DIN Rail Mounting Thermocouple Temperature Transmitters

22 Results
2-Wire HART® Transmitter Din Rail Universal (ATEX/CSA/FM) -- 6335D
from Conax Technologies

RTD, TC, Ohm, or mV Input. Extremely High Measurement Accuracy. HART ® Communication. Complies with European ATEX, and CSA/FM Requirements for Hazardous Location Installation. 1- or 2-Channel Version. Application: Linearized temperature measurement with Pt 100...Pt 1000, Ni100...Ni1000, or TC... [See More]

  • Mounting Options: DIN Rail Mounting
  • Other Input: Accepts Generic Resistance Inputs
  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Sensed Temperature: -328 to 4172
Rail-Mount Temperature Transmitter -- TTR200
from ABB Measurement & Analytics

The TTR200 is a rail-mount version of the TTH200 transmitter with the addition of two indicator LEDs. A green LED indicates that the transmitter is powered. A red LED would indicate a fault in either the unit or the sensor. TTR200 units can be placed in cabinet racks. It can be configured with... [See More]

  • Mounting Options: DIN Rail Mounting
  • Output: Analog Current (Typical 4-20 mA)
  • Thermocouple: E; J; K; N; T; B; S; R
  • Features: Intrinsically Safe
Configurable 2-Wire Temperature Transmitter, DIN Mount -- DSCP20
from Dataforth Corporation

Each DSCP20 2-wire transmitter is designed for measuring temperature using thermocouples or RTDs. The input type, measurement range, and other features are software configurable. A PC, the DSCX-887 and DSCX-416 interface cables, and the DSCX-895 configuration software are required to configure the... [See More]

  • Mounting Options: DIN Rail Mounting
  • Sensed Temperature: -328 to 3308
  • Thermocouple: E; J; K; N; T; B; S; R
  • Output: Analog Current (Typical 4-20 mA)
2-Wire Programmable Head Mount T/C Transmitter (ATEX) -- 5334B
from Conax Technologies

2-Wire Programmable Head Mount T/C Transmitter (ATEX) Model – 5334B. * TC or mV Input. * Extremely High Measurement Accuracy. * 1.5 kVAC Galvanic Isolation. * Programmable Sensor Error Value. * Complies with European ATEX Requirements for Hazardous Location Installation. Application: *... [See More]

  • Mounting Options: DIN Rail Mounting
  • Other Input: Accepts Generic Analog Voltage Inputs
  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Sensed Temperature: -328 to 4172
Thermocouple-to-DC Current/Voltage Converter with Relay Output -- DSCP62
from Dataforth Corporation

Each DSCP62 Thermocouple Converter provides a single channel of thermocouple input which is amplified, linearized and converted to a high-level current or voltage output. Thermocouple type, measurement range, filter, output type and range, and fault indication may be configured by dip-switch. An... [See More]

  • Mounting Options: DIN Rail Mounting
  • Output: Analog Current (Typical 4-20 mA); Analog Voltage
  • Thermocouple: E; J; K; N; T; B; S; R
  • Connection: Screw Clamps or Lugs
KS 816 Multi-Loop Multiple Transmitter & Temperature Controller
from West Control Solutions

The microprocessor-controlled KS 816 controller provides precise, low-cost multi-loop control of temperature and features an interface for bus or field-bus. The KS 816 can be used as a freely configurable field-bus transmitter with universal inputs for standard signals, thermocouples and Pt 100... [See More]

  • Mounting Options: DIN Rail Mounting
  • Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs; Accepts Generic Resistance Inputs
  • Thermocouple: E; J; K; N; T; S; R; W
  • Sensed Temperature: -328 to 4172
2-wire HART® Transmitter -- 6337A
from PR electronics

Application. Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100. HART ® communication and 4...20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors. Conversion of linear resistance to a standard... [See More]

  • Mounting Options: DIN Rail Mounting
  • Output: Analog Current (Typical 4-20 mA)
  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Connection: Screw Clamps or Lugs
DIN Rail 2-Wire Temperature Transmitter -- DRA-TCI-2/DRA-RTI-2
from OMEGA Engineering, Inc.

