J Thermocouple Temperature Transmitters

54 Results
Field Mounted Temperature Transmitter -- TTF300
from ABB Measurement & Analytics

The field-mount temperature transmitter can be configured via FDT / DTM in DAT200 (Asset Vision Basic) or any standard FTD tool via EDD or local HMI (optional). The Field Information Manager (FIM) is also supported via FDI technology. For PROFIBUS the configuration is possible via GST-file, EDD or... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Sensed Temperature: -328 to 1562
  • Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Resistance Inputs
  • Mounting Options: Field Mounted
Temperature Transmitters -- 3630222
from RS Components, Ltd.

RS PRO XQ-125-RS Temperature Transmitter [See More]

  • Thermocouple: J; K; T
Configurable 2-Wire Temperature Transmitter, DIN Mount -- DSCP20
from Dataforth Corporation

Each DSCP20 2-wire transmitter is designed for measuring temperature using thermocouples or RTDs. The input type, measurement range, and other features are software configurable. A PC, the DSCX-887 and DSCX-416 interface cables, and the DSCX-895 configuration software are required to configure the... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Mounting Options: DIN Rail Mounting
  • Sensed Temperature: -328 to 3308
  • Output: Analog Current (Typical 4-20 mA)
2-Wire HART® Transmitter Din Rail Universal (ATEX/CSA/FM) -- 6335D
from Conax Technologies

RTD, TC, Ohm, or mV Input. Extremely High Measurement Accuracy. HART ® Communication. Complies with European ATEX, and CSA/FM Requirements for Hazardous Location Installation. 1- or 2-Channel Version. Application: Linearized temperature measurement with Pt 100...Pt 1000, Ni100...Ni1000, or TC... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Sensed Temperature: -328 to 4172
  • Other Input: Accepts Generic Resistance Inputs
  • Mounting Options: DIN Rail Mounting
Programmable Temperature Transmitter
from Pyromation

Temperature transmitters make it possible to send a scalable (4 to 20) mA signal from a temperature sensor to a control device without investing in long, expensive runs of thermocouple or RTD wire. Pyromation carries programmable RTD and thermocouple temperature transmitters that can be mounted in... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style) (optional feature); DIN Rail Mounting (optional feature)
  • Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Resistance Inputs
  • Output: Analog Current (Typical 4-20 mA)
2-Wire Miniature Temperature Transmitters -- ETM1
from Tempco Electric Heater Corporation

The Tempco ETM Series of 2-wire transmitters are offered in isolated, non-isolated and high precision isolated versions. They are designed to fit in a standard aluminum, iron or plastic industrial connection head, DIN size B or larger [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Connection: Screw Clamps or Lugs
  • Output: Analog Current (Typical 4-20 mA)
  • Supply Voltage: 6.5 to 36 VDC
Field Mounted Temperature Transmitter -- TTH300
from ABB Measurement & Analytics

The TTH300 is provided for the highest requirements of temperature measurement with two sensor inputs. This supports sensor redundancy and sensor drift monitoring. The transmitter follows NAMUR Recommendations such as NE 89 and NE 107. As an option, an LCD indicator with operating buttons can be... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Sensed Temperature: -328 to 1562
  • Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Resistance Inputs
  • Output: Analog Current (Typical 4-20 mA)
Temperature Transmitters -- 3817132
from RS Components, Ltd.

RS PRO XQ-130-RS Temperature Transmitter [See More]

  • Thermocouple: E; J; K; N; T; S; R
Non-Linearized Thermocouple Input Transmitter -- DSCT37J-01
from Dataforth Corporation

Each DSCT37 non-linearized thermocouple input transmitter provides a single channel of thermocouple input which is filtered, isolated, amplified, and converted to a process current output. Signal filtering is accomplished with a five-pole filter, which provides 85dB of normal-mode rejection at 60Hz... [See More]

  • Thermocouple: J
  • Mounting Options: Modular
  • Sensed Temperature: -148 to 1400
  • Output: Analog Current (Typical 4-20 mA)
2-Wire Programmable Head Mount Universal Transmitter -- 5331A
from Conax Technologies

