Supplier: Linde North America, Inc.
Description: Constant monitoring through various analytical procedures ensures that the pure gases you receive meet the minimum purity levels specified by Linde, and of course your exact specifications. In addition to our standard catalogue products, many gases of higher purity are available on special order.
- Composition: Pure Gas
- Concentration: 99.8 to 100 %
- Oxygen and Oxides: Carbon Dioxide
- Product Forms: Liquid / Liquid Gas
-
Supplier: Linde North America, Inc.
Description: VERISEQ® Process Grade Gases are developed to suit the needs of the producing pharmaceutical industry. The unique products help manufacturers comply with the applicable regulations on gas used in pharmaceutical production. By turning to VERISEQ, the producer of pharmaceuticals or active ingredients
- Composition: Pure Gas
- Concentration: 99.5 to 99.99 %
- Oxygen and Oxides: Carbon Dioxide
- Product Forms: Gas, Liquid / Liquid Gas
-
Supplier: Linde North America, Inc.
Description: , refrigeration systems require special equipment designs. Linde - offering combined expertise in carbon dioxide and refrigerants Linde is one of the largest suppliers of carbon dioxide in the world, with a substantial global production and distribution network. Linde has
- Applications: Specialty
-
-
Supplier: Accuris
Description: Liquid Carbon Dioxide
-
Description: For over 20 years, Cat Pumps has been providing liquid CO2 pumping solutions. Working closely with research facilities, universities, equipment manufacturers and site locations to develop optimal solutions has established Cat Pumps as an industry leader. The two decades of liquid CO2
- Housing Material: Brass / Bronze, Stainless Steel
- Maximum Discharge Pressure: 1450 psi
- Maximum Discharge Flow: 5 GPM
- Power Source: None, Pump Only
-
Supplier: Accuris
Description: Liquid carbon dioxide (Amendment 1)
-
Supplier: Accuris
Description: Specification for Liquid Carbon Dioxide, Industrial
-
Supplier: Branch Environmental Solutions
Description: Removal of Carbon Dioxide from water can be accomplished at low cost using a Branch Air Stripper. The C02 Degasifier is simply an air stripper designed specifically for removal of dissolved carbon dioxide. Ambient air can be used to remove the dissolved gas down to low
-
Supplier: Accuris
Description: PLANT, CARBON DIOXIDE REMOVAL, LIQUID ABSORBENT TYPE (MARK IV)
-
Supplier: IHS ESDU
Description: ESDU 76021 tabulates dynamic viscosity values for temperatures from 240 to 1500 K and pressures from 1 to 1000 atmospheres. Also tabulated are dynamic and kinematic viscosities for saturated liquid and vapour. The dynamic viscosities were derived by fitting an equation (as a function of
-
Supplier: IHS ESDU
Description: ESDU 76030 tabulates thermal conductivity values for temperatures from 240 K to 1500 K and pressures from 1 to 1000 atmospheres. Also tabulated is thermal conductivity of liquid and vapour along the saturation line. The values were derived by fitting an equation (as a function of density and
-
Description: carbon dioxide intended for purging and pressurization in both space systems flight hardware and ground support facilities, systems, and equipment. ISO 15859-12:2004 may be applied to carbon dioxide influents. Carbon dioxide may be of the gaseous or
-
Supplier: GENERON
Description: Coal fired power plants are considered the largest emitters for CO2. Membranes can dramatically help reduce the carbon footprint of these power plants by removing CO2 from the plant flue gas. GENERON's® Flue Gas Treatment Systems can be used to remove the CO2
- Configuration: In-line
- Industry Use: Hydrocarbon Processing (Oil & Gas)
- Maximum Pressure: 1000 psi
- Maximum Temperature: 6.94 to 69400 SCFM
-
Supplier: GENERON
Description: particles and liquid condensate. The gas then enters the GENERON® membrane filters. The CO2 permeates preferably through the membrane. The non-permeated gas, mainly CH4, remains at pressure and is the product gas. SYSTEM PERFORMANCE Feed gas
- Configuration: In-line
- Industry Use: Hydrocarbon Processing (Oil & Gas)
- Maximum Pressure: 1000 psi
- Maximum Temperature: 6.94 to 347000 SCFM
