer for testing dilute solution viscosity of polymers in organic solvents and aqueous solutions. The Ubbelohde-style tube covers a
- Kinematic Viscosity Range: 0.3 to 5,000 cSt
- Accuracy: 0.01 ±% Full Scale
- Display & Special Features: Computer Interface / Networkable, Laboratory / Benchtop (Batch)
- Features: Specialty / Other
-
Supplier: CSC Scientific Company, Inc.
Description: The First Pro Viscometer was built for those who want the capabilities of the DV2 Viscometer and the range, sturdiness, and reliability of Lamy instruments. A step between the First Plus and the RM 100 Plus, the First Pro Viscometer offers the measuring range and spindle
- Display & Special Features: Computer Interface / Networkable, Laboratory / Benchtop (Batch)
- Technology / Test Method: Vibratory / Oscillating Viscometry
-
Supplier: CSC Scientific Company, Inc.
Description: Viscosity measurement range: 1 - 540,000,000 mPa·s More spindle options are compatible Save test parameters and data directly on the instrument Able to connect to temperature control accessories Optional UD readings with MS-R spindles
- Display & Special Features: Computer Interface / Networkable
-
Supplier: CANNON Instrument Company
Description: The compact, economical TESC-5133 Low Temperature Viscometer integrates and automates the ASTM D5133 process of conditioning and testing low temperature viscosities of engine lubricants. The TESC 5133 Windows® 10 software application records sample temperature and viscosity throughout
- Industry / Application: Automotive
- Display & Special Features: Graphic / Video Display, Laboratory / Benchtop (Batch), Measures Temperature
- Features: Specialty / Other
-
Supplier: Gilson Company, Inc.
Description: These viscometers measure kinematic viscosity of bitumens and road oils at 140°F (60°C) and asphalt cements at 275°F (135°C). Precision is ±0.2%. Using only a 1-3ml charge, the viscometer can be filled and cleaned while immersed in a constant temperature bath. Instrument
-
Supplier: Anton Paar
Description: between -60 °C and +135 °C. A single measuring cycle on a small sample volume yields kinematic viscosity, density, dynamic viscosity, Viscosity Index and more. SVM™ 4001 is a double-cell instrument especially tailored for simultaneous measurements of viscosity and
- Dynamic Viscosity Range: 0.2 to 30,000 cps
- Industry / Application: Aerospace, Automotive, Diesel / HFO Blending, Fuel Testing, Petroleum / Oil & Gas
- Display & Special Features: Computer Interface / Networkable, Laboratory / Benchtop (Batch), Measures Temperature
-
Supplier: Gilson Company, Inc.
Description: These viscometers measure kinematic viscosity of bitumens and road oils at 140°F (60°C) and asphalt cements at 275°F (135°C). Precision is ±0.2%. Using only a 1-3ml charge, the viscometer can be filled and cleaned while immersed in a constant temperature bath. Instrument
-
Supplier: Gilson Company, Inc.
Description: These viscometers measure kinematic viscosity of bitumens and road oils at 140°F (60°C) and asphalt cements at 275°F (135°C). Precision is ±0.2%. Using only a 1-3ml charge, the viscometer can be filled and cleaned while immersed in a constant temperature bath. Instrument
-
Supplier: Gilson Company, Inc.
Description: These viscometers measure kinematic viscosity of bitumens and road oils at 140°F (60°C) and asphalt cements at 275°F (135°C). Precision is ±0.2%. Using only a 1-3ml charge, the viscometer can be filled and cleaned while immersed in a constant temperature bath. Instrument
-
Supplier: ASTM International
Description: 1.1 This test method covers the procedure for determining the viscosity of varnishes, ink vehicles, and similar liquids that are essentially nonvolatile and unreactive under ordinary room conditions using the Duke Automated high shear rod and collar viscometer. 1.2 The
-
Supplier: AMETEK Brookfield
Description: Brookfield offers a completely digital calculating Krebs Unit Instrument with all the reliability you'd expect in Brookfield instrumentation...now with relative centipoise display. Why the KU-3? This instrument is used widely for making viscosity measurements on paints/coatings
- Dynamic Viscosity Range: 27 to 5,274 cps
- Accuracy: 1 ±% Full Scale
- Industry / Application: Adhesives, Coatings / Paints
- Display & Special Features: Computer Interface / Networkable, Laboratory / Benchtop (Batch), SPC / Application Software
-
Supplier: CANNON Instrument Company
Description: For Kinematic Viscosity of Transparent and Opaque Liquids CAV®-2100 is a single-bath laboratory viscometer with a 13 position sample handler for unattended D445 processing. Each of the two Atlantic-style tubes covers a 100-fold viscosity range between 0.5 cSt and 10,000 cSt from
- Kinematic Viscosity Range: 0.5 to 6,000 cSt
- Display & Special Features: Computer Interface / Networkable, Laboratory / Benchtop (Batch)
- Industry / Application: High Pressure / Hydraulic Fluids, Marine, Petroleum / Oil & Gas
- Features: Specialty / Other
-
Supplier: AMETEK Brookfield
Description: The STT-100® In-Line Viscometer is designed to provide years of trouble-free service in closed loop systems which require constant monitoring and associated control of product viscosity. This instrument is 3A approved and has been used successfully in many food applications.
