Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Total Lubricants USA, Inc.
Description: Mineral oil based, type I electrical insulating oil. Recommended for use in electrical equipment such as distribution, substation transformers, circuit breakers, oil filled capacitors, switches, tap changers, and electrical reclosures.
- Applications: Electrical / Electronic
- Chemistry / Constituents: Petroleum / Mineral Oil
-
Supplier: Total Lubricants USA, Inc.
Description: Mineral oil based, type II electrical insulating oil. Recommended for use in electrical equipment such as distribution, substation transformers, circuit breakers, oil filled capacitors, switches, tap changers, and electrical reclosures.
- Applications: Electrical / Electronic
- Chemistry / Constituents: Petroleum / Mineral Oil
-
Supplier: Toshiba America, Inc.
Description: Toshiba's Oil Insulated Transformer (OIT) is a highly durable and reliable power transformer for electric utilities, electrical transmission, and generation stations. Since pioneering its first transformer in 1894 Toshiba has expanded into a world leader in transformers with an
- Cooling Method: Oil Filled
- Mounting / Form Factor: Pad-Mounted
- Power Rating (VA): 1.00E8 to 8.00E8 VA
-
-
Supplier: Parent Petroleum Co.
Description: larger image Conoco Transformer Oil is a highly refined electrical insulating oil developed for use in oil-immersed transformers, capacitors, tap changers and circuit breakers where the equipment manufacturer specifies a Type II inhibited oil. Transformer
- Kinematic Viscosity: 2.3 cSt
- Type / Function: Hydraulic Oil / Fluid
- Viscosity Index: 43
-
Supplier: Yaohua Electric Group
Description: The technical data 1.1 the type current transformer is a kind of steel tank oil-immersed type of current and electric energy measurement and relaying protection to system with the frequency of 50Hz. 1.2 The current transformer carries out the long operation under
- Transformer Category: Current Transformer
-
Supplier: Accuris
Description: Electrical Insulating Oils
-
Supplier: Accuris
Description: Maintenance of Insulating Oil
-
Supplier: Accuris
Description: Electrical Insulating Oil Analysis
-
Supplier: Aervoe Industries Incorporated
Description: Displaces moisture, formulated with low surface tension
- Applications: Specialty
- Density / Specific Gravity (@15.6°C, 60°F): 0.7000 specific gravity
- Dielectric Strength: 3.50E7 V/m
- Features: Aerosol / Spray, Corrosion Inhibitor / Rust Preventative
-
Description: Covers specifications and test methods for unused mineral insulating oils, as delivered, intended for use in cables with oil ducts. These include hollow core cables, pipe type cables and any others in which provision is made for the oil to flow. Supersedes IEC 60465
-
Description: Section One describes the determination of water in new and used insulated oils over the concentration range 2 mg/kg to 100 mg/kg. Section Two describes methods for the determination of water in oil-impregnated paper and pressboard over the range 0.1% to 20% by mass.
-
Supplier: Parent Petroleum Co.
Description: , Oilgear, Parker Hannifin HPD (formerly Denison Hydraulics), Racine, Sundstrand, Vickers (Eaton) and Voith. The multi-viscosity (MV) grades are specially developed for use in mobile equipment such as cherry pickers, bucket trucks and tree-trimming units operating at very low or high temperatures.
- Kinematic Viscosity: 5.4 cSt
- Type / Function: Hydraulic Oil / Fluid
- Viscosity Index: 104
-
Supplier: Parent Petroleum Co.
Description: , Oilgear, Parker Hannifin HPD (formerly Denison Hydraulics), Racine, Sundstrand, Vickers (Eaton) and Voith. The multi-viscosity (MV) grades are specially developed for use in mobile equipment such as cherry pickers, bucket trucks and tree-trimming units operating at very low or high temperatures.
- Kinematic Viscosity: 6 cSt
- Type / Function: Hydraulic Oil / Fluid
- Viscosity Index: 142
-
Supplier: Parent Petroleum Co.
Description: , Oilgear, Parker Hannifin HPD (formerly Denison Hydraulics), Racine, Sundstrand, Vickers (Eaton) and Voith. The multi-viscosity (MV) grades are specially developed for use in mobile equipment such as cherry pickers, bucket trucks and tree-trimming units operating at very low or high temperatures.
