-
Supplier: Classic Automation LLC
Description: No Description Provided
- Data Acquisition: I/O Module
-
Supplier: Pepperl+Fuchs SE
Description: G4 module IP65 4 inputs for Pt100
-
Supplier: Classic Automation LLC
Description: TI 505 - 505- 2555 16 Pt. Differential Analog Input Module
- Data Acquisition: I/O Module
-
-
Supplier: Classic Automation LLC
Description: Micro Innovation XI/ON - Analog input module, 8 U/I or 4 Pt/Ni
- Data Acquisition: I/O Module
-
Supplier: Classic Automation LLC
Description: INTERBUS- ST analog input module, 4 inputs, RTD, 2
- Data Acquisition: I/O Module
-
Supplier: Allen-Bradley / Rockwell Automation
Description: 8 Channel Analog Current/Voltage Input Module
- Form Factor: DIN Rail, Panel / Chassis Mount
- Data Acquisition: Input Module
-
Supplier: Newark, An Avnet Company
Description: ANALOG PT MODULE RMC +OPTIONS
-
Supplier: Sichuan Odot Automation System Co., Ltd.
Description: · The module supports channel disable, support the PT-100 2-wire or 3-wire. · The filter level of module is adjustable. · The module supports fault detection (disconnection, short circuit, overflow, underflow, terminal state). · Module high speed redundant backplane bus
- Analog Input Channels: 4 #
- Operating Temperature: -31 to 140 F
- Application: Aerospace / Military, Environmental, General Lab and Industrial, Marine, Medical / Biomedical, Seismic / Geotechnical, Vehicular, Weather / Meteorology
- Features: B, E, J, K, N, R, S, T, Temperature Signal Conditioners
-
Supplier: Sichuan Odot Automation System Co., Ltd.
Description: Module features ◆ The module supports 3-channel RTD thermal resistance (PT1000) temperature acquisition ◆ The module could be connected to a 2-wire or 3-wire PT1000 temperature sensor ◆ The internal bus of the module and field input adopts magnetic isolation ◆ The
- Analog Input Channels: 3 #
- Resolution: 15 bits
- Accuracy: 0.5 % FS
- Operating Temperature: -31 to 158 F
-
Supplier: Beckhoff Automation LLC
Description: The EJ3202 EtherCAT plug-in module allows resistance sensors to be connected directly. The module's circuitry can operate 2- and 3-wire sensors. A microprocessor handles linearization across the whole temperature range, which is freely selectable. The EJ3202’s standard settings are:
- Data Acquisition: I/O Module
-
Supplier: Beckhoff Automation LLC
Description: The EJ3214 EtherCAT plug-in module allows four resistance sensors to be connected directly. The module's circuit can operate sensors using the 2- or 3-wire technique. A microprocessor handles linearization across the whole temperature range, which is freely selectable. The EJ3214’s
- Data Acquisition: I/O Module
-
Supplier: Kistler Group
Description: Measurement module (DAQ) for RTD (Pt100, Pt1000) or resistance in 3or 4wire technique.* Suitable for KiDAQ Data Acquisition system types Portable, Rack and DIN Rail. 4 analog input channels Galvanic isolation 500 VDC A/D conversion: 10 Sps sampling rate per channel, 24 Bit
- Analog Input Channels: 4 #
- Sampling Frequency: 0.01 kHz
- Resolution: 24 bits
- Accuracy: 0.01 % FS
-
Supplier: Sichuan Odot Automation System Co., Ltd.
Description: Module features ◆ The module supports 4-channel RTD thermal resistance (PT100) temperature acquisition ◆ The channels are isolated, and the isolation voltage is 1500V ◆ The module could be connected to a 2-wire or 3-wire PT100 temperature sensor ◆ The internal bus
- Analog Input Channels: 4 #
- Resolution: 15 bits
- Accuracy: 0.5 % FS
- Operating Temperature: -31 to 158 F
-
Supplier: Dataforth Corporation
Description: Two MAQ20 resistance input modules are offered. One interfaces to 3-wire sensors and has 6 input channels; the other interfaces to 4-wire sensors and has 5 input channels. The 3-wire module interfaces to 3 types of sensors: 100Ù Pt and 120Ù Ni RTDs, and potentiometers; the 4-wire
- Analog Input Channels: 5 #
- Operating Temperature: -40 to 185 F
- Form Factor: DIN Rail
- Application: General Lab and Industrial
-
Supplier: CAS DataLoggers
Description: The DigiRail-2A Analog Input Module signal condition and digital transmitters with Modbus RTU communication interface provide a simple way for integrating analog signal to supervisory systems. Featuring two universal input analog signal channels it is the most economical
- Analog Input Channels: 2 #
- Operating Temperature: 32 to 158 F
- Sampling Frequency: 0.01 kHz
- Resolution: 17 bits
-
Supplier: Measurement Computing
Description: Analog isolation module, true RMS input, 0 to 100 mV input, 0 to 5 V output.
