Pipeline Risk Management Manual: Ideas, Techniques, and Resources, Third Edition

| Inspection or test type | Purpose | Attributes |
|---|---|---|
| Pressure testing (hydrostatic pressure testing) | Commonly used as a pre-service integrity validation of the pipe and components by pressurizing to a level above the intended operating pressure. | A regulatory requirement for new pipe sections, to uprate existing pipe sections, and conversion from vapor to liquid service. |
| Destructively detects defects so they do not subsequently fail while in service. | Done by sectioning line according to terrain elevations. One or more valve sections can be included within test segment. | |
| Allows the establishment of the real minimum strength of the pipeline and components, as opposed to the mill tensile test, which is based on a sample of pipe. | Requirements and procedures defined in regulations and industry standards. | |
| Hydrotesting service is usually provided by a specialty contractor overseen by operating company staff. | ||
| Cathodic protection (CP) inspections and surveys | Determines the adequacy of cathodic protection voltages and currents for protecting the pipeline against corrosion and to detect areas of potentially defective coating. | Rectifier inspections are done to ensure that the rectifiers are in service and providing the required impressed current for cathodic protection. |
| Station tests or surveys are done to measure CP voltages at test station locations. This also includes readings taken at pipe casings under roads and railway crossings. | ||
| Various forms of close interval surveys (CIS) are taken at intervals of 2 to 10 ft along a pipeline to provide a profile... |