Supplier: Accuris
Description: Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors
-
Supplier: Accuris
Description: Fire detection and fire alarm systems - Part 30: Multi-sensor fire detectors - Point detectors using a combination of carbon monoxide and heat sensors
-
Supplier: Accuris
Description: Fire detection and fire alarm systems Part 29: Multi-sensor fire detectors \x97 Point detectors using a combination of smoke and heat sensors
-
-
Supplier: Accuris
Description: Fire detection and fire alarm systems Part 30: Multi-sensor fire detectors \x97 Point detectors using a combination of carbon monoxide and heat sensors
-
Supplier: Electro Optical Components, Inc.
Description: Micro-Hybrid Electronic GmbH produces high performance pyroelectric detectors and NDIR gas sensors, as well as thermopile infrared detectors and IR sources. View the Micro-Hybrid video at the bottom of this page. Pyroelectric detectors are available in voltage and in current
- Responsivity: 0.95 to 1,100 mV/µW
- Detectivity: 1.7 to 5.87 10^8cmHz^(½)/W
- Category: Sensor / Transducer
-
Supplier: Honeywell Analytics, Inc.
Description: The Fire Sentry FS20X is the latest generation high technology Multi-Spectrum (UV/Dual IR/VIS) Fire and Flame Detector, which is part of the FSX family of advanced technology Electro-Optical Flame detectors. Based on the foundation of the highly successful and
- Maximum Response Time: 3 to 10 seconds
- Maximum Detector Range (Sensitivity): 200 ft
- Operating Temperature: -40 to 185 F
- Output Options: Analog Current, Switch or Alarm
-
Supplier: MSA Safety
Description: The MSA General Monitors® FL5000 MSIR Flame Detector sets a high standard in industrial fire protection with advanced multi-spectrum IR sensing and AI-driven flame recognition. It detects fires up to 310 feet away while minimizing false alarms from sources like sunlight
- Maximum Response Time: 10 seconds
- Maximum Detector Range (Sensitivity): 70 to 310 ft
- Operating Temperature: -67 to 176 F
- Features: Adjustable Time Delay, Automatic Self-test, Explosion Proof, Other
-
Supplier: Spectrex, Inc.
Description: The 40/40M Multi IR Flame Detector is specifically designed for detection of hydrocarbon and hydrogen flames. It detects hydrocarbon-based fuel and gas fires at long distances with the highest immunity to false alarms. The 40/40M can detect a gasoline pan fire at 215 ft
-
Supplier: Emerson Automation Solutions – Rosemount
Description: State-of-the-art multi-spectrum infrared technology detects hydrocarbon fuel and gas fires while delivering superior reliability and immunity to false alarms with enhanced overall coverage. Make the right decision when it counts — when safety is on the line Enhance safety and minimize
- Maximum Response Time: 5 seconds
- Maximum Detector Range (Sensitivity): 215 ft
- Operating Temperature: -67 to 185 F
- Features: Adjustable Time Delay, Automatic Self-test, Other
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Multi-spectrum infrared sensing technology detects ‘invisible’ hydrogen fires at long distances with high false alarm immunity. Optimize Safety Coverage Long range detection of hydrogen based fires Operate at your full potential Enhanced false alarm immunity helps you reduce
- Maximum Response Time: 3 seconds
- Maximum Detector Range (Sensitivity): 66 ft
- Operating Temperature: -67 to 185 F
- Features: Adjustable Time Delay, Automatic Self-test, Other
-
Supplier: Electro Optical Components, Inc.
Description: Electro Optical Components offers high performance pyroelectric and thermopile detectors as well as IR sources. Detectors that measure radiation by means of the change of temperature of an absorbing material are classified as thermal detectors, often referred to as temperature
- Operating Temperature: -4 to 158 F
- Detectivity: 2.95 to 3.5 10^8cmHz^(½)/W
- Category: Sensor / Transducer
- Technology: Thermal Pyrometer / Detector
-
Supplier: UL Standards & Engagement
Description: detector assembly, and covered by the Standard for Heat Actuated Fire Detectors for Fire Alarm Systems, ULC-S530 and/or when part of a multi-criteria smoke detector; 4) Fire tests for smoke detectors integral with combination door closers and
-
Description: buildings. For the testing of other types of CO multi-sensor fire detectors, or CO and heat multi-sensor fire detectors working on different principles, ISO 7240-8:2007 can be used for guidance. CO and heat multi-sensor fire detectors
-
Supplier: CSA Group
Description: 7240‑1). For the testing of other types of CO multi-sensor fire detectors, or CO and heat multi-sensor fire detectors working on different principles, this part of ISO 7240 is only to be used for guidance. CO and heat multi-sensor fire
-
Supplier: Terra Universal, Inc.