- Features: DC Voltage Input
- Application: General Lab and Industrial
- Filter / Amplifier: Integral Amplifier
- Isolation: Isolated Analog Voltage Input
-
Supplier: Beckhoff Automation LLC
Description: The KL3204 analog input terminal allows resistance sensors to be connected directly. The Bus Terminal’s circuitry can operate the sensors using 2-wire connection techniques. Linearization over the full temperature range is realized with the aid of a microprocessor. The temperature range can
- Data Acquisition: I/O Module
-
Supplier: Beckhoff Automation LLC
Description: The KL3201 analog input terminal allows resistance sensors to be connected directly. The Bus Terminal’s circuitry can operate the sensors using 2-wire or 3-wire connection techniques. Linearization over the full temperature range is realized with the aid of a microprocessor. The temperature
- Data Acquisition: I/O Module
-
Supplier: Opto 22
Description: The SNAP-AIARMS-i module provides two isolated channels with an input range of 0 to 10 amps RMS AC/DC. An ideal input is the 5-amp secondary of a standard current transformer used to monitor AC line current. The module may also be used to monitor AC current to greater than a 100-amp
- Analog Input Channels: 2 #
- Sampling Frequency: 0.030959752321981424 kHz
- Accuracy: 0.2 % FS
- Operating Temperature: 32 to 158 F
-
Supplier: Acromag, Inc.
Description: or bipolar voltage output. And for greater flexibility, the IP230A module accepts conversion start triggers from software commands, or from external sources for synchronization to specific events. Features IP230A-4: 4 analog voltage output channels IP230A-8: 8 analog voltage
- Number of Channels: 4 to 8
- Throughput Rate: 0.1 MHz
- Module Voltage: -12 V, 12 V, 5 V
- Bus Width: 16-bit
-
Supplier: Campbell Scientific, Inc.
Description: The CR9058E is a ±60 V Input Module for the CR9000X-series or CR9000-series Measurement and Control Systems. The CR9058E has 10 differential inputs; each channel has its own isolation ground, which can be used to connect a shielded cable. The CR9058E has an on-board RTD to provide a reference
- Analog Input Channels: 10 #
- Operating Temperature: -40 to 158 F
- Features: DC Voltage Input
- Differential Channels: Differential Channels
-
Supplier: INTEG Process Group, Inc.
Description: The JNIOR platform of Ethernet I/O modules is more than just I/O. Starting with a core complement of digital I/O, the user can now easily add analog signals at any time. The JNIOR provides the central controller for seamlessly integrating the analog expansion modules. The
- Data Acquisition: I/O Module
-
Supplier: Microstar Laboratories, Inc.
Description: Analog Output Signal Interface Modules connect to the Data Acquisition Processor's digital connector. If digital input/output is needed in addition to analog output expansion, a Digital Signal Interface Module is required. There are several cabling options for the MSXB
- Data Acquisition: Output Module
-
Supplier: Advantech
Description: 8-channel High-speed Analog Input Module Accuracy: ±0.1% or better Effective resolution: 12-bit plus sign bit 1000 Hz bandwidth High sampling rate:ADAM-5000/485&5000E: 100 samples/sec, ADAM-5510 & ADAM-5511: 8000 samples/sec max 3000VDC Isolation voltage protection Distinct range
- Sampling Frequency: 100 kHz
- Resolution: 12 bits
- Accuracy: 0.1 % FS
- Features: DC Current Input, DC Voltage Input, Other Input
-
Supplier: Allen-Bradley / Rockwell Automation
Description: 8 Channel Analog Voltage Output Module- Conformally Coated
- Data Acquisition: Output Module
-
Supplier: Allen-Bradley / Rockwell Automation
Description: 4 Channel Analog Voltage Isolated Output Module
- Form Factor: DIN Rail, Panel / Chassis Mount
- Data Acquisition: Output Module
-
Supplier: OMEGA Engineering, Inc.
