Total Organic Carbon Total Organic Carbon (TOC) Analyzers

13 Results
Laboratory TOC Analyzer -- QBD1200
from Hach

Take the pain out of TOC analysis and lower your total cost of ownership Need to tust TOC results? • The QBD1200 has 95% less carryover. Inconsistent results? • Trust 2% standard deviation at 50 mg/L and 3% at 100 µg/L. Want to lower your Total Cost?. • Stop wasting money. Save... [See More]

  • Analytes Measured: Total Organic Carbon
  • Detector Type: NDIR
  • Analysis Method: UV Persulfate
  • Sample Introduction: On-Line
TOC-V Series - Total Organic Carbon Analyzer -- TOC-VWS
from Shimadzu Scientific Instruments, Inc.

TOC-VWS: Wet oxidation/NDIR method, standalone. TOC-VWP: Wet oxidation/NDIR method, PC-controlled. Shimadzu is proud to introduce the first Heated-UV-Persulfate system that utilizes three oxidation methods for maximum oxidation efficiency. This method ensures rapid, efficient breakdown of... [See More]

  • Analytes Measured: Total Organic Carbon; Total Carbon; Total Inorganic Carbon; Non-Purgeable Organic Carbon
  • Sample Introduction: Syringe
  • Analysis Method: UV Persulfate; Nondispersive Infrared (NDIR)
  • Measurement Range: 0.5000 to 3500
On-line TOC Analyzer 6000TOCi
from Mettler-Toledo Technologies GmbH

Real-time Total Organic Carbon Control. The 6000TOCi on-line TOC sensor delivers reliable data to demonstrate compliance in Pharmaceutical water systems. The high performance sensor provides real-time data, internal diagnostics and reporting to easily meet audit requirements. Real-Time Transparency... [See More]

  • Analytes Measured: Total Organic Carbon
  • Sample Introduction: On-Line
  • Analysis Method: UV Fluorescence
  • Measurement Range: 5.00E-5 to 2
Automatic Benchtop Analyzer -- StarTOC
from TOC Systems, Inc.

bull; Five Oxidation Methods in One Analyzer. • 103 Sample Stations & 1 Wash Station. • Dual NDIRs. • Widest Dynamic Range. • Ease of operation with familiar Windows Software. • Reliability Through Simplicity. Unmatched Versatility & Reliability. The StarTOC... [See More]

  • Analytes Measured: Total Organic Carbon; Total Carbon; Total Inorganic Carbon
  • Detector Type: NDIR
  • Analysis Method: Combustion; UV Persulfate; Ozone
  • Measurement Range: 50000
REAL TOC PROBE -- OA-X SERIES
from Real Tech, Inc.

TOC PROBE. Real Tech ’s robust TOC submersible probe provides affordable real-time measurement of total organic carbon (TOC) and/or dissolved organic carbon (DOC) in water or wastewater. The TOC probe utilizes patent-pending technology to provide superior measurement performance across... [See More]

  • Analytes Measured: Total Organic Carbon
  • Average Analysis Time: 10
  • Measurement Range: 0.0 to 6000
  • General Features: Built-in or Self Calibration
Total Organic Carbon Analyzers -- TOC-4200
from Shimadzu Scientific Instruments, Inc.

Highly advanced on-line TOC Analyzer excels in a wide range of applications. The TOC-4200 is a high-performance on-line TOC analyzer, based on the proven 680 °C Catalyst-aided Combustion Technology. This established technology is featured in a large installed base of Shimadzu Total Organic... [See More]

  • Analytes Measured: Total Organic Carbon; Non-Purgeable Organic Carbon; TN (Total Nitrogen)
  • Sample Introduction: Syringe
  • Analysis Method: Combustion; Nondispersive Infrared (NDIR)
  • Measurement Range: 0.0 to 20000
Total Organic Carbon Sensor 4000TOCe
from Mettler-Toledo Technologies GmbH

On-Line TOC Sensor with Flow Control. The 4000TOCe on-line TOC sensor with flow control provides continuous, fast and reliable monitoring of TOC levels from post RO waters to point-of-use. Continuous Flow to Detect Rapid Changes. Allows quick reaction to Total Organic Carbon excursions and better... [See More]

  • Analytes Measured: Total Organic Carbon
  • Sample Introduction: On-Line
  • Analysis Method: UV Fluorescence
  • Measurement Range: 5.00E-5 to 1
Dual Method Analyzer -- StarTOC
from TOC Systems, Inc.