Models DRA-TCI-2 and DRA-RTI-2 are linearized temperature transmitters that produce a 4-20 mA process signal that is directly proportional to temperature. These transmitters have exceptionally high input to output common mode rejection (CMR), a high degree of filtering that eliminates false output... [See More]

  • Mounting Options: DIN Rail Mounting
  • Sensed Temperature: 32 to 3092
  • Thermocouple: E (optional feature); J (optional feature); K (optional feature); T (optional feature); B (optional feature); S (optional feature); R (optional feature)
  • Output: Analog Current (Typical 4-20 mA)
Temperature Transmitter Field Circuit -- 9182
from R. STAHL, Inc.

One unit for nearly all temperature sensors indivdually configurable. Intrinsically safe input [Ex ia] IIC. Signal duplication possible. Galvanic isolation between input, output, power supply and configuration interface. Open-circuit and short-circuit monitoring and messaging (can be switched off). [See More]

  • Mounting Options: DIN Rail Mounting
  • Sensed Temperature: -328 to 3213
  • Thermocouple: E; J; K; N; T; B; S; R
  • Output: Analog Current (Typical 4-20 mA)
Intelligent Temperature Transmitter, Universal Input, IntelliPack® 800T Series -- 801T-0500
from Acromag, Inc.

Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt ( ±100mV DC), 0 to 500 ohms input. 0 to 20mA DC, 0 to 10V DC output. Mechanical relay (25V @ 5A) alarm. 10-36V DC power. Software configured. Performs linearization, square root extraction, and optional limit alarm functions. [See More]

  • Mounting Options: DIN Rail Mounting
  • Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs
  • Thermocouple: E; J; K; N; T; B; S; R
  • Sensed Temperature: -382 to 1562
Thermocouple DIN Rail Transmitter -- SEM1605TC
from Status Instruments, Inc.

INTRODUCTION. It has been designed to accept most common thermocouple sensor inputs and provide the user with a standard two-wire 4 to 20mA output signal. Galvanic isolation is provided between input and output and all temperature ranges are linear to temperature. Designed for ease of use, our... [See More]

  • Mounting Options: DIN Rail Mounting
  • Sensed Temperature: -328 to 4172
  • Thermocouple: E; J; K; N; T; B; S; R
  • Output: Analog Current (Typical 4-20 mA)
7600D Temp Transmitter
from Ultra Energy

7600D Temp Transmitter, Industrial Temperature Transmitter, DIN Rail Mount, RTD, T/C, Ω, mV [See More]

  • Mounting Options: DIN Rail Mounting
  • Sensed Temperature: -328 to 1562
  • Thermocouple: E; J; K; N; T; B; S; R
  • Output: Analog Current (Typical 4-20 mA)
2-wire HART® Transmitter -- 6337D
from PR electronics

Application. Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100. HART ® communication and 4...20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors. Conversion of linear resistance to a standard... [See More]

  • Mounting Options: DIN Rail Mounting
  • Output: Analog Current (Typical 4-20 mA)
  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Connection: Screw Clamps or Lugs
DIN Rail Universal Smart Transmitter -- TXDIN101
from OMEGA Engineering, Inc.

The TXDIN101 is a computerized, PC programmable, galvanically isolated two-wire smart transmitter. The unit converts 13 types of thermocouple sensors; 12 types of RTD sensors, configured as 2-, 3- and 4-wires; potentiometer, resistor and millivolt inputs, single or differential into process current... [See More]

  • Mounting Options: DIN Rail Mounting
  • Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Resistance Inputs
  • Thermocouple: E; J; K; N; T; B; S; R
  • Sensed Temperature: -328 to 4208
Temperature Transmitter Field Circuit Non-Ex i 9182 -- 9182
from R. STAHL, Inc.

