Supplier: Chevron Lubricants
Description: Chevron HTF E-100 is an exceptional quality single phase, ethylene glycol concentrate used in heat transfer applications or as an industrial coolant/antifreeze product. It is a readily biodegradable, silicate free coolant designed to minimize deposits that could reduce heat
- Applications & Features: Process Equipment, Biodegradable
- Chemistry / Constituents: Synthetic / Semi-synthetic, Polyglycol / Water-Glycol
- Type / Function: Circulating Coolant (Anti-freeze / Secondary Refrigerant)
-
Supplier: Chevron Lubricants
Description: HDAX Prediluted 50/50 Coolant/Antifreeze Phosphate Free is a single phase, ethylene glycol-based coolant/antifreeze designed for use in stationary natural gas engines and in heavy duty on-highway and off-highway diesel engines. It uses a low silicate technology plus a complete
- Applications: Automotive / Transportation, Combustion Engines
- Chemistry / Constituents: Polyglycol / Water-Glycol
- Composition / Chemistry: Synthetic / Semi-synthetic
-
Supplier: Chevron Lubricants
Description: Chevron HTF P-150 is an inhibited propylene glycol used as a heavy duty industrial coolant and heat transfer agent. The inhibitor system is designed to protect brass, copper, solder, steel, cast iron, aluminum, and other metals commonly found in industrial cooling and heating systems.
- Applications & Features: Process Equipment, Automotive / Transportation, Combustion Engines, Compressors / Piston Pumps, Low / Non-foaming
- Chemistry / Constituents: Synthetic / Semi-synthetic, Polyglycol / Water-Glycol
- Type / Function: Circulating Coolant (Anti-freeze / Secondary Refrigerant)
-
-
Supplier: SAE International
Description: This standard covers glycol-type compounds which, when added to engine cooling systems at concentrations of 50 - 70% by volume of coolant concentrate in water, provide corrosion protection, lower the freezing point, and raise the boiling point of the coolant. Such
-
Supplier: SAE International
Description: This SAE Standard covers reinforced and flexible hoses intended for use in water and ethylene glycol-based engine-coolant system applications.
-
Supplier: SAE International
Description: This SAE Standard covers reinforced and flexible hoses intended for use in water and ethylene glycol-based engine-coolant system applications.
-
Supplier: SAE International
Description: This standard covers glycol-type compounds which, when added to engine cooling systems at concentrations of 40-70% by volume of coolant concentrate in water, provide corrosion protection, lower the freezing point, and raise the boiling point of the coolant. Such compounds
-
Supplier: Xoxide
Description: Recommended for Swiftech and all other brands of liquid cooled products. HydrX prohibits oxidation, formation of algae, and improves heat transfer. UV sensitivity makes this a great addition to any show piece computer case. Specifications: Mixing Ratio: Mix 1 bottle to 1 liter (33 Oz) of distilled
-
Supplier: Xoxide
Description: Now you too can own 1000cc of one of the most poisonous watercooling coolants on the market! Introducing the Coolant 1000 from Thermaltake! This toxic concoction will be the bane of your computer’s heat’s existence delivering anti-freezing, anti-corrosive, anti-evaporation, and
-
Supplier: Xoxide
Description: cleanest of clean, containing an extremely low viscosity and chemical makeup...the ultimate in superior PC water cooling coolant. Features: Contains no Glycols...just pure, unadulterated PERFORMANCE Completely Safe w/ All Plastics, Rubbers, and Mis. Gasket Materials
-
Supplier: Xoxide
Description: Replacement coolant for the Thermaltake Bigwater, Aquarius Series, and any liquid water cooling system. Please follow all Waring labels! As per manufacturer’s instructions, it is absolutely imperative that you Do Not Drink this product! If you looking for cooled fitting
-
Supplier: Duratherm Extended Life Fluids
Description: resist the degrading effects of boiling more efficiently than more common petroleum based glycols. Intercool Biogreen is available in several concentrations (that can be diluted with de-ionized water) for custom freeze point suppression and offer less maintenance requirements through
-
Supplier: ASTM International
Description: This specification establishes the testing and requirements of four types of engine coolant grade ethylene glycol and propylene glycol, including virgin glycols and those derived from the recycling of vehicle engine coolants and industrial source glycols.
-
Supplier: ASTM International
Description: This specification establishes the testing and requirements of four types of engine coolant grade ethylene glycol and propylene glycol, including virgin glycols and those derived from the recycling of vehicle engine coolants and industrial source glycols.