RTD, TC, Ohm, or mV Input. Extremely High Measurement Accuracy. 1.5 kVAC Galvanic Isolation. Programmable Sensor Error Value. Application: Linearized temperature measurement with Pt100...Pt1000, Ni100...Ni1000, or TC sensor. Conversion of linear resistance variation to a standard analog current... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Sensed Temperature: -328 to 4172
  • Other Input: Accepts Generic Resistance Inputs
  • Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
2-Wire Miniature Temperature Transmitters -- ETM2
from Tempco Electric Heater Corporation

The Tempco ETM Series of 2-wire transmitters are offered in isolated, non-isolated and high precision isolated versions. They are designed to fit in a standard aluminum, iron or plastic industrial connection head, DIN size B or larger. [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Connection: Screw Clamps or Lugs
  • Output: Analog Current (Typical 4-20 mA)
  • Supply Voltage: 6.5 to 36 VDC
Field-Mount Temperature Transmitter -- TTF200
from ABB Measurement & Analytics

The field-mount temperature transmitter TTF200 is provided for all HART standard applications in temperature measurement with one sensor. The transmitter supports the same functionality as the TTF300, but without sensor redundancy and sensor drift monitoring. It can be configured with ABB-tools such... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Output: Analog Current (Typical 4-20 mA)
  • Mounting Options: Field Mounted
  • Local Interface: Digital Front Panel
Thermocouple-to-DC Current/Voltage Converter with Relay Output -- DSCP62
from Dataforth Corporation

Each DSCP62 Thermocouple Converter provides a single channel of thermocouple input which is amplified, linearized and converted to a high-level current or voltage output. Thermocouple type, measurement range, filter, output type and range, and fault indication may be configured by dip-switch. An... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Output: Analog Current (Typical 4-20 mA); Analog Voltage
  • Mounting Options: DIN Rail Mounting
  • Connection: Screw Clamps or Lugs
Conax Transmitter Programmable LED Indicator, 2 Relay, Front Key Programmable -- 5714
from Conax Technologies

Programmable LED Indicator, 2 Relay, Front Key Programmable – Model 5714. * 4-Digit, 14-Segment LED Indicator. * Input for RTD, TC, mA, V, and Potentiometer. * Universal Supply Voltage. * Front Key Programmable. * Available with Optional 2 Relays and Analog Output. Application: * Display for... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Sensed Temperature: -328 to 4172
  • Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs; Accepts Generic Resistance Inputs
  • Mounting Options: Panel Mount, Rubber Gasket
2-Wire Miniature Temperature Transmitters -- ETM3
from Tempco Electric Heater Corporation

The Tempco ETM Series of 2-wire transmitters are offered in isolated, non-isolated and high precision isolated versions. They are designed to fit in a standard aluminum, iron or plastic industrial connection head, DIN size B or larger. [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Connection: Screw Clamps or Lugs
  • Output: Analog Current (Typical 4-20 mA)
  • Supply Voltage: 6.5 to 36 VDC
Head-Mount Temperature Transmitter -- TTH200
from ABB Measurement & Analytics

The TTH200 is provided for all HART standard applications in temperature measurement with one sensor input. The transmitter follows NAMUR Recommendations such as NE 89 and NE 107. The TTH200 supports the same functionality as the TTH300, but without sensor redundancy and sensor drift monitoring. As... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Output: Analog Current (Typical 4-20 mA)
  • Mounting Options: Head Mount
  • Features: Intrinsically Safe; Waterproof or Sealed Against Moisture
Conax Transmitter Programmable LED Indicator, 4 Relay, Front Key and PC Programmable -- 5715
from Conax Technologies

Programmable LED Indicator, 4 Relay, Front Key and PC Programmable Model 5715. * 4-Digit, 14-Segment LED Indicator. * Input for RTD, TC, mA, V, and Potentiometer. * 4 Relays with Optional Analog Output. * Universal Supply Voltage. * Programmable via Front Keypad or PC. Application: * Display for... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Sensed Temperature: -328 to 4172
  • Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs; Accepts Generic Resistance Inputs
  • Mounting Options: Panel Mount, Rubber Gasket
2-Wire Rail Mount Temperature Transmitters -- ETR1
from Tempco Electric Heater Corporation

The Tempco ETR Series of 2-wire transmitters is offered in isolated, non-isolated and high precision isolated versions. They are designed to fit directly on a standard 35 mm DIN rail. [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Connection: Screw Clamps or Lugs
  • Output: Analog Current (Typical 4-20 mA)
  • Supply Voltage: 8 to 32 VDC
TC Din-rail temperature transmitter Endress+Hauser iTEMP TMT128-JJNIA
from Automation24, Inc.

