Analog Voltage Turbine Flow Meters
from Aichi Tokei Denki Co., Ltd.
Feature. ・ Superior repeatability ・ Low pressure drop ・ Output of pulses proportional to flow-rate with the amplifier-built-in magnetic sensor which is strong against electrical noises ・ Simple structure ・ Free installation position ・ Small and light weight. [See More]
- Electrical Output: Voltage
- Operating Pressure: 0.0 to 109
- Process Media Type: Liquid
- Meter Type: Volumetric Flow Meter
from Aichi Tokei Denki Co., Ltd.
Feature. ・Built-in lithium batteries (No external power supply is required) ・Indications of both instantaneous flow-rate and integrating flow volume by only 1 flowmeter ・Revolving display unit (It can be fixed to a easy-to-read position) ・Simplified structure with the... [See More]
- Electrical Output: Current; Voltage
- Operating Pressure: 145
- Process Media Type: Liquid
- Media Temperature: 32 to 140
from Spirax-Sarco
The RIM10 rotor insertion flowmeter utilizes multi-variable electronics to provide a compensated mass flowrate of liquid, gas and steam from a single opening in the pipeline. The RIM10 measures all process variables with a single device providing outstanding accuracy and reduces installation costs. [See More]
- Electrical Output: Current; Voltage
- Mounting: Insertion
- Pipe Diameter: 3.00 to 80.00
- End Fittings: In-line Flanged
from Clark Solutions
CFR0 flow transmitters combine visual confirmation of flow with a pulse or conditioned 0-10 V output proportional to flow rate. As liquid passes through the meter body, a magnetic rotor spins at a rate proportional to flow. This causes a series of magnetic fields (the rotor vanes) to excite a hall... [See More]
- Electrical Output: Voltage
- Mounting: In-line
- Pipe Diameter: 0.25
- End Fittings: In-line Threaded
from Burger & Brown Engineering, Inc.
Tracer Electronic Switching Flowmeter measures liquid flow rate and temperature while providing a selectable analog signal and programmable switch for low or high flow and temperature. 8 to 28VDC power source operates the flowmeter. Sealed pushbuttons configure the flowmeter and switching operations... [See More]
- Electrical Output: Switch; Voltage
- Mounting: In-line
- Pipe Diameter: 0.38 to 3.00
- End Fittings: In-line Threaded
from Malema Sensors
Malema's TM44 series turbine flow meter is used in precise measurement of clean fluid flow. The TM44 can be supplied as a basic sensor with a pulse output or a 4-20mA output. Alternatively, a number of electronic units are available to provide batch control, totalization and a display of... [See More]
- Electrical Output: Voltage
- End Fittings: In-line Flanged
- Mounting: In-line
- Process Media Type: Liquid
from Flow Technology, Inc.
High shock load applications. HS Series “high shock ” turbine flowmeters are specifically designed to withstand pressure spikes that create hydraulic shock waves in fluids when actuators or rams are activated. This water hammer effect can dislodge the internals or sheer rotor blades off... [See More]
- Electrical Output: Voltage
- End Fittings: In-line Flanged; In-line Threaded; AN (or MS) External Straight Threads, 37° Flare, NPT External Threads, Dynamic Beam Seal, per SAE AS 85720/01, SAE Code 62, 4-bolt Split Flange
- Mounting: In-line
- Process Media Type: Liquid
from Litre Meter Limited
Extended linearity electromagnetic flowmeter with PTFE liner designed for wafer fitting between flanges. 25mm to 300mm [See More]
- Electrical Output: Current; Frequency; Switch; Voltage
- Mounting: In-line
- Pipe Diameter: 0.98 to 11.81
- End Fittings: In-line Flanged
from Hoffer Flow Controls, Inc.
The Hoffer Teflon Series Turbine Flowmeters are designed and manufactured for process chemical and corrosive service flow measurement. The Teflon meter is selected when chemical compatibility is critical in the flow application. OUTSTANDING FEATURES. Recommended for corrosive service and ultrapure... [See More]
- Electrical Output: Frequency; Voltage
- Mounting: In-line
- Pipe Diameter: 0.25 to 3.00
- End Fittings: In-line Flanged (optional feature); In-line Threaded (optional feature); RF per ANSI and DIN types
from OMEGA Engineering, Inc.