Description: pre-fire and actual fire detector-sensor spectral data from the last six fire events in nonvolatile memory for subsequent analysis
- Maximum Detector Range (Sensitivity): 8 ft
- Output Options: Analog Voltage, Switch or Alarm
- Sensor Technology: Multi-IR Detector
- Device Classification: Sensor System
-
Supplier: Southwire Company, LLC
Description: COLOR CODE PVC JACKET MATERIAL REEL PACKAGE TYPE SOLID STRANDING WHITE JACKET COLOR NON-SHIELDED SHIELDING TYPE INSULATION THICKNESS 0.006 INCH JACKET THICKNESS 0.014 INCH INSULATED CONDUCTOR DIAMETER 0.052 INCH APPLICATION FIRE ALARM, SIGNALING, SMOKE DETECTOR, FIRE PROTECTIVE
- Number of Conductors: 2 #
- Rated Voltage: 0.3 kilovolts
- Operating Temperature: -20 to 60 C
- North American (AWG): 18 AWG
-
Description: ISO 7240-27:2009 specifies requirements, test methods and performance criteria for multi-sensor point-type fire detectors that incorporate an optical or ionization smoke sensor, an electro-chemical cell for sensing carbon monoxide (CO) and, optionally, one or more heat sensors,
-
Supplier: General Cable
Description: PULL-PAC PACKAGE TYPE SOLID STRANDING RED JACKET COLOR NON-SHIELDED SHIELDING TYPE INSULATION THICKNESS 0.01 INCH APPLICATION FIRE/BURGLAR ALARM, SMOKE DETECTOR, VOICE COMMUNICATION, FIRE PROTECTIVE CIRCUIT
- Number of Conductors: 4 #
- Rated Voltage: 0.3 kilovolts
- Operating Temperature: -20 to 75 C
- North American (AWG): 18 AWG
-
Supplier: Carlisle Interconnect Technologies
Description: CarlisleIT has developed the FlightGear™ Smoke Detector Control Panel which provides continuous control of multi-channel fire detection systems in compliance with FAA and OEM Aircraft cabin smoke detection control guidelines. Early detection of smoke and fire threats
- Conventional - Zones / Alarm Points: 2
- Length: 4.36 inch
- Width: 3.24 inch
- Voltage: 28 volts
-
Supplier: AENOR
Description: Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors
-
Supplier: AENOR
Description: Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors
-
Supplier: AENOR
Description: Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors
-
Supplier: AENOR
Description: Fire detection and fire alarm system - Part 31: Multi-sensor fire detectors - Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors
-
Supplier: InfraTec GmbH
Description: As a specialist in flame detection technology the LRM-274 expands the range of detectors, that are characterized by a field of view wider than 90˚. The low-power detector requires only one unipolar supply voltage and is particularly suitable for operation in industrial fire
- Operating Temperature: -13 to 185 F
- Electrical Outputs: Analog Current
- Number of Gases Monitored: Single Gas
-
Supplier: Det-Tronics
Description: See fire, only fire, any fire. So you don’t have to hassle with costly operation shutdowns. And get continuous protection with the quickest detection without worrying about maintenance and failure. The X3301 establishes the global benchmark in multi-fuel fire
- Maximum Response Time: 18 seconds
- Maximum Detector Range (Sensitivity): 210 ft
- Operating Temperature: -40 to 167 F
- Features: Adjustable Time Delay, Automatic Self-test, Explosion Proof, NEMA 4 Rated Enclosure, Other
-
Supplier: Arjay Engineering
Description: Stand alone gas monitoring for commercial and light industrial applications The EC-Gold Dual is ideal for any size facility where one or multiple gases need to be monitored. More than 30 years of gas detection experience has contributed to this highly functional detector. • one or two onboard
- Operating Temperature: -4 to 104 F
- Measurement Type: %Volume, Trace
- Application: Ambient Air Monitoring
- Electrical Outputs: Analog Current
-
Supplier: UL Standards & Engagement
Description: applications; d) Sensors and sensing circuits intended for use with or in gas detectors, alarms or gas detection circuits within fuel cell systems; e) Portable gas detectors; f) Multi-gas gas detectors; g) Multi-gas sensors. 1.3 These requirements also cover all
-
Supplier: Emerson Automation Solutions – Rosemount
Description: to Ultraviolet detector, an Ultraviolet/Infrared detector, or a Multi-spectral Infrared type of flame detector.
