Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: BMT USA, LLC
Description: BMT Sterivap High Performance Industrial Lab steam sterilizers are designed for the rigorous demands of today’s industrial labs. The units are ideal for applications in laboratories for sterilization of materials such as instruments, textiles, rubber goods, liquids, agars, animal diet, cages
- Capacity: 31.759999999999998 cubic feet
- Features: Air Filtration, Cooling System, Front Panel & Display, Shelving / Racks / Carts, Timers
- External: Bench / Cabinet
- Application: Industrial, Laboratory
-
Supplier: BMT USA, LLC
Description: BMT Ventipharm Steam-Air Mixture Sterilizers provide fast, safe and effective terminal sterilization of liquids in sealed or heat sensitive containers. Pure steam is utilized inside the chamber for heating the liquids and over-pressure air is injected into the chamber to compensate for the
- Capacity: 0.05607632891831049 cubic feet
- External: Front Load (incl. Walk-in, Truck-in)
- Features: Front Panel & Display, Other, Shelving / Racks / Carts, Timers
- Application: Industrial
-
Supplier: ASTM International
Description: peel. These pouches are typically manufactured by heat sealing, or in some cases, by cohesive cold sealing. The sealing bond is intended to be peeled open to aseptically dispense the contents. 1.3 Pouch materials may be either porous, nonporous, or any combination of the two. 1.4 This guide
-
-
Supplier: Fredericks Company - Televac
Description: Cleanable Cold Cathode Sensor Range: (10-11 to 10-2 Torr) Robust Construction: All wetted materials are 304 stainless. Metal-sealed/cleanable subassembly can be maintained without breaking the primary vacuum interface UHV Compatible: Knife edge seals and 10-11 std. cc/sec. (He) leak rate
- Vacuum Range: 0.00999999999992553 to 0.00000000001010675987345166 torr
- Operating Temperature: 32 to 122 F
- Media: Gas
- Measurement Type: Gauge, Vacuum
-
Supplier: Fredericks Company - Televac
Description: Vacuum Sensor Range: (1x10-2 to 1x10-11 Torr) Ignites 10 times faster than standard cold cathodes during power interruption at ultra high vacuum. Robust Construction: All wetted materials are 304 stainless. Metal-sealed/cleanable subassembly can be maintained without breaking the primary
- Vacuum Range: 0.00999999999992553 to 0.00000000001010675987345166 torr
- Operating Temperature: 32 to 122 F
- Media: Gas
- Measurement Type: Gauge, Vacuum
-
Supplier: U.S. Plastic Corporation
Description: The 1/4" flow PLC series is proven worldwide in thousands of applications and offers the widest selection of sizes and configurations. PLC couplings are injection molded from acetal and polypropylene thermoplastic. Acetal fittings are resistant to most mild chemicals solutions. Polypropylene
- Material: Polypropylene (PP)
-
Supplier: Cole-Parmer
Description: • One connection for steam sterilization and microbiological process • Disposable -- saves time and money on cleaning • Eliminates dead legs where bacteria can grow • Connects to most bio-bag connections These steam-through connections will transform your steam-in place (SIP) process by
- Features: English, Sanitary / Food Grade Fitting
- Fitting Type: Hose Fitting, Tube Fitting
-
Supplier: Cole-Parmer
Description: • One connection for steam sterilization and microbiological process • Disposable -- saves time and money on cleaning • Eliminates dead legs where bacteria can grow • Connects to most bio-bag connections 3/4 sanitary clamp steam inlet • 3/4 sanitary clamp bioreactor outlet • 3/8" hose barb
- Fitting Type: Hose Fitting, Tube Fitting
- Features: Sanitary / Food Grade Fitting
-
Supplier: Cole-Parmer
Description: • One connection for steam sterilization and microbiological process • Disposable -- saves time and money on cleaning • Eliminates dead legs where bacteria can grow • Connects to most bio-bag connections 3/4 sanitary clamp steam inlet • 3/4 sanitary clamp bioreactor outlet • 1/2" hose barb
- Fitting Type: Hose Fitting, Tube Fitting
- Features: Sanitary / Food Grade Fitting
-
Supplier: Cole-Parmer
Description: • One connection for steam sterilization and microbiological process • Disposable -- saves time and money on cleaning • Eliminates dead legs where bacteria can grow • Connects to most bio-bag connections 3/4 sanitary clamp steam inlet • 3/4 sanitary clamp bioreactor outlet • 3/8" hose barb
- Fitting Type: Hose Fitting, Tube Fitting
- Features: Sanitary / Food Grade Fitting
-
Supplier: Fiberoptics Technology, Inc.
