115 / 60 / 1 Chillers (industrial)

Description

115 / 60 / 1 industrial chillers are designed to remove heat from a processed fluid, maintaining a stable temperature for various industrial processes. These chillers are integral in ensuring that machinery and instruments operate within their optimal temperature ranges, thereby enhancing performance and longevity.

Working Principle

Industrial chillers operate by circulating a coolant through a closed or open loop system. In a closed loop system, the chiller recirculates a clean coolant at a constant temperature and pressure, which stabilizes the temperature of water-cooled machines and instruments. In an open loop system, the chiller controls the temperature of a liquid in an open tank by continuously recirculating it. The liquid is drawn from the tank, pumped through the chiller, and returned to the tank. An adjustable thermostat senses the liquid temperature, cycling the chiller to maintain a constant temperature. This process is crucial for maintaining precise temperature control, which is essential for many industrial applications.

Applications

Industrial chillers are used in a variety of applications, including large commercial and industrial systems. For example, the air conditioning system in Dubai’s Burj Khalifa utilizes a vast network of chilled water piping to produce the cooling equivalent of 10,000 tons of melting ice daily. These systems are ideal for buildings requiring individual cooling for each room, ensuring efficient temperature management across large spaces.

Advantages over other Chillers (industrial)

One of the key advantages of 115 / 60 / 1 chillers is their ability to provide precise temperature control, which is critical for maintaining the stability and reproducibility of water-cooled machines and instruments. Additionally, these chillers can be configured in various ways, such as air-cooled or water-cooled condensing, and can be customized to meet specific industrial needs, offering flexibility and adaptability in different environments.

Limitations

While industrial chillers offer significant benefits, they also have limitations. For instance, the complexity of large chilled water systems can lead to increased maintenance requirements and potential for system failures if not properly managed. Additionally, the initial cost of installation and the ongoing operating expenses can be substantial, particularly for large-scale systems.

Considerations

When considering the implementation of 115 / 60 / 1 chillers, it is important to evaluate the initial costs, which can be high due to the complexity and scale of the systems. Operating expenses should also be considered, as they can vary depending on the system's efficiency and the specific application. Durability and accuracy are critical factors, as these chillers must maintain precise temperature control over long periods. Finally, replacement and maintenance costs should be factored into the decision-making process, as regular maintenance is essential to ensure the system's longevity and reliability.

8 Results
Cooling Systems -- Water-To-Air Heat Exchangers
from Ambrell Induction Heating Solutions

This water to water heat exchanger isolates the clean water required by the induction system from the plant cooling water. The electromagnetic field generated by an induction coil will interact with dissolved minerals (especially iron) in the cooling water, causing them to come out of solution in... [See More]

  • Power Source: 115/60/1; 230/50/1
  • Cooling Capacity: 1.6
  • Application: Industrial
  • Flow: 1.1
Standard Recirculating Chillers
from Boyd

Recirculating Chillers are designed for precise temperature control or cooling below ambient temperatures. Compressor-based Recirculating Chillers offer outstanding performance and high reliability as well as quiet operation and ease-of-use. Components inside the chiller have been... [See More]

  • Power Source: 115/60/1; 230/50/1; 208-230/60/1; 208-230/60/3; 380/50/3; 460/60/3
  • Cooling Capacity: 0.6 to 11.0
  • Application: Industrial; Scientific; Laser; Medical; Other; Semiconductor Processing, 3D Printers
  • Flow: 1 to 12
ThermoChill I Recirculating Chiller
from Thermo Fisher Scientific - Thermo Scientific Baths, Circulators & Chillers

Experience reliable liquid temperature control, with cooling capacity up to 700W/2391 BTU using Thermo Scientific ™ ThermoChill I Recirculating Chillers. The ThermoChill series of chillers is a compact line of refrigerated recirculators ranging in cooling capacities from 600 to 2000 watts. [See More]

  • Power Source: 115/60/1; 230/50/1
  • Cooling Capacity: 0.6 to 0.7
  • Application: Industrial; Scientific; Laser; Other; Analytical, Automotive, Biotech, Packaging, Printing, University
  • Discharge Temperature: 14 to 86
Recirculating Chiller -- 4900-110
from Qsonica, LLC

Recirculating Chiller. Keep your samples cool during sonication. Sonication generates heat which may be detrimental to some applications. This compact and powerful chiller easily automates the cooling process. It keeps samples cool while occupying very little bench space. Controlling temperature by... [See More]

  • Power Source: 115/60/1; 230/50/1; 208-230/60/1; Other; 85-265 VAC, 50/60 Hz
  • Discharge Temperature: 35.6 to 113
  • Application: Industrial; Process
  • Dimensions: 7.5"h x 5"w x 7"d
Compact Chiller, CC Series -- CC 6101
from Pfannenberg

Each chiller model includes the pump, tank, refrigeration system and controls required for simple installation and reliable, efficient operation. Model sizes ranging from a 1/2 Ton up to 30 Tons insure that the proper capacity is available for most applications. Ethylene & propylene glycol... [See More]

  • Power Source: 115/60/1; 208-230/60/1
  • Cooling Capacity: 1.2
  • Application: Industrial; HVAC
  • Discharge Temperature: 35 to 70
Recirculating Chiller -- BRC-03
from BEING Scientific Inc.

Performance and Features. Designed so that test results are in line with international standards DIN 12880. PID temperature controller with LCD screen provides accurate and reliable temperature control. Automatic calibration function, be able to adapt to a variety of laboratory environments. [See More]

  • Power Source: 115/60/1
  • Cooling Capacity: 0.1 to 0.6
  • Application: Industrial
  • Flow: 1.58
Maximum Series Air-Cooled Portable Water Chiller -- M1-.25A
from Advantage Engineering, Inc.

Portable chillers are refrigeration systems used to cool fluids to support industrial process cooling requirements. Portable chillers can be moved between use points as needed and include an internal reservoir and pumping system. Air-Cooled portable chillers used indoor ambient air to cool the... [See More]

  • Power Source: 115/60/1
  • Cooling Capacity: 1.0
  • Application: Industrial; Process
  • Discharge Temperature: 20 to 80
Recirculating Chiller -- BRC-05
from BEING Scientific Inc.

Performance and Features. Designed so that test results are in line with international standards DIN 12880. PID temperature controller with LCD screen provides accurate and reliable temperature control. Automatic calibration function, be able to adapt to a variety of laboratory environments. [See More]

  • Power Source: 115/60/1
  • Cooling Capacity: 0.2 to 0.9
  • Application: Industrial
  • Flow: 1.58