VDE Isolation Transformers
from Schaffner EMC Inc.
Schaffner provides isolation multi-pulse drive transformers for variable speed and variable frequency drive applications. These units, also named rectifier transformers, are not just oversized standard units, but are designed specifically for inherent harmonics, minimal space requirements, and other... [See More]
- Agency: ANSI; CSA; IEC; UL; VDE; BS, DIN, EN IEEE, IRIS, ISO
- Power Rating (VA): 1.00E7
- Output Type: AC
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 12 Vac. Rated power 1.5 - 10 VA. Insulation class B. Maximum ambient temperature 70 °C. Efficiency up to 77 %. Degree of protection IP 00. Safety isolating transformer. to: VDE 0570 Teil 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 230 Vac. Rated power 160 - 2500 VA. Insulation class A. Maximum ambient temperature 40 °C. Degree of protection IP 67. Isolating transformer. to: VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4. Isolating transformer for the safe... [See More]
- Agency: VDE
- Input Voltage: 230
- Operating Frequency: 50 to 60
- Output Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 2 x 115 Vac. Rated power 60 - 1000 VA. Insulation class A or B. Maximum ambient temperature 40 °C. Efficiency up to 95 %. Degree of protection IP 20. Isolating transformer. to: VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4. [See More]
- Agency: VDE
- Input Voltage: 230
- Operating Frequency: 50 to 60
- Output Voltage: 115
from Block USA, Inc.
Rated input voltage 2 x 115 Vac. Rated output voltage 2 x 5 - 2 x 24 Vac. Rated power 2 - 52 VA. Insulation class E. Maximum ambient temperature 40 °C. Efficiency up to 81 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL... [See More]
- Agency: UL; VDE
- Input Voltage: 115
- Operating Frequency: 50 to 60
- Output Voltage: 12
from Block USA, Inc.
Rated input voltage 2 x 115 Vac. Rated output voltage I 9 Vac. Rated output voltage II 14.0-0-14.0 Vac. Rated power 4.34 - 37.3 VA. Insulation class E. Maximum ambient temperature 40 °C. Efficiency up to 78 %. Degree of protection IP 00. Safety isolating transformer. to: VDE 0570 Teil 2-6, DIN... [See More]
- Agency: UL; VDE
- Input Voltage: 115
- Operating Frequency: 50 to 60
- Power Rating (VA): 7.07
from Block USA, Inc.
Rated input voltage 2 x 115 Vac. Rated output voltage 2 x 6 - 2 x 21 Vac. Rated power 3 - 60 VA. Insulation class B. Maximum ambient temperature 70 °C. Efficiency up to 85 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1. [See More]
- Agency: UL; VDE
- Input Voltage: 115
- Operating Frequency: 50 to 60
- Output Voltage: 12
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 24 Vac. Rated power 3.2 - 16 VA. Insulation class B. Maximum ambient temperature 40 - 60 °C. Efficiency up to 76 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 24 Vac. Rated power 5 - 50 VA. Insulation class B. Maximum ambient temperature 40 - 50 °C. Efficiency up to 87 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 18 Vac. Rated power 4.5 - 50 VA. Insulation class B. Maximum ambient temperature 70 °C. Efficiency up to 84 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1. Safety... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 8 - 2 x 18 Vac. Rated power 4.5 - 30 VA. Insulation class B. Maximum ambient temperature 40 °C. Efficiency up to 84 %. Degree of protection IP 00. Safety isolating transformer. to: VDE 0570 Teil 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 - 690 Vac. Rated output voltage 12 - 230 Vac. Rated power 20 - 2500 VA. Insulation class B. Maximum ambient temperature 40 °C. Efficiency up to 96 %. Degree of protection IP 00. Control transformer. to: VDE 0570 Teil 2-2, DIN EN 61558-2-2, EN 61558-2-2, IEC 61558-2-2,. UL... [See More]
- Agency: UL; VDE
- Input Voltage: 230
- Operating Frequency: 50 to 60
- Output Voltage: 12
from Block USA, Inc.
Rated input voltage 210 - 540 Vac. Rated output voltage 24 - 230 Vac. Rated power 63 - 2500 VA. Insulation class B. Maximum ambient temperature 40 °C. Efficiency up to 95 %. Degree of protection IP 00. Control transformer. to: VDE 0570 Teil 2-2, DIN EN 61558-2-2, EN 61558-2-2, IEC 61558-2-2,. UL... [See More]
- Agency: UL; VDE
- Input Voltage: 210 to 540
- Operating Frequency: 50 to 60
- Output Voltage: 24
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 2 x 12 Vac. Rated power 60 - 800 VA. Insulation class A. Maximum ambient temperature 40 °C. Efficiency up to 95 %. Degree of protection IP 20. Safety isolating transformer. to: VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6. [See More]
- Agency: VDE
- Input Voltage: 230
- Operating Frequency: 50 to 60
- Output Voltage: 12
from Block USA, Inc.
Rated input voltage 2 x 115 Vac. Rated output voltage 2 x 6 - 2 x 18 Vac. Rated power 4 - 48 VA. Insulation class E. Maximum ambient temperature 40 °C. Efficiency up to 79 %. Degree of protection IP 00. Safety isolating transformer. to: VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC... [See More]
- Agency: VDE
- Input Voltage: 115
- Operating Frequency: 50 to 60
- Output Voltage: 12
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 2 x 6 - 2 x 18 Vac. Rated power 4 - 35 VA. Insulation class E. Maximum ambient temperature 40 °C. Efficiency up to 78 %. Degree of protection IP 00. Safety isolating transformer. to: VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC... [See More]
- Agency: VDE
- Input Voltage: 230
- Operating Frequency: 50 to 60
- Output Voltage: 12
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 24 Vac. Rated power 4.5 - 30 VA. Insulation class E. Maximum ambient temperature 40 °C. Efficiency up to 83 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 24 Vac. Rated power 0.35 - 3.2 VA. Insulation class B. Maximum ambient temperature 70 °C (VB 3,2 max. 50 °C). Efficiency up to 58 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1,... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 24 Vac. Rated power 0.5 VA. Insulation class B. Maximum ambient temperature 70 °C. Efficiency up to 37 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL 5085-1/-2,... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 18 Vac. Rated power 0.7 - 3 VA. Insulation class B. Maximum ambient temperature 70 °C. Efficiency up to 59 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1. Safety... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230