X-Ray Radiation Detectors
from Teledyne DALSA
Teledyne DALSA's Rad-icon product family of large-area digital X-ray detectors offers users a high-speed, high-performance X-ray imaging detector with a fast, reliable PC interface (Camera Link) for easy integration. The Rad-icon product line leverages Teledyne DALSA's advanced CMOS image sensing... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Computer Interface Options: Serial Interface
- Computer Interface: Computer Interface
- Operating Temp: 50 to 104
from Electro Optical Components, Inc.
CVD diamond is used as a radiation detector for medical and high energy physics applications. Major fields of application include medical dositry, neutron detectors, UV laser systems and X-ray and gamma detection. HIGH purity synthetic CVD Diamond presents unique characteristics that make it an... [See More]
- Types of Ionizing Radiation Detected: Alpha Particles; Beta Particles; Gamma Ray; X-Ray; Neutron
- Detectable Activity Range: 1 to 5500
- Detector Style: Fixed Installation
from Hamamatsu Photonics
CsI(Tl) + Aluminum plate, High light output [See More]
- Types of Ionizing Radiation Detected: X-Ray
from Teledyne DALSA
Teledyne DALSA ’s Rad-Xcam performance exceeds the existent industry benchmarks for legacy amorphous silicon and emerging IGZO technologies by providing higher frame rates and image quality at low dose, lower lag and increased signal-to-noise ratio. The Rad-Xcam detectors are designed to... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Computer Interface: Computer Interface
- Detector Style: Fixed Installation
from Hamamatsu Photonics
High accuracy, High sensitivity, compact radiation detection module. The C12137 series is a radiation detection module containing a scintillator and MPPC (multi-pixel photon counter) designed to detect gamma rays from 137Cs (Cesium-137) and the like. The scintillator converts incident gamma rays... [See More]
- Types of Ionizing Radiation Detected: X-Ray
from Teledyne DALSA
X-ray Imaging in the Least Accessible Spaces. The RadEye XR is an ultra-high resolution industrial dynamic detector. The RadEye XR detectors are designed to address the most demanding needs of Industrial inspection, biomedical and scientific applications. The CameraLink HS ™ interface allows... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Type of Monitoring: For Area Monitoring
- Types of Radiation Detectors: Scintillation Detector
- Computer Interface: Computer Interface
from Hamamatsu Photonics
High accuracy, High sensitivity, compact radiation detection module. The C12137 series is a radiation detection module containing a scintillator and MPPC (multi-pixel photon counter) designed to detect gamma rays from 137Cs (Cesium-137) and the like. The scintillator converts incident gamma rays... [See More]
- Types of Ionizing Radiation Detected: X-Ray
from Teledyne DALSA
The Remote RadEye HR x-ray detector is a slim, lightweight, rugged solution for high-resolution radiation imaging. The detector is suitable for industrial inspection applications where images are taken in tight or difficult-to-reach spaces. [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Computer Interface: Computer Interface
- Detector Style: Portable Detector
- Computer Interface Options: Serial Interface
from Hamamatsu Photonics
High accuracy, High sensitivity, compact radiation detection module. The C12137 series is a radiation detection module containing a scintillator and MPPC (multi-pixel photon counter) designed to detect gamma rays from 137Cs (Cesium-137) and the like. The scintillator converts incident gamma rays... [See More]
- Types of Ionizing Radiation Detected: X-Ray
from Teledyne DALSA
Teledyne Rad-icon ’s Shad-o-Box HS product family of digital x-ray cameras offers users a high-speed, high-performance CMOS x-ray imaging detector with a fast, reliable Gigabit Ethernet interface. The cameras in this product line are capable of frame rates up to 66 fps, and communicate via a... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Types of Radiation Detectors: Scintillation Detector
- Detector Style: Portable Detector
- Detectable Activity Range: 10 to 225
from Hamamatsu Photonics
High accuracy, High sensitivity, compact radiation detection module. The C12137 series is a radiation detection module containing a scintillator and MPPC (multi-pixel photon counter) designed to detect gamma rays from 137Cs (Cesium-137) and the like. The scintillator converts incident gamma rays... [See More]
- Types of Ionizing Radiation Detected: X-Ray
from Hamamatsu Photonics
High accuracy, High sensitivity, compact radiation detection module. The C12137 series is a radiation detection module containing a scintillator and MPPC (multi-pixel photon counter) designed to detect gamma rays from 137Cs (Cesium-137) and the like. The scintillator converts incident gamma rays... [See More]
- Types of Ionizing Radiation Detected: X-Ray
from First Sensor AG
Alpha, beta, gamma, and X-ray radiation can be detected with silicon PIN photodiodes either directly via the absorption in the crystal lattice or indirectly via the measurement of the luminescence radiation of a scintillation crystal. The Series X from First Sensor features optimized silicon PIN... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Types of Radiation Detectors: Semiconductor Diode Detector
- Detector Style: Detector Sensing Element Only
- Operating Temp: 14 to 140
from MOXTEK, Inc.
