UL Isolation Transformers
Last Updated: January 16, 2025 Reviewed by: Jon Lowy, consulting engineer
Description
UL Isolation Transformers are designed to provide electrical isolation between their input and output windings. This isolation helps to prevent electrical shock and reduce electrical noise in the system. These transformers are constructed with heavy-duty shields and insulation between the coils to effectively prevent arcing and electric shock. They may also feature ruggedized metal housing to further increase safety.
Working Principle
Isolation transformers work by using electromagnetic induction to transfer electrical energy between two or more windings. The primary and secondary windings are not electrically connected but are magnetically coupled through a core. This design allows the transformer to isolate portions of the circuit, preventing shock and reducing electromagnetic interference. The Faraday shields used in these transformers help to block electric fields from interrupting current flow, thereby reducing electromagnetic interference on the signal line and improving power quality and device efficiency.
Applications
Isolation transformers are widely used in various applications to ensure safety and improve performance. In medical settings, they are crucial for isolating medical devices to prevent electrical shock and ensure reliable operation. For example, they are used in medical imaging equipment, patient monitoring systems, and surgical devices. In industrial environments, they are used to isolate sensitive equipment from electrical noise and potential faults in the power supply. They are also used in audio and video equipment to prevent ground loops and improve signal quality.
Advantages over other Isolation Transformers
One of the main advantages of UL Isolation Transformers is their compliance with stringent safety standards such as UL 544, UL 2601, and UL 60601, which are critical for medical applications. These transformers are designed with extremely low levels of current leakage and minimum creepage distance, making them safer and more reliable for sensitive applications. Additionally, the use of Faraday shields and heavy-duty insulation provides better protection against electromagnetic interference and electrical noise compared to other types of isolation transformers.
Limitations
Despite their advantages, UL Isolation Transformers have some limitations. They are generally bulkier and heavier than other types of transformers, such as autotransformers, due to the additional insulation and shielding required for safety. This can make them less suitable for applications where space and weight are critical factors. Additionally, they are typically more expensive due to the higher quality materials and construction standards required to meet UL certifications.
Considerations
When selecting a UL Isolation Transformer, several factors should be considered. Initial costs can be higher due to the stringent safety standards and high-quality materials used in their construction. Operating expenses may also be higher due to the need for regular maintenance to ensure continued compliance with safety standards. However, their durability and reliability can offset these costs over time. It's important to consider the specific requirements of the application, such as the need for low current leakage, high insulation resistance, and effective electromagnetic interference reduction. Replacement and maintenance costs should also be factored in, as these transformers may require periodic inspections and testing to ensure they continue to meet safety standards.
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // 11KV 15KV Outdoor Prefabrical Substation Transformers High Voltage Compact Electrical Box Type Substation [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer
- Output Type: AC
from Triad Magnetics
Triad PC mount World Series transformers incorporate a dual bobbin construction with an insulating shroud, both made of a high temperature material that exceeds UL flammability requirements. These units are designed with very high isolation between the primary and secondary, and also, between each... [See More]
- Agency: CSA; UL; CSA IEC TUV UL
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 115 to 230
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // 1000KVA to 3000KVA transformer [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // ANSI/UL/Transformer//1500KVA 1600KVA SCB Dry Transformer [See More]
- Agency: RoHS; ANSI; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // 1KVA 2KVA 3KVA 4KVA 5KVA Transformer Without box [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers (optional feature); Single Phase Transformer
- Winding Turns: Step-Up Transformer; Step-Down Transformer
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // 250KVA Step up Down Transformer Price 250 Kva for CNC Factory for Office Building for Shopping Mall [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer; One to One