- Kinematic Viscosity: 14.7 cSt
- Type / Function: Hydraulic Oil / Fluid
- Viscosity Index: 98
-
Supplier: Peerless Boilers
Description: The Peerless® Pinnacle® high efficiency, Oil-fired condensing boiler offers 92% efficiency and is ENERGY STAR® compliant. Two firing rates are available â€" .5 GPH and .6 GPH â€" with input ranges from 70,000 BTU/Hr. to 84,000 BTU/Hr. respectively. The
- Fuel Type / Heat Source: Oil
- Heat Output (Capacity): 64000 BTU/hr
- Type: Hot Water
-
Description: Description / Abstract There is no abstract information for this document.
-
Supplier: Aervoe Industries Incorporated
Description: Tough coating, protects & insulates exposed wires & electrical windings
- Chemistry: Epoxy, Resin Base / Polymer Binder
- Coverage: 593 to 1187 ft²
- Cure / Dry Temperature: 50 to 90 F
- Features: Chemical / Oil Resistant, Dielectric, Protective, Sprayable
-
Supplier: Aervoe Industries Incorporated
Description: Displaces moisture, formulated with low surface tension
- Applications: Specialty
- Density / Specific Gravity (@15.6°C, 60°F): 0.8400 specific gravity
- Dielectric Strength: 3.50E7 V/m
- Features: Aerosol / Spray, Corrosion Inhibitor / Rust Preventative
-
Description: IEC 62021-3:2014 describes two procedures for the determination of the acidity of unused and used electrical non-mineral insulating oils. Method A is potentiometric titration and Method B is colourimetric titration. The method may be used to indicate relative changes that occur in non
-
Supplier: Accuris
Description: OIL, ELECTRICAL INSULATING
-
Description: IEC 62701:2014 specifies requirements for recycled mineral insulating oils intended for use in transformers, switchgear, and similar electrical equipment in which oil is required for insulation and heat transfer. These oils are produced by processes employed offsite.
-
Description: Detailed procedures are provided for reclaiming used mineral insulating oils (transformer oils) by chemical and mechanical means to make them suitable for reuse as insulating fluids. Reclamation procedures are described, as are the test methods used to evaluate the
-
Description: ) dielectric insulating oils;the levels at which these methods become necessary; and the routines for restoring oxidation resistance, where required, by the addition of oxidation inhibitors. The intent is to assist the power equipment operator in evaluating the serviceability of
-
Supplier: Richardson RFPD
Description: Type SCRN capacitors are for SCR (silicon controlled rectifier) commutating applications that require high peak and rms current capability. These capacitors are ideal for other high frequency and pulsed applications. The SCRN is supplied in oval or rectangular metal cases with 1/4 x 20 threaded stud
- Capacitance Range: 2 microF
- Electrostatic Capacitors: Oil
-
Supplier: Aervoe Industries Incorporated
Description: Penetrates the surface to loosen rust, corrosion, scale, and dirt
- Applications: Food Grade / Contact (FDA H1)
- Density / Specific Gravity (@15.6°C, 60°F): 0.8000 specific gravity
- Dielectric Strength: 3.00E7 V/m
- Features: Aerosol / Spray
-
Description: Recommendations regarding oil tests and evaluation procedures are made in this guide; references are made to methods of reconditioning and reclaiming conventional petroleum (mineral) dielectric insulating oils; the levels at which these methods become necessary; and the routines
-
Supplier: All-Spec Industries
Description: The Wiha 31430 is an insulated 6 point standard socket set for 3/8" square drive. Wiha 31430 Features: Insulated up to 1000 volts Chrome-vanadium steel, forged and oil-hardened Socket size: 11/32"
- Drive Size: 3/8"
- Drive Type: Square Drive
- Number of Points: 6
- Product Features: Insulated, Standard / Shallow Length Socket
-
Supplier: General Pump
Description: Vehicle Wash as well as many Industrial Applications including Sewer Jetting, Oil and Gas, Mining, Misting and many more. Always striving to serve our customers better, General Pump’s 54,000 square foot headquarters in Minnesota houses a large distribution center along with a manufacturing
- Features: Cold Water, Hot Water / Steam
- Machine Mounting: Handheld
- Process / Operation: Cleaning / Surface Preparation
- Water Flow: 630 GPH
-
Supplier: SAE International
Description: This specification covers an elastomeric silicone insulating and sealing compound, supplied as a two-component system. The compound may be either an addition- or a condensation-cure type.