Our MXDPP-50 Digital Pulse Processor (DPP) is ideal for analytical x-ray and gamma-ray instruments such as; Silicon Drift Detector (SDD), Si-PIN, CdTe, Si(Li), and Ge detectors. MXDPP-50 is designed to digitize detector output signals, achieving high throughput, with excellent pile-up rejection. Our... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Computer Interface: Computer Interface
- Detector Style: Detector Sensing Element Only; Portable Detector
- Computer Interface Options: Serial Interface
from Hitachi High Technologies America, Inc.
Vortex ® Silicon Drift Detectors X-ray detectors feature active areas between 30 mm2 and 80 mm2. Vortex ® detectors are produced from high purity silicon using state-of-the-art CMOS production technology. They feature excellent energy resolution ( <130 eV FWHM at Mn K α is typical)... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Types of Radiation Detectors: Dosimeter
- Detector Style: Fixed Installation
from Oxford Instruments
Ultim Extreme Silicon Drift Detector is a breakthrough solution for ultra high resolution FEG-SEM applications and delivers solutions beyond conventional micro- and nano-analysis. The Ultim Extreme is a windowless 100 mm2 version of Ultim designed to maximize sensitivity and spatial resolution. It... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Computer Interface: Computer Interface
- Detector Style: Fixed Installation
from Ultra Energy
Custom built facility from which we design, manufacture, test and support neutron flux detectors. [See More]
- Types of Ionizing Radiation Detected: Gamma Ray; X-Ray; Neutron
- Detector Style: Fixed Installation
from Mirion Technologies
Our organization is comprised of over 1000 talented professionals, passionate about delivering world class products, services, and solutions in the world of radiation detection and protection. From our 13 operating facilities across North America, Europe, and Asia, Mirion Technologies offers... [See More]
- Types of Ionizing Radiation Detected: Beta Particles; Gamma Ray; X-Ray; Neutron
- Types of Radiation Detectors: Dosimeter
- Detector Style: Fixed Installation; Portable Detector
- Detectable Activity Range: 0.0150 to 25
from Landauer, Inc.
LANDAUER dosimeters feature our proprietary OSL dosimetry technology, and can be packaged for occupational radiation monitoring, area radiation monitoring, patient monitoring, emergency response or other services for healthcare. [See More]
- Types of Ionizing Radiation Detected: Beta Particles; Gamma Ray; X-Ray
- Types of Radiation Detectors: Dosimeter
- Detector Style: Portable Detector
- Detector Output: Dose
from Sentinel
Direct gamma and x-ray dosimeter. 0 - 200 mR Measuring range. Temperature Range: -20 to 50 °C [See More]
- Types of Ionizing Radiation Detected: Gamma Ray; X-Ray
- Types of Radiation Detectors: Dosimeter
- Detector Style: Portable Detector
- Detector Output: Dose
from MOXTEK, Inc.
The XPIN ® detector is Moxtek ’s best performing Si-PIN detector. XPIN detectors use a silicon PIN diode, multi-layer collimator, and thin DuraBeryllium ® window, achieving great resolution and x-ray sensitivity. The XPIN preamp provides a low-noise signal output to an analog or... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Detector Style: Detector Sensing Element Only; Portable Detector
from Hitachi High Technologies America, Inc.
Vortex ®-60EX silicon drift X-ray detectors feature active areas between 30 mm2 and 80 mm2. Vortex ®-60EX detectors are produced from high purity silicon using state-of-the-art CMOS production technology. They feature excellent energy resolution ( <130 eV FWHM at Mn K α is typical)... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Types of Radiation Detectors: Dosimeter
- Detector Style: Fixed Installation
from Oxford Instruments
Ultim Max is the next generation of Silicon Drift Detectors (SDD). Combining the largest sensor sizes with Extreme electronics to deliver unparalleled speed and sensitivity. The large SDD sensors of Ultim Max allows up to 17x more data to be collected in the same time with no loss of accuracy. [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Computer Interface: Computer Interface
- Detector Style: Fixed Installation
from Sentinel
Rugged, watertight, dustproof radiographic survey meter. Two piece nylon reinforced fiberglass case. Large 3.5 in Mil-Spec meter indicator. Meter face in both mR/hr and