-
Supplier: Accuris
Description: OUTLINE OF INVESTIGATION FOR CEMENTITIOUS MATERIALS USED FOR RESURFACING SMOKE CHAMBER OF MASONRY FIREPLACES
-
Supplier: Accuris
Description: Fire Tests - Reaction to Fire - Smoke Generated by Building Products (Dual-Chamber Test)
-
Supplier: Radwell International
Description: CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR, NON-DIRECTIONAL SMOKE CHAMBER, 360 DEGREE VIEWOF DETECTOR STATUS LED, LOW PROFILE, 2" HIGH (WITH BASE), LOW STANDBY CURRENT, 59A AT 24VDC. FREE 2 YEAR RADWELL WARRANTY
-
-
Supplier: Accuris
Description: Plastics - Smoke Generation - Part 2: Determination of Optical Density by a Single-Chamber Test
-
Supplier: United Technologies Corporation
Description: CARBON MONOXIDE FIRE AND SMOKE ALARM TYPE IONIZATION (SMOKE), ELECTROCHEMICAL (CARBON MONOXIDE) OPERATION TYPE UL APPROVAL 85 DB AT 10 FT HORN TYPE (3) AA BATTERY VOLTAGE RATING/SOURCE TOTALINE[R] BRAND SIZE 5.75 INCH DIA X 1.7 INCH D TEMPERATURE RATING 40 TO 100 DEG F KN-COSM-XTR-B
-
Supplier: Accuris
Description: Plastics - Smoke Generation - Part 2: Determination of Optical Density by a Single Chamber Test
-
Supplier: Conspec Controls Inc.
Description: CONSPEC Smoke Monitor
- Operating Voltage Range: 12 to 24 volts
- Power Supply: AC, DC
- Market: Industrial
- Features: Interconnectable, Other
-
Description: Essential for fire test labs and manufacturers, up-to-date testing criteria in new NFPA 270 helps users evaluate the extent of smoke obscuration. NFPA 270: Standard Test Method for Measurement of Smoke Obscuration Using a Conical Radiant Source in a Single Closed Chamber
-
Supplier: CSA Group
Description: ISO 5659-2:2017 specifies a method of measuring smoke production from the exposed surface of specimens of materials or composites. It is applicable to specimens that have an essentially flat surface and do not exceed 25 mm in thickness when placed in a horizontal orientation and subjected to
-
Supplier: DigiKey
Description: ADPD188BI - Smoke Chamber
-
Description: ISO 5659-2:2012 specifies a method of measuring smoke production from the exposed surface of specimens of materials, composites or assemblies. It is applicable to specimens that have an essentially flat surface and do not exceed 25 mm in thickness when placed in a horizontal orientation and
-
Supplier: UL Standards & Engagement
Description: regulations of the United States Coast Guard. 1.2 A single station smoke alarm (e.g. ionization-type, photoelectric-type, smoke alarm with supplementary heat detection type, combination smoke type, multi-criteria type), as defined by these requirements, is a self-contained fire
-
Supplier: Sanuvox Technologies, Inc.
Description: also designed to help reduce smoke buildup by continuously drawing air through a UV chamber. The controller automatically turns on and off a second lamp to actively deal with the increase or decrease of smoke. Ash will be captured on the filters, nicotine droplets will be
- Application: Commercial
- Technology: Ultraviolet Germicidal Irradiation (UVGI)
-
Supplier: ASTM International
Description: to specified levels of thermal irradiance, from a conical heater, in the presence of a pilot flame, in a single closed chamber. Optional testing modes exclude the pilot flame. 1.3 The principal fire-test-response characteristic obtained from this test method is the specific optical density of
-
Supplier: Sanuvox Technologies, Inc.
