Mild Corrosive Solutions Immersion Heaters
from WATTCO
Flanged heaters are commonly used in many chemical, petroleum and water based applications. Consisting normally of an ANSI rated flange with several hairpin elements or bugle tubular elements extending from the face of the flange, this electric heater uses direct heat application to the liquid... [See More]
- Applications: Food Equipment, Soap and Detergent Solutions, Freeze Protection; Clean Water Heating; Process Waters; Lightweight Oils & Degreasing Solutions; Medium Weight Oils; Mild Corrosive Solutions; Severe Corrosive Solutions
- AC Voltage Required: 208 to 600
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Watt Density: 8.8 to 67.8
from WATTCO
WATTCO ™ Pipe Heaters are especially constructed to fit inside standard 2 or 3 ” schedule 40 NPS pipes. These industrial tank heaters are specifically designed for usage in tanks that require extremely low watt densities such as waxes, thick liquids such as tar, molasses and corrosive... [See More]
- Applications: Lightweight Oils & Degreasing Solutions; Medium Weight Oils; Heavy Weight Oils; Mild Corrosive Solutions
- Phase: Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 0.0 to 750
- AC Voltage Required: 240 to 600
from WATTCO
Screw Plug heaters from WATTCO ™ consist of hairpin tubular elements that are brazed or welded into a machined pipe thread fitting, (normally an NPT fitting for North American standards) which are then screwed directly through a threaded coupling in the tank wall or vessel, or installed in... [See More]
- Applications: Food Equipment, Soap and Detergent Solutions, Freeze Protection; Clean Water Heating; Process Waters; Lightweight Oils & Degreasing Solutions; Medium Weight Oils; Heavy Weight Oils; Mild Corrosive Solutions; Severe Corrosive Solutions
- AC Voltage Required: 120 to 600
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Watt Density: 11 to 80
from Chromalox
Stainless Steel Sheath Elements (40 W/In ²). Stainless Steel Riser (36 and 48"). 120, 240 and 480V, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. For Mildly Corrosive Fluids. 2 Element 2 - 12 kW. 3 Element 3 - 18 kW. Third-party certifications: UL Listed, CSA [See More]
- Applications: Mild Corrosive Solutions
- AC Voltage Required: 120 to 480
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- kWatts: 2.00 to 18.00
from Process Heating Company, Inc.
The "Problem Solver" for underground tanks. Having trouble solving your underground storage tank problems? PHCo Lo-Density Drop-In Heater Kits have been designed for the heating of underground tanks and other applications that cannot be cut or welded on. These heaters can be used in multiples if... [See More]
- Applications: Ink, Asphalt, Pulp, & Construction; Clean Water Heating; Process Waters; Lightweight Oils & Degreasing Solutions; Medium Weight Oils; Heavy Weight Oils; Mild Corrosive Solutions; Severe Corrosive Solutions; Caustic Solutions; Liquid Paraffin
- Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage (optional feature)
- Maximum Operating (Sheath) Temperature: 750
- AC Voltage Required: 200 to 600
from Process Technology
Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Low watt densities of 18 watts/square inch (2.8 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]
- Applications: Most Aqueous Alkaline Solutions, Plating And Phosphate Tanks; Process Waters; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180
- AC Voltage Required: 120 to 600
from OMEGA Engineering, Inc.
Sturdy stainless steel .475" (1.2 cm) diameter elements, welded to steel flanges provide superior rigidity and strength. Heavy duty jumper straps and terminal parts assure permanent tightness of connections and an extra margin of current carrying capacity. Long life elements. High grade 304 series... [See More]
- Applications: Mild Corrosive Solutions
- AC Voltage Required: 240 to 480
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- kWatts: 3.00 to 36.00
from Heat Exchange & Transfer, Inc.
Flanged immersion heaters consist of a number of “U ” bend tubular heating elements welded into a standard ANSI pipe flange. Elements are supported with TEMA style baffles. A thermowell is installed through the center of the flange for the over temperature sensor. A NEMA rated enclosure... [See More]
- Applications: Gases/Vapors; Clean Water Heating; Process Waters; High Purity Waters; Lightweight Oils & Degreasing Solutions; Medium Weight Oils; Heavy Weight Oils; Mild Corrosive Solutions
- AC Voltage Required: 480
- Phase: Three Phase AC Voltage
- kWatts: 6.00
from Chromalox
2" NPT Stainless Steel Screw Plug. INCOLOY ® Sheath Elements. Medium Watt Density (23 W/In ²). 3 - 9 kW. Integral Thermostat (DPST). 120, 240 and 480 Volt, Three Phase. General Purpose or Moisture Resisant/Explosion Resistant Terminal Enclosure. Third-party certifications: UL Listed, CSA,... [See More]
- Applications: Mild Corrosive Solutions
- AC Voltage Required: 120 to 480
- Phase: Three Phase AC Voltage
- kWatts: 3.00 to 9.00
from Process Heating Company, Inc.