-
Supplier: CSA Group
Description: Covers specifications and test methods for unused mineral insulating oils, as delivered, intended for use in cables with oil ducts. These include hollow core cables, pipe type cables and any others in which provision is made for the oil to flow. Supersedes IEC 60465
-
Description: Braided tin-plated copper conductor insulated with extruded PVC, TPE or fluoropolymer providing a cable that is resistant to water, oil, acids and solvents. USE: Insulated bonds, grounds, leads, flexible connectors.
- AWG 2/0, 3/0, 4/0 or Larger: Yes
- North American (AWG): 1 to 18 AWG
- Operating Temperature: 105 C
- Rated Voltage: 300 volts
-
Supplier: ASTM International
Description: Method of Test for Peroxide Number of Mineral Insulating Oils (Withdrawn 1986)
-
Supplier: Maxwell Technologies, Inc.
Description: Gas-insulated switchgear (GIS) circuit breakers for tough environments with extreme temperature variations, dust, pollution or confined space use grading capacitors to ensure a uniform distribution of the voltage across the breaking chambers. CONDIS® GIS capacitors have a
- Applications: Other
- Configuration / Form Factor: Heavy Duty / Electric Power Capacitors
-
Description: Heat-Flex Hi-Temp 3500 is a multi-purpose, single component waterbased, acrylic, spray applied insulative coating.It contains an engineered composite of ceramic and silica microspheres to optimize thermal insulative properties. Single component Designed to be applied to hot
- Chemistry: Acrylic / Latex, Resin Base / Polymer Binder
- Cure / Dry Temperature: 77 F
- Features: Brush / Roll-on, Heat Resistant / High Temperature, Sprayable
- Form: Water Based
Find Suppliers by Category Top
Featured Products Top
-
insulating oils. Versatile filtration: Suitable for both full-flow and off-line filtration, providing flexibility to meet different system (read more)
Browse Filter Housings Datasheets for Hilliard Corporation (The) -
Greasy wastewater causes pipe blockages, foul odors, and environmental pollution. Improper disposal of waste oil represents a lost resource and a potential hazard. Our Solid-Liquid-Oil Separator efficiently separates solids, water, and (read more)
Browse Oil and Water Separators Datasheets for KINTEP NEW POWER -
Leading the way with innovative ideas for the Oil & Gas and Petrochemical industries For over 70 years, Conax has designed and manufactured (read more)
Browse Thermocouple Temperature Probes Datasheets for Conax Technologies -
Conventional grease separators are often inefficient, leading to poor separation of oil, water, and solids. Manual oil skimming is labor-intensive and ineffective, frequently resulting in clogged sewer lines and maintenance headaches (read more)
Browse Oil and Water Separators Datasheets for KINTEP NEW POWER -
Leading the way with innovative ideas for the Oil & Gas and Petrochemical industries For over 70 years, Conax has designed and manufactured (read more)
Browse Cable Glands Datasheets for Conax Technologies -
effective. Light weight and rigid, structural foam can be molded with integral skin to give good, dense part surfaces. We can even over-mold a skin of fiberglass-reinforced plastic by using the structural foam to provide a rigid, insulative core for an RTM outer skin. An in-mold gel-coated surface (read more)
Browse Datasheets for Osborne Industries, Inc. -
Oil tank heating can involve different types of process heaters such as circulation heaters, immersion heaters, flange heaters and skid mounted inline heaters. Wattco's development of electric heating products for the oil and gas industry helps customers like you to get alternative (read more)
Browse Industrial Heaters Datasheets for WATTCO -
Insulating Sleeves Metering Pumps Nuclear Power Facilities Oxygen & Other Gas Lines Pressure Measuring Devices Robotics Slurry Transfer Transfer Lines for Clean Liquids (read more)
Browse Plastic Tubing Datasheets for NewAge Performance Products | NAPP -
Extra Flexible Miniature PVC Insulated Lead Wire 600V, 105C Extra flexible stranded bare copper conductor insulated with a .010″ wall of extruded PVC. Resistant to acids, oils, alkalis, solvents and flame. Most constructions also available with tinned (read more)
Browse Electrical Power Wires Datasheets for New England Wire Technologies Corporation -
EP35AOLV is a thermally conductive, electrically insulating compound that withstands aggressive chemicals, such as those found in downhole oil and gas processing. EP35AOLV exhibits superior protection against corrosion in various harsh environments and helps prolong longevity of critical (read more)
Browse Thermal Compounds and Thermal Interface Materials Datasheets for Master Bond, Inc.
