Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Carr Lane Manufacturing Co.
Description: Use to automatically sequence positioning, clamping, and supporting functions as system pressure increases. Sequence Valves prevent fluid flow to a portion of the fixture until a predetermined trigger pressure is achieved (easily adjustable). Use in multiples for multi-stage
- Actuation: Mechanical Device
- Connection: Threaded
- Pressure Rating: 150 to 7500 psi
- Valve Size: 0.2500 inch
-
Supplier: Atos North America
Description: AGIR, AGIS and AGIU are double stage pressure control valves with balanced poppet designed to operate in oil hydraulic systems. AGIR: pressure reducing AGIS: sequence AGIU: unloading In standard versions the piloting pressure of the poppet of the main stage is
- Actuation: Pilot Operated
- Pressure Rating: 5076 psi
- Valve Size: 0.3937 to 1.26 inch
- Valve Type: Control Valves
-
Supplier: Jergens, Inc.
Description: With adjustable opening pressure, Jergens Hydraulic Sequence Valves may be used to control the sequence of work devices in a common circuit. Note(s): Factory adjusted to sequence at 1000 psi.
- Media: Hydraulic Fluid
- Pressure Rating: 5000 psi
-
-
Supplier: Atos North America
Description: HS are direct sequence valves, spool type. KS are double stage sequence valves, spool type. Pressure adjustment is operated by loosening the locking nut and turning the setting screw in the normal model. Valves designed to operate in hydraulic systems with
- Actuation: Manual / Hand
- Pressure Rating: 3046 psi
- Valve Size: 0.2362 to 0.3937 inch
- Valve Type: Pressure Relief Valves, Spool Valves
-
Supplier: Prince Manufacturing Corp.
Description: FUNCTION The PRINCE valve model RD-1000S is an internally piloted adjustable sequence valve. This valve will prevent the flow of oil from going to the sequence port until the pressure on the inlet port reaches the sequence pressure. The sequence
- Actuation: Pilot Operated
- Number of Ports/Ways: 3
- Pressure Rating: 3000 psi
- Valve Size: 0.3750 to 0.5000 inch
-
Supplier: Air Logic
Description: The Valve is designed for precise control in pneumatic control circuits. It can be used as a relay valve to sequence specific signal operations or as a relief valve to limit pressure in a pneumatic system. Fixed or adjustable pressure settings are available; the pressure
- Actuation: Pneumatic
- Connection: Metal Face Seal
- Media Temperature: 40 to 120 F
- Pressure Rating: 30 psi
-
Supplier: Festo Corporation
Description: Control elements with all functions for pneumatic sequence controls For control cabinet installation Fast replacement of components
- Media: Air, Compressed Air
- Media Temperature: 14 to 140 F
- Pressure Rating: 26.11 to 116 psi
- Valve Type: Control Valves
-
Supplier: HydraForce, Inc.
Description: A screw-in, cartridge-style, direct-acting, spool-type, hydraulic sequence valve with internal pilot and spring chamber drain, designed to direct flow to a secondary circuit once a pre-determined pressure level is attained in the primary circuit. The valve will remain shifted
- Actuation: Pilot Operated
- Number of Ports/Ways: 2
- Pressure Rating: 3500 psi
- Valve Size: 0.2500 to 0.3750 inch
-
Supplier: SC Hydraulic Engineering Corporation
Description: The ASV-100-N-050 valve was designed to be plumbed between the air supply FRL assembly and the air drive inlet port on SC 10-4, 10-5 and 10-6 series pumps. The valve is normally closed with a field adjustable opening pressure between 25 psig and 100 psig. The pump cycles only when
- Actuation: Mechanical Device
- Connection: Threaded
- Pressure Rating: 100 psi
- Valve Size: 0.5000 inch
-
Supplier: Vektek, LLC
Description: eliminates need for third fluid line to drain bypass flow (internal leakage) back to system reservoir. True sequence design allows full system pressure downstream of valve after opening. Manifold Mountable.
