Terminal Block Thermocouple Temperature Transmitters
from United Electric Controls Company
Thermowell and protection tube manufacturer , United Electric Controls creates and designs custom thermowells and protection tubes. UE offers a complete line of sold-bore thermowells and manufactured protection tubes in a variety of materials and constructions. Serving customers worldwide, our... [See More]
- Connection: Terminal Block
- Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
- Thermocouple: E (optional feature); J (optional feature); K (optional feature); T (optional feature); B (optional feature); S (optional feature); R (optional feature)
- Output: Analog Current (Typical 4-20 mA)
from ABB Measurement & Analytics
The field-mount temperature transmitter can be configured via FDT / DTM in DAT200 (Asset Vision Basic) or any standard FTD tool via EDD or local HMI (optional). The Field Information Manager (FIM) is also supported via FDI technology. For PROFIBUS the configuration is possible via GST-file, EDD or... [See More]
- Connection: Terminal Block
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Resistance Inputs
- Thermocouple: E; J; K; N; T; B; S; R
- Sensed Temperature: -328 to 1562
from Dataforth Corporation
Each DSCT37 non-linearized thermocouple input transmitter provides a single channel of thermocouple input which is filtered, isolated, amplified, and converted to a process current output. Signal filtering is accomplished with a five-pole filter, which provides 85dB of normal-mode rejection at 60Hz... [See More]
- Connection: Terminal Block
- Sensed Temperature: -148 to 1400
- Thermocouple: J
- Mounting Options: Modular
from ABB Measurement & Analytics
The TTH300 is provided for the highest requirements of temperature measurement with two sensor inputs. This supports sensor redundancy and sensor drift monitoring. The transmitter follows NAMUR Recommendations such as NE 89 and NE 107. As an option, an LCD indicator with operating buttons can be... [See More]
- Connection: Terminal Block
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Resistance Inputs
- Thermocouple: E; J; K; N; T; B; S; R
- Sensed Temperature: -328 to 1562
from ABB Measurement & Analytics
The field-mount temperature transmitter TTF200 is provided for all HART standard applications in temperature measurement with one sensor. The transmitter supports the same functionality as the TTF300, but without sensor redundancy and sensor drift monitoring. It can be configured with ABB-tools such... [See More]
- Connection: Terminal Block
- Mounting Options: Field Mounted
- Thermocouple: E; J; K; N; T; B; S; R
- Output: Analog Current (Typical 4-20 mA)
from ABB Measurement & Analytics
The WirelessHART technology features a multitude of new functions and enhanced diagnostic information. Unique driver-independent configuration of the transmitter via push buttons and LCD display. [See More]
- Connection: Terminal Block
- Mounting Options: Field Mounted
- Thermocouple: E; J; K; N; T; B; S; R
- Local Interface: Digital Front Panel
from Status Instruments, Inc.
The SEM310 is a field mount temperature transmitter designed to replace the terminal block in a sensor head. It is fully encapsulated to ensure environmental integrity. Although small in size it out performs other larger and more expensive transmitters. Also available in DIN rail mount format... [See More]
- Connection: Terminal Block; Lead Wires
- Sensed Temperature: -328 to 3200
- Thermocouple: E; J; K; N; S; R
- Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style); DIN Rail Mounting (optional feature)
from Acromag, Inc.
Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt ( ±100mV DC), 0 to 500 ohms input. 0 to 20mA DC, 0 to 10V DC output. Mechanical relay (25V @ 5A) alarm. 10-36V DC power. Software configured. Performs linearization, square root extraction, and optional limit alarm functions. [See More]
- Connection: Terminal Block; Lead Wires; Screw Clamps or Lugs
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs
- Thermocouple: E; J; K; N; T; B; S; R
- Sensed Temperature: -382 to 1562
from Acromag, Inc.
DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT233 model is a dual two-wire transmitter that isolates and converts millivolt or thermocouple sensor inputs to proportional 4-20mA control signals. Power is received from the output loop... [See More]
- Connection: Terminal Block; Lead Wires; Screw Clamps or Lugs
- Other Input: Accepts Generic Analog Voltage Inputs
- Thermocouple: E; J; K; N; T; B; S; R
- Mounting Options: DIN Rail Mounting
from Acromag, Inc.
100 ohm Pt, 120 ohm Ni, 10 ohm Cu (selectable type) input. 4 to 20mA DC output. 12-50V DC from output loop power. DIP-switch configuration, push-button calibration. These units accept universal RTD or resistance input signals and output proportional DC current signals. The output can also be... [See More]
- Connection: Terminal Block
- Other Input: Accepts Generic Analog Voltage Inputs
- Thermocouple: E; J; K; N; T; B; S; R
- Sensed Temperature: -382 to 3308
from Acromag, Inc.
2 channels, ±625mV, 0-10V DC (selectable ranges) input. 4 to 20mA DC output. 12-50V DC power from output loop. Dual-channel transmitter with push-button calibration. These units accept DC voltage input signals, provide isolation, and output proportional DC current signals. With two... [See More]
- Connection: Terminal Block; Lead Wires; Screw Clamps or Lugs
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs
- Thermocouple: T
- Mounting Options: DIN Rail Mounting
from Acromag, Inc.
4 to 20mA DC input. 4 to 20mA DC output. 12-50V DC power from output loop. Low cost isolator. These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels. For... [See More]
- Connection: Terminal Block; Lead Wires; Screw Clamps or Lugs
- Other Input: Accepts Generic Analog Current Inputs
- Thermocouple: T
- Mounting Options: DIN Rail Mounting
from Acromag, Inc.
plusmn;100V DC, 0 to 100mA DC, 0 to 20A AC (with optional sensor) input. 0 to 20mA, 0 to 10V DC output. 10-36V DC power. Universal DC I/O transmitters with auto-configuration and self-ranging capabilities. These units receive DC current or voltage input signals, provide isolation, and output... [See More]
- Connection: Terminal Block; Lead Wires; Screw Clamps or Lugs
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs
- Thermocouple: T
- Mounting Options: DIN Rail Mounting
from Acromag, Inc.
TC (types J, K T, R, S, E, B, N), ±1V DC, selectable range/type input. 4 to 20mA DC output. 12-50V DC from output loop power. DIP-switch configuration, signal linearizer, push-button calibration. These units accept universal thermocouple and millivolt input signals, provide isolation, and... [See More]
- Connection: Terminal Block; Lead Wires; Screw Clamps or Lugs
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs
- Thermocouple: E; J; K; N; T; B; S; R
- Mounting Options: DIN Rail Mounting