-
Supplier: Eagle Eye Power Solutions, LLC
Description: 24VDC N.O. (fire/security) panels. The GD-3000 Includes: GD-3000 Unit User Manual *4 x 4 electric mounting box is not included The GD-3000 gas detector does not require any regular maintenance or service other than cleaning. The unit uses a long life pellistor sensor that has over a
- Operating Temperature: 0 to 125 F
- Operating Humidity: 10 to 90 %
- Measurement Type: %LEL
- Application: Ambient Air Monitoring
-
Description: This book presents a comprehensive introduction to the selection, operation, and testing of infrared devices, including a description of modern detector assemblies and their operation This book discusses how to use and test infrared and visible detectors. The book provides a convenient
-
Supplier: MSA Safety
Description: Outfitted with rapid-response MSA XCell® sensors, the ALTAIR 4XR Gas Detector is the toughest 4-gas monitor on the market and is backed by a 4-year warranty. The ALTAIR 4XR can also provide real-time incident awareness to team members, supervisors, safety managers and others when paired with
- Operating Temperature: -40 to 140 F
- Operating Humidity: 5 to 95 %
- Measurement Type: %LEL, Trace
- Features: Audible or Visual Alarms, Hazardous Environments, Intrinsically Safe
-
Supplier: Emerson Automation Solutions – Rosemount
Description: essential complimentary tool to the self-testing capabilities of your Rosemount™ 975MR Multi-spectrum Infrared flame detector. It brings fire prevention safety to a higher level by giving you the ability to fully test the operational readiness of your entire fire
-
Supplier: ASTM International
Description: 1.1 This standard applies to all hand-worn or glove-type metal detectors used to find metal contraband concealed or hidden on people or other objects with hand-accessible surfaces. Hand-worn metal detectors (HWMDs) are significantly different in design compared to the more common
-
Supplier: ASTM International
Description: 1.1 This standard applies to all hand-worn or glove-type metal detectors used to find metal contraband concealed or hidden on people or other objects with hand-accessible surfaces. Hand-worn metal detectors (HWMDs) are significantly different in design compared to the more common
-
Supplier: UL Standards & Engagement
Description: This standard does not cover the following: a) Smoke detectors of the non-self-contained type that are intended for connection to a household or industrial system control unit. These are included in the Standard for Smoke Detectors for Fire Protective Signaling Systems, UL 268;
Find Suppliers by Category Top
Featured Products Top
-
HTCC (High-Temperature Co-fired Ceramic) multi-layer co-fired ceramic substrate packaging technology provides a reliable solution for high-performance electronics. This advanced technology leverages the superior properties of HTCC materials, including high (read more)
Browse Specialty Ceramics Datasheets for Suntech Applied Materials (Hefei) Co.,Ltd -
multi-channel detectors as well as digital multi-channel detectors (PyrIQ). The detectors are used, for example, in gas analysis, fire and flame sensors and spectroscopy. (read more)
Browse Heat Detectors Datasheets for InfraTec GmbH -
Dexter Research Center, Inc. - Fire Suppression / Detection - Thermopiles from Dexter Research. A variety of products based on yoour specific requirements (8 products): Attributes include: Thin Film vs Silicon, Signal to (read more)
Browse Thermopiles Datasheets for Dexter Research Center, Inc. -
-contact temperature measurement applications such as work piece monitoring in ovens, heat gun target monitoring and fire detection/suppression in extreme environments. A new filter attachment technique provides hermeticity that makes the detector rugged and reliable in hostile environments and eliminates the need for shielding and/or cooling in high temperature applications. (read more)
Browse Noncontact Infrared Temperature Sensors Datasheets for Dexter Research Center, Inc. -