- Actuation: Manual / Hand
- Number of Ports/Ways: 2
- Pressure Rating: 500 to 5000 psi
-
Supplier: HydraForce, Inc.
Description: A screw-in, cartridge-style, direct-acting, spool-type, hydraulic sequence valve with external pilot and internal spring chamber drain.
- Actuation: Pilot Operated
- Number of Ports/Ways: 2
- Pressure Rating: 3500 psi
- Valve Size: 0.3750 inch
-
Supplier: HydraForce, Inc.
Description: A screw-in, cartridge-style, pilot-operated, spool-type, hydraulic sequence valve with internal pilot and external spring chamber drain.
- Actuation: Pilot Operated
- Number of Ports/Ways: 2
- Pressure Rating: 3500 psi
- Valve Size: 0.2500 to 0.3750 inch
-
Supplier: HydraForce, Inc.
Description: A screw-in, cartridge-style, direct-acting, spool-type, hydraulic sequence valve with internal pilot and spring chamber drain.
- Actuation: Pilot Operated
- Number of Ports/Ways: 2
- Pressure Rating: 3500 psi
- Valve Type: Cartridge / Manifold Valves
-
Description: Hydraulic fluid power -- Pressure-reducing valves, sequence valves, unloading valves, throttle valves and check valves -- Mounting surfaces
-
Supplier: Vektek, LLC
Description: eliminates need for third fluid line to drain bypass flow (internal leakage) back to system reservoir. True sequence design allows full system pressure downstream of valve after opening. Manifold Mountable.
- Actuation: Manual / Hand
- Number of Ports/Ways: 2
- Pressure Rating: 500 to 5000 psi
-
Supplier: Accuris
Description: Hydraulic fluid power - Pressure-reducing valves, sequence valves, unloading valves, throttle valves and check valves - Mounting surfaces
-
Supplier: Accuris
Description: Hydraulic Fluid Power - Pressure Reducing Valves, Sequence Valves, Unloading Valves, Throttle Valves and Check Valves - Mounting Surfaces
-
Supplier: CSA Group
Description: ISO 5781:2016 specifies the dimensions and other data relating to surfaces on which hydraulic pressure-reducing valves, sequence valves, unloading valves, throttle valves and check valves are mounted in order to ensure interchangeability. It applies to
-
Supplier: Accuris
Description: Hydraulic Fluid Power Valve Mounting Surfaces Part 6: Pressure-Control Valves (Excluding Pressure-Relief Valves), Sequence Valves, Unloading Valves, Throttle Valves and Check Valves
-
Supplier: DigiKey
Description: PRESSURE SEQUENCE VALVE
- Pressure Rating: 26 to 116 psi
- Valve Type: Control Valves, Other
-
Supplier: Radwell International
Description: DIRECT PRESSURE CONTROL VALVES (SEQUENCE, COUNTERBALANCE, RELIEF, UNLOAD VALVES). FREE 2 YEAR RADWELL WARRANTY
- Valve Type: Control Valves, Pressure Relief Valves, Vacuum Relief / Anti-siphon Valves
-
Supplier: Doering Company
Description: The Doering PAV Series valve provides an interface between Hydraulic or High Pressure (up to 5000 PSI) pilot signal and low pressure 0-150 PSI pneumatic directional control. The PAV Series valves are available with crack pressure ranging from 50 PSI to 2,000 PSI. High Pressure Pilot
- Valve Type: Safety Valves
-
Supplier: Radwell International
Description: SOLENOID VALVE, 1800 SERIES, 4-WAY, SINGLE OPERATOR, SINGLE PRESSURE, INDIVIDUAL EXTERNAL PILOT, 1/4 INCH NPTF, PILOT SEQUENCE. FREE 2 YEAR RADWELL WARRANTY
- Valve Type: Pilot Valves, Solenoid Valves
-
Supplier: Radwell International
Description: SOLENOID VALVE, 1800 SERIES, 4-WAY, DOUBLE OPERATOR, PILOT SEQUENCE, SINGLE PRESSURE, INDIVIDUAL EXTERNAL PILOT, 1/4 INCH NPTF, PILOT (2 POSITION). FREE 2 YEAR RADWELL WARRANTY
- Valve Type: Pilot Valves, Solenoid Valves
-
Supplier: Radwell International
Description: PRESSURE SEQUENCE CONTROL VALVE, ADJUSTABLE PRESSURE RANGE: FROM 0 TO 4000 PSI, 5000 PSI OPERATING, 4200 PSI MAX. SEQ.. FREE 2 YEAR RADWELL WARRANTY
- Valve Type: Control Valves
-
Supplier: DigiKey
Description: Sequencer Sub-Base Mount
- Pressure Rating: 30 to 116 psi
-
Supplier: DigiKey
Description: Sequencer Sub-Base Mount
- Pressure Rating: 30 to 116 psi
-
Supplier: Quarktwin Technology Ltd.