The iTEMP TMT128-JJNIA din-rail temperature transmitter from Endress+Hauser is designed for transformation of a TC thermocouple (type J) signal into a fixed range of measurement. The standardised output signal used for the process measurement is a 4 to 20 mA signal. That means fast, simple and... [See More]

  • Thermocouple: J
  • Output: Analog Current (Typical 4-20 mA)
  • Sensed Temperature: 1.4 to 1499
  • Connection: Screw Clamps or Lugs
TRX Temperature Transmitter
from FineTek

TRX Temperature Transmitter. 。Supply Voltage: Loop Power 18~32 Vdc. 。DCV Input: 0~500 mV/ 0~1V/ 0~5V/ 0~10V/ 0~20V. 。DCA Input: 0~20 mA/ 4~20 mA. 。Thermocouple Input: K / J / T / E / R / S / B / N. 。RTD/ Resistance Input: PT100/0~400W. 。Analog Output: 4~20... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Output: Analog Current (Typical 4-20 mA)
  • Sensed Temperature: -4 to 140
  • Supply Voltage: Loop Power 18~32 Vdc
Temperature Transmitter Field Circuit -- 9182
from R. STAHL, Inc.

One unit for nearly all temperature sensors indivdually configurable. Intrinsically safe input [Ex ia] IIC. Signal duplication possible. Galvanic isolation between input, output, power supply and configuration interface. Open-circuit and short-circuit monitoring and messaging (can be switched off). [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Mounting Options: DIN Rail Mounting
  • Sensed Temperature: -328 to 3213
  • Output: Analog Current (Typical 4-20 mA)
DIN Rail Universal Smart Transmitter -- TXDIN101
from OMEGA Engineering, Inc.

The TXDIN101 is a computerized, PC programmable, galvanically isolated two-wire smart transmitter. The unit converts 13 types of thermocouple sensors; 12 types of RTD sensors, configured as 2-, 3- and 4-wires; potentiometer, resistor and millivolt inputs, single or differential into process current... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Sensed Temperature: -328 to 4208
  • Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Resistance Inputs
  • Mounting Options: DIN Rail Mounting
Standard Rail Mount Transmitters
from Nanmac Corporation

The F11-40RM series is a basic, non-isolated, easy-to-use two-wire transmitter. Needing no external power supply other than your LOOP power, the F11-40RM can be used for three or four wire RTDs; as well as, thermocouple calibration types B, C (W5), E, J, K, N, R, S & T. Thermocouple input cold... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
4500H Temp Transmitter
from Ultra Energy

4500H Temp Transmitter, Industrial Temperature Transmitter, Head Mount RTD [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Output: Analog Current (Typical 4-20 mA)
  • Sensed Temperature: -328 to 1202
  • Local Interface: Computer Interface (optional feature)
Thermocouples
from Ashcroft Inc.

Ashcroft Thermocouples provide a reliable means for monitoring and controlling temperature. Designed to be used in conjunction with DIN 43772/T.2 or ISA-ds 49 thermowells. they are ideal an solution when high accuracy and reliability are vital. Designed for DIN 43772 thermowells. Manufactured to... [See More]

  • Thermocouple: E; J; K; N
2-wire HART® Transmitter -- 6335A
from PR electronics

RTD, TC, Ohm, or mV input. Extremely high measurement accuracy. HART ® 5 protocol. Galvanic isolation. 1- or 2-channel versionng [See More]

  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Supply Voltage: 8.0...35 VDC
  • Output: Analog Current (Typical 4-20 mA)
  • Operating Temperature: -40 to 140
Temperature Transmitters for Explosion Proof Sensor Assemblies
from Acrolab Ltd.