Detectors Gas Analysis Detectors Fire Suppression/Detection Infrared Imaging Products Specialty Products: Thermopile Development Tools, Thermacon Motion Sensors, Integrated (read more)
Browse Datasheets for Dexter Research Center, Inc. -
Multi-Spindle Screwdriver for High-Speed Qualified Assembly Delivering seamless screw rundowns, Visumatic’s automatic screwdriver system comes ready to mount and (read more)
Browse Screwdrivers (electric and pneumatic) Datasheets for Visumatic Industrial Products -
-made components on more than 1.600 m² of clean room space – especially pyroelectrical infrared detectors – for clients worldwide. The product range includes analogue single and multi-channel detectors as well as digital multi-channel detectors (PyrIQ). The detectors are used, for example, in gas analysis, fire and flame sensors and spectroscopy. (read more)
Browse Gas Sensors Datasheets for InfraTec GmbH -
/Detection Detectors Laser Power and Targeting Detectors Gas Analysis Detectors Fire Suppression/Detection Infrared Imaging Products Specialty Products: (read more)
Browse Datasheets for Dexter Research Center, Inc. -
-0.04%/°C. This detector has a very short thermal shock response to ambient temperature change. Applications: Excellent for non-contact temperature, fire suppression, horizon sensor, and gas analysis. Benefit: Low cost and small active area size (read more)
Browse Thermopiles Datasheets for Dexter Research Center, Inc. -
Dexter Research Center,Inc. - Offers extremely high output with best signal-to-noise performance with a time constant of 85ms when encapsulated with Argon gas. Excellent for gas analysis, fire detection and non (read more)
Browse Thermopiles Datasheets for Dexter Research Center, Inc.
More Information Top
-
1999 Index
application to multi sensor detector fire tests, 200- 201 News and Meetings, 90, 186, 362 NFPA, 90-91 web site for Fire Technology, 191 NFPA 70.
-
IMTC 2005 Table of Contents
Thursday, May 19, 2005 YD1: Measurement in Ground Transportation Systems Chair: G. Brasseur, Graz University of Technology, AUSTRIA Co-Chair: F. C. A. Groen, University of Amsterdam, THE NETHERLANDS Fault-Secure Multi - Detector Fire Protection System for Trains .
-
Fire protection system for cargo trains using fuzzy logic
H.H. Amer, and R.M. Daoud, “Fault-secure multi - detector fire protection system for trains,” Accepted for publication, IEEE IMTC05, Ottawa, May 2005.
-
Fault-Secure Multidetector Fire Protection System for Trains
[10] H. H. Amer and R. M. Daoud, “Fault-secure multi - detector fire protection system for trains,” in Proc. IEEE IMTC, Ottawa, ON, Canada, May 2005, pp. 1664–1668.
-
type density tester - offers from type density tester manufacturers, suppliers, exporters & wholesalers
[ Related Keywords : Smoke Detector, smoke alarm, Fire Fighting, Multi detector ] .
-
magnetic compound - offers from magnetic compound manufacturers, suppliers, exporters & wholesalers
[ Related Keywords : Smoke Detector, smoke alarm, Fire Fighting, Multi detector ] .
-
Investigation on light dark matter
6The single-hit events are those events where only one detector of many actually fires in a multi - detectors set-up.
-
http://www.anton-paar.com/corp-en/products/details/pma-5/volatility/?eID=documentsDownload&document=38525&L=0
Product highlights are: `` One-Twist head `` Multi - detector `` Integrated fire -extinguishing device `` Gas and electric ignition `` 1-button operation `` Tray .
-
Physics and Astrophysics with low background scintillators
… only be found in a well-defined low energy range, where DM particles can induce signals; – it must apply just to those events in which only one detector in a multi - detectors set- up actually “ fires ” (single-hit events …
-
ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS PROCEEDINGS OF THE 9TH CONFERENCE
… must only be found in a well-defined low energy range, where Dark Matter particle can induce signals; 5) it must apply to those events in which just one detector in a multi - detector set-up " fires " (single-hit events …
Indicates content that may require registration and/or purchase.