Supplier: Measurement Computing
Description: Stand-alone, high-speed 200 kS/s, multifunction data logger; includes a 4 GB SD memory card, USB cable, and external power supply. KEY HIGHLIGHTS The LGR-5320 Series of stand-alone, high-speed, multifunction data loggers provide analog input along with
- Analog Input Channels: 16 #
- Digital I/O Channels: 16 #
- Sampling Frequency: 200 kHz
- Resolution: 16 bits
-
Data Loggers and Data Recorders - Stand Alone, High-Speed, Multifunction Data Loggers -- OM-LGR-5320Supplier: OMEGA Engineering, Inc.
Description: The OM-LGR-5320 Series are highspeed, standalone data loggers for analog and digital signals. Each module offers 16 analog inputs, 16 digital inputs, one single Form C relay (0.5A) digital output for triggering/alarming, and four counter/encoder inputs. These devices allow users to
- Analog Input Channels: 16 #
- Digital I/O Channels: 16 #
- Sampling Frequency: 200 kHz
- Resolution: 16 bits
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: PCE-WB 20SD is a multifunction wet bulb temperature data logger used to measure indoor / outdoor wet bulb globe temperature (WBGT), black globe temperature (TG), wet bulb temperature (WB), dew point temperature, air temperature (TA) and relative humidity. Thus, this multipurpose
- Operating Temperature: 32 to 122 F
- Features: Datalogger / Recorder
- User Interface: Front Panel and Display
- Application: General Lab and Industrial
-
-
Supplier: ValueTronics International, Inc.
Description: The 34952A is a Data Logger from Agilent. Data loggers, or data recorders, collect information over time for a variety of purposes. A data logger uses internal memory and sensors to gather and document information on a 24-hour basis. Receive an
- Features: Datalogger / Recorder
-
Data Loggers and Data Recorders - USB Temperature, Humidity and Pressure Data Logger -- TandD TR-73USupplier: CAS DataLoggers
Description: makes this product the foundation of our Thermo Recorder line. The product is an all-in-one package that includes the data logger unit, sensor and software. Simply by connecting to a PC via a USB connection and carrying out a few easy steps, the measurement and recording of data
- Operating Temperature: 14 to 140 F
- Features: Application Software Included, Datalogger / Recorder, Other Input, Thermistor Input
- User Interface: Computer Programmable, Front Panel and Display
- Application: General Lab and Industrial
-
Supplier: CAS DataLoggers
Description: The RTR-574 Wireless Temperature Humidity Light Data Logger includes two sensors that simultaneously measure and record illuminance / UV intensity and temperature/humidity. This Data Logger allows for the measuring and recording of the above items in various places such
- Operating Temperature: 14 to 140 F
- Features: Application Software Included, Datalogger / Recorder, Other Input, RTD Input, Thermistor Input
- User Interface: Computer Programmable, Front Panel and Display
- Application: General Lab and Industrial
-
Supplier: Holykell Technology Company Limited
Description: HOLYKELL's "paperless" data logger is developed based on RJ45, printer or USB interface. It can not only provide on-site measurement data, but also recall historical data. Support standard voltage, current, resistance temperature measurement or millivolt signal output.
- Display Type: Dot Matrix Display
-
Supplier: Cole-Parmer
Description: and dual pressure combinations with additional probes sold separately. All probes are interchangeable in the field
no need to calibrate or adjust. |Datalogger allows you to send data out to a printer or a computer. The print mode filters the data and only prints out readings - Features: Datalogger / Recorder
- User Interface: Front Panel and Display
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: Multifunction Calibrator PCE-789 Multifunction Calibrator that measures and simulates current and voltage signals and thermocouples / integrates a function generator for specific waveforms / large graphical display with backlight / data logger function The PCE-789
- DC Voltage Range: 0.01 to 15 volts
- DC Current Range: 0.004 to 0.024 amps
- Operating Temperature: 32 to 122 F
- Calibration Signal: DC Current, DC Voltage
-
Supplier: ValueTronics International, Inc.
Description: including: Handheld and bench multimeters Oscilloscopes Wattmeters Analog,volt/ohm/amp/watt instruments Electronic thermometers Data loggers Strip chart recorders Power harmonics analyzers Process calibrators Current clamps and related instruments The Fluke 5500A is a revolutionary
- Physical Properties: Acoustic (Microphones)
- Calibrator Style: Hand Held
- Environmental Properties: RTD, Thermistor, Thermocouple
-
Supplier: DigiKey
Description: Multifunction I/O Datalogger USB 2.0
- Features: DC Voltage Input, Datalogger / Recorder
-
Supplier: Marsh Bellofram Group of Companies
Description: Functions As Timer or Counter Five Time Ranges Six Single-Cycle and Eight Repeat-Cycle Timing Modes Sealed Faceplate Cycle Counter Count Input Scaling Data Retention Memory with EEPROM Circuitry. (653-8-2000, 653-8-2001 Models) Data Retention Memory with Lithium Battery (653-8-3000,
- Number Input Channels: 2
- Number of Digits (or Characters): 4
- Operating Temperature: 32 to 140 F
- Minimum Time Setting: 0.0010000000000000022 seconds
-
Supplier: SOCOMEC
Description: DIRIS A60 is a panel mounted multifunction meter which incorporates all functions of the DIRIS A40 with the addition of enhanced data logging functions, recording curves for quality events. All this information can be analysed remotely using the Analysis software which is available at
- Accuracy: 0.2 % FS
- Operating Temperature: 14 to 131 F
- Features: Datalogger / Recorder
- Network Options: Ethernet
-
Supplier: Transcat, Inc.