Flanged Immersion Heaters for use in tanks, large vats and reservoirs. These heaters consist of a standard 150# or 300# flange for mounting and PHCos exclusive heating elements. The elements are "dry well" and "low density" design. The dry wells allow the elements to be serviced or replaced without... [See More]
- Applications: Ink, Asphalt, Pulp, & Construction; Clean Water Heating; Process Waters; Lightweight Oils & Degreasing Solutions; Medium Weight Oils; Heavy Weight Oils; Mild Corrosive Solutions; Severe Corrosive Solutions; Caustic Solutions; Liquid Paraffin
- Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage (optional feature)
- Maximum Operating (Sheath) Temperature: 750
- AC Voltage Required: 200 to 600
from Process Technology
Customer designed specifically for phosphate coating applications. FEATURES. For use in iron, zinc and manganese phosphate tanks. Schedule 40, heavy wall, 316 stainless steel sheath withstands scaling better than traditional heaters. Low watt densities up to 23 watts/square inch (3.5 w/cm ²)... [See More]
- Applications: Iron, Zinc And Manganese Phosphate Tanks; Process Waters; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 230
- AC Voltage Required: 120 to 600
from OMEGA Engineering, Inc.
e PTH series models are heavy duty general purpose heaters for heating plating tanks, rinse tanks and other aqueous solutions. The Type 316 Stainless Steel is passivated to provide additional corrosion resistance. These heaters are equipped with a vapor tight terminal enclosure and a 3 foot long... [See More]
- Applications: Mild Corrosive Solutions
- AC Voltage Required: 120 to 480
- Phase: Single Phase AC Voltage
- kWatts: 5.00 to 7.50
from Heat Exchange & Transfer, Inc.
The UST (Unitary Storage Tank) heater is a completely packaged tank heating unit. The UST utilizes a flexible open coil heating element. The open coil heater consists of nickel chromium resistance coils supported in high temperature ceramic insulators on a flexible stainless steel strap. Each... [See More]
- Applications: Asphalt, Wax, Pitch, Creosote; Clean Water Heating; Process Waters; High Purity Waters; Lightweight Oils & Degreasing Solutions; Medium Weight Oils; Heavy Weight Oils; Mild Corrosive Solutions; Caustic Solutions; Liquid Paraffin
- AC Voltage Required: 120 to 600
- Phase: Three Phase AC Voltage
- kWatts: 10.00
from Chromalox
2" NPT Stainless Steel Passivated Screw Plug. Stainless Steel Passivated Sheath Elements. Medium Watt Density (23 W/In ²). 3 - 9 kW. Intgral Thermostat (DPST). 240 and 480 Volt, Three Phase. General Purpose or Moisture Resistant/Explosion Resistant Terminal Enclosure. Third-party... [See More]
- Applications: Mild Corrosive Solutions
- AC Voltage Required: 240 to 480
- Phase: Three Phase AC Voltage
- kWatts: 3.00 to 9.00
from Process Heating Company, Inc.
Heater elements are readily available in lengths from two feet to forty feet and can be custom sized to match both heating requirements and tank dimensions. Single and three-phase elements can be furnished. Elements are constructed of nickel chromium alloy coils that are supported by patented... [See More]
- Applications: Ink, Asphalt, Pulp, & Construction; Clean Water Heating; Process Waters; Lightweight Oils & Degreasing Solutions; Medium Weight Oils; Heavy Weight Oils; Mild Corrosive Solutions; Severe Corrosive Solutions; Caustic Solutions; Liquid Paraffin
- AC Voltage Required: 200 to 600
- Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage (optional feature)
from Process Technology
Durable, efficient chemical heater. FEATURES. 316 stainless steel or titanium elements for use in most aqueous alkaline solutions and rinse tanks. Watt densities of 45-55 watts/square inch for 316 stainless and <60 watts/square inch for titanium. Vapor resistant, flame retardant PVC terminal... [See More]
- Applications: Most Aqueous Alkaline Solutions And Rinse Tanks; Process Waters; Mild Corrosive Solutions; Severe Corrosive Solutions
- AC Voltage Required: 120 to 600
- Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage
- kWatts: 4.50 to 18.00
from OMEGA Engineering, Inc.