Description: Designed to help reduce airborne viruses, bacteria, mold and germs. Using a state-of-the-art patented UV technology, this portable air purifier can clean up to 800 cu.ft. The variable speed blower of the Biopür moves the air through a series of filters, then into the reflection chamber so
- Technology: Portable, Ultraviolet Germicidal Irradiation (UVGI)
- Application: Residential
-
Supplier: ASTM International
Description: 1.1 This fire-test-response standard covers determination of the specific optical density of smoke generated by solid materials and assemblies mounted in the vertical position in thicknesses up to and including 1 in. (25.4 mm). 1.2 Measurement is made of the attenuation of a light beam by
-
Description: density of smoke produced by materials exposed vertically to a radiant heat source with or without the application of a pilot flame in a closed chamber (i.e. without air-change). Has the status of a basic safety publication in accordance with IEC Guide 104.
-
Description: Provides details of the test apparatus to be used for measuring smoke emission when electric or optical fibre cables are burnt under defined conditions, for example, a few cables burnt horizontally. The light transmittance (lt) under flaming combustion and smouldering conditions can be used
-
Supplier: RS Components, Ltd.
Description: SmokeChamber
-
Description: IEC/TS 60695-2-30:2013 describes the apparatus, calibration procedures and basic experimental procedures for the determination of the specific optical density of smoke produced by materials exposed vertically to a radiant heat source with or without the application of a pilot flame. The test
-
Supplier: CSA Group
Description: IEC 61034-1:2005+A1:2013 Provides details of the test apparatus to be used for measuring smoke emission when electric or optical fibre cables are burnt under defined conditions, for example, a few cables burnt horizontally. The light transmittance (lt) under flaming combustion and smouldering
-
Supplier: AENOR
Description: Plastics - Smoke generation - Determination of optical density by a single-chamber test (ISO 5659:2026)
-
Supplier: AENOR
Description: Plastics - Smoke generation - Part 2: Determination of optical density by a single-chamber test (ISO 5659-2:2006)
-
Supplier: AENOR
Description: Plastics - Smoke generation - Part 2: Determination of optical density by a single-chamber test (ISO 5659-2:2012)
-
Supplier: Premier Lighting & Production Company
Description: This machine produces low-lying smoke without the inconvenience of dry ice. Place up to 22 lbs. of ice into the ice chamber to cool the smoke produced by the 1000W smoke machine contined in the unit and watch the floor disappear. A full ice chamber can last up to
-
Supplier: AENOR
Description: Plastics - Smoke generation - Part 2: Determination of optical density by a single-chamber test (ISO 5659-2:2017)
-
Supplier: Premier Lighting & Production Company
Description: This machine produces low-lying smoke without the inconvenience of dry ice. Place up to 22 lbs. of ice into the ice chamber to cool the smoke produced by the 1000W smoke machine contined in the unit and watch the floor disappear. A full ice chamber can last up to
-
Supplier: Mystaire, Inc.
Description: Isola™ EDGE Filtered Chemical Workstation was designed and engineered to provide the end user with superior filtration while offering the same conveniences found on traditional laboratory hoods. The main chamber is dual-wall thermally-fused solid polypropylene allowing the installation of
- Separation / Filtration System: Cartridge-type Units
- Collector Type: Downdraft Table
- Process: Dry
- Features: Fume / Smoke Collector, HEPA / ULPA Filters
-
Supplier: Sentry Air Systems, Inc.
Description: The Floor Sentry Quad Fume Extractor provides a cost-effective air filtration choice for multiple operators in limited workspace environments. A powerful fan draws in airborne contaminants through four self-supportive flex arms into the filtration chamber. The high-quality filtration removes
- Airflow: 350 SCFM
- Minimum Particle Size Filtered: 0.3 to 0.5 µm
- Features: HEPA / ULPA Filters
-
Supplier: Sentry Air Systems, Inc.
Description: flex arm provides a 62.5” swivel radius. This system utilizes a powerful fan to draw in most of the fumes and particulate into the filtration chamber before releasing the filtered air into the surrounding room. Depending on the application, several filter combinations can be utilized.
- Airflow: 100 SCFM
- Minimum Particle Size Filtered: 0.3 µm
- Features: HEPA / ULPA Filters
-
Supplier: Sentry Air Systems, Inc.