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // 3 Phase 3kva 5kva 7kva 10kva 15kva 30kva Step Down up Isolation Transformer [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer; One to One (optional feature)
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // ANSI/UL/Transformer//3500KVA 3000 KVA Cast Resin Dry Type Transformer SCB13 SCB14 SCB15 [See More]
- Agency: RoHS; ANSI; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // 380V 480V 420V 440V Manufacturer Direct Hot Selling Three Phase Dry Type Voltage Transformer [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers; Single Phase Transformer
- Winding Turns: Step-Up Transformer; Step-Down Transformer; One to One (optional feature)
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // 3KVA 5KVA 7KVA 10KVA Isolation Three Phase Power Transformer 15KVA 20KVA 30KVA 40KVA 50KVA 60KVA [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers (optional feature); Single Phase Transformer
- Winding Turns: Step-Up Transformer; Step-Down Transformer
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // 500KVA 630KVA 3 Phase MV &HV transformers Dry Power Step Down Transformer 380V 415V 400V 440V to 380V 415V 400V 250KVA 600KVA 800KVA 1000KVA [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer; One to One (optional feature)
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // 500KVA 800KVA 750 KVA 630KVA 400KVA Dry Transformer 400KW Step up Down Transformer 380V 400V 415V 440V to 380V 400V 440V 415V [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer; One to One (optional feature)
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // 50HZ 60HZ Box-type Prefabricated Substation Transformer Converting Station [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // Factory Price Resin Cast Dry Type Transformer 50KVA 100KVA 200KVA 315KV 400KVA 500KVA 600KVA Upto 2.5MVA 6.0KV 6.6KV 11KV [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer; One to One (optional feature)
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // 700KVA 900KVA 1000KVA Outdoor Photovoltaic Transformer IP54 800kva Solar PV Transformer [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer; One to One (optional feature)
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // ANSI/UL/Transformer//600KVA 800KVA SCB Dry Transformer [See More]
- Agency: RoHS; ANSI; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // 800v 400v transformer [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer; One to One (optional feature)
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // 98% Efficiency 400KVA 500KVA Power Transformer Outdoor Indoor 400 500 KVA 3 Phase Transformer Customizable [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers (optional feature); Single Phase Transformer
- Winding Turns: Step-Up Transformer; Step-Down Transformer
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // 98% Efficiency Step up Down Voltage 220V to 380V 110V 440V Transformer 3 Phase Pure Sine Wave [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers; Single Phase Transformer
- Winding Turns: Step-Up Transformer; Step-Down Transformer; One to One (optional feature)
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // Automatic 300KVA 400KVA 500KVA Transformer Price 300 400 500 KVA [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer; One to One
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // Copper 200KVA 3 Phase Dry Type Transformer Price 3phase 200 KVA 200KW [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // Custom Transform Auto Transformers Electrical Power 380v to 220v [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer; One to One (optional feature)
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // Durable 100KVA 3 Phase Power Transformer Price 100 KVA 150KVA 80KVA 90KVA [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers; Single Phase Transformer
- Winding Turns: Step-Up Transformer; Step-Down Transformer
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // Durable 250KVA Voltage Transformer Price 250 KVA [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // H Insulation NEMA Enclosure 220v to 380v 440v 415v Step up 3 Phase Transformer 50 75 100 Kva Auto 50kva Transformer Price [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers
- Winding Turns: Step-Up Transformer; Step-Down Transformer; One to One (optional feature)
- Output Type: AC
from Shenzhen Xingkerong Technology Co., Ltd
Home // All Collections // Transformer // IEC NEC Dry Type Isolation Power Transformer Price Dry-type Single or Three Phase Transformer [See More]
- Agency: RoHS; IEC; UL; CE
- Other Transformer Types / Applications: Three Phase Transformers; Single Phase Transformer
- Winding Turns: Step-Up Transformer; Step-Down Transformer
- Output Type: AC
from Automation24, Inc.
