No.

w/h

Z 0

? eff( f = 0)

? r = 1

2.32

9.8

11.9

? r = 2.32

9.8

11.9

1

20.00

16.14

10.91

5.41

4.92

2.19

8.88

10.76

2

19.90

16.21

10.96

5.44

4.94

2.19

8.88

10.75

3

19.80

16.28

11.01

5.46

4.96

2.19

8.87

10.75

4

19.70

16.35

11.06

5.49

4.99

2.19

8.87

10.75

5

19.60

16.42

11.11

5.52

5.01

2.19

8.87

10.74

6

19.50

16.50

11.16

5.54

5.03

2.19

8.86

10.74

7

19.40

16.57

11.21

5.57

5.06

2.19

8.86

10.73

8

19.30

16.65

11.26

5.59

5.08

2.18

8.86

10.73

9

19.20

16.72

11.32

5.62

5.11

2.18

8.86

10.73

10

19.10

16.80

11.37

5.65

5.13

2.18

8.85

10.72

11

19.00

16.88

11.42

5.67

5.16

2.18

8.85

10.72

12

18.90

16.96

11.48

5.70

5.18

2.18

8.85

10.71

13

18.80

17.04

11.53

5.73

5.21

2.18

8.84

10.71

14

18.70

17.12

11.59

5.76

5.23

2.18

8.84

10.71

15

18.60

17.20

11.64

5.79

5.26

2.18

8.84

10.70

16

18.50

17.28

11.70

5.81

5.28

2.18

8.83

10.70

17

18.40

17.36

11.76

5.84

5.31

2.18

8.83

10.69

18

18.30

17.44

11.81

5.87

5.33

2.18

8.83

10.69

19

18.20

17.53

11.87

5.90

5.36

2.18

8.82

10.69

20

18.10

17.61

11.93

5.93

5.39

2.18

8.82

10.68

21

18.00

17.70

11.99

5.96

5.42

2.18

8.82

10.68

22

17.90

17.78

12.05

5.99

5.44

2.18

8.81

10.67

23

17.80

17.87

12.11

6.02

5.47

2.18

8.81

10.67

24

17.70

17.96

12.17

6.05

5.50

2.18

8.80

10.66

25

17.60

18.04

12.23

6.08

5.53

UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Category: Electrical Insulation and Dielectric Materials
Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.