Description: temperature probes and other measuring devices. The calibration data are stored in the instrument’s memory. The communication with a PC is used to remotely control the unit and to download the calibration reports. The Pascal ET is the most advanced portable multifunction calibrator for
- Calibrator Style: Hand Held
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: The accelerometer sensor can be set flat, equipped with a magnet or combined with the included fastening screw to make contact with a surface during vibration measurement. Internal frequency filters eliminate the effects of background noise, allowing the device to detect specific vibrations. Note:
- Rotational Speed Range: 0.5 to 99,999 rpm
- Operating Temperature: 32 to 122 F
- Features: Application Software, Battery Powered, Data Logger
- Sensor Technology: Contact
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: separately, as is an optional mains adapter for power and a software kit with an RS-232 cable. The pH meter acts as a real-time data logger. All values can be stored directly on the included SD card in Microsoft Excel format or transferred to a PC by means of the RS-232 port. Thus, no
- pH Range: 0 to 14 ph
- pH Accuracy: 0.02 (+/- % FS)
- Operating Temperature: 32 to 122 F
- Body Material: Epoxy or Polymer
-
Supplier: Transcat, Inc.
Description: temperature probes and other measuring devices. The calibration data are stored in the instrument’s memory. The communication with a PC is used to remotely control the unit and to download the calibration reports. The Pascal ET is the most advanced portable multifunction calibrator for
- Calibrator Style: Hand Held
-
Supplier: Transcat, Inc.
Description: settings and statistical results Logger and log-data transfer to USB stick or communication interface Scan function with a live screen and graph Communication interfaces available for automated monitoring and calibration applications USB, Ethernet, RS-232
-
Supplier: Process Sensing Technologies USA
Description: The HygroPalm HP23-A is the high-end product in our range of handheld instruments. In addition to measuring humidity and temperature, it also calculates all psychrometric parameters and provides a variety of additional functions. The HP23-A is a full-function data logger and has the
- Form Factor: Meter / Indicator
-
Supplier: Radwell International
Description: MULTIFUNCTION MODULE; ACCESSORY TYPE:MULTIFUNCTION MODULE; FOR USE WITH:KEYSIGHT 34970A DATA LOGGER; PRODUCT RANGE:-; FEATURES:16 BITS OF DIGITAL INPUT AND OUTPUT, 100KHZ TOTALIZER INPUT, 2 ª12V ANALOG OUTPUTS ROHS COMPLIANT: YES. FREE 2 YEAR RADWELL WARRANTY
-
Supplier: Transcat, Inc.
Description: Product Highlights 4-digit multifunction LCD with analog bargraph Precise linearity over wide range (100dB) Display modes: SPL, SPL MIN/MAX, SEL, and Leq Programmable integrating time A and C Frequency weighting Impulse/Fast/Slow response settings Datalogging function records up to 32,000
- Features: Datalogger / Recorder
-
Supplier: SOCOMEC
Description: DATALOG H40 and H60 dataloggers associated with Socomec wireless interfaces enable you to create a smart energy data communication network in order to : • Remotely and automatically read multi-fluid energy meters and multi-function meters, isolated or not. • Centralise, secure and make
- Operating Temperature: 23 to 122 F
- Features: Datalogger / Recorder
- Network Options: Ethernet
- User Interface: None
-
Supplier: Trumeter Company, Inc.
Description: High visibility supertwist LCD display can be viewed from any angle Backlight programmable ON, OFF or AUTO 40 years data retention with no power Programmable decimal point up to 3 places Operates from 85-265VAC or 10-26VDC 12VDC output to drive a sensor (when AC powered) Opto-isolated inputs
- Number of Digits (or Characters): 6
- Digit Height: 0.2755905511811024 inches
- Operating Temperature: 14 to 140 F
- Reset: Auto Reset, Manual
-
Supplier: Busch Vacuum Solutions
Description: correction factor, pressure units, setpoints and other beneficial functions are easily adjustable. Automatic identification of active gauges Data logger and parameter settings via USB Full remote control via VacTest explorer software RS232 and USB interfaces Worldwide compatibility EMI
- Number of Inputs: 4 inputs
- Number of Control Outputs: 2 outputs
- Interface: Computer Programmable
- Type: DC Voltage Input, Serial / Digital Input
-
Supplier: Electro-Sensors, Inc.