Description: Sequencer Sub-Base Mount
- Media Temperature: 23 to 122 F
- Pressure Rating: 30 to 116 psi
- Valve Size: 0.1060 inch
-
Supplier: Quarktwin Technology Ltd.
Description: Sequencer Sub-Base Mount
- Media Temperature: 23 to 122 F
- Pressure Rating: 30 to 116 psi
- Valve Size: 0.1060 inch
-
Supplier: Quarktwin Technology Ltd.
Description: Sequencer Sub-Base Mount
- Media Temperature: 23 to 122 F
- Pressure Rating: 30 to 116 psi
- Valve Size: 0.1060 inch
-
Supplier: Atos North America
Description: AGIR, AGIS and AGIU are double stage pressure control valves with balanced poppet designed to operate in oil hydraulic systems. AGIR: pressure reducing AGIS: sequence AGIU: unloading In standard versions the piloting pressure of the poppet of the main stage is
- Actuation: Pilot Operated
- Pressure Rating: 5076 psi
- Valve Size: 0.3937 to 1.26 inch
- Valve Type: Control Valves
-
Supplier: Atos North America
Description: AGIR, AGIS and AGIU are double stage pressure control valves with balanced poppet designed to operate in oil hydraulic systems. AGIR: pressure reducing AGIS: sequence AGIU: unloading In standard versions the piloting pressure of the poppet of the main stage is
- Actuation: Pilot Operated
- Pressure Rating: 5076 psi
- Valve Size: 0.3937 to 1.26 inch
- Valve Type: Control Valves
-
Supplier: HAWE North America Inc.
Description: screw-in check valves type RC may be installed in both directions with the spring loaded valve shim enabling rapid switching sequences. There are also versions available featuring metric thread or a housing. The screw-in check valves type RE is a shim type check
- Actuation: Mechanical Device
- Number of Ports/Ways: 2
- Pressure Rating: 5802 to 7252 psi
- Valve Type: Check Valves
-
Supplier: Stucchi Inc.
Description: The VU series check valves are used in any type of hydraulic circuit, with a safe, compact design suitable to any hydraulic application using non-corrosive liquids. The VU size range includes two different standard openings at 5 to 65 psi. The VU series can also be used as a pressure
- Actuation: Mechanical Device
- Number of Ports/Ways: 1
- Valve Size: 0.2500 to 2 inch
- Valve Type: Check Valves
-
Supplier: Stucchi Inc.
Description: The VUX series check valves are used in any type of hydraulic circuit, with a safe, compact design suitable to any hydraulic application using non-corrosive liquids. The VUX size range is offered at a standard opening of 7.5 psi. The VUX series can also be used as a pressure sequence
- Actuation: Mechanical Device
- Number of Ports/Ways: 1
- Valve Size: 0.2500 to 1.5 inch
- Valve Type: Check Valves
-
Supplier: Stucchi Inc.