Single phase low voltage distribution transformer T253008S from Acme Electric has an input voltage of 240, 480 V AC, and an output voltage of 120, 240 V AC with a power rating of 0.5 kVA. The dry type transformer T253008S also provides excellent ingress protection with it's NEMA 3R enclosure for... [See More]
- Agency: UL
- Mounting: Screw mounting
- Output Type: AC
- Operating Frequency: 50 to 60
from Toroid Corp. of Maryland
Wall, chassis, table top and cart installations, aluminum enclosure [See More]
- Agency: CSA; UL
- Output Type: AC
- Other Transformer Types / Applications: Toroidal Core
- Mounting: Chassis; Wall Mount
from Acme Electric Corp. / Power Distribution Products
All Acme Drive Isolation Transformers (DITs) above 7.5kVA are wound with strip windings to ensure the lowest possible eddy current losses. All our DITs use a three leg wound core. This superior design has very low losses and quiet operation. Both of these features combine to significantly reduce... [See More]
- Agency: ANSI; CSA; UL; CE and IEEE
- Output Type: AC
- Winding Turns: Step-Down Transformer
- Mounting: Pad-Mounted
from Schaffner EMC Inc.
Schaffner provides isolation multi-pulse drive transformers for variable speed and variable frequency drive applications. These units, also named rectifier transformers, are not just oversized standard units, but are designed specifically for inherent harmonics, minimal space requirements, and other... [See More]
- Agency: ANSI; CSA; IEC; UL; VDE; BS, DIN, EN IEEE, IRIS, ISO
- Power Rating (VA): 1.00E7
- Output Type: AC
from Mirus International, Inc.
Designed to replace standard drive isolation transformers, the Drive Tamer ™ is built to not only withstand the harsh harmonic environment produced by Variable Frequency Drives (VFD) but to also induce cancellation of harmonics upstream and thereby reduce voltage distortion throughout the... [See More]
- Agency: CSA; UL
- Power Rating (VA): 660000
- Input Voltage: 600
from Premier Magnetics, Inc.
Designed for 10/100MB/s Transmission Over UTP-5 Cable, IEEE 802.3u & ANSI X3.236-1995. Maintains > 350uHY Primary OCL with an 8mA bias over the full temp range of 0 to +70 O C. Supports all leading Fast Ethernet Chip Sets that require a 1:1 Transmit & Receive Turns Ratio. Provides the... [See More]
- Agency: UL
- Operating Temperature: 0 to 70
- Mounting: PCB/SMD
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 12 Vac. Rated power 1.5 - 10 VA. Insulation class B. Maximum ambient temperature 70 °C. Efficiency up to 77 %. Degree of protection IP 00. Safety isolating transformer. to: VDE 0570 Teil 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Tripp Lite by Eaton
Tripp Lite's SU20KXFMRT4U step-down, isolation transformer converts 208 or 240V input from any 60Hz generator, utility or UPS high voltage source to 240/120V output. 208 or 240V hardwire input connection and hardwire 240/120V output. Supports 4U rackmount installation in 4 post racks with included... [See More]
- Agency: RoHS; CSA; UL
- Mounting: Rack/Tower (2U)
- Winding Turns: Step-Down Transformer
- Operating Frequency: 60
from Powertronix Inc.
Dental Transformers are used in medical devices that require improved electrical isolation and helps to reduce leakage current. Our product provides protection to abnormal operating conditions such as over load, over current and improvised cooling, as well as filter power disturbances and noises. [See More]
- Agency: RoHS; IEC; UL
- Mounting: Chassis; Center Potted with Thru Hole, L Bracket, Customer Defined
- Other Transformer Types / Applications: Single Phase Transformer
- Input Voltage: 120 to 230
from Automation24, Inc.