Description: Full Logic Control Process Counter Features • Displays process, batch, total, and rate • Full diagnostic functions • Three programmable transistor setpoint outputs and AC inputs • Non-volatile memory • Keypad lockout • ETL approved to applicable UL and CSA standards The CT6000 is completely field
- Number Input Channels: 2
- Maximum Count Frequency: 20 kHz
- Number of Digits (or Characters): 6
- Digit Height: 0.3 inches
-
Supplier: InspectorTools
Description: Kestrel 4200 air flow meter features a powerful data logger that records 1600 sets of measurements at user-selectable time intervals (over 2 years of data can be recorded). Logged data can be reviewed with the 4200’s on-screen graphing capabilities, or uploaded to a PC
-
Supplier: InspectorTools
Description: laptop making long-term storage, in-depth analysis, and detailed charting of stored data a breeze. Screen Shots Features Waterproof and floats Backlight for low light conditions Data Logger (automatic and manual) Customizable data storage - 1600 data points
-
Supplier: OMEGA Engineering, Inc.
Description: turned on. No computer setup is necessary to start logging, and all logging settings can be viewed or changed through the front panel functions. When the internal memory becomes full the recording rolls over, overwriting the oldest recorded data. Logged data can be reviewed on a
- Relative Humidity Range: 0 to 95 %
- Relative Humidity Accuracy: 2 %
- Operating Temperature: -40 to 140 F
- RH/aw Range: 0 to 95 %
-
Supplier: AMETEK Sensors, Test & Calibration
Description: multifunction workload coverage, enabling calibration of data loggers, strip chart recorders, multi-meters, handheld calibrators, and other industrial instruments. This is the cost-effective solution for your multiple calibration needs. Laboratory standard for electrical
- DC Voltage Range: 0.001 volts
- DC Current Range: 0.001 amps
- User Interface: Computer Interface, Digital Front Panel
- Calibration Signal: DC Current, DC Voltage
-
Supplier: InspectorTools
Description: bulb temperature Density altitude Wind chill Air, water, and snowtemperature°F or °C Current, average, and maximum air velocity Kestrel 4500 Additional Features Waterproof and floats Time and date Easy- to-read backlit display Data Logger (automatic and manual) Customizable data
-
Supplier: Allied Electronics, Inc.
Description: 1 million readings of volatile memory in addition to 50,000 reading of non-volatile memory, you now have the ability to capture low-frequency waveforms, characterize device performance and transfer results for analysis on your computer. A front panel data logger function allows you to
-
Supplier: Allied Electronics, Inc.
Description: Real-time math and statistics are included, and a peak-detect capability allows you to capture peaks as short as 20 µs. A front panel data logger function allows you to set the meter up to make unattended, paced measurements over a fixed time or number of events, then pull up the
Find Suppliers by Category Top
More Information Top
-
Rapid MPN-Qpcr Screening for Pathogens in Air, Soil, Water, and Agricultural Produce
The airflow was detected by the anemometer option on a Kimo AMI300 ( Multifunction Data Logger , North Yorkshire, UK).
-
Surrogate Human Tissue Temperatures Resulting From Misalignment of Antenna and Implant During Recharging of a Neuromodulation Device
The data were read by a mul- tifunction data logger and transmitted to a personal computer for display and post-processing.
-
Microcomputer controlled scanning reference electrode technique apparatus developed to study pitting corrosion of as turbine disc materials
A multi- function data logger provided real time data acquisition, a stable base line was obtained by ac coupling the signal to the logger via the signal conditioning .
-
A noise-driven attractor switching device
All data of output voltage for the attractor switch- ing electronic circuit (Figs. 1 and 3) were collected by a multifunction data logger (USB-6008; 12-bit longitu- dinal digital resolution; maximum sampling rate of 10 kS/sec, National Instruments, Corp.), which…
-
Investigation of the Thermal Characteristics of a Circular Fusible-Type Sprinkler Using the Energy Transport Equation
The gas temperature and the surface temperature of the element are recorded by a multifunction data - logger (Delta Ohm, DO9847, Caselle di Selvazzano, Padova, Italia).
-
Features :: NASA Tech Briefs
Measurement Computing Corp., Norton, MA, has introduced the LGR-5320 series of standalone, multifunction data acquisition loggers .
-
Articles :: NASA Tech Briefs
Measurement Computing Corp., Norton, MA, has introduced the LGR-5320 series of standalone, multifunction data acquisition loggers .
-
LGR-5320 - Nasa Tech Briefs :: NASA Tech Briefs
Measurement Computing Corp., Norton, MA, has introduced the LGR-5320 series of standalone, multifunction data acquisition loggers .
-
Features :: NASA Tech Briefs
Measurement Computing Corp., Norton, MA, has introduced the LGR-5320 series of standalone, multifunction data acquisition loggers .
-
Features :: NASA Tech Briefs
Measurement Computing Corp., Norton, MA, has introduced the LGR-5320 series of standalone, multifunction data acquisition loggers .
Indicates content that may require registration and/or purchase.