Description: The DRP-8500 Series modules offer a low cost analog I/O solution for micro PLCs. The series is ideal for discrete automation applications requiring one or two analog I/O channels. All models in the series interface with the PLC high speed counter inputs or pulse outputs. Digital
- Features: 100Ω, 2-Wire, 3-Wire, DC Current Input, DC Voltage Input, Frequency Input, J, K, Other, Platinum, Temperature Signal Conditioners, Voltage-to-Frequency Converter
- Outputs: Current Output, Frequency Output, Voltage Output
- Form Factor: DIN Rail
- User Interface: None
-
Supplier: Gantner Instruments, Inc.
Description: logging purposes. With a controller, multiple Q.raxx XL systems can be synchronized to each other allowing for efficient DAQ distribution with low jitter and gradual expansion up to thousands of channels. High Density up to 13 I/O modules per Q.raxx 3U chassis with up to 16 channels per I/O
- Digital I/O Channels: 4 #
- Resolution: 16 bits
- Accuracy: 0.02 % FS
- Transmission Rate: 48,000 kbps
-
Supplier: Acromag, Inc.
Description: 8 voltage output channels Individual D/A converters on each channel 10µS settling time Selectable output range (±5V, ±10V, 0-10V) IP235A modules have a 16-bit D/A converter (DAC) to provide highly-accurate analog voltage outputs. An internal RAM buffer enhances control over the
- Analog Input Channels: 8 #
- Resolution: 16 bits
- Accuracy: 0.0061 % FS
- Operating Temperature: 32 to 158 F
-
Supplier: Acromag, Inc.
Description: 0-11mA, 0-20mA, 4-20mA, ±20mA, or 0-20 amps AC Input 8 analog differential current input channels 12 to 32V DC Power (2.8W) XT1211: Modbus/TCP and i2o protocol XT1212: Ethernet/IP protocol XT1213: Profinet protocol The XT1210 offers an isolated Ethernet network interface for up to eight
- Analog Input Channels: 8 #
- Accuracy: 0.05 % FS
- Transmission Rate: 12,000 kbps
- Operating Temperature: -40 to 158 F
-
Supplier: Vaisala
Description: For Environmental Chambers Practically maintenance-free HMM100 is an open frame module for integration into environmental chambers. Excellent measurement accuracy with Vaisala HUMICAP® 180R sensor. Features • Full temperature compensation over the operating temperature range of -70˚C ...
- Relative Humidity Range: 0 to 100 %
- Relative Humidity Accuracy: 2 %
- Operating Temperature: -94 to 356 F
- Electrical Outputs: Analog Current
-
Supplier: Radicom Research, Inc.
Description: Features: 24 bit ADC DIP/SMD module for analog signal input from external sensor. 16 bit DAC DIP/SMD module to outside signal. RoHS compliant Introduction: Radicom Research’s RS1001MB series is the perfect wireless solution for integrating sensor applications into the Bluetooth
-
Supplier: Newark, An Avnet Company
Description: MEMS Module Function:Tri-Axis Gyroscope, Tri-Axis Accelerometer; Supply Voltage Min:3.15V; Supply Voltage Max:3.45V; Sensor Case Style:Module; No. of Pins:14Pins; Gyroscope Range:± 100°/s; Acceleration Range:± 5g; Product Range:- RoHS Compliant: Yes
-
Supplier: WAGO
Description: 2-channel analog input; For Pt100/RTD resistance sensors
- Operating Temperature: 32 to 131 F
- Data Acquisition: Input Module
Find Suppliers by Category Top
Featured Products Top
-
The module supports 3-channel RTD thermal resistance (PT1000) temperature acquisition The module could be connected to a 2-wire or 3-wire PT1000 temperature sensor The internal bus of the module and field input adopts magnetic isolation The module carries with 3 analog input channel LED indicator 15-bits ADC resolution (read more)
Browse I/O Modules and Instruments Datasheets for Sichuan Odot Automation System Co., Ltd. -
The module supports 3-channel RTD thermal resistance (PT100) temperature acquisition The module could be connected to a 2-wire or 3-wire PT100 temperature sensor The internal bus of the module and field input adopts magnetic isolation The module carries with (read more)
Browse I/O Modules and Instruments Datasheets for Sichuan Odot Automation System Co., Ltd. -
? The module supports 4-channel RTD thermal resistance (PT100) temperature acquisition ? The channels are isolated, and the isolation voltage is 1500V ? The module could be connected to a 2-wire or 3-wire PT100 temperature sensor ? The internal bus of the module and field input adopts magnetic isolation ? The module carries with 4 analog input channel LED indicator ? 15-bit ADC resolution (read more)
Browse I/O Modules and Instruments Datasheets for Sichuan Odot Automation System Co., Ltd. -