-
Supplier: ASTM International
Description: other than oxygen and nitrogen in atmospheric ratios due to differential solubility effects. Gases which react with KOH such as carbon dioxide will not be measured. Unsaturated hydrocarbons such as acetylene, if present, will react with KOH to a small degree and will result in an
-
Supplier: CSA Group
Description: carbon dioxide intended for purging and pressurization in both space systems flight hardware and ground support facilities, systems, and equipment. ISO 15859-12:2004 may be applied to carbon dioxide influents. Carbon dioxide may be of the gaseous or
-
Supplier: ASTM International
Description: gases other than oxygen and nitrogen in atmospheric ratios due to differential solubility effects. Gases which react with KOH such as carbon dioxide will not be measured. Unsaturated hydrocarbons such as acetylene, if present, will react with KOH to a small degree and will result in an
-
Supplier: ASTM International
Description: 1.1 This test method covers the analysis of demethanized liquid hydrocarbon streams containing nitrogen/air and carbon dioxide, and purity products such as an ethane/ propane mix that fall within the compositional ranges listed in Table 1. This test method is limited to mixtures
-
Supplier: ASTM International
Description: gases other than oxygen and nitrogen in atmospheric ratios due to differential solubility effects. Gases which react with KOH such as carbon dioxide will not be measured. Unsaturated hydrocarbons such as acetylene, if present, will react with KOH to a small degree and will result in an
-
Supplier: ENMET Corporation
Description: P/N 10014-024, EX-5165 Infrared Sensor/Transmitter for Carbon Dioxide, CO2 The EX-5165 incorporates a miniature NDIR type sensor for the measurement of carbon dioxide concentrations ranging from 500 ppm to 100% by volume. The sensor is comprised of dual pyroelectric
- Display: Digital
- Electrical Outputs: Analog Current
-
Supplier: GFS Chemicals, Inc.
Description: ITEM#:884 CS2 CAS#:75-15-0 F.W.:76.13 NFPA#:3-3-0 Specific Gravity: 1.261 DOT:3/6.1/I Descriptions: Specification TEST 1. Assay 99.9% min 2. Color (APHA) 10 max 3. Residue after evaporation 0.002% 4. Hydrogen sulfide - Pass Test 5. Sulfur dioxide - Pass Test 6. Water 0.05% Properties No
- State of Matter: Liquid / Solution
-
Supplier: BITZER US, Inc.
Description: The horizontal and vertical liquid receivers are available for HFC/(H)CFC refrigerants, ammonia, hydrocarbon and carbon dioxide and fulfil the various requirements of refrigeration and air conditioning technology. Operating temperatures of –10°C to 120°C are possible with a
- Pressure Rating: 406 to 653 psi
- Type: Process Tank, Other Tank
-
Supplier: GFS Chemicals, Inc.
Description: evaporation 0.002% 4. Hydrogen sulfide - Pass Test 5. Sulfur dioxide - Pass Test 6. Water 0.05% 7. Benzene 0.0001% (1 ppm) Properties No properties.
- Classical Arenes: All Classical Arenes, Benzene
- State of Matter: Liquid / Solution
- Type: Solvent
-
Supplier: Hoffer Flow Controls, Inc.
Description: OUTSTANDING FEATURES Grooved Turbine Flowmeters for Oil Patch flow applications Grooved Service applications include Water, Water/ Sand, Liquid Carbon Dioxide, and Cement Slurry
- Liquid Volumetric Flow Rate: 4 to 12000 GPM
- Electrical Output: Analog Current, Analog Voltage, Frequency
- End Fittings: Other
- Features: Measures Temperature, Audible or Visual Alarms, Controller Functions, Programmable, Recorder / Totalizer Functions
-
Supplier: ASME
Description: from the many industry best-practices detailed within these volumes. Intended for liquid pipeline designers, owners, regulators, inspectors, and manufacturers. Primary industries served include those for carbon dioxide, liquid alcohol, liquid anhydrous ammonia, and
-
Supplier: ASME Standards and Certification
Description: from the many industry best-practices detailed within these volumes. Intended for liquid pipeline designers, owners, regulators, inspectors, and manufacturers. Primary industries served include those for carbon dioxide, liquid alcohol, liquid anhydrous ammonia, and
-
Supplier: Hydrofarm, Inc.