-
Supplier: ASTM International
Description: This specification covers the requirements for low silicate ethylene glycol base engine coolants for cooling systems of heavy-duty engines. Such engines are typically used in off-highway machinery for agriculture, mining, earth-moving, and construction; Class 5 to 8 over the road
-
Supplier: ASTM International
Description: 1.1 This specification covers the requirements for ethylene glycol or propylene glycol base engine coolants used in automobiles or other light duty service cooling systems. When concentrates are used at 40 to 70 % concentration by volume in water, or when prediluted
-
Supplier: Duratherm Extended Life Fluids
Description: INTERCOOL P-300 is a propylene glycol based industrially inhibited heat transfer fluid with an operating range of -60°F to 320°F engineered for applications that demand a low-toxicity fluid to satisfy environmental concerns and where propylene glycol use is demanded by law
-
Supplier: Duratherm Extended Life Fluids
Description: INTERCOOL OP-100 is an ethylene glycol based industrially inhibited heat transfer fluid optimal for freeze point suppression and single fluid heating and cooling applications with an operating range of -60°F to 350°F. Industrial Inhibitors Intercool OP
-
Supplier: Hubbard-Hall Inc.
Description: Product Information DOWFROST HD heat transfer fluid is a formulation of 94.0 percent propylene glycol and a specially designed package of industrial corrosion inhibitors. The fluid is dyed bright yellow to aid in leak detection. Solutions in water provide freeze protection to
- Applications & Features: Process Equipment, Biodegradable, Specialty
- Chemistry / Constituents: Synthetic / Semi-synthetic, Polyglycol / Water-Glycol
- Flash Point: 219 F
- Type / Function: Circulating Coolant (Anti-freeze / Secondary Refrigerant)
-
Supplier: Hubbard-Hall Inc.
Description: Product Information DOWFROST is a propylene glycol-based fluid that contains a specially formulated package of industrial inhibitors that help prevent corrosion. Because propylene glycol fluids have low acute oral toxicity, DOWFROST is often used in applications where contact with
- Applications & Features: Process Equipment, Biodegradable, Specialty
- Chemistry / Constituents: Synthetic / Semi-synthetic, Polyglycol / Water-Glycol
- Flash Point: 219 F
- Type / Function: Circulating Coolant (Anti-freeze / Secondary Refrigerant)
-
Supplier: Hubbard-Hall Inc.
Description: Product Information DOWTHERM SR 1 is an ethylene glycol-based fluid that is widely used for secondary cooling and heating applications, for freeze and burst protection of pipes, and for various deicing, defrosting, and dehumidifying applications. DOWTHERM SR 1 contains a specially
- Applications & Features: Process Equipment, Biodegradable, Specialty
- Chemistry / Constituents: Synthetic / Semi-synthetic, Polyglycol / Water-Glycol
- Flash Point: 260 F
- Type / Function: Circulating Coolant (Anti-freeze / Secondary Refrigerant)
-
Supplier: Red Line Synthetic Oil Corporation
Description: Convenient, pre-mixed coolant for motorcycles, ATVs, karts, etc.-pour and go! Blended with purified, deionized water and proper WaterWetter percentage Reduces rust, corrosion and electrolysis, cleans and lubricates water pump seals Compatible with all antifreeze and
- Type / Function: Circulating Coolant (Anti-freeze / Secondary Refrigerant)
-
Supplier: Heat Exchange & Transfer, Inc.
Description: Model WC250-9-121 Seal Cooling System eliminates the need for a separate supply of cooling water to high temperature process pump cooling circuit. The package circulates a cooling fluid (water/glycol mixture) in a closed loop to the pump’s seal cooling cavity. The WC250-9-121 can be
- Connection Size: 0.5000 inch
- Cooling Capacity: 30000 BTU/hr
- Fluid Transfer Specifications: Heating and Cooling
- Heat Source: Electric
-
Supplier: Houghton International, Inc.
Description: Aqua-Quench® 260 is a concentrated aqueous solution of polyalkylene glycol which has inverse solubility in water. It is oil-free, nonflammable and provides controlled cooling rates which reduce the distortion problems normally associated with water quenched aluminum.
- Chemistry / Constituents: Water Soluble / Emulsion
- Function / Application: Quenchant / Heat Treat, Specialty / Other
- Industry & Features: Specialty
-
Supplier: Hammond Manufacturing Company Inc.