These over-the -side immersion heaters are designed for installing in the top of a tank with the heated portion directly immersed along the side or at the bottom. This provides easy removal of the heater and ample working space inside the tank. [See More]
- Applications: Mild Corrosive Solutions
- AC Voltage Required: 120 to 480
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- kWatts: 2.00 to 18.00
from Chromalox
2" NPT Stainless Steel Screw Plug. INCOLOY ® Sheath Elements. Medium Watt Density (23 W/In ²). 3 - 9 kW. Without Thermostat. 240 and 480 Volt, Three Phase. General Purpose, Moisture Resistant/Explosion Resistant Terminal Enclosure or Moisture Resistant. Third-party certifications: UL... [See More]
- Applications: Mild Corrosive Solutions
- AC Voltage Required: 240 to 480
- Phase: Three Phase AC Voltage
- kWatts: 3.00 to 9.00
from Process Heating Company, Inc.
No tanks to drain. Easily installed the heavy-duty assemblies weld directly into storage tanks to deliver long term and economical performance. Once installed, the flexible heater elements are removable from heater tubes without the need to drain the tank or disconnect fluid lines. LO-DENSITY IS A... [See More]
- Applications: Ink, Asphalt, Pulp, & Construction; Clean Water Heating; Process Waters; Lightweight Oils & Degreasing Solutions; Medium Weight Oils; Heavy Weight Oils; Mild Corrosive Solutions; Severe Corrosive Solutions; Caustic Solutions; Liquid Paraffin
- Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage (optional feature)
- Maximum Operating (Sheath) Temperature: 750
- AC Voltage Required: 200 to 600
from Process Technology
Compatible with many aggressive chemistries. FEATURES. Heavy wall fluoropolymer sheath (PTFE) covered stainless steel element reduces permeation. Low watt densities of 10 watts/square inch (1.5 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]
- Applications: Aggressive Chemistries; Mild Corrosive Solutions; Severe Corrosive Solutions
- AC Voltage Required: 120 to 480
- Phase: Single Phase AC Voltage
- kWatts: 1.00 to 6.00
from OMEGA Engineering, Inc.
•. All Passivated Stainless Steel Construction: Ideal for Mild Acid or Alkaline Solutions. •. Integral Thermostat. •. 208, 240, or 480 Vac, 1 phase. •. 43 to 51 W/in2 [See More]
- Applications: Mild Corrosive Solutions
- Phase: Single Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 250
- AC Voltage Required: 208 to 480
from Chromalox
2" NPT Stainless Steel Passivated Screw Plug. Stainless Steel Passivated Sheath Elements. Medium Watt Density (23 W/In ²). 3 - 9 kW. Without Thermostat. 240 and 480 Volt, Three Phase. General Purpose, Moisture Resistant/Explosion Resistant Terminal Enclosure or Moisture Resistant. Third-party... [See More]
- Applications: Mild Corrosive Solutions
- AC Voltage Required: 240 to 480
- Phase: Three Phase AC Voltage
- kWatts: 3.00 to 9.00
from Process Heating Company, Inc.
Rigid Tubular Drywell Heaters solve the problem of heating viscous products without damage to the product being heated. The Rigid Heaters can be installed as new or as replacement equipment for existing metal sheathed style tubular units that have higher watt density. Process Heatings Rigid Heaters... [See More]
- Applications: Ink, Asphalt, Pulp, & Construction; Clean Water Heating; Process Waters; Lightweight Oils & Degreasing Solutions; Medium Weight Oils; Heavy Weight Oils; Mild Corrosive Solutions; Severe Corrosive Solutions; Caustic Solutions; Liquid Paraffin
- Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage (optional feature)
- Maximum Operating (Sheath) Temperature: 750
- AC Voltage Required: 200 to 600
from Process Technology
Durable, efficient chemical heater. FEATURES. 316 stainless steel or titanium elements for use in most aqueous alkaline solutions and rinse tanks. Watt densities of 45-55 watts/square inch for 316 stainless and <60 watts/square inch for titanium. Vapor resistant, flame retardant PVC terminal... [See More]
- Applications: Most Aqueous Alkaline Solutions And Rinse Tanks; Process Waters; Mild Corrosive Solutions; Severe Corrosive Solutions
- AC Voltage Required: 208 to 600
- Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage
- kWatts: 2.00 to 18.00
from OMEGA Engineering, Inc.