Explosion Proof Fixed Element RTD ’s are for use in U.S. and Canadian hazardous areas. They are designed to extinguish flames inside the device eliminating the potential for ignition of ammable mixtures in the surrounding atmosphere. FM and CSA approved assemblies, dependent on connection head... [See More]

  • Thermocouple: E; J; K; N; T
  • Output: Analog Current (Typical 4-20 mA)
Multi-Input Temperature Transmitter -- YTMX580
from Yokogawa Corporation of America

YTMX580 can accept inputs from up to 8 points of measurement such as thermocouples (8 types: K, E, J, etc.) or RTD signals (3 types: Pt100, etc.), converting the corresponding measurement input values to a wireless signal. It can also accept DC voltage, resistance, and 4 to 20 mA DC signal input. [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Operating Temperature: -40 to 185
  • Local Interface: Computer Interface
KS 816 Multi-Loop Multiple Transmitter & Temperature Controller
from West Control Solutions

The microprocessor-controlled KS 816 controller provides precise, low-cost multi-loop control of temperature and features an interface for bus or field-bus. The KS 816 can be used as a freely configurable field-bus transmitter with universal inputs for standard signals, thermocouples and Pt 100... [See More]

  • Thermocouple: E; J; K; N; T; S; R; W
  • Sensed Temperature: -328 to 4172
  • Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs; Accepts Generic Resistance Inputs
  • Mounting Options: DIN Rail Mounting
Thermocouple Transmitter -- 956047
from Durex Industries

Durex offers a two-wire universal head transmitter for installation in our DIN B Terminal Heads. These transmitters are configured by Durex to convert the signal from any type Thermocouple or RTD (2, 3 or 4 wire) into a linearized and isolated 4-20 mA signal. [See More]

  • Thermocouple: J; K
  • Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
  • Sensed Temperature: 32 to 2192
  • Output: Analog Current (Typical 4-20 mA)
Hart In-head Temperature Transmitter -- SEM310
from Status Instruments, Inc.

The SEM310 is a field mount temperature transmitter designed to replace the terminal block in a sensor head. It is fully encapsulated to ensure environmental integrity. Although small in size it out performs other larger and more expensive transmitters. Also available in DIN rail mount format... [See More]

  • Thermocouple: E; J; K; N; S; R
  • Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style); DIN Rail Mounting (optional feature)
  • Sensed Temperature: -328 to 3200
  • Output: Analog Current (Typical 4-20 mA)
Advanced Temperature Transmitters
from Azbil Corporation

These compact and lightweight smart temperature transmitters receive thermocouple input, RTD input, or mV input and transmit it as a 4 –20 mA DC or degital signal. They can be used with general-purpose signal cables, similar to other transmitters for flow or pressure measurement, eliminating... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Output: Analog Current (Typical 4-20 mA)
  • Other Input: Accepts Generic Analog Voltage Inputs
  • Local Interface: Digital Front Panel
Intelligent Temperature Transmitter, Universal Input, IntelliPack® 800T Series -- 801T-0500
from Acromag, Inc.

Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt ( ±100mV DC), 0 to 500 ohms input. 0 to 20mA DC, 0 to 10V DC output. Mechanical relay (25V @ 5A) alarm. 10-36V DC power. Software configured. Performs linearization, square root extraction, and optional limit alarm functions. [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Sensed Temperature: -382 to 1562
  • Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs
  • Mounting Options: DIN Rail Mounting
TC-Link® -1CH -LXRS™ 6 Channel Wireless Thermocouple Node
from LORD MicroStrain Sensing Systems

Overview. The TC-Link ® -1CH -LXRS ™ 6 Channel Wireless Thermocouple Node features a standard thermocouple input connector with an embedded cold junction temperature compensation sensor. On-board linearization algorithms are software programmable to support a wide range of thermocouple... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Local Interface: Computer Interface
  • Sensed Temperature: -346 to 3308
  • Connection: Plug or Quick Connect
TC Temperature head transmitter Endress+Hauser iTEMP TMT188-JJNGA
from Automation24, Inc.

The iTEMP TMT188-JJNGA temperature head transmitter from Endress+Hauser is designed for transformation of a TC thermocouple (type J) sensor signal into a fixed range of measurement. The standardised output signal used for the process measurement is a 4 to 20 mA signal. That means fast, simple and... [See More]

  • Thermocouple: J
  • Output: Analog Current (Typical 4-20 mA)
  • Sensed Temperature: 1.4 to 999
  • Connection: Screw Clamps or Lugs
Temperature Transmitter Field Circuit Non-Ex i 9182 -- 9182
from R. STAHL, Inc.