Description: Features Compatible with chilled water/glycol, tower water and other circulated coolants Integrated thermostat & solenoid value with alarm contact provides automatic temperature control Rugged (10 bar) copper tube / aluminum fin heat exchanger
-
Supplier: Badger Meter
Description: The Hedland® water-based fluid meter is designed to monitor fluid flow rates of water and oil emulsions, including glycol mixtures, water-in-oil, glycerin and other various coolants. Meter Flexibility. Accurate Fluid Monitoring. The Hedland water-based fluid
- Gas Volumetric Flow Rate: 0.0027 to 40.11 SCFM
- Liquid Volumetric Flow Rate: 0.0200 to 300 GPM
- Mass Flow Rate Range: 4.41E-5 to 0.6615 lbs/min
- Operating Temperature: -20 to 240 F
-
Supplier: OMEGA Engineering, Inc.
Description: not include long fibers or a significant level of abrasive solids. Typical applications will be for cooling loops using water or 50% glycols, and water soluble machine coolant (up to 10%). These applications are found in most process industries, including rubber, steel,
- Liquid Volumetric Flow Rate: 0.4000 to 200 GPM
- Electrical Output: Analog Current
- End Fittings: Threaded
- Features: Measures Temperature, Audible or Visual Alarms
-
Supplier: Red Line Synthetic Oil Corporation
Description: that form on hot metal surfaces to reduce coolant temperatures by up to 20° Superior heat transfer properties compared to glycol-based antifreeze Compatible with new or used antifreeze (including DEX-COOL and long-life versions) to improve the heat transfer of ethylene and
-
Supplier: ifm electronic gmbh
Description: Precise detection of flow in pipes Suitable for water, coolants, oil and glycol solutions Precise linearized analogue output Robust housing with very high pressure rating Very fast response time (~10 ms)
- Gas Volumetric Flow Rate: 0.2472 to 12.36 SCFM
- Media Temperature Range: 14 to 212 F
- Operating Pressure: 363 psi
- Operating Temperature: 32 to 140 F
-
Supplier: ifm electronic gmbh
Description: Precise detection of flow in pipes Suitable for water, coolants, oil and glycol solutions Precise linearized analogue output Robust housing with very high pressure rating Very fast response time (~10 ms) Please note the changed housing design!
- End Fittings: Threaded
- Media Temperature Range: 14 to 212 F
- Operating Pressure: 580 psi
- Operating Temperature: 32 to 140 F
-
Supplier: ifm electronic gmbh
Description: Precise detection of flow in pipes Suitable for water, coolants, oil and glycol solutions Precise linearized analogue output Robust housing with very high pressure rating Very fast response time (~10 ms) Please note the changed housing design!
- Gas Volumetric Flow Rate: 0.1412 to 3.53 SCFM
- End Fittings: Threaded
- Media Temperature Range: 14 to 212 F
- Operating Pressure: 363 psi
-
Supplier: ThermOmegaTech®
Description: body, fittings, spring and plug Ram-type plug for tight reliable shutoff Operates in narrow temperature band Easy to install Typical Applications The TV/HAT-RA reverse acting valve may be used to regulate the flow of cooling water, glycol or other
- Actuation: Thermally Actuated
- Connection: Tube Fitting
- Media Description: Water (General)
- Media Temperature: 150 F
-
Description: Working temperature range: -40?~+85??Medium:Hot air or refrigerant (ethylene glycol and water 50% each) hydrogen ?Material and structure options: 1. VMQ + PET/Nomex/Aramid+VMQ Inner VMQ is food grade silicone, vulcanized by platinum
- Application: General-Purpose / Fluid Handling, Agricultural, Aviation / Aerospace, Automotive, Cryogenic, Food and Beverage Processing, HVAC, Hydraulics, Marine, Pneumatic, Sanitary, Suction / Vacuum, Other
- Construction Options: Coiled, Corrugated, Articulated, Crush Proof, Reinforced
- Features: Anti-static, Flame Resistant
- Material: Elastomers, Fluoropolymers / Silicone, Metal, Other
-
Supplier: CSA Group
Description: is the refrigerant and lithium bromide is the absorbent); and (c) positive displacement chillers using fluids with secondary coolants (glycol or brine) for freeze protection and leaving brine temperatures greater than 0 °C (32°F). 1.5 This Standard does not apply to (a) absorption
-
Supplier: Radwell International
Description: FLOW METER WITH INTEGRATED BACKFLOW PREVENTION AND DISPLAY, PRECISE DETECTION OF FLOW AND MEDIUM TEMPERATURE SUITABLE FOR WATER, COOLANTS, OIL AND GLYCOL SOLUTIONS THANKS TO INTEGRATED MEASUREMENT GRAPHS RELIABLE BACKFLOW PREVENTION WITH VERY FAST RESPONS. FREE 2 YEAR RADWELL
Find Suppliers by Category Top
Featured Products Top
-
water. Fill the bucket up the rest of the way with water. Fill your machine. Once you have your mixed coolant, fill your machine accordingly. Remember that over time, as water evaporates from your (read more)