Single phase low voltage distribution transformer T253010S from Acme Electric has an input voltage of 240, 480 V AC, and an output voltage of 120, 240 V AC with a power rating of 1 kVA. The dry type transformer T253010S also provides excellent ingress protection with it's NEMA 3R enclosure for both... [See More]
- Agency: UL
- Mounting: Screw mounting
- Output Type: AC
- Operating Frequency: 50 to 60
from Acme Electric Corp. / Power Distribution Products
Non-linear loads generate high levels of harmonic currents. When supplying power to these loads, a special transformer design is necessary. Typical non-linear loads include desktop computers, AC variable speed drives, HID lighting, electronic ballasts, inverters and welders. Of these non-linear... [See More]
- Agency: ANSI; CSA; UL; CE and IEEE
- Output Type: AC
- Winding Turns: Step-Down Transformer
- Mounting: Pad-Mounted
from Premier Magnetics, Inc.
— Designed for Use with Power Integrations, Inc. TinySwitch Series Off-Line Switcher Controllers —. Designed to meet a Universal Input of 85Vac to 265Vac, 47Hz to 440Hz. Up to 6000Vrms of Isolatio [See More]
- Agency: CSA; IEC; UL
- Mounting: PCB/SMD
- Winding Turns: One to One
- Operating Temperature: 0 to 70
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 2 x 115 Vac. Rated power 60 - 1000 VA. Insulation class A or B. Maximum ambient temperature 40 °C. Efficiency up to 95 %. Degree of protection IP 20. Isolating transformer. to: VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4. [See More]
- Agency: UL; VDE
- Input Voltage: 230
- Operating Frequency: 50 to 60
- Output Voltage: 115
from Tripp Lite by Eaton
Isolator Series UL 60601-1 Listed Medical-Grade Isolation Transformers offer line isolation and continuous noise filtering. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL 60601-1 medical-grade listing with hospital-grade plug and... [See More]
- Agency: UL
- Input Voltage: 120
- Mounting: Tower
- Features: Medical Grade
from Powertronix Inc.
High Voltage Toroidal Transformers are designed light weight, small in size, high efficient and high reliability for rough environmental conditions. High Voltage Transformers also provide electrical isolation, power distribution and control and instrumentation applications. APPLICATIONS. Popular for... [See More]
- Agency: RoHS; UL
- Mounting: Flange Mount, Custom
- Other Transformer Types / Applications: Toroidal Core; Single Phase Transformer
- Power Rating (VA): 1000 to 45000
from Automation24, Inc.
Single phase low voltage distribution transformer T253012S from Acme Electric has an input voltage of 240, 480 V AC, and an output voltage of 120, 240 V AC with a power rating of 2 kVA. The dry type transformer T253012S also provides excellent ingress protection with it's NEMA 3R enclosure for both... [See More]
- Agency: UL
- Mounting: Screw mounting
- Output Type: AC
- Operating Frequency: 50 to 60
from Block USA, Inc.
Rated input voltage 3 x 400 Vac. Rated output voltage 3 x 380 - 3 x 420 Vac. Rated power 1000 - 30000 VA. Insulation class F. Maximum ambient temperature 50 °C. Efficiency up to 97.5 %. Degree of protection IP 00. Optionally adapted package for higher degrees of protection (see data table). [See More]
- Agency: UL
- Input Voltage: 400
- Operating Frequency: 50 to 60
- Output Voltage: 400
from Tripp Lite by Eaton
Isolator Series UL 60601-1 Listed Medical-Grade Isolation Transformers offer line isolation and continuous noise filtering. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL 60601-1 medical-grade listing with hospital-grade plug and... [See More]
- Agency: UL
- Input Voltage: 120
- Mounting: Tower
- Features: Medical Grade
from Powertronix Inc.
Isolation Transformers are distinguished by their small size, light weight and high efficiency. They are built to form, fit and function and can be provided with one or more primary windings and one or more secondary windings. APPLICATIONS. Industrial Automation. Electrical Equipment. Transformer... [See More]
- Agency: RoHS; UL
- Mounting: Center Potted with Thru Hole, Flange, Excapsulated, Custom Mounting Bracket
- Other Transformer Types / Applications: Toroidal Core; Single Phase Transformer
- Power Rating (VA): 18 to 15000
from Automation24, Inc.