Description: simply by installing additional burners. Each burner increases the CO2 generating capacity by approximately 3 cubic feet per hour. There is no need to purchase a different generator if your needs increase! Carbon Dioxide (CO2) is one of the easiest ways to accelerate plant growth.
-
Supplier: Hydrofarm, Inc.
Description: by installing additional burners. Each burner increases the CO2 generating capacity by approximately 3 cubic feet per hour. There is no need to purchase a different generator if your needs increase! Carbon Dioxide (CO2) is one of the easiest ways to accelerate plant growth. Plants
-
Supplier: Hydrofarm, Inc.
Description: installing additional burners. Each burner increases the CO2 generating capacity by approximately 3 cubic feet per hour. There is no need to purchase a different generator if your needs increase! Carbon Dioxide (CO2) is one of the easiest ways to accelerate plant growth. Plants grown
-
Supplier: Restek
Description: -5, red LED Nitrogen, 1.4 x 10-3, yellow LED Argon, 1.0 x 10-4, yellow LED Carbon dioxide, 1.0 x 10-4, yellow LED Gas detection limits measured in atm cc/sec. Avoid using liquid leak detectors on a GC! Liquids can be drawn into the system and/or into the leak detector
- Display: Analog
- Features: Audible or Visual Alarms
- Instrument Type: Detector
- Mounting Type: Portable
-
Supplier: Clark Solutions
Description: , gasoline and many other low and medium viscosity liquids (maximum viscosity 500 centipoise). Gas flow meters are suitable for compressed air and most other compressed gases including carbon dioxide, helium and hydrogen, acetylene, nitrogen. Standard pressure rating is to 180
- Liquid Volumetric Flow Rate: 2 to 500 GPM
- Electrical Output: Analog Current, Frequency, Switch
- End Fittings: Threaded, Other
- Features: Recorder / Totalizer Functions
-
Supplier: OMEGA Engineering, Inc.
Description: for nitrogen, oxygen, hydrogen, helium, argon and carbon dioxide, please refer to the FLT Series flow tubes. Please consult the Engineering Department for details. The scale is fused on the metering tube in 1 mm (3/32") increments, which enables a user to read the flow rate with the
- Liquid Volumetric Flow Rate: 5.07E-4 to 0.4969 GPM
- End Fittings: Threaded
- Media Temperature Range: 180 to 250 F
- Mounting Type: In-line
-
Supplier: OMEGA Engineering, Inc.
Description: for nitrogen, oxygen, hydrogen, helium, argon and carbon dioxide, please refer to the FLT Series flow tubes. Please consult the Engineering Department for details. The scale is fused on the metering tube in 1 mm (3/32") increments, which enables a user to read the flow rate with the
- Liquid Volumetric Flow Rate: 1.85E-5 to 0.4969 GPM
- End Fittings: Threaded
- Media Temperature Range: 180 to 250 F
- Mounting Type: In-line
-
Supplier: Halliburton
Description: BARAFILM™ corrosion inhibitor is a filming amine corrosion inhibitor that physically and chemically absorbs on metal to help protect it from hydrogen sulfide, carbon dioxide, and oxygen corrosion.
- Applications: Oils & Gas / Drilling Fluids
- Form: Liquid / Solution
- Function: Corrosion Inhibitor / VCI
-
Supplier: RS Components, Ltd.
Description: The PFM series from SMC are dual flow switches designed to detect microchip component adsorption in vacuum, congestion in filters and nozzles. Compact and light weight design, suitable for use with carbon dioxide, air, nitrogen or argon. Flow rate range: 10, 25, 50,100 l/min. Minimum
- Electrical Output: Switch
- Media Temperature Range: 32 to 122 F
- Operating Pressure: 109 psi
- Pipe Diameter: 0.1575 inch
-
Supplier: RS Components, Ltd.
Description: The PFM series from SMC are dual flow switches designed to detect microchip component adsorption in vacuum, congestion in filters and nozzles. Compact and light weight design, suitable for use with carbon dioxide, air, nitrogen or argon. Flow rate range: 10, 25, 50,100 l/min. Minimum
- Electrical Output: Switch
- Media Temperature Range: 32 to 122 F
- Operating Pressure: 109 psi
- Pipe Diameter: 0.2362 inch
-
Supplier: RS Components, Ltd.