Description: The VUZ series check valves are used in any type of hydraulic circuit, with a safe, compact design suitable to any hydraulic application using non-corrosive liquids. The VU size range includes two different standard openings at 5 to 65 psi. The VU series can also be used as a pressure
- Actuation: Mechanical Device
- Number of Ports/Ways: 1
- Valve Size: 0.1250 to 2 inch
- Valve Type: Check Valves
-
Supplier: Bijur Delimon International
Description: can double volume discharge where needed. Operation Each divider valve has a number of pistons that divide the volume of lubricant equally and forces it out of the valve. When the system is pressurized, pistons are positively displaced in sequence until the cycle is complete,
- Actuation: Mechanical Device, Electric
- Media: Other
- Number of Ports/Ways: 4 to 12
- Pressure Rating: 870 to 2175 psi
-
Supplier: FineTek
Description: The BRD/BDV series are used specifically as dust collector valves in dust collector systems. Each valve consists of two air chambers divided by a diaphragm. The two models, BRD and BDV, perform the same function with slightly different designs. They are used to provide a sudden burst
- Valve Type: Diaphragm Valves, Pilot Valves, Solenoid Valves
-
Supplier: Festo Corporation
Description: Control elements with all functions for pneumatic sequence controls For control cabinet installation Fast replacement of components
- Media Temperature: 14 to 140 F
- Pressure Rating: 43.51 to 116 psi
- Valve Type: Solenoid Valves
-
Supplier: Festo Corporation
Description: Control elements with all functions for pneumatic sequence controls For control cabinet installation Fast replacement of components
- Media Temperature: 32 to 140 F
- Pressure Rating: 29.01 to 116 psi
- Valve Type: Solenoid Valves
-
Supplier: Festo Corporation
Description: Control elements with all functions for pneumatic sequence controls For control cabinet installation Fast replacement of components
- Media Temperature: 14 to 140 F
- Pressure Rating: 0.0 to 116 psi
- Valve Type: Solenoid Valves
-
Supplier: DeZURIK, Inc.
Description: The DeZURIK ECB Pump & Control Valve Interface is designed to provide control between the pump and pump control valve to minimize pressure surges in the system when the pump starts and stops. The pre-programmed controller properly sequences and controls the pump and pump control
- Valve Type: Control Valves
-
Supplier: SC Hydraulic Engineering Corporation
Description: to control automatic "turn on" and "shut off" of a gas booster or pump system and are used in conjunction with a remote pilot on the booster or pump. Other typical applications are for valve actuation, pneumatic alarm systems, or to sequence another system operation after a certain
- Actuation: Pneumatic
- Connection: Threaded
- Flow (Cv): 0.1300 to 0.2000
- Pressure Rating: 3000 to 20000 psi
-
Supplier: ASTM International
Description: . Such oils include both single-viscosity and multiviscosity grade oils that are used in both spark-ignition, gasoline-fueled engines, as well as in diesel engines. 1.1.1 Additionally, with nonmandatory supplemental requirements, a Sequence IIIHA Test (Mini Rotary Viscometer and Cold Cranking
-
Supplier: ASTM International
Description: . Such oils include both single-viscosity and multiviscosity grade oils that are used in both spark-ignition, gasoline-fueled engines, as well as in diesel engines. 1.1.1 Additionally, with nonmandatory supplemental requirements, a Sequence IIIHA Test (Mini Rotary Viscometer and Cold Cranking
-
Supplier: Vektek, LLC
Description: Sealed pilot piston eliminates cross circuit leakage. 5:1 Ratio of Pilot to Check pressure for release. Filters on each port. Unclamp device sequencer, provides a way to sequence single circuit unclamp timing. Requires "B" pilot line to open "A" line
- Actuation: Pilot Operated
- Number of Ports/Ways: 3
- Pressure Rating: 5000 psi
- Valve Type: Check Valves
-
Supplier: ASTM International
Description: 1.1 This test method measures the ability of crankcase oil to control camshaft lobe wear for spark-ignition engines equipped with an overhead valve-train and sliding cam followers. This test method is designed to simulate extended engine idling vehicle operation. The Sequence IVA Test
-
Supplier: ASTM International