Single phase control tranformer TB1000N005F0 from Acme Electric has an input voltage of 208, 230, 460 V AC, and an output voltage of 115 V AC with a power rating of 1 kVA. The TB1000N005F0 also provides hassle free installation with convenient oblong mounting holes. Easily transform the required... [See More]
- Agency: UL
- Mounting: Screw mounting
- Output Type: AC
- Operating Frequency: 50 to 60
from Block USA, Inc.
Rated input voltage 208 - 600 Vac. Rated output voltage 24 - 230 Vac. Rated power 100 - 3200 VA. Insulation class B. Maximum ambient temperature 40 °C. Efficiency up to 96 %. Degree of protection IP 00. Control transformer. to: VDE 0570 Teil 2-2, DIN EN 61558-2-2, EN 61558-2-2, IEC 61558-2-2,. [See More]
- Agency: UL
- Input Voltage: 208 to 600
- Operating Frequency: 50 to 60
- Output Voltage: 115
from Tripp Lite by Eaton
Isolator Series UL 60601-1 Listed Medical-Grade Isolation Transformers offer line isolation and continuous noise filtering. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL 60601-1 medical-grade listing with hospital-grade plug and... [See More]
- Agency: UL
- Input Voltage: 120
- Mounting: Tower
- Features: Medical Grade
from Automation24, Inc.
Single phase control tranformer TB1000N008F0 from Acme Electric has an input voltage of 220, 230, 240, 440, 460, 480 V AC, and an output voltage of 110/115/120 V AC with a power rating of 1 kVA. The TB1000N008F0 also provides hassle free installation with convenient oblong mounting holes. Easily... [See More]
- Agency: UL
- Mounting: Screw mounting
- Output Type: AC
- Operating Frequency: 50 to 60
from Block USA, Inc.
Rated input voltage 2 x 115 Vac. Rated output voltage 2 x 5 - 2 x 24 Vac. Rated power 2 - 52 VA. Insulation class E. Maximum ambient temperature 40 °C. Efficiency up to 81 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL... [See More]
- Agency: UL; VDE
- Input Voltage: 115
- Operating Frequency: 50 to 60
- Output Voltage: 12
from Tripp Lite by Eaton
Isolator Series UL 60601-1 Listed Medical-Grade Isolation Transformers offer line isolation and continuous noise filtering. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL 60601-1 medical-grade listing with hospital-grade plug and... [See More]
- Agency: UL
- Input Voltage: 120
- Mounting: Tower
- Features: Medical Grade
from Automation24, Inc.
Single phase control tranformer TB2000N005F0 from Acme Electric has an input voltage of 208, 230, 460 V AC, and an output voltage of 115 V AC with a power rating of 2 kVA. The TB2000N005F0 also provides hassle free installation with convenient oblong mounting holes. Easily transform the required... [See More]
- Agency: UL
- Mounting: Screw mounting
- Output Type: AC
- Operating Frequency: 50 to 60
from Block USA, Inc.
Rated input voltage 2 x 115 Vac. Rated output voltage I 9 Vac. Rated output voltage II 14.0-0-14.0 Vac. Rated power 4.34 - 37.3 VA. Insulation class E. Maximum ambient temperature 40 °C. Efficiency up to 78 %. Degree of protection IP 00. Safety isolating transformer. to: VDE 0570 Teil 2-6, DIN... [See More]
- Agency: UL; VDE
- Input Voltage: 115
- Operating Frequency: 50 to 60
- Power Rating (VA): 7.07
from Automation24, Inc.
Single phase control tranformer TB2000N008F0 from Acme Electric has an input voltage of 240, 480 V AC, and an output voltage of 120 V AC with a power rating of 2 kVA. The TB2000N008F0 also provides hassle free installation with convenient oblong mounting holes. Easily transform the required power... [See More]
- Agency: UL
- Mounting: Screw mounting
- Output Type: AC
- Operating Frequency: 50 to 60
from Block USA, Inc.