Description: The PFM series from SMC are dual flow switches designed to detect microchip component adsorption in vacuum, congestion in filters and nozzles. Compact and light weight design, suitable for use with carbon dioxide, air, nitrogen or argon. Flow rate range: 10, 25, 50,100 l/min. Minimum
- Electrical Output: Switch
- Media Temperature Range: 32 to 122 F
- Operating Pressure: 109 psi
- Pipe Diameter: 0.3150 inch
-
Supplier: Hydrofarm, Inc.
Description: CalCarb, is a revolutionary calcium carbonate foliar spray proprietarily-derive d from a natural occurring compound. It utilizes a new form of nanotechnology which processes the compound to such a fine size that it is able to permeate the foliage of plants. Once inside the cell walls, CO2 is
- Applications: Agriculture
- Form: Liquid / Solution, Powder
-
Supplier: Minerallac Company
Description: [R] BRAND EXTINGUISHING MEDIA CARBON DIOXIDE, DRY CHEMICAL, FOAM SPECIFIC GRAVITY 0.75 PH VALVE 7 VOC 51.76 PERCENTAGE
- Chemistry: Acrylic / Latex
- Form: Liquid
- Industry: OEM / Industrial
- Type: Enamel Paint
Find Suppliers by Category Top
Featured Products Top
-
One of the specialty machining processes available at Protomatic is our carbon dioxide coolant. In many applications, the typical "flood coolant" is sufficient. However, in applications requiring high cleanliness, or high-performance machining such as medical implant parts, carbon dioxide (read more)
Browse CNC Machining Services Datasheets for Protomatic, Inc. -
stainless steel compressors for controlling carbon dioxide CO2 which when mixed with water makes corrosive carbonic acid. Chicken and fish evisceration vacuum pumps need to be stainless steel as periodic flushing is done to kill bacteria (read more)
Browse Vacuum Pumps and Vacuum Generators Datasheets for Vooner FloGard LLC -
At CO2Meter, we are often asked, "What CO2 level is dangerous?" and we note that CO2 levels above 40,000ppm (4%) are life threatening. However, there are many other limits placed on carbon dioxide levels depending on your application. These limits are defined by agencies such as (read more)
Browse Gas Instruments Datasheets for CO2Meter.com -
Tanks Mining Plants: Particulate control Lime Sludge Kilns Carbon Black Plants Fertilizer Plants Paper Grinding Pelletizing Operations Sintering Plants Ore Dryers Clay Preparation Titanium Dioxide (read more)
Browse Baghouses and Baghouse Filters Datasheets for Ducon Environmental Systems -
equally emission-intensive. In particular, they produce carbon dioxide and nitrogen oxide, two pollutants that are coming under increasingly stringent regulation by the Environmental Protection Agency (EPA). But now, with the successful introduction of the world’s first 4kV heater (read more)
Browse Industrial Heaters Datasheets for Gaumer Process -
particular, they produce carbon dioxide and nitrogen oxide, two pollutants that are coming under increasingly stringent regulation by the Environmental Protection Agency (EPA). But now, with the successful introduction of the world’s first 4kV heater, industry has the power to change its (read more)
Browse Electric Heaters Datasheets for Gaumer Process -
carbon dioxide (CO2) gas with water. The CO2 gas helps mobilize the remaining oil, while injecting water displaces the remaining oil and gas. In a typical WAG system, the V-Cone Flow Meter is installed as a master (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
Once the bauxite is dissolved, alumina can be collected after its sodium aluminate solution is combined with carbon dioxide. Crystals are created through this. They are made from alumina hydrate. Additional processes involve the alumina being filtered so (read more)
Browse Industrial Fabrics Datasheets for Mid-Mountain Materials, Inc. -
name for this compound is alumina. Alumina can be extracted by using caustic soda on the bauxite. Once the bauxite is dissolved, alumina can be collected after its sodium aluminate solution is combined with carbon dioxide. Crystals are created through this. They (read more)
Browse Accordion Bellows and Protective Boots Datasheets for Mid-Mountain Materials, Inc. -
that is separated from the oil stream once it reaches the surface. The well operator then re-injects a portion of this byproduct gas, in turn maximizing production from the well. Carbon dioxide, nitrogen, or engineered chemical solutions can also be employed in gas lift wells. Through EOR (read more)
Browse Flow Meters Datasheets for McCrometer, Inc.