FLR1000 Series flow sensors can measure extremely low flow rates from 20 mL/min to 500 L/min. These sensors are suitable for a wide variety of industrial, commercial, and laboratory flow applications. FLR1000 Series flow sensors operate on 12 Vdc power and are designed for incorporation into data... [See More]
- Electrical Output: Current; Voltage
- Process Media Type: Liquid; Gas
- Mounting: In-line
- Operating Pressure: 40 to 500
from Clark Solutions
The PFA flow sensor has low flow sensing capabilities in a wide range of applications, and is suitable for clear, opaque, neutral, corrosive and aggressive liquids including fuel. An ultra-lightweight turbine follows the fluctuation of flow very accurately and generates a high resolution IR... [See More]
- Electrical Output: Voltage
- Mounting: In-line
- Pipe Diameter: 0.12
- End Fittings: In-line Threaded
from Flow Technology, Inc.
Sanitary applications. Flow Technology ’s sanitary turbine flow meters provide accuracy, versatility and economy in measuring a wide variety of beverage and pharmaceutical products. Flow Technology ’s more than 50 years experience enables the company to produce an extremely durable... [See More]
- Electrical Output: Voltage
- End Fittings: Tapered End Fittings
- Mounting: In-line
- Process Media Type: Liquid
from Hoffer Flow Controls, Inc.
The Hoffer Industrial Star Series Turbine Flowmeters are designed and manufactured for process liquids where cost is of primary concern. The Star meters are constructed with a simple design, allowing for rugged and dependable service at a low cost and with a timely delivery. OUTSTANDING FEATURES. [See More]
- Electrical Output: Frequency; Voltage
- Mounting: In-line
- Pipe Diameter: 0.50 to 3.00
- End Fittings: In-line Threaded
from OMEGA Engineering, Inc.
OMEGA ® FTB-201 Series turbine meters have male flared-end fittings for easy connections. They are built to meet the performance requirements of MS 33656, though they do not carry a military specification. These units come with a mating 2-wire connector and can be supplied with the integrally... [See More]
- Electrical Output: Current; Voltage
- Mounting: In-line
- Pipe Diameter: 0.75 to 1.06
- End Fittings: In-line Threaded
from Clark Solutions
The PFAD flow sensor has been developed to perform a fast exchange of the flow tube to accommodate hygienic applications in the pharmaceutical industry. It is suitable for clear, opaque, neutral, corrosive and aggressive liquids including fuel. A field replaceable ultra-lightweight turbine assembly... [See More]
- Electrical Output: Voltage
- Mounting: In-line
- Pipe Diameter: 0.28
- End Fittings: In-line Threaded
from Hoffer Flow Controls, Inc.
The Hoffer Lo-Co Series Turbine Flowmeters are designed and manufactured for process liquids where cost is of primary concern. The Lo-Co meter is Hoffer ’s most economical flow solution for your liquid flow application. OUTSTANDING FEATURES. Rugged industrial meter with all stainless steel... [See More]
- Electrical Output: Current (optional feature); Frequency; Voltage
- Mounting: In-line
- Pipe Diameter: 0.25 to 2.00
- End Fittings: In-line Flanged (optional feature); In-line Threaded
from OMEGA Engineering, Inc.
The HPF-110/120 series are compact, lightweight, self-contained portable testers with laboratory accuracy. Designed for fast diagnostic troubleshooting of all types of mobile or stationary hydraulic systems and components, makes all flow, pressure and temperature measurements simultaneously from one... [See More]
- Electrical Output: Voltage
- Mounting: In-line
- Pipe Diameter: 0.75 to 1.50
- End Fittings: In-line Threaded
from Clark Solutions
The SS housing flow sensor has low flow sensing capabilities in a wide range of applications, and is suitable for clear, opaque, neutral, corrosive and aggressive liquids including fuel. An ultra-lightweight turbine follows the fluctuation of flow very accurately and generates a high resolution IR... [See More]
- Electrical Output: Voltage
- Mounting: In-line
- Pipe Diameter: 0.18
- End Fittings: In-line Threaded
from OMEGA Engineering, Inc.
The FTB-100 Series of turbine meters have a sealed ball bearing design for high accuracy performance ( ± 1 /2 % of reading, not full scale) at an economical cost. The non-metallic bearing retainers minimize friction, thereby allowing these meters to be used with clean fluids that have poor... [See More]
- Electrical Output: Current; Frequency; Voltage
- Mounting: In-line
- Pipe Diameter: 0.50 to 3.00
- End Fittings: In-line Threaded
from OMEGA Engineering, Inc.
FTB690 Series turbine meters with microprocessor-based electronics offers a durable, compact, high-precision fluid measurement device, with total and rate indication. Information is clearly displayed on a large 6-digit liquid crystal display with only 2-point floating decimal for totals from 0.01 to... [See More]
- Electrical Output: Voltage
- Mounting: In-line
- Pipe Diameter: 0.50 to 2.00
- End Fittings: In-line Threaded