Rated input voltage 2 x 115 Vac. Rated output voltage 2 x 6 - 2 x 21 Vac. Rated power 3 - 60 VA. Insulation class B. Maximum ambient temperature 70 °C. Efficiency up to 85 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1. [See More]
- Agency: UL; VDE
- Input Voltage: 115
- Operating Frequency: 50 to 60
- Output Voltage: 12
from Automation24, Inc.
Single phase control tranformer TB350N001 from Acme Electric has an input voltage of 120, 240 V AC, and an output voltage of 12, 24 V AC with a power rating of 0.3 kVA. The TB350N001 also provides hassle free installation with convenient oblong mounting holes. Easily transform the required power... [See More]
- Agency: UL
- Mounting: Screw mounting
- Output Type: AC
- Operating Frequency: 50 to 60
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 24 Vac. Rated power 3.2 - 16 VA. Insulation class B. Maximum ambient temperature 40 - 60 °C. Efficiency up to 76 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Automation24, Inc.
Single phase control tranformer TB500N005F0 from Acme Electric has an input voltage of 208, 230, 460 V AC, and an output voltage of 115 V AC with a power rating of 0.5 kVA. The TB500N005F0 also provides hassle free installation with convenient oblong mounting holes. Easily transform the required... [See More]
- Agency: UL
- Mounting: Screw mounting
- Output Type: AC
- Operating Frequency: 50 to 60
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 24 Vac. Rated power 5 - 50 VA. Insulation class B. Maximum ambient temperature 40 - 50 °C. Efficiency up to 87 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Automation24, Inc.
Single phase control tranformer TB500N008F0 from Acme Electric has an input voltage of 220, 230, 240, 440, 460, 480 V AC, and an output voltage of 110/115/120 V AC with a power rating of 0.5 kVA. The TB500N008F0 also provides hassle free installation with convenient oblong mounting holes. Easily... [See More]
- Agency: UL
- Mounting: Screw mounting
- Output Type: AC
- Operating Frequency: 50 to 60
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 18 Vac. Rated power 4.5 - 50 VA. Insulation class B. Maximum ambient temperature 70 °C. Efficiency up to 84 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1. Safety... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Automation24, Inc.
Single phase low voltage distribution transformer TF217437S from Acme Electric has an input voltage of 190, 200, 208, 220, 380, 400, 416, 440 V AC, and an output voltage of 120, 240 V AC with a power rating of 1 kVA. The dry type transformer TF217437S also provides excellent ingress protection with... [See More]
- Agency: UL
- Mounting: Screw mounting
- Output Type: AC
- Operating Frequency: 50 to 60
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 8 - 2 x 18 Vac. Rated power 4.5 - 30 VA. Insulation class B. Maximum ambient temperature 40 °C. Efficiency up to 84 %. Degree of protection IP 00. Safety isolating transformer. to: VDE 0570 Teil 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Automation24, Inc.
Single phase low voltage distribution transformer TF217439S from Acme Electric has an input voltage of 190, 200, 208, 220, 380, 400, 416, 440 V AC, and an output voltage of 120, 240 V AC with a power rating of 2 kVA. The dry type transformer TF217439S also provides excellent ingress protection with... [See More]
- Agency: UL
- Mounting: Screw mounting
- Output Type: AC
- Operating Frequency: 50 to 60
from Block USA, Inc.
Rated input voltage 230 - 690 Vac. Rated output voltage 12 - 230 Vac. Rated power 20 - 2500 VA. Insulation class B. Maximum ambient temperature 40 °C. Efficiency up to 96 %. Degree of protection IP 00. Control transformer. to: VDE 0570 Teil 2-2, DIN EN 61558-2-2, EN 61558-2-2, IEC 61558-2-2,. UL... [See More]
- Agency: UL; VDE
- Input Voltage: 230
- Operating Frequency: 50 to 60
- Output Voltage: 12
from Block USA, Inc.
