Analog Voltage Thermocouple Temperature Transmitters
from ABB Measurement & Analytics
The field-mount temperature transmitter can be configured via FDT / DTM in DAT200 (Asset Vision Basic) or any standard FTD tool via EDD or local HMI (optional). The Field Information Manager (FIM) is also supported via FDI technology. For PROFIBUS the configuration is possible via GST-file, EDD or... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Resistance Inputs
- Sensed Temperature: -328 to 1562
- Thermocouple: E; J; K; N; T; B; S; R
- Mounting Options: Field Mounted
from Conax Technologies
2-Wire Programmable Head Mount T/C Transmitter (ATEX) Model – 5334B. * TC or mV Input. * Extremely High Measurement Accuracy. * 1.5 kVAC Galvanic Isolation. * Programmable Sensor Error Value. * Complies with European ATEX Requirements for Hazardous Location Installation. Application: *... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs
- Sensed Temperature: -328 to 4172
- Thermocouple: E; J; K; N; T; B; S; R; W
- Mounting Options: DIN Rail Mounting
from Pyromation
Temperature transmitters make it possible to send a scalable (4 to 20) mA signal from a temperature sensor to a control device without investing in long, expensive runs of thermocouple or RTD wire. Pyromation carries programmable RTD and thermocouple temperature transmitters that can be mounted in... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Resistance Inputs
- Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style) (optional feature); DIN Rail Mounting (optional feature)
- Thermocouple: E; J; K; N; T; B; S; R
- Output: Analog Current (Typical 4-20 mA)
from ABB Measurement & Analytics
The TTH300 is provided for the highest requirements of temperature measurement with two sensor inputs. This supports sensor redundancy and sensor drift monitoring. The transmitter follows NAMUR Recommendations such as NE 89 and NE 107. As an option, an LCD indicator with operating buttons can be... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Resistance Inputs
- Sensed Temperature: -328 to 1562
- Thermocouple: E; J; K; N; T; B; S; R
- Output: Analog Current (Typical 4-20 mA)
from Conax Technologies
Programmable LED Indicator, 2 Relay, Front Key Programmable – Model 5714. * 4-Digit, 14-Segment LED Indicator. * Input for RTD, TC, mA, V, and Potentiometer. * Universal Supply Voltage. * Front Key Programmable. * Available with Optional 2 Relays and Analog Output. Application: * Display for... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs; Accepts Generic Resistance Inputs
- Sensed Temperature: -328 to 4172
- Thermocouple: E; J; K; N; T; B; S; R; W
- Mounting Options: Panel Mount, Rubber Gasket
from Conax Technologies
Programmable LED Indicator, 4 Relay, Front Key and PC Programmable Model 5715. * 4-Digit, 14-Segment LED Indicator. * Input for RTD, TC, mA, V, and Potentiometer. * 4 Relays with Optional Analog Output. * Universal Supply Voltage. * Programmable via Front Keypad or PC. Application: * Display for... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs; Accepts Generic Resistance Inputs
- Sensed Temperature: -328 to 4172
- Thermocouple: E; J; K; N; T; B; S; R; W
- Mounting Options: Panel Mount, Rubber Gasket
from OMEGA Engineering, Inc.
The TXDIN101 is a computerized, PC programmable, galvanically isolated two-wire smart transmitter. The unit converts 13 types of thermocouple sensors; 12 types of RTD sensors, configured as 2-, 3- and 4-wires; potentiometer, resistor and millivolt inputs, single or differential into process current... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Resistance Inputs
- Sensed Temperature: -328 to 4208
- Thermocouple: E; J; K; N; T; B; S; R
- Mounting Options: DIN Rail Mounting
from West Control Solutions
The microprocessor-controlled KS 816 controller provides precise, low-cost multi-loop control of temperature and features an interface for bus or field-bus. The KS 816 can be used as a freely configurable field-bus transmitter with universal inputs for standard signals, thermocouples and Pt 100... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs; Accepts Generic Resistance Inputs
- Sensed Temperature: -328 to 4172
- Thermocouple: E; J; K; N; T; S; R; W
- Mounting Options: DIN Rail Mounting
from Acromag, Inc.
Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt ( ±100mV DC), 0 to 500 ohms input. 0 to 20mA DC, 0 to 10V DC output. Mechanical relay (25V @ 5A) alarm. 10-36V DC power. Software configured. Performs linearization, square root extraction, and optional limit alarm functions. [See More]
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs
- Sensed Temperature: -382 to 1562
- Thermocouple: E; J; K; N; T; B; S; R
- Mounting Options: DIN Rail Mounting
from Azbil Corporation
These compact and lightweight smart temperature transmitters receive thermocouple input, RTD input, or mV input and transmit it as a 4 –20 mA DC or degital signal. They can be used with general-purpose signal cables, similar to other transmitters for flow or pressure measurement, eliminating... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs
- Output: Analog Current (Typical 4-20 mA)
- Thermocouple: E; J; K; N; T; B; S; R
- Local Interface: Digital Front Panel
from PR electronics
High Defintion Display. 0, 90, 180, & 270 degree position adjustments. Monitoring, programming and diagnostics view. Extensive diagnostics with flashing red or white backlight. Supports 7 languages. Local Operator Interface (LOI). 3 optical buttons; up, down and enter. Dynamically adaptive to... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Resistance Inputs
- Output: Analog Current (Typical 4-20 mA)
- Thermocouple: E; J; K; N; T; B; S; R; W
- Connection: Screw Clamps or Lugs
from OMEGA Engineering, Inc.
TX900 Series transmitters feature dip switch selection of input type and range. The following models are available: TX901 (non-isolated, accepts J, K,T, E, R or S thermocouples); TX903 (isolated, accepts J, K, T, E, R or S thermocouples; TX904 (non-isolated, accepts 100 ohm Pt RTD's 2- or 3- wire);... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs
- Sensed Temperature: 149 to 3193
- Thermocouple: E; J; K; T; S; R
- Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
from Acromag, Inc.
Universal TC or millivolt input (TC type J, K, T, R, S, E, B, N or ±100mV input). Universal current/voltage output. 12-32V DC local/bus power. The TT333 model is a space-saving four-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional control... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs
- Mounting Options: DIN Rail Mounting
- Thermocouple: E; J (optional feature); K (optional feature); T (optional feature); S (optional feature); R (optional feature)
- Output: Analog Current (Typical 4-20 mA)
from OMEGA Engineering, Inc.
The rugged high-performance, high power OMEGA wiSeries wireless transmitters featured on this page are compatible with the OMEGA zSeries & wiSeries system for Web-based monitoring of Analog Voltage and Current, Temperature, Humidity, and Barometric Pressure. The radio is a High Power IEEE... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs
- Sensed Temperature: -454 to 4208
- Thermocouple: E; J; K; N; T; B; S; R
- Output: Analog Current (Typical 4-20 mA) (optional feature); Analog Voltage (optional feature)
from Acromag, Inc.
Universal TC type J, K, T, R, S, E, B, N or ±100mV input. 4-20mA ouput (sink/source). 12-32 V DC loop/local power. The TT233 model is a space-saving two-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional 4-20mA control signal. Power is... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs
- Mounting Options: DIN Rail Mounting
- Thermocouple: E; J (optional feature); K (optional feature); T (optional feature); S (optional feature); R (optional feature)
- Output: Analog Current (Typical 4-20 mA)
from OMEGA Engineering, Inc.
Unmatched Electrical Performance. Two-wire Operation Power is obtained directly from the 4 to 20 mA loop, with no need for separate power input. This simplifies field wiring and eliminates the possibility of noise pickup from power lines. Isolation to 1500 V rms (2100 Vp). This exceptionally high... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs; Accepts Generic Resistance Inputs
- Sensed Temperature: -328 to 2322
- Thermocouple: E (optional feature); J (optional feature); K (optional feature); T (optional feature)
- Output: Analog Current (Typical 4-20 mA)
from Acromag, Inc.
DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT233 model is a dual two-wire transmitter that isolates and converts millivolt or thermocouple sensor inputs to proportional 4-20mA control signals. Power is received from the output loop... [See More]
- Other Input: Accepts Generic Analog Voltage Inputs
- Mounting Options: DIN Rail Mounting
- Thermocouple: E; J; K; N; T; B; S; R
- Output: Analog Current (Typical 4-20 mA)