Conduct Research Top
-
Using IR on Insulated Pipe System
Insulated pipe condition is very important to the Oil & Petrochemical Industry. This paper will discuss some of the difficulties and possibilities in using IR to assist in determining the condition of insulated pipe in these industries. Pipe is insulated for a number of reasons, the primary reason
-
The Megger Guide to Oil Breakdown Dielectric Testing
Oils that combine a high flashpoint with high dielectric strength have long been used as an insulating medium in. transformers, switchgear and other electrical apparatus. To ensure that the dielectric strength of the oil does not. deteriorate however, proper maintenance is essential, and the basis
-
The Benefits of Removable Insulation Blankets
What Is A Removable Insulation Blanket? Made from layers of insulating material, removable insulation blankets are incredibly versatile and can be used in numerous environments where materials are exposed to high operating temperatures. These removable blankets provide reusable insulation
-
Booklet available: Temperature Control By Means of Fluid Media
Content of this booklet: Theory: Temperature control units; Cooling systems for the plastics industry; Control engineering; Data interfaces; Temperature measurement in the plastics industry; Pumps; Water as a heat-transfer fluid; Treating water for use in heat transfer installations; Thermal oil
-
Design Considerations for Thermal Controls
are designing an oil-filled heater, you. don't want to place the thermal device so close to the heat source that it barely allows the appliance to function. But you don't want it. mounted so far away that the oil in the heater boils creating a potentially hazardous situation for the consumer
More Information Top
-
ASTM MONO2 - Engineering Dielectrics Volume III Electrical Insulating Liquids
Forster CHAPTER 4--Physical and Chemical Properties of Mineral Insulating Oils -M.
-
Recent Trends in the Condition Monitoring of Transformers
Traditional chemical tests are measurements of dielectric strength of insulating oil , neutralization number and interfacial tension.
-
http://dspace.mit.edu/bitstream/handle/1721.1/60145/680744226-MIT.pdf?sequence=2
The majority of high volt- age components, such as paper insulated oil impregnated cables and high voltage power transformers in use today rely on mineral oil, also called transformer oil, as a vital piece of their electrical insulation system [1,55].
-
High voltage technique
the section over the breakdown in insulating oil has undergone a complete new processing 3 because the oil plays a superior role in the insulating technique on the one hand and on the other hand deeplier working physical visions were developed.
-
Subject Index 2013
1,2,3-BENZOTRIAZOLE: Inhibition Technique of Transformer Insulating Oil Degradation – Evaluation of the Effectiveness of Oxidation Degradation Inhibitors .
-
Quantitative analysis ageing status of natural ester-paper insulation and mineral oil-paper insulation by polarization/depolarization current
However, with the increasing number of transformer choosing natural ester as its insulation oil , it is important to investigate the PDC characteristics of natural ester-paper insulation to see whether the PDC technique can also be used to assess the condition of …
-
Subject Index 2010
Suppression of Increase in Electrostatic Charging Tendency of Insulating Oil by Aging Used for Power Transformer Insulation .
-
High Voltage Engineering Testing
Equipment terminations allow the cable to be terminated directly into equipment filled with insulating oil , such as transformers, or sulphur hexafluoride gas, such as gas-insulated switchgear.
Indicates content that may require registration and/or purchase.