Using the ibaPADU (Parallel Analog Digital Unit) device family, analog and digital signals can be acquired and recorded with high precision by the data acquisition system ibaPDA. Fast and synchronous sampling of all signals allows detailed analyzing of all processes. (read more)
Browse Data Input Modules Datasheets for iba America LLC -
costs. Measures AC Measure up to 100 A contactless Analog & Digital Compatible with IO-Link and analog, get the best of both worlds Measure Electricity Consumption Monitor consumption and be able to detect (read more)
Browse I/O Modules and Instruments Datasheets for STEGO -
monitoring environments in offices, hospitals, classrooms, and warehouses. Heat Probe Sensor The EVA-2311 uses a PT1000 round head (read more)
Browse I/O Modules and Instruments Datasheets for Advantech -
up to 32 ODOT C-series remote I/O expansion modules. You can flexibly combine various modules—such as digital input/output, analog input/output, temperature measurement, and motor control—to build a customized data acquisition and control system tailored to your specific application (read more)
Browse I/O Modules and Instruments Datasheets for Sichuan Odot Automation System Co., Ltd. -
Fully compliant with the standard EtherCAT protocol, the DN-8033 supports high-speed communication at 100 Mbps. It functions as a versatile EtherCAT slave, supporting SDO master configuration directly via the controller software, ensuring effortless integration with masters from (read more)
Browse I/O Modules and Instruments Datasheets for Sichuan Odot Automation System Co., Ltd. -
for SIL3/PLe applications. Engineered to be used with our PFC Basic Controller 100, PFC100, PFC200, and PFC300, the internal logic is programmable via WAGO’s I/O CHECK and Safety Editor Software. These modules redefine safety integration achieving high-level safety without the need for a dedicated safety PLC—saving time, space, and cost. (read more)
Browse I/O Modules and Instruments Datasheets for WAGO -
The new WAGO Compact Controller 100 with real-time Linux® provides users with complete freedom: It can be freely programmed using CODESYS or used for IEC 61131-independent engineering with tools like Node-RED, Python, or C++. Docker® can also be easily installed later on the device as a (read more)
Browse I/O Modules and Instruments Datasheets for WAGO
More Information Top
-
AM2 PT100 - Entries - Siemens Industry Online Support – Siemens AG
The range of AM2 PT100 analog module is -50...200C .
-
Scaling Question - Entries - Siemens Industry Online Support – Siemens AG
• PT100... is only near the PT100 analog input module possible .
-
Maglev Trains
For example, the airport line light rail air-conditioning control system mainly uses 8 24 VDC digital input module, 8 24 VDC digital output module with delay, and 4 2 mA Pt100 /Pt1000 temperature collection analog input module .
-
PT 100 Multiplexer - Entries - Siemens Industry Online Support – Siemens AG
g) Altenative to f3) now i can give you a better methode, special for use with analog inputs from AM2 ( PT100 ) module with 50 ms actualisation time.
-
AI CARD SCALING - Entries - Siemens Industry Online Support – Siemens AG
I have used FC105 for scaling analog values, bu never used a module for PT100 .
-
Mixing analog, digital and different modules - Entries - Siemens Industry Online Support – Siemens AG
In that case, what input numbers will the inputs on the AM2 PT100 module get if I use one or more analog inputs on the 24RCo?
-
The XFEL RF interlock system
This module has been designed to interface with analog input Rear IO Modules f.ex. PT100 and 4-20mA.
-
Consecutive reactions of aromatic-OH adducts with NO, NO2 and
O2: benzene, naphthalene, toluene, m- and p-xylene,
hexamethylbenzene, phenol, m-cresol and anili...
Since multiplexing the temperature signals at the sensor level proved to be unreliable, separate converter modules ( Analog Devices, 5B34) for each Pt100 resistor were multiplexed at the 5-V level (Analog Devices, 5B02).
-
Schneider Electric Expands Zelio Product Family For Increased Flexibility
Users can easily convert signals from Type J or K thermocouples or Pt100 probes to useful analog signals with the Zelio analog interface modules .
-
Siemens - 6BK17000BA000AA1 - PLCs & Accessories - Logic Modules - Allied Electronics
Heating and cooling systems can be designed with the RTD PT100 module using special functions for PI control, ramp response and analog multiplexer.
Indicates content that may require registration and/or purchase.