Description: GENERAL FEATURES: Outstanding light transmission Leak tight construction utilizing molded "boots" to eliminate joints and minimize collection of foreign matter Compatible with high speed (flash) sterilizing systems, cold sterilization and the Steris process Color Coded sheathing -
- Length: 2,285.998765560667 mm
- Diameter: 2.5000000000000004 mm
- Bend Radius: 12.699993142003704 mm
- Light Guide Type: Fiber Optic
-
Supplier: Fiberoptics Technology, Inc.
Description: GENERAL FEATURES: Outstanding light transmission Leak tight construction utilizing molded "boots" to eliminate joints and minimize collection of foreign matter Compatible with high speed (flash) sterilizing systems, cold sterilization and the Steris process Color Coded sheathing -
- Length: 3,047.998354080889 mm
- Diameter: 5.000000000000001 mm
- Bend Radius: 12.699993142003704 mm
- Light Guide Type: Fiber Optic
-
Supplier: Fiberoptics Technology, Inc.
Description: GENERAL FEATURES: Outstanding light transmission Leak tight construction utilizing molded "boots" to eliminate joints and minimize collection of foreign matter Compatible with high speed (flash) sterilizing systems, cold sterilization and the Steris process Color Coded sheathing -
- Length: 1,828.7990124485334 mm
- Diameter: 2 mm
- Bend Radius: 12.699993142003704 mm
- Light Guide Type: Fiber Optic
-
Supplier: Total Lubricants USA, Inc.
Description: Ivory-colored, synthetic, calcium sulfonate complex grease adapted to extreme temperatures and provides high mechanical stability. Resistant to water, steam, food acids and alkalis. Uses include: bearings, rollers, guides, pumps, hot and cold applications, and sterilizers in the canning
- Features: Aerosol / Spray, Lubricant
- Composition / Chemistry: Synthetic / Semi-synthetic
-
Supplier: Suttner America Company
Description: Steam is ideal for removing grease and oil, sterilizing surfaces, melting ice, plus using where little water is available like oil fields.
- Water Jet Pressure: 290 psi
- Operation: Cleaning / Surface Preparation
- Features: Cold Water, Gun / Lance, Hot Water / Steam
- Machine Mounting: Handheld, Portable Machine
-
Supplier: Sanuvox Technologies, Inc.
Description: The Multi-IL Coil Clean helps reduce ethylene buildup within the food storage room to slow the ripening of fruits. It’s powerful UV also helps against molds, bacteria and viruses. Ideal for any cold room equipped with a cooling system, or a walk-in storing fruits and vegetables, the Multi-IL
- Features: Surface Disinfection (Part Sterilizers)
- Applications: UV Disinfection / UVGI Sanitization
-
Supplier: Total Plastics, Inc.
Description: Natural Medical grade UHMWPE is produced from premium resins in accordance with ASTM specification F648 and International Standard ISO 5834 -1 for surgical implants. Recommended sterilization techniques include EtO gas, cold sterilization, and limited gamma irradiation. UHMWPE
- Overall Width / O.D.: 0.5 to 4 inch
- Overall Length: 60 to 120 inch
- Industry: Medical / Food (FDA, USDA)
-
Supplier: Air Impurities Removal Systems, Inc.
Description: Compound Filter 1 (Stages 2-3): Cold Catalyst Filter and Honeycomb Activated Carbon Filter Compound filter made up of a Cold Catalyst Filter and Honeycomb Activated Carbon Filter, which work together to remove VOCs and odors from the air, including: Formaldehyde, Ammonia, Benzene, and
- Length: 18 inch
- Height: 12.5 inch
- Width / Ring Size: 0.75 inch
- Media Type: Activated Carbon / Charcoal
-
Supplier: Despatch - ITW EAE
Description: a pressure relief system that includes a removable “cold trap”, an easy-to-clean condensate trap that helps to prevent polyimide buildup in the oven’s exhaust. Oxygen Monitor and Control System The PCO2-14™ is an inert atmosphere oven which allows the oxygen level to be maintained at 20ppm or
- Temperature Range: 95 to 662 F
- Capacity: 13.999999999999998 cubic feet
- Features: Air / Oxidizing, Air Filtration, Alarms, Baking, Cleanroom, Cooling System, Curing, Front Panel & Display, Shelving / Racks / Carts
- External: Bench / Cabinet, Front Load (incl. Walk-in, Truck-in)
-
Supplier: Air Impurities Removal Systems, Inc.
Description: humidifier, air quality sensor, and easy-to-use control panel allowing for full control over the air you breathe. Included With Product Touchscreen control panel Remote control Air quality sensor Humidification function 7-Stage Purification, including: Aluminum Filter Cold Catalyst Filter
- Air Flow Volume: 509.91790321758197 m³/hr
- Technology: Adsorbtion, Activated Carbon, HEPA Filter, Portable
- Application: Industrial
-
Supplier: Total Plastics, Inc.
