Fill out as many options as you want. Click "Run Search Filter" at any time.

Display Technology:

Standard Display Colors:

Number of Segments:

Bar Scale Length:

Center Scale Zero?

End Scale Zero?

Mounting Orientation:

Analog Input Channels:

Voltage Range:

Current Range:

Frequency Range:

Analog Input Type:

Output Type:

Response Time:

Accuracy:

± % of Full Scale

Width:

Height:

Depth:

Features:

Operating Temperature:

Help with Digital Bargraphs specifications:

Display
   Display Technology       
   Your choices are...         
   LED       A panel meter where the segments are represented by light emitting diodes (LEDs). 
   LCD       A panel meter where the segments are represented by dark areas in a liquid crystal display. 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
   Standard Display Colors      Bi-color LED's are made using red and green LED's in the same package. Most indoor programmable LED displays today use either all red LED's or they use red and green LED's. To a lesser extent all amber is sometime selected. It is possible to create 256 or more shades of color from red to green using only red and green bi-color LED's. Blue LED's are the most expensive and have the highest brightness. Adding blue LED's to the red and green can give you over 1.7 million shades of color.
   Your choices are...         
   Amber       The characters are amber in color.  Amber is a deep yellow color. 
   Aqua       The characters are aqua in color. 
   Blue       The characters are blue in color.  Common wavelength of 450 nm. 
   Green       The characters are amber in color.  Common wavelengths of 565 or 555 nm. 
   Orange       The characters are orange in color.  Common wavelength of 610 nm. 
   Red       The characters are red in color.  Common Wavelength of 660 or 630 nm. 
   Red (High Intensity)       The characters are high intensity red in color.  Common wavelength of 700 nm. 
   Yellow       The characters are yellow in color.  Common wavelength of 590 nm. 
   Multicolor       The panel meter is capable of displaying characters in multiple colors. 
   Other       Other unlisted color. 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
   Number of Segments       The number of bar graph segments. 
   Search Logic:      All matching products will have a value greater than or equal to the specified value.
   Bar Scale Length:       The total length of all bar graph segments. 
   Search Logic:      All matching products will have a value greater than or equal to the specified value.
   Center Scale Zero       The zero point is in the middle of the bargraph with negative values displayed on the left and positive values on the right. 
   Search Logic:      "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice.
   End Scale Zero       Zero is at the end of the bargraph. 
   Search Logic:      "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice.
   Mounting Orientation:       
   Your choices are...         
   Vertical Mount       The bar graph is in a vertical position. 
   Horizontal Mount       The bar graph is in a horizontal position. 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
Back to Top
Inputs
   Analog Input Channels:       Number of all analog input channels. This includes both general & specific types. 
   Search Logic:      All matching products will have a value greater than or equal to the specified value.
   Voltage Range       The range of voltages the meter is capable of measuring. 
   Search Logic:      User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria.
   Current Range       The range of currents the meter is capable of measuring. 
   Search Logic:      User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria.
   Frequency Range       The range of frequencies the meter is capable of measuring. 
   Search Logic:      User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria.
   Analog Input Type       
   Your choices are...         
   AC Voltage       Input is received as a measurable form of AC voltage. 
   DC Voltage       Input is received as a measurable form of DC voltage. 
   AC Current       The input is designed to receive AC current. 
   DC Current       The input is designed to receive DC current. 
   Frequency       The input is designed to receive a frequency or pulse. 
   Single Phase AC Power       Input is received as an adjustable range of single phase AC current, voltage and/or frequency. 
   Three Phase AC Power       Input is received as an adjustable range of three phase AC current, voltage and/or frequency. 
   DC Power       Input is received as an adjustable range of DC current, voltage and/or frequency. 
   Strain Gauge       A strain gauge is a sensing device, attached along its entire length to a surface so that its resistance will change as the surface is deformed. Strain gages are typically used as elements in a Wheatstone bridge circuit, which is used to make the measurement. 
   Resistance       Piezoresistive sensors are based on semiconductor technology. The resistance changes because of alterations in the length and width (as with strain gauges) as well as a shift of electrical charges within the resistor. 
   Temperature       Thermocouple (TC), RTD or thermistor input accepted. 
   Other       Other unlisted type of input. 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
Back to Top
Outputs
   Output Type       
   Your choices are...         
   Analog       Analog outputs are used in applications that require digitally controlled output voltages usually within the range of +/-10 V or less, and at current levels below 10 mA. The heart of an analog output channel is a digital-to-analog converter (DAC), which converts a digital code into a voltage level. The output of the DAC is then processed or conditioned to produce the required output signal characteristics. 
   Parallel       A channel capable of transferring more than one bit at a simultaneously. 
   Serial       A port, or interface, that can be used for serial communication, in which only one bit is transferred at a time. 
   Relay       One of the most common types of outputs available is the relay output. A relay can be used with both AC and DC loads. 
   Other       Other unlisted type of output. 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
Back to Top
Performance
   Response Time       The amount of time required to display the input. 
   Search Logic:      All matching products will have a value less than or equal to the specified value.
   Accuracy       The accuracy of the displayed value. 
   Search Logic:      All matching products will have a value less than or equal to the specified value.
Back to Top
Dimensions
   Width       The width of the meter. 
   Search Logic:      User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria.
   Height       The height of the meter. 
   Search Logic:      User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria.
   Depth       The depth of the meter. 
   Search Logic:      User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria.
Back to Top
Features
   Features       
   Your choices are...         
   Adjustable Display       The meter can be adjusted to show different displays. 
   Alarms       The meter has alarms to indicate when limits or set points are reached. 
   Displays Digits       The meter also has a digital display. 
   Intrinsically Safe       At facilities where there are flammable or explosive materials, operating at low energy can prevent electrical devices from creating arcs, sparks, or heat (during normal or fault conditions) that could ignite the explosive substance. Such a system is termed "intrinsically safe." 
   On / Off Control       The meter has the ability to turn the input sensor or transducer on or off. 
   Also a Scanner       Meter has the ability to scan or multiplex. 
   Set Point Options       Ability to set points in the display that the data must be displayed between. 
   Signal Conditioning Ability       Meter has the ability to condition the signal upon receiving it. 
   Totalizer       A totalizer counts and records the data for a set or indefinite period of time. 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
Back to Top
Environment
   Operating Temperature:       This is the full required range of ambient operating temperature. 
   Search Logic:      User may specify either, both, or neither of the limits in a "From - To" range; when both are specified, matching products will cover entire range. Products returned as matches will meet all specified criteria.
Back to Top
Product Announcements
Chief Enterprises LLC
Federal Signal Corporation - Industrial Signaling and Systems