Conduct Research Top
-
CO2 Tank Safety Precautions
Whether you use a CO2 cylinder or a bulk CO2 tank system, you should be aware of CO2 tank safety. Thousands of liquid carbon dioxide cylinders and tanks are used across the country for soda or beer carbonation, for refrigeration, industrial purposes, medical and scientific facilities, and even
-
CO2 Tank Safety & CO2 Cylinder Safety
Whether you use individual CO2 cylinders or a bulk CO2 tank system, you should be aware of CO2 tank safety. Thousands of liquid carbon dioxide cylinders and tanks are used across the country for soda or beer carbonation, for refrigeration, industrial purposes, medical and scientific facilities
-
Liquid Cooling a Laser for System Optimization
The performance of high-powered lasers depends on effective cooling. High-powered lasers generate a significant amount of heat that must be removed from the laser system to avoid overheating critical components. Carbon dioxide (CO2) lasers, excimer lasers, ion lasers, solid-state lasers, and dye
-
Bottoms Up: How Better Mixer Chilling Can Improve Your Food Process
When it comes to cryogenic chilling, processors may be better starting at the bottom. The bottom of their mixer, that is. Strategically injecting. cryogens such as carbon dioxide or liquid nitrogen directly into the bottom of a mixture chills food faster, more effectively and at a lower cost than
-
Why Measure CO2?
in Confined Spaces. Portable handheld CO2 Meter. Carbon dioxide, in the form of underground off-gassing, dry ice or liquid CO2 delivery systems, or portable heaters can pose a potential deadly threat. Because it is odorless and colorless, workers can easily be overcome by high levels of CO2 in enclosed
-
Dry Ice vs. Soda Blasting
Abrasive blasting with sodium bicarbonate (i.e., baking soda) is a popular surface-cleaning technique, but there are equally popular alternatives as well. One alternative method is dry ice blasting. Dry ice blasting involves propelling dry ice, which is solid carbon dioxide, against a surface
-
Mission Supercritical
in key benign solvents --supercritical carbon dioxide and near-critical water, to name two --opening the door for pharmaceutical applications. Supercritical CO2 is carbon dioxide that has been compressed to a degree where it exhibits some liquid, solvent-like properties. It is readily available
-
The Pitfalls of Process TOC Analysis and How To Avoid Them (.pdf)
acid is added to the sample, dropping its pH to approximately 2.0. At this point, the IC is converted to carbon dioxide (CO2) gas, which is stripped out of the liquid by a sparge carrier gas. The remaining inorganic carbon-free sample is then delivered to the Oxidation Chamber.
-
Low-Risk Lyophilization
? In this instance, what is the tolerable concentration range of the formulated solution that can be expected to prevent one formulated lot from precipitating while another does not? Is the ionic strength of the formulated liquid so low that the solubility of carbon dioxide in the liquid impacts the pH
-
Tuning in to New Solvents
Operational Excellence & Lean Six Sigma organic solvents mixed with carbon dioxide gas, which expands their volume by a factor of 10 or more. Nutraceuticals production has moved in the direction of GXLs, by using ethanol cosolvent as a polar modifier with scCO . This results in a solvent medium
-
Tuning in to New Solvents
hydrolysis using CO expanded liquid and hot water Nolen, S.; Lu, J.; Brown, J.; Pollet, P.; Eason, B.; Griffith, K.; Glaser, R.; Bush, D.; Lamb, D.; Eckert, C.; Liotta, C.; Thiele, G.; Bartels, K., Olefin Epoxidations Using Supercritical Carbon Dioxide and Hydrogen Peroxide Without Added Metallic
-
PROTECT YOUR INVESTMENT: Five factors to consider before making the switch to aftermarket oil
. such as: * Miscibility: The performance of a hydrofluorocarbon. (HFC) or carbon dioxide (CO2) system is optimized when. the lubricant and refrigerant mix to form a single, clear. phase (that is, they are miscible). Miscibility lowers the. viscosity of the lubricant carried through the system,. so the lubricant can