Description: withstand higher temperatures with less water absorption than standard polypropylene. Recommended sterilization techniques for Propylux® HS include steam autoclaving and cold sterilization. Propylux® HS2 is produced from an FDA and USP Class VI approved homopolymer resin and
- Chemical System: Polypropylene (PP)
-
Supplier: Total Plastics, Inc.
Description: deflection temperatures and outstanding resistance to environmental stress cracking. Recommended sterilization techniques for Radel® R5500 include EtO gas, radiation, steam autoclaving, dry heat and cold sterilization. It is lot controlled and traceable and markable. The resin
- Overall Width / O.D.: 1 to 3.5 inch
- Overall Length: 48 to 96 inch
- Industry: Medical / Food (FDA, USDA)
- Form / Shape: Rod / Round Stock
-
Supplier: Tekscan, Inc.
Description: Sensels for precise data Reusable on single patient Cold sterilization between visits Able to withstand 15-25 closures Research-proven, repeatable results Large and small sizes are available Easy to insert into Novus™ Handpiece and Support
- Force Measured: Compression
- Output: Digital
- Device: Sensor / Transducer
-
Supplier: Watts
Description: Series 9D Dual Check Valves with Intermediate Atmospheric Vent prevent the reverse flow of hot or cold polluted water from entering into the potable water supply. It consists of a brass body with stainless steel internal parts, integral strainer, and two durable, tight-sealing, rubber check
- Valve Size: 0.5 to 0.75 inch
- Valve Type: Check Valves
-
Supplier: ASCO
Description: • Hot water service to 150 psi @ 210°F; Steam sevice to 125 psi @ 353°F • Specify these valves for the high-temperature applications found in laundries, molding, steam atomization, sterilizers, autoclaves, and many others • Series 8220: pilot operated diaphragm and piston valves; floating PTFE
- Valve Size: 0.625 inch
- Flow (Cv): 3
- Number of Ports/Ways: 2
- Power: 240 volts
-
Supplier: Hartford Technologies, Inc.
Description: cold worked, 1.10; severely cold worked, 10.0. High tensile strength at elevated temperatures. 18-8 stainless steel work-hardens rapidly. AISI 304/302 stainless steel balls of this material are passivated. Corrosion Resistance Type 18-8 stainless steel balls resist attack by oxidizing
- Diameter / OD: 0.05905515 to 2.00000108 inch
- ANSI / ABMA Grade: 50 to 1,000 #
- Applications: Bearing / Power Transmission, Couplings / Fasteners, Sprayers / Pumps, Valves
- Features: Corrosion Resistant, Stainless Steel
-
Supplier: U.S. Plastic Corporation
Description: areas, and include a polyvinyl chloride gasket in the cap. Made of high density polyethylene, they can withstand cold sterilization, and are odorless and flavorless. Not for fuels or oils, nor are they graduated. Meets FDA standards and lids are high density polyethylene. UN approved
-
Supplier: Reid Supply
Description: Type 303 is highly corrosion resistant and non-magnetic. It has non-galling and non-seizing qualities which allow for easy machining and is better for lighter equipment if welding is not required. When cold worked, can become slightly magnetic. Free machining for heavier cuts in automatic
- Overall Width / OD: 0.5 inch
- Overall Length: 36 inch
- Shape / Form: Bar Stock, Rod / Round Bar Stock, Semi-finished Shape / Mill Stock
- Features: Ferrous / Iron Based - Any Type, Specialty / Other
-
Supplier: 3X Ceramic Parts Company Limited
Description: High Precision Ceramic Pump for Pharmacy Characteristics of ceramic pump for pharmacy : 1. Using high purity alumina material , formed with cold isostatic pressing and sintered in high temperature , with high density . 2. High dimension precision and assemble with metal part perfectly . 3.
- Pump Type: Piston / Plunger Pumps, Positive Displacement Pumps
-
Supplier: CoorsTek
Description: applications, including: Beer Clarification Pharmaceutical Grade Amino Acid Production Cold Sterilization of Skimmed Milk Industrial Laundry/Washing Machines
- Application / Industry: Biopharmaceutical, Food and Beverage, Medical
- Filter Medium Material: Ceramic
- Additional Features: FDA Compliant
- Configuration: In-line
-
Description: IEC TS 63331:2024 applies to electric dishwashers for household and similar use that are supplied with hot and/or cold water. This document deals with measurement procedures regarding the reduction of microbial contamination resulting from the use of electric dishwashers for household and
-
Supplier: Terra Universal, Inc.