Browse Metalworking Lubricants, Coolants, and Fluids Datasheets for QualiChem, Inc. -
Refractometers are one of the most basic tools to measure water-diluted metalworking fluids' concentration. Learn from this step-by-step guide for calibrating and using an analog and digital refractometer. (read more)
Browse Metalworking Lubricants, Coolants, and Fluids Datasheets for QualiChem, Inc. -
Filtertech has a wide range of filtration and swarf management equipment for the lens generating / optical industry. From generating lenses to treating hazardous waste water, filtertech has the solution. Learn more. (read more)
Browse Coolant Recycling Systems Datasheets for Filtertech, Inc. -
QualiChem, Inc. manufactures some of the most advanced metalworking fluids available in the world. As a global supplier, our fluids meet all of the relevant health & safety regulations, including GHS and REACH. Our product line includes water (read more)
Browse Metalworking Lubricants, Coolants, and Fluids Datasheets for QualiChem, Inc. -
address the industry’s recurring pain points—heat buildup, coolant blockage, and system downtime—the EDH Series integrates a micron-level filtration system and a parallel water circuit (read more)
Browse Shock and Vibration Testing Shakers Datasheets for ECON Technologies Co.,Ltd -
address the industry’s recurring pain points—heat buildup, coolant blockage, and system downtime—the EDH Series integrates a micron-level filtration system and a parallel water circuit (read more)
Browse Shock and Vibration Testing Shakers Datasheets for ECON Technologies Co.,Ltd -
high-precision flow and temperature measurement, as well as totalized flow consumption for water and water/glycol applications. ifm's SA flow sensors is a cost effective, probe style flow sensor that can measure flow and temperature in pipes from ½” to 16” (read more)
Browse Liquid Flow Meters Datasheets for ifm efector inc. -
liquid: DI water, ultrapure water, ethylene glycol, polypropylene glycol, and PFPE Color coding options: Input: Blue Output: Red High flow and no spillage 5000 durability cycles (read more)
Browse Electrical Connectors Datasheets for DigiKey -
finished lubricants (engine oil, hydraulic fluid, gear oil). Process Streams: Filtering crude oil fractions, solvents, additives, glycols. Hydraulic Systems: Protecting hydraulic fluid in machinery. Metalworking & Coolants: (read more)
Browse Filter Elements Datasheets for Harbory Filtration -
excessive heat or usage. Contamination - common contaminants include water, sand and dirt. Sometimes coolant can end up in transmission fluids, particularly if there is an intercooler present. Recommended Tests Ferrous wear - wear in transmissions can often be (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific
More Information Top
-
Proceedings of the 11th European Conference on Thermoelectrics
The gas (dry air) inlet temperature was 320 °C and the coolant ( water glycol mixture) temperature was 40 °C.
-
Battery Thermal Management System Design Modeling
Note that 0.7 mm jacket wall thickness and 0.05 mm air layer were considered between cell surface and water / glycol coolant channel.
-
Fan and Heat Exchanger Flow Interactions
Figures 28 and 29 show the mass flow rate and heat rejection for the standard 5 cm push, CR1, and segregated pusher modes for water / glycol coolant .
-
Assessment of Thermal Control Technologies for Cooling Electric Vehicle Power Electronics
The current approach for cooling hybrid electric power inverters uses a separate cooling loop with water ethylene glycol coolant at approximately 70°C.
-
http://www.dtic.mil/cgi-bin/GetTRDoc?AD=ADA431752&Location=U2&doc=GetTRDoc.pdf
Mapping of Low-Grade Heat Exchanger (HEX 880) with Water / Glycol Coolant when High-Grade Heat Exchanger (HEX 490) is in use .
-
How Apollo Flew to the Moon
Whereas the CSM used radiators and evaporators to lose heat from a water / glycol coolant , the LM relied on a sublimator to achieve the same task.
-
How Apollo Flew to the Moon
Whereas the CSM used radiators and evaporators to lose heat from a water / glycol coolant , the LM relied on a sublimator.
-
Countdown to a Moon Launch
Gaseous oxygen and hydro- gen lines were connected to power the fuel cells, and the water / glycol coolant in the ECS was flushed and exchanged.
-
High Voltage Engineering Testing
… materials used for each individual component is satisfactory in terms of compatibility with all the other materials in the system and to survive for the life of the scheme in the environment of the pure demineralised water or water / glycol coolant .
-
Apollo 12 - On the Ocean of Storms
A water - glycol coolant system had controlled the command module's temperature throughout the flight by using radiators on the service module for heat rejection, but the service module had to be jettisoned prior to entry.