One unit for nearly all temperature sensors indivdually configurable. Signal duplication possible. Galvanic isolation between input, output, power supply and configuration interface. Open-circuit and short-circuit monitoring and messaging (can be switched off). Simple configuration with PC or... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Mounting Options: DIN Rail Mounting
  • Sensed Temperature: -328 to 3213
  • Output: Analog Current (Typical 4-20 mA)
Dual DIN Rail Temperature Transmitter -- TXDIN70
from OMEGA Engineering, Inc.

It provides 2 channels of configurable inputs, and supports multiple voltage, RTD, thermocouple inputs with auto reference junction compensation. If parallel connected to an external precise resistance, it accepts current signal input. Each channel has its own digital filtering and can adjust its... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Mounting Options: DIN Rail Mounting
  • Sensed Temperature: -328 to 4172
  • Output: Analog Current (Typical 4-20 mA)
7600D Temp Transmitter
from Ultra Energy

7600D Temp Transmitter, Industrial Temperature Transmitter, DIN Rail Mount, RTD, T/C, Ω, mV [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Mounting Options: DIN Rail Mounting
  • Sensed Temperature: -328 to 1562
  • Output: Analog Current (Typical 4-20 mA)
2-wire HART® Transmitter -- 6335D
from PR electronics

Application. Linearized temperature measurement with Pt100...Pt1000, Ni100...Ni1000, or TC sensor. Difference or average temperature measurement of 2 resistance or TC sensors. Conversion of linear resistance variation to a standard analog current signal, for instance from valves or Ohmic level... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Supply Voltage: 8.0...30 VDC
  • Output: Analog Current (Typical 4-20 mA)
  • Operating Temperature: -40 to 140
Push Button In Head Temperature Transmitter -- SEM203
from Status Instruments, Inc.

PUSH BUTTON IN HEAD TEMPERATURE TRANSMITTERS. SIMPLE PUSH BUTTON CONFIGURATION. HIGH STABILITY. INPUT/OUTPUT ISOLATION. 4 TO 20 mA TWO WIRE OUTPUT. PROGRAMMABLE BURNOUT. USER PUSH BUTTON TRIM. 10 YEAR WARRANTY [See More]

  • Thermocouple: E; J; K; N; T; S; R
  • Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
  • Sensed Temperature: -328 to 3200
  • Output: Analog Current (Typical 4-20 mA)
Thermocouple/millivolt Input Two-wire Dual Transmitter -- DT233
from Acromag, Inc.

DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT233 model is a dual two-wire transmitter that isolates and converts millivolt or thermocouple sensor inputs to proportional 4-20mA control signals. Power is received from the output loop... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Mounting Options: DIN Rail Mounting
  • Other Input: Accepts Generic Analog Voltage Inputs
  • Output: Analog Current (Typical 4-20 mA)
TC-Link® -6CH -LXRS™ 6 Channel Wireless Thermocouple Node
from LORD MicroStrain Sensing Systems

Overview. The TC-Link ® -6CH -LXRS ™ 6 Channel Wireless Thermocouple Node features six standard thermocouple input connectors, an embedded cold junction temperature compensation sensor, and an optional relative humidity sensor. On-board linearization algorithms are software programmable to... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Local Interface: Computer Interface
  • Sensed Temperature: -346 to 3308
  • Connection: Plug or Quick Connect
Field Rangeable Mini 2-Wire Transmitters -- TX901, TX903, TX904 and TX905
from OMEGA Engineering, Inc.

TX900 Series transmitters feature dip switch selection of input type and range. The following models are available: TX901 (non-isolated, accepts J, K,T, E, R or S thermocouples); TX903 (isolated, accepts J, K, T, E, R or S thermocouples; TX904 (non-isolated, accepts 100 ohm Pt RTD's 2- or 3- wire);... [See More]

  • Thermocouple: E; J; K; T; S; R
  • Sensed Temperature: 149 to 3193
  • Other Input: Accepts Generic Analog Voltage Inputs
  • Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
7600H Temp Transmitter
from Ultra Energy

7600H Temp Transmitter, Industrial Temperature Transmitter, Head Mount, RTD, T/C, Ω, mV [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Output: Analog Current (Typical 4-20 mA)
  • Sensed Temperature: -328 to 1562
  • Local Interface: Computer Interface (optional feature)
2-wire HART® Transmitter -- 6337A
from PR electronics

Application. Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100. HART ® communication and 4...20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors. Conversion of linear resistance to a standard... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Output: Analog Current (Typical 4-20 mA)
  • Mounting Options: DIN Rail Mounting
  • Connection: Screw Clamps or Lugs
Smart Universal Temperature Transmitter -- SEM210
from Status Instruments, Inc.