bull;. NEMA 1 Rated, E1 General Purpose Enclosure or Moisture Resistant/Explosion Resistant Enclosure. •. Premium Quality Stainless Steel Screw Plug. •. 240 and 480V, 3 Phase. •. 3 to 18 kW. •. Incoloy Sheath Provides Excellent Corrosion Resistance for Solution Water... [See More]
- Applications: Mild Corrosive Solutions
- AC Voltage Required: 240 to 480
- Phase: Three Phase AC Voltage
- kWatts: 3.00 to 18.00
from Chromalox
General Purpose, Moisture Resistant or Moisture Resistant/Explosion Resistant Terminal Enclosure. Stainless Steel Thermowell. 45 W/In ². 6 - 200 kW. Third-party certifications: UL Listed, CSA, cCSAus. General Purpose, Moisture Resistant or Moisture Resistant/Explosion Resistant Terminal... [See More]
- Applications: Mild Corrosive Solutions
- AC Voltage Required: 240 to 480
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- kWatts: 3.00 to 50.00
from Process Heating Company, Inc.
Unitized Heaters remain Process Heating Company's best selling product line. Its popularity continues due to the ease of installation into any tank or vat; its 100% efficiency; its ease of automation; its lack of maintenance and remarkable reliability. The Lo-Density Unitized Heater dissipates as... [See More]
- Applications: Ink, Asphalt, Pulp, & Construction; Clean Water Heating; Process Waters; Lightweight Oils & Degreasing Solutions; Medium Weight Oils; Heavy Weight Oils; Mild Corrosive Solutions; Severe Corrosive Solutions; Caustic Solutions; Liquid Paraffin
- Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage (optional feature)
- Maximum Operating (Sheath) Temperature: 750
- AC Voltage Required: 200 to 600
from Process Technology
Durable, efficient chemical heater. FEATURES. 304 stainless, 316 stainless steel or titanium elements for use in most aqueous alkaline solutions and plating and phosphate tanks. Watt densities up to 35 watts/square inch (5.4 w/cm ²). Vapor resistant, flame retardant PVC terminal enclosure with... [See More]
- Applications: Most Aqueous Alkaline Solutions, Plating And Phosphate Tanks; Process Waters; Mild Corrosive Solutions; Severe Corrosive Solutions
- AC Voltage Required: 120 to 600
- Phase: Single Phase AC Voltage; Three Phase AC Voltage (optional feature)
- kWatts: 1.00 to 12.00
from OMEGA Engineering, Inc.
•. Durable Incoloy Sheath for Superior Corrosion Protection. •. 2" NPT Stainless Steel Screw Plug. •. 120, 240, 480 V, 1 Phase Power. •. General Purpose-UL Listed Enclosure or Moisture Resistant/Explosion Resistant Enclosure. •. 1.5 to 15kW [See More]
- Applications: Mild Corrosive Solutions
- AC Voltage Required: 120 to 480
- Phase: Single Phase AC Voltage
- kWatts: 1.50 to 15.00
from Chromalox
LTFX units provide low watt density heating over a large surface area, while providing precise temperature control for such materials as fire water storage, asphalt, diesel, lube oils, ethanol, bio-diesel, glycerin, animal fats, vegetable oils, fuel oils, or similar types of liquids. 4 - 240 kW Unit... [See More]
- Applications: Clean Water Heating; Process Waters; Lightweight Oils & Degreasing Solutions; Medium Weight Oils; Heavy Weight Oils; Mild Corrosive Solutions; Severe Corrosive Solutions; Liquid Paraffin
- AC Voltage Required: 480 to 600
- Phase: Three Phase AC Voltage
- kWatts: 4.00 to 240.00
from Process Technology
Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Watt densities up to 40 watts/square inch (6.2 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]
- Applications: Most Aqueous Alkaline Solutions And Rinse Tanks; Process Waters; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180
- AC Voltage Required: 200 to 600
from Chromalox
STFX units provide replaceable-element design in a compact setting, while providing precise temperature control. Units comply with API- 614 and can be used for such materials as lube oil, fire water storage, water solutions, asphalt, water/glycol, diesel, acidic solutions, ethanol, bio-diesel... [See More]
- Applications: Clean Water Heating; Process Waters; Lightweight Oils & Degreasing Solutions; Medium Weight Oils; Heavy Weight Oils; Mild Corrosive Solutions; Severe Corrosive Solutions; Liquid Paraffin
- AC Voltage Required: 240 to 600
- Phase: Three Phase AC Voltage
- kWatts: 1.00 to 25.00
from Process Technology
Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in 316 stainless steel. Watt densities up to 40 watts/square inch (6.2 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. Grounded... [See More]
- Applications: Most Aqueous Alkaline Solutions And Rinse Tanks; Process Waters; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180
- AC Voltage Required: 200 to 600
from Process Technology
Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Watt densities up to 35 watts/square inch (5.4 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]
- Applications: Most Aqueous Alkaline Solutions And Rinse Tanks; Process Waters; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180
- AC Voltage Required: 240 to 600
from Process Technology
Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Watt densities up to 40 watts/square inch (6.2 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]
- Applications: Most Aqueous Alkaline Solutions, Electroplating And Rinse Tanks; Process Waters; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180
- AC Voltage Required: 240 to 600
from Process Technology
Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in 316 stainless steel. Watt densities up to 40 watts/square inch (6.2 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. Grounded... [See More]
- Applications: Most Aqueous Alkaline Solutions And Rinse Tanks; Process Waters; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180
- AC Voltage Required: 200 to 600
from Process Technology
Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Low watt densities of 18 watts/square inch (2.8 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]
- Applications: Most Aqueous Alkaline Solutions, Plating And Phosphate Tanks; Process Waters; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage; Three Phase AC Voltage (optional feature)
- Maximum Operating (Sheath) Temperature: 180
- AC Voltage Required: 120 to 600
from Process Technology
Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Low watt densities of 18 watts/square inch (2.8 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]
- Applications: Most Aqueous Alkaline Solutions, Plating And Phosphate Tanks; Process Waters; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180
- AC Voltage Required: 120 to 600
from Process Technology
Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). 4 foot (1.2m) continuous fluoropolymer (PTFE) cable leading to a vapor resistant... [See More]
- Applications: Aggressive Acids; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 212
- AC Voltage Required: 120 to 600
from Process Technology
Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m)... [See More]
- Applications: Aggressive Acids; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 212
- AC Voltage Required: 120 to 600
from Process Technology
Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m)... [See More]
- Applications: Chemicals; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 212
- AC Voltage Required: 120 to 600
from Process Technology
Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m)... [See More]
- Applications: Chemicals; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 212
- AC Voltage Required: 120 to 600
from Process Technology
Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m)... [See More]
- Applications: Chemicals; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 212
- AC Voltage Required: 120 to 600
from Process Technology
Durable, efficient chemical heater. FEATURES. Heavy wall fluoropolymer sheath (PTFE) covered stainless steel element reduces permeation. Low watt density design 10 watts/square inch (1.5 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC... [See More]
- Applications: Chemicals; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 212
- AC Voltage Required: 120 to 600
from Process Technology
Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). 4 foot (1.2m) continuous fluoropolymer (PTFE) cable leading to a vapor resistant... [See More]
- Applications: Aggressive Acids; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 212
- AC Voltage Required: 120 to 600
from Process Technology
Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). 4 foot (1.2m) continuous fluoropolymer (PTFE) cable leading to a vapor resistant... [See More]
- Applications: Aggressive Acids; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 212
- AC Voltage Required: 120 to 600
from Process Technology
Designed for the most demanding chemical applications and to provide years of trouble-free performance. FEATURES. Constructed with our exclusive patented N2 “purged ” elements for extended service life. High efficiency in a compact design, and an excellent alternative for replacing strip... [See More]
- Applications: Chemicals; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 266
- AC Voltage Required: 120 to 600
from Process Technology
Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m)... [See More]
- Applications: Aggressive Acids; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 212
- AC Voltage Required: 120 to 600
from Process Technology
Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). 4 foot (1.2m) continuous fluoropolymer (PTFE) cable leading to a vapor resistant... [See More]
- Applications: Aggressive Acids; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 212
- AC Voltage Required: 120 to 600
from Process Technology
Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). 4 foot (1.2m) continuous fluoropolymer (PTFE) cable leading to a vapor resistant... [See More]
- Applications: Chemicals; Mild Corrosive Solutions; Severe Corrosive Solutions
- Phase: Single Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 212
- AC Voltage Required: 120 to 600