Description: 1.1 This test method measures the ability of crankcase oil to control camshaft lobe wear for spark-ignition engines equipped with an overhead valve-train and sliding cam followers. This test method is designed to simulate extended engine idling vehicle operation. The Sequence IVA Test
Find Suppliers by Category Top
Featured Products Top
-
automated so that the sequence happens with little or no manual input. Using limit switches or relays allows a whole series of events to occur based on a preceding event. Remote Locations: Valves which are some distance away from the operator who must cycle (read more)
Browse Ball Valves Datasheets for DynaQuip Controls -
Echelon network that takes advantage of free topology architecture to make network wiring easy. The UC700 utilizes block-style no-code programming for custom control or monitoring sequences. Windows PC-based software has simple point & click navigation with fully customizable screens for (read more)
Browse HVAC Controllers Datasheets for Parker Sporlan Division -
Multiple loads in one with ranges for voltage, current, resistance, and power Intuitive Front Panel Control: Run sequences, triggers, constant current to constant power cross over Closed-case Calibration Individual FET Protection Standard LabWindows and Lab (read more)
Browse Programmable Power Supplies Datasheets for AMETEK Programmable Power -
required (demand side) as well as the exact airflow required in each aeration zone (supply side) to maintain the DO at the set point. AERprocess then sequences the blowers and accurately adjusts the valves to distribute the airflow as required. AERprocess measures the DO in each control basin, and (read more)
Browse Fans and Blowers (industrial) Datasheets for Aerzen USA Corp. -
applications, surface roughness can directly impact the lifespan and reliability of the part. For example, rougher surfaces can compromise the sealing effectiveness in components that need to retain fluids or gases, like valves or seals, which may lead to leaks. Roughness also concentrates stress in (read more)
Conduct Research Top
-
Different Types of Pressure Control Valves
, reducing, sequence, counterbalance, safety, and unloading. All of them are typically closed valves, except for reducing valves, which are usually open. For most of these valves, a restriction is necessary to produce the required pressure control. One exception is the externally piloted unloading valve
-
Printed Circuit Board Rinse Water Circulation
Problem: The rinse water control was controlled by manually operating valves installed in the main and by-pass lines. Valve adjustments were required as the tank water level varied or the tank water was changed. If the operator incorrectly adjusted or sequenced the adjustment of the valves
More Information Top
-
Bookshelf and Unified Agenda > Independent Agencies / Commissions > Nuclear Regulatory Commission > NUREG Series Publications > NUREG-0933 - A Prioritization o...
Further, a more careful analysis that includes additional sequences ( valve faults, etc.) may show greater (or lesser) ESW plant-specific vulnerabilities and public risk.
-
https://customer.honeywell.com/resources/techlit/TechLitDocuments/77-0000s/77-E1100.pdf
This system requires special three-way sequencing valves that shut off all flow at the middle of the thermostat throttling range.
-
Fluid Power Engineering > Hydraulic Control Valves
• Sequence valves (direct- and pilot-operated .
-
Hydraulic BOP Controls for Deepwater Operation
This concern was avoided by isolating the SPM valve from the bias pressure, by use of a sequencing valve especially designed for a Pressure Bias System.
-
http://content.onlinejacc.org/data/Journals/JAC/22830/0233Q.pdf?resultClick=1
prolonged. whereas the tricuspid valve closttro interval was significantly shorter in the re- versed sequence group than in those with normally se- quenced valve closure.
-
Machine Tools Handbook: Design and Operation > MACHINE TOOL OPERATION
When the system pressure reaches the intensity set on the sequence valve , the valve connects the pressurized oil supply to the closed end of the big cylinder.
-
Subsea Production Control: Beryl Field
Each of the sequence valves located in the pod are configured .
Indicates content that may require registration and/or purchase.