- Dynamic Viscosity Range: 350 to 250,000 cps
- Industry / Application: Cosmetics, Food and Beverage
- Display & Special Features: In-Line / In-Tank (Process / Continuous)
- Technology / Test Method: Rotational Viscometry (Spindle)
-
Supplier: AMETEK Brookfield
Description: Brookfield offers a completely digital calculating Krebs Unit Instrument with all the reliability you'd expect in Brookfield instrumentation...now with relative centipoises display. Features And Benefits Continuous sensing and display in Krebs units, grams, and centipoise Allows rapid sample
- Dynamic Viscosity Range: 40 to 141 cps
- Accuracy: 1 ±% Full Scale
- Industry / Application: Adhesives, Chemical Processing, Coatings / Paints, Cosmetics, Food and Beverage, Non-Newtonian Liquid, Petroleum / Oil & Gas, Pharmaceutical, Pulp and Paper
- Display & Special Features: Computer Interface / Networkable, Laboratory / Benchtop (Batch), Temperature Compensated
-
Supplier: AMETEK Brookfield
Description: characters that are easy to view, both close up and at distance The bubble level has been conveniently situated on the front of the instrument below the display panel so that users can easily adjust the instrument for true vertical position Shows test control parameters (spindle,
- Dynamic Viscosity Range: 1 to 104,000,000 cps
- Display & Special Features: Graphic / Video Display, Laboratory / Benchtop (Batch)
-
Supplier: Haida International Equipment Co., Ltd.
Description: Specifications 1. High quality, high accuracy 2. Reasonable price 3. Great after-sale service Rotational Viscometer This instrument is suitable to test liquid viscosity resistance and the absolute viscosity of liquids. It is widely used to measure the viscosity of
- Dynamic Viscosity Range: 10 to 100,000 cps
- Display & Special Features: Laboratory / Benchtop (Batch)
-
Supplier: ASTM International
Description: 1.1 This test method covers the procedure for determining the viscosity of varnishes, ink vehicles, and similar liquids that are essentially nonvolatile and unreactive under ordinary room conditions using the Duke Automated high-shear rod and collar viscometer.2 1.2 The
-
Supplier: ASTM International
Description: 1.1 This test method covers the laboratory determination of the viscosity of oils at 150oC and 1 X 106s-1 and at 100oC and 1 X 10 6s-1, using high shear rate tapered-plug viscometer models BE/C or BS/C. 1.2 Newtonian calibration oils are used to adjust the working gap and for
-
Supplier: Anton Paar
Description: L-Vis 510 is an inline viscometer which is immersed directly in the production liquid. It continuously displays the viscosity and temperature of lubricants, starch adhesives, suspensions, and many more process liquids, allowing 24-hour production monitoring. L-Vis 510 is available in
- Dynamic Viscosity Range: 1 to 50 cps
- Industry / Application: Chemical Processing, Cosmetics, Food and Beverage, Petroleum / Oil & Gas, Pharmaceutical
- Display & Special Features: Computer Interface / Networkable, Graphic / Video Display, Laboratory / Benchtop (Batch), Measures Temperature, SPC / Application Software
-
Supplier: Cole-Parmer
Description: allows hassle-free testing These lightweight digital viscometers can be operated handheld or on a stand (order separately) for your convenience. Converting the handheld to use on a stand is only a matter of seconds - simply place in the special instrument holder. Use for quick
- Dynamic Viscosity Range: 1.5 to 330 cps
- Accuracy: 5 ±% Full Scale
- Technology / Test Method: Rotational Viscometry (Spindle)
-
Supplier: Cole-Parmer
Description: allows hassle-free testing These lightweight digital viscometers can be operated handheld or on a stand (order separately) for your convenience. Converting the handheld to use on a stand is only a matter of seconds - simply place in the special instrument holder. Use for quick
- Dynamic Viscosity Range: 30 to 400,000 cps
- Accuracy: 5 ±% Full Scale
- Technology / Test Method: Rotational Viscometry (Spindle)
Find Suppliers by Category Top
Featured Products Top
-
. Principle of Operation MiniVisc 3000 viscometers use a patented split cell design that enables measurement of kinematic viscosity using only a few drops (60µL) of oil. When closed, the center pieces of the split cell form a funnel with 100 micron gap allowing oil (read more)
Browse Viscometers Datasheets for AMETEK Spectro Scientific -
There are several ways to monitor viscosity including Kinematic Viscometers (u-tubes) per ASTM D445, Ametek Spectro Scientific’s MiniVisc 3000 per ASTM D8092, Visgages, Rheometers and Rotational (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
. Viscosity — ASTM D8092 Viscosity is measured using a temperature-controlled kinematic viscometer with a patented split-cell design. A funnel, with a 100 micron gap, is formed in the center of the cell. Optical sensors in the cell detect the flow (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific
Conduct Research Top
-