Rated input voltage 230 - 400 Vac. Rated output voltage 24 - 230 Vac. Rated power 63 - 2500 VA. Insulation class B. Maximum ambient temperature 40 °C. Efficiency up to 95 %. Degree of protection IP 00. Control transformer. to: VDE 0570 Teil 2-2, DIN EN 61558-2-2, EN 61558-2-2, IEC 61558-2-2,. UL... [See More]
- Agency: UL
- Input Voltage: 230
- Operating Frequency: 50 to 60
- Output Voltage: 24
from Block USA, Inc.
Rated input voltage 230 and 400 Vac. Rated output voltage 24 - 230 Vac. Rated power 63 - 2500 VA. Insulation class B. Maximum ambient temperature 40 °C. Efficiency up to 94 %. Degree of protection IP 00. Control transformer. to: VDE 0570 Teil 2-2, DIN EN 61558-2-2, EN 61558-2-2, IEC 61558-2-2,. [See More]
- Agency: UL
- Input Voltage: 230 to 400
- Operating Frequency: 50 to 60
- Output Voltage: 115
from Block USA, Inc.
Rated input voltage 210 - 540 Vac. Rated output voltage 24 - 230 Vac. Rated power 63 - 2500 VA. Insulation class B. Maximum ambient temperature 40 °C. Efficiency up to 95 %. Degree of protection IP 00. Control transformer. to: VDE 0570 Teil 2-2, DIN EN 61558-2-2, EN 61558-2-2, IEC 61558-2-2,. UL... [See More]
- Agency: UL; VDE
- Input Voltage: 210 to 540
- Operating Frequency: 50 to 60
- Output Voltage: 24
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 2 x 12 Vac. Rated power 60 - 800 VA. Insulation class A. Maximum ambient temperature 40 °C. Efficiency up to 95 %. Degree of protection IP 20. Safety isolating transformer. to: VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6. [See More]
- Agency: UL; VDE
- Input Voltage: 230
- Operating Frequency: 50 to 60
- Output Voltage: 12
from Block USA, Inc.
Rated input voltage 2 x 115 Vac. Rated output voltage 6 - 2 x 24 Vac. Rated power 0.35 - 3.2 VA. Insulation class B. Maximum ambient temperature 70 °C (AVB 3,2 max. 50 °C). Efficiency up to 59 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN... [See More]
- Agency: UL
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 115
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 24 Vac. Rated power 4.5 - 30 VA. Insulation class E. Maximum ambient temperature 40 °C. Efficiency up to 83 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 24 Vac. Rated power 0.35 - 3.2 VA. Insulation class B. Maximum ambient temperature 70 °C (VB 3,2 max. 50 °C). Efficiency up to 58 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1,... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 24 Vac. Rated power 0.5 VA. Insulation class B. Maximum ambient temperature 70 °C. Efficiency up to 37 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL 5085-1/-2,... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 18 Vac. Rated power 0.7 - 3 VA. Insulation class B. Maximum ambient temperature 70 °C. Efficiency up to 59 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1. Safety... [See More]
- Agency: UL; VDE
- Operating Frequency: 50 to 60
- Mounting: PCB/SMD
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 2 x 115 Vac. Rated output voltage 2 x 12 - 2 x 115 Vac. Power 15 - 3000 VA. Insulation class B. Maximum ambient temperature 40 °C. Efficiency up to 98 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL... [See More]
- Agency: UL
- Input Voltage: 115
- Operating Frequency: 50 to 60
- Output Voltage: 12
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 2 x 12 - 2 x 35 Vac. Power 15 - 625 VA. Insulation class B. Maximum ambient temperature 40 °C. Efficiency up to 95 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL... [See More]
- Agency: UL
- Input Voltage: 230
- Operating Frequency: 50 to 60
- Output Voltage: 12