The SEM210 is a second generation ‘Smart ’ in head temperature transmitter that accepts any commonly used temperature sensor, Slidewire transducer or Millivolt signal and converts the output to the industry standard 4-20 mA transmission signal. The sensor type and range are easily... [See More]

  • Thermocouple: E; J; K; N; T; S; R
  • Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
  • Sensed Temperature: -328 to 3200
  • Output: Analog Current (Typical 4-20 mA)
Transmitter, Dual Channel, RTD Input, 600T Series -- 658T-0600
from Acromag, Inc.

100 ohm Pt, 120 ohm Ni, 10 ohm Cu (selectable type) input. 4 to 20mA DC output. 12-50V DC from output loop power. DIP-switch configuration, push-button calibration. These units accept universal RTD or resistance input signals and output proportional DC current signals. The output can also be... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Sensed Temperature: -382 to 3308
  • Other Input: Accepts Generic Analog Voltage Inputs
  • Mounting Options: DIN Rail Mounting
TC-Link®-OEM Wireless Thermocouple Node
from LORD MicroStrain Sensing Systems

Overview. The TC-Link ®-OEM Wireless Thermocouple Node provides a low cost way to embed wireless temperature sensing in industrial systems. TC-Link ®-OEM features six standard thermocouple input connectors with an embedded cold junction temperature compensation sensor. On-board linearization... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Local Interface: Computer Interface
  • Sensed Temperature: -346 to 3308
  • Supply Voltage: 3.2 - 9.0 VDC
High Power Wireless Transmitters -- zED-P
from OMEGA Engineering, Inc.

The rugged high-performance, high power OMEGA wiSeries wireless transmitters featured on this page are compatible with the OMEGA zSeries & wiSeries system for Web-based monitoring of Analog Voltage and Current, Temperature, Humidity, and Barometric Pressure. The radio is a High Power IEEE... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Sensed Temperature: -454 to 4208
  • Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs
  • Output: Analog Current (Typical 4-20 mA) (optional feature); Analog Voltage (optional feature)
9100D Temp Transmitter
from Ultra Energy

9100D Temp Transmitter, Industrial Temperature Transmitter, DIN Rail Mount, RTD, T/C, Ω, mV, HART [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Mounting Options: DIN Rail Mounting
  • Sensed Temperature: -328 to 1562
  • Output: Analog Current (Typical 4-20 mA)
2-wire HART® Transmitter -- 6337D
from PR electronics

Application. Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100. HART ® communication and 4...20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors. Conversion of linear resistance to a standard... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R; W
  • Output: Analog Current (Typical 4-20 mA)
  • Mounting Options: DIN Rail Mounting
  • Connection: Screw Clamps or Lugs
Temperature Transmitters -- TTC200
from Status Instruments, Inc.

RTD / slide wire / Ohms or thermocouple / mV inputs. Configuration using USB port powered configurator. Custom sensors accommodated. 22 segment user linearization for input. Sensor offset and output alignment. Programmable sensor burnout. High long term stability. Intrinsically safe versions... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
  • Sensed Temperature: -328 to 3272
  • Output: Analog Current (Typical 4-20 mA)
Transmitter, Single Channel, Thermocouple/mV Input, 600T Series -- 655T-0600
from Acromag, Inc.

TC (types J, K T, R, S, E, B, N), ±1V DC, selectable range/type input. 4 to 20mA DC output. 12-50V DC from output loop power. DIP-switch configuration, signal linearizer, push-button calibration. These units accept universal thermocouple and millivolt input signals, provide isolation, and... [See More]

  • Thermocouple: E; J; K; N; T; B; S; R
  • Mounting Options: DIN Rail Mounting
  • Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs
  • Output: Analog Current (Typical 4-20 mA)