Calculation of Viscometer Constants for Cannon-Fenske Routine and Cannon-Fenske Opaque Viscometer
filling is normally done at ambient temperature and the kinematic. viscosity is most often measured at another temperature, the volume of the test sample in. these viscometers increases or decreases slightly as the temperature rises or falls. This. volume change causes a change in the driving head
-
Viscosity Measurment Application Notes
Most laboratory viscometers employ the well-known principle of rotational viscometers to measure viscosity by sensing the torque required to rotate a spindle at a constant speed while it is immersed in the sample fluid. This is because the torque, generally measured using the reaction torque
-
Precision of Viscosity Measurements
The basic measurement unit of viscosity is centipoise. Most methods of measuring viscosity depend on a direct relationship to centipoise units for their validity. In the case of most processes requiring control of viscosity, the "cup second" method of measurement is used to calibrate automatic
-
Analysis of Errors in Viscosity Measurement
An analysis was conducted to compare the operational characteristics of two different bench-. top semi-automated viscometers - the Cannon SImpleVIS and the Spectro Q3000. This analysis. looked at three key areas which can lead to errant viscosity measurements when utilizing a. capillary viscometer
-
Ask the Expert: Measuring the Viscosity of an Oil
using kinematic viscometers and reported in centistokes (cSt). Viscosity can also be measured using absolute (dynamic) viscosity techniques and reported in centipoise. Absolute techniques typically use rotational viscometers, whereas kinematic techniques will commonly use flow viscometers dependent
-
SPECTROVISC Q3000 SERIES VISCOMETER - A PORTABLE KINEMATIC OIL ANALYSIS SOLUTION FOR FIELD-BASED USERS
This paper describes how using the handheld, solvent-free SpectroVisc Q3000 Series device in the field provides immediate and accurate kinematic viscosity measurements, even when compared to traditional laboratory viscometers. The SpectroVisc Q3000 Series uses new solvent-free technology
-
Viscosity Standards: Mixing For The Right Blend
before shipment to the customer, but also at times in process to make sure that the evolution of the mixture is progressing correctly. The popular workhorse in most QC labs is the rotational viscometer. (See Figure 1) This instrument can measure a broad viscosity range, depending on choice
-
Eliminate Degassing When Measuring Viscosity of Compressor Oils
Compressor oils can create unique challenges when trying to measure viscosity. Dissolved gases from refrigerants, in particular, tend to bubble out when these oils are measured using traditional viscometers. This can create errors in the measurement, typically causing readings to be much lower than
More Information Top
-
Increasing the service life of medium-speed marine and locomotive diesels
Because of this situation, the values obtained for used-oil viscosity (Table 2) with optimal loads in the Rheo/ Hoeppler viscometer ( instrument for determining viscosities :of opaque and structurized substances) are found to de- viate sharply from those obtained in a capillary …
-
RSMeans Illustrated Construction Dictionary, Student Edition
A screw stair. viscometer Instrument for determining viscosity of slurries, mortars, or concretes. viscosity The degree to which a fluid resists flow under an applied force. viscous filter An air-cleaning filter that employs a surface covered with viscous oil or fluid …
-
Food Analysis
… thinning Torque A force generating rotation about an axis, which is the product of the force and the perpen- dicular distance to the rotation axis Torsion A twisting force applied to a specimen Viscometer An instrument measuring viscosity Viscosity An internal resistance …
-
Encyclopedic Dictionary of Polymers
Viscometers n Instruments for measuring viscosity including mechanical probe and torque types as the Brookfield Viscometer, capillary tube types as the Cannon-Fenske or Ostwald-Fenske, and flow through orifice types as the Ford Cup.
-
Injection Technologies for the Repair of Damaged Concrete Structures
Depending on the measurement instrument ( viscometer ) type, the viscosity value (η) for the fluent polymer compositions is representable in time units (minutes or seconds).
-
The Wiley Encyclopedia of Packaging Technology 3rd Edition Complete Document
Viscometer An instrument to measure viscosity .
-
Industrial and Specialty Papers, Volume 2, Manufacture
If possible, the viscosity should be evaluated by means of a rotational type viscometer or other instrument and viscosity plotted against the rate of shear.
-
Development and Application of the PRL Single-Pass Capillary Viscometer
Use of capillary instruments as relative viscometers for viscosity -shear measure- ments not only shows excellent agree- ment with rotational viscometers but also retains the advantages cited (4).
Indicates content that may require registration and/or purchase.