One unit for nearly all temperature sensors indivdually configurable. Signal duplication possible. Galvanic isolation between input, output, power supply and configuration interface. Open-circuit and short-circuit monitoring and messaging (can be switched off). Simple configuration with PC or... [See More]

  • Mounting Options: DIN Rail Mounting
  • Sensed Temperature: -328 to 3213
  • Thermocouple: E; J; K; N; T; B; S; R
  • Output: Analog Current (Typical 4-20 mA)
Thermocouple Millivolt Input Four-Wire Transmitter, TT230 Series -- TT333-0700
from Acromag, Inc.

Universal TC or millivolt input (TC type J, K, T, R, S, E, B, N or ±100mV input). Universal current/voltage output. 12-32V DC local/bus power. The TT333 model is a space-saving four-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional control... [See More]

  • Mounting Options: DIN Rail Mounting
  • Other Input: Accepts Generic Analog Voltage Inputs
  • Thermocouple: E; J (optional feature); K (optional feature); T (optional feature); S (optional feature); R (optional feature)
  • Output: Analog Current (Typical 4-20 mA)
9100D Temp Transmitter
from Ultra Energy

9100D Temp Transmitter, Industrial Temperature Transmitter, DIN Rail Mount, RTD, T/C, Ω, mV, HART [See More]

  • Mounting Options: DIN Rail Mounting
  • Sensed Temperature: -328 to 1562
  • Thermocouple: E; J; K; N; T; B; S; R
  • Output: Analog Current (Typical 4-20 mA)
2-wire Programmable Transmitter -- 5131A
from PR electronics

Advanced features. The 5131A transmitter can be configured with the software program PReset using a standard PC and the Loop Link communications unit. Application. Independent channel jumper selectable inputs for current/voltage or temperature. Current input programmable in range 0...100 mA and... [See More]

  • Mounting Options: DIN Rail Mounting
  • Output: Analog Current (Typical 4-20 mA)
  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Connection: Screw Clamps or Lugs
Dual DIN Rail Temperature Transmitter -- TXDIN70
from OMEGA Engineering, Inc.

It provides 2 channels of configurable inputs, and supports multiple voltage, RTD, thermocouple inputs with auto reference junction compensation. If parallel connected to an external precise resistance, it accepts current signal input. Each channel has its own digital filtering and can adjust its... [See More]

  • Mounting Options: DIN Rail Mounting
  • Sensed Temperature: -328 to 4172
  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Output: Analog Current (Typical 4-20 mA)
Thermocouple Millivolt Input Two-Wire Transmitter, TT230 Series -- TT233-0600
from Acromag, Inc.

Universal TC type J, K, T, R, S, E, B, N or ±100mV input. 4-20mA ouput (sink/source). 12-32 V DC loop/local power. The TT233 model is a space-saving two-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional 4-20mA control signal. Power is... [See More]

  • Mounting Options: DIN Rail Mounting
  • Other Input: Accepts Generic Analog Voltage Inputs
  • Thermocouple: E; J (optional feature); K (optional feature); T (optional feature); S (optional feature); R (optional feature)
  • Output: Analog Current (Typical 4-20 mA)
Profibus PA / Foundation Fieldbus Transmitter -- 6350A
from PR electronics

Application. Linearized temperature measurement with RTD or TC sensor. Difference, average or redundancy temperature measurement with RTD or TC sensor. Converts analog mA signals into digital values on the bus communication. Linear resistance, potentiometer and bipolar mV measurement. Technical... [See More]

  • Mounting Options: DIN Rail Mounting
  • Connection: Screw Clamps or Lugs
  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Supply Voltage: 9.0...32 VDC
Thermocouple/millivolt Input Two-wire Dual Transmitter -- DT233
from Acromag, Inc.

DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT233 model is a dual two-wire transmitter that isolates and converts millivolt or thermocouple sensor inputs to proportional 4-20mA control signals. Power is received from the output loop... [See More]

  • Mounting Options: DIN Rail Mounting
  • Other Input: Accepts Generic Analog Voltage Inputs
  • Thermocouple: E; J; K; N; T; B; S; R
  • Output: Analog Current (Typical 4-20 mA)