StarTOC Dual Method Ozone / Hydroxyl Radicals + UV / Heated Persulfate offers the highest oxidation potential to assure complete TOC recovery in the most difficult of samples. This Dual Method satisfies the most challenging of applications and is the clear choice of performance-oriented users, who... [See More]

  • Analytes Measured: Total Organic Carbon
  • Detector Type: NDIR
  • Analysis Method: UV Persulfate; Ozone
  • Sample Introduction: On-Line
Real TOC Sensor – OL Series
from Real Tech, Inc.

Real Tech ’s bypass TOC sensor offers a practical and affordable real-time monitoring solution for many organics monitoring applications. The sensor provides rapid, real-time measurement of TOC without the use of reagents. Benefiting from Real Tech ’s innovative Split-Sense Pro... [See More]

  • Analytes Measured: Total Organic Carbon
  • Carrier Gas Flow: 1000
  • Analysis Method: Split-Sense Pro
  • Average Analysis Time: 0.5000
Total Organic Carbon Analyzers -- TOC-L Series
from Shimadzu Scientific Instruments, Inc.

The TOC-L series of TOC analyzers adopts the 680 °C combustion catalytic oxidation method, which was developed by Shimadzu and is now used worldwide.  While providing an ultra wide range of 4 μg/L to 30,000 mg/L, these analyzers boast a detection limit of 4 μg/L through coordination... [See More]

  • Analytes Measured: Total Organic Carbon; Total Carbon; Non-Purgeable Organic Carbon; Purgeable Organic Carbon; TN (Total Nitrogen)
  • Sample Introduction: Auto-Sampler
  • Analysis Method: Combustion; Nondispersive Infrared (NDIR)
  • Measurement Range: 0.0 to 35000
ON-LINE Combustion Analyzer -- StarTOC
from TOC Systems, Inc.

Description. Star Instruments, Inc. uniquely offers all methods of TOC analysis and recommends High Temperature Combustion as the method of choice for many applications. The reactor temperature may be adjusted by the operator & configured for catalytic or non-catalytic oxidation. The analyzer... [See More]

  • Analytes Measured: Total Organic Carbon; Non-Purgeable Organic Carbon
  • Detector Type: NDIR
  • Analysis Method: Combustion
  • Sample Introduction: Auto-Sampler
REAL TOC/DOC FIELD METER -- OP SERIES
from Real Tech, Inc.

The portable TOC/DOC Field Meter from Real Tech provides simple and affordable testing of organic matter in water or wastewater output as total organic carbon (TOC) or dissolved organic carbon (DOC). Operation is straight forward with accurate and repeatable results obtained in seconds. An optional... [See More]

  • Analytes Measured: Total Organic Carbon; DOC
  • Measurement Range: 0.0 to 2500
  • Analysis Method: Split-Sense Pro
  • Display Options: Digital
Semi-Automatic Bench Top TOC Analyzer
from TOC Systems, Inc.

StarTOC Semi-Automatic Bench Top TOC is a low cost, accurate analyzer which utilizes components and software from the StarTOC Family of computer-controlled automated TOCs. Since operation and maintenance are extremely simple, it may be the analyzer of choice when less than 20 samples per day are to... [See More]

  • Analytes Measured: Total Organic Carbon; Total Carbon; Total Inorganic Carbon
  • Detector Type: NDIR
  • Analysis Method: Combustion (optional feature); UV Persulfate
  • Sample Introduction: Syringe