Stand Alone / Bench Transformer Test Equipment
from OMICRON electronics Corp. USA
OMICRON's CT Analyzer is a unique lightweight instrument designed to meet the highest standards for performing excitation, ratio, polarity and winding resistance tests on current transformers (CTs) as well as burden-impedance measurement. [See More]
- Form Factor: Stand Alone / Bench
- Test Parameters: DC Resistance; Turn Ratio; Winding Polarity
- Phase: Three Phase
- Features: Computer Interface
from Wayne Kerr Electronics
3255B and 3255BQ are highly versatile and accurate inductance analyzers able to characterise devices in a clear and simple manner. The three models in the range are the 3255BL (200kHz), 3255B (500 kHz) and the 3255BQ (1 MHz). At the design stage of component development it is very important to... [See More]
- Form Factor: Stand Alone / Bench
- Test Parameters: Inductance
- Phase: SIngle Phase
- Input Voltage: 115 to 230
from Tinsley Precision Instruments
The Tinsley 5896C is specifically designed to measure the resistance of highly inductive loads such as transformers, motors and generators. It has a measurement resolution of 0.01 µW for the 20 µW range and can measure resistances up to 6kW. Transformers up to 500 MVA and above can be... [See More]
- Form Factor: Stand Alone / Bench
- Features: Battery Powered; Computer Interface; Printer / Plotter Interface
- Test Parameters: DC Resistance
- Operating Humidity: 0.0 to 90
from Microtest Corporation
623x series + 7620 (transformer tester+Hi-Pot tester) 2 in 1 comprehensive transformer testing system, the one-stop comprehensive transformer testing system is the only product adopted by major Japanese manufacturers. Able to execute “High voltage ” and “Low voltage “tests... [See More]
- Form Factor: Stand Alone / Bench
- Testing Frequency: 1
- Test Parameters: Capacitance; Impedance Phase Angle; Inductance; Quality Factor; Turn Ratio
from OMICRON electronics Corp. USA
The most important aging indicator of transformers is the water content in the solid part of the insulation (paper, pressboard). An accurate knowledge about the actual moisture concentration is thus required in order to decide if further corrective action, such as on-site drying, is necessary. [See More]
- Form Factor: Stand Alone / Bench
- Test Parameters: Capacitance; Dielectric Response
- Phase: SIngle Phase
- Features: Computer Interface
from Wayne Kerr Electronics
At the design stage of component development it is vitally important to understand how the component performs under different operating conditions. This might include operation at diverse frequencies, AC drive levels or DC bias currents. The 3260B Precision Magnetics Analyzer can plot any of the... [See More]
- Form Factor: Stand Alone / Bench
- Test Parameters: Return Loss; Insertion Loss
- Phase: SIngle Phase
- Input Voltage: 115 to 230
from Tinsley Precision Instruments
An accurate mains/battery powered portable 100A Micro-Ohmmeter. Using the 4 terminal measurement technique the Tinsley 5897 gives basic accuracy of 0.2% and an overall resistance range of 0.1 µOhm to 40 Ohm. With an internal mains re-chargeable battery supply the Tinsley 5897 may be used "in... [See More]
- Form Factor: Stand Alone / Bench
- Features: Battery Powered; Computer Interface; Printer / Plotter Interface
- Test Parameters: DC Resistance
from Microtest Corporation
623x series + 7721+6905 (transformer tester+Impulse/Surge tester+Hipot tester) 3 in 1 comprehensive transformer testing system, the one-stop comprehensive transformer testing system is the only product adopted by major Japanese manufacturers. 6235. Basic precision up to 0.1%. Test frequency up to... [See More]
- Form Factor: Stand Alone / Bench
- Testing Frequency: 1
- Test Parameters: Capacitance; Impedance Phase Angle; Inductance; Quality Factor; Turn Ratio
from OMICRON electronics Corp. USA
The CMC 256plus is the universal solution for testing protection relays and calibrating electricity meters of up to class 0.2, transducers, power quality meters and synchrophasor measurement devices (IEEE C37.118). It is the right choice for all applications requiring the highest versatility and... [See More]
- Form Factor: Stand Alone / Bench
- Test Parameters: Relays
- Phase: SIngle Phase
- Input Voltage: 0.0 to 264
from Tinsley Precision Instruments
The Tinsley type 5867 uses a wound component's "Q" to give an indication of the quality of the component. It is used to compare the electrical characteristics between windings, either between a known good example and a unit under test or between phases of a three phase device. Although designed for... [See More]
- Form Factor: Stand Alone / Bench
- Test Parameters: Insulation Resistance; Quality Factor
- Phase: Three Phase
- Input Voltage: 90 to 260
from Microtest Corporation
Features. Basic accuracy up to 0.1%. User-friendly interface, high measurement speed. Innovative fixture zero-setting function to successfully prevent fixture interference from affecting the accuracy of measured values due to high test voltage. Paired with a 20-pin fixture to meet the test... [See More]
- Form Factor: Stand Alone / Bench
- Testing Frequency: 1.00E-5 to 0.2000
- Test Parameters: Capacitance; DC Resistance; Impedance; Impedance Phase Angle; Inductance; Insulation Resistance; Quality Factor; Turn Ratio
- Operating Humidity: 20 to 90
from OMICRON electronics Corp. USA
The CMC 356 is designed to optimally cover the modern requirements for commissioning and maintaining substations and protection devices. It opens up new possibilities especially for applications with 5 A CTs and for tests with very high power demand. [See More]
- Form Factor: Stand Alone / Bench
- Test Parameters: Relays
- Phase: Three Phase
- Input Voltage: 0.0 to 264
from Tinsley Precision Instruments
This Micro-Ohmmeter, Type 5895, has been specifically designed for the fast measurement of the resistance of large transformers. It is equally suitable for the measurement of any resistance where a large amount of inductance is also present. An integral timer and printer are also incorporated to... [See More]
- Form Factor: Stand Alone / Bench
- Test Parameters: DC Resistance
from Microtest Corporation
5435 transformer tester, test frequency is 20Hz~200kHz, 48 test points. By adopting innovative patent design, this tester is able to meet all your test requirements for multi-pin network communication transformer under the same volume condition. To prevent the fixture interference from affecting... [See More]
- Form Factor: Stand Alone / Bench
- Testing Frequency: 2.00E-5 to 0.2000
- Test Parameters: Capacitance; DC Resistance; Impedance; Impedance Phase Angle; Inductance; Insulation Resistance; Quality Factor; Turn Ratio
- Operating Humidity: 10 to 90