Description: Ideal for cleanroom use with design that meets Class 100 standards Quick Release Vacuum System” for easy cleaning, sterilizing and maintenance Full Digital PLC Controller with LCD Touchscreen Non-Particle generating Venturi vacuum system Isolated exhaust port Visible and audible alarms for:
- Packaging: Bag / Pouch
- Goods: Consumer Packaging
- Closing Method: Heat Seal
- Industry: Industrial / General Use, Medical
-
Supplier: Traceable® Products
Description: impossible-to-control squeeze bottle obsolete. The instant-off trigger release eliminates messy drips on the bench. Chemical-resistant and virtually unbreakable bottle is made of high-density polyethylene (HDPE). The sprayer is made of polypropylene (PP). Ideal for hot, cold, aqueous, and
- Container Size: 240 cc
- Dispensed From: Bottle
- Application: Cleaners / Sanitizers
- Dispensing Equipment Type: Dispense Only
Find Suppliers by Category Top
Featured Products Top
-
The DTV drain tempering valve is used in applications where a high-temperature discharge flow to a drain or sewer must be tempered with cold water. The thermostatic valve automatically operates to keep drain water within appropriate plumbing code limits and (read more)
Browse Tempering Valves and Thermally Actuated Valves Datasheets for ThermOmegaTech® -
: Medical and Life Sciences - Dialysis, CPAP, DNA analysis and testing, blood diagnostics, surgical devices, vessel sealer, blood and fluid warming, instrument warming, MRI equipment, temperature therapy, and sterilization. Aviation & Transportation (read more)
Browse Industrial Heaters Datasheets for Heatron, Inc. -
autoclave, H2O2, and ETO sterilization Excellent resistance to hospital-grade chemicals and solvents High-dielectric strength makes it possible to extrude a thin wall No shrink back during high-temperature soldering Low cold flow of 2.5% with minimal (read more)
Browse Control and Instrumentation Cables Datasheets for Northwire, Inc. -
Yes (up to 29 days) No Is sterilization required? Gamma Autoclave ETO Wipe Down What regulatory (read more)
Browse Cable Assembly Services Datasheets for Northwire, Inc. -
tear into the tubing wall and possibly cause a failure. ^SILCON may be low pressure steam sterilized in-line or autoclaved at up to 250°F in a normal autoclaving cycle. However, if exposed to repeated steam sterilization or long-term high temperature or pressure, silicone will eventually (read more)
Browse Tubing Datasheets for NewAge Performance Products | NAPP -
inside the lamp determines the type of UV light emitted. Options for UV lamps range from hot or cold cathode, slimline, low/high/very high ozone, low/high output, amalgam, excimer, pulsed xenon, or even black light. They are also coated differently to help achieve the intended use. Specific (read more)
Browse UV Disinfection and UVGI Sanitization Systems Datasheets for AirClean Systems
Conduct Research Top
-
Cold Supply Chain: Fluoropolymer Solutions
Manufactured using premium resin, DeWAL (R) skived PTFE film conforms to strict standards and tolerances. With a natural resistance to most chemistries, biological inertness, excellent range of operational temperatures (-40 C to 250 C), and an ability to be sterilized via autoclave and ethylene
More Information Top
-
Effect of Combined Treatment of Serum Containing Hepatitis B Virus with Beta‐Propiolactone and Ultraviolet Irradiation
Abstract The effect of cold sterilization by β‐propiolactone (β‐PL) and ultraviolet (UV) irradiation of serum contaminated with infectious hepatitis B virus (HBV) was investigated in chimpanzees.
-
FACTORS INFLUENCING THE INCIDENCE OF B. CEREUS SPORES IN MILK
For this reason detergent at 6OoC for 15 rnin followed by a cold sterilizing solution is often used.
-
Hemodiafiltration
Keywords End stage chronic kidney disease • Renal replacement therapy • Online substitution fluid • Cold sterilization process • Convective dose .
-
Plasma for Bio-Decontamination, Medicine and Food Security
1997) Cold sterilization of medical devices and materials by plasma DC glow discharge.
-
Handbook of Food Process Design, 2 Volume Set
In recent years it has been reported that membranes can also be used for cold sterilization of liquid food materials, with improved shelf-life and retention of flavor and nutrients.
-
Handbook of Preservatives
Uses: Yeast inhibitor, bactericide, sterilizer for cold sterilization of beverages .
-
Directory of Microbicides for the Protection of Materials
So the susceptibility of the beverage and the requirements in the production of these types of beverages and the use of cold sterilising agents will grow.
-
Glutaraldehyde exposure and its occupational impact in the health care environment
Substitution with automated cold sterilization machines may be another appropriate measure, while banning unnecessary practices such as GA fogging and its use as a surface disinfectant may also be helpful in reducing occupational exposure in the health care environment.
-
Over the culture of Empusa muscae Cohn and other Entomophthoraceen on coldly sterilized breeding grounds
In the last years cold sterilization has often been refined, and fibers also could it mehrfaeh the successes by the Zfiehtung parasite ~ rer and symbiontiseher microbes on to be reported coldly sterflisierten N / ~ hrbSden (40, 41, 42, 43).
Indicates content that may require registration and/or purchase.