Description: The Model 300 Winged Sentry provides benchtop fume extraction with a unique design and horizontal airflow pattern. The wing flaps can be infinitely adjusted to assist in directing contaminated air towards the unit’s inlet, into the filter chamber, and away from the operator working between
- Airflow: 350 SCFM
- Minimum Particle Size Filtered: 0.3 to 0.5 µm
- Features: HEPA / ULPA Filters
-
Supplier: Sentry Air Systems, Inc.
Description: flex arm provides a 62.5” swivel radius. This system utilizes a powerful fan to draw in most of the fumes and particulate into the filtration chamber before releasing the filtered air into the surrounding room. Depending on the application, several filter combinations can be utilized.
- Airflow: 950 SCFM
- Minimum Particle Size Filtered: 0.12 to 0.5 µm
- Features: HEPA / ULPA Filters
-
Supplier: CITGO Petroleum Corporation
Description: CITGO SUPERGARD Sea and Snow 2-Cycle Engine Oil is a synthetic blend, low smoke oil designed for use in high performance air- or liquid-cooled two-stroke engines of Personal Water Craft (PWC) and Snowmobiles. SUPERGARD Sea and Snow 2-Cycle Engine Oil is engineered for lower smoke and
- Industry Applications: Combustion Engines / Motor Oil
- Type: Fluid / Oil
- Features: Lubricant
- Composition / Chemistry: Synthetic / Semi-synthetic
-
Supplier: Terra Universal, Inc.
Description: Low-Energy Swing Door Operators are customizable systems that can be installed on pass-through chambers and lab cleanroom doors. Space-saving systems feature an electromechanical drive and an advanced microprocessor system. Twelve programmable options, smoke ventilation system
- Width: 36 to 72 inch
- Features: Automatic, Window(s)
- Type: Cleanroom Doors
- Material: Glass, Plastic
Find Suppliers by Category Top
Featured Products Top
-
ESPEC AND ANDRITZ BITRODE BROUGHT ADVANCED BATTERY CHARGE-DISCHARGE TESTING TO LIFE AT THE BATTERY SHOW NORTH AMERICA 2025 ESPEC North America Inc, the global leader in environmental testing chambers, did a live demonstration of its next-generation Advanced Battery Chamber (ADBC (read more)
Browse Datasheets for ESPEC North America Inc | Qualmark Products and Services -
applications, which we will discuss below, include the following: Abrasion resistant Chemical resistant Flexible High heat resistance High strength Low smoke emissions Will not burn or smolder (read more)
Browse Cordage, Rope, and Webbing Datasheets for Mid-Mountain Materials, Inc. -
several challenges due to the harsh operating conditions and the characteristics of biomass combustion. Some of these challenges include: High Temperatures: Biomass boilers operate at high temperatures, especially in the combustion chamber and heat exchange surfaces. Traditional (read more)
Browse Thermal Imagers Datasheets for LAND
More Information Top
-
Smoke Detector Response and the Use of Antistatic Materials: An Empirical Study
It was found that these differences were due to the fact that the smoke chamber of one smoke detector design used an antistatic ABS and the other smoke detector design used a non-antistatic ABS for its smoke chamber.
-
An attachment for use with the NBS smoke density chamber for measurement of smoke obscuration at different orientations
In this work, the smoke generated by 12 materials was measured in the smoke chamber in the normal way and by using a proposed attachment, with a dual‐burner system which can be oriented both horizontally and vertically.
-
Method for Measuring Smoke from Burning Materials
Volume of smoke chamber Attenuation coefficient in Bouguer's law .
-
LDRD report: Smoke effects on electrical equipment
Relative humidity in two locations in the smoke chamber .....................31 Figure 24.
-
PROCEEDINGS OF CONFERENCE ON INHALATION CARCINOGENESIS HELD OCTOBER 8--11, 1969, GATLINBURG, TENN. AEC Symposium Series 18.
Fig. 6 - Smoking chamber as used by the Leuchtenbergers.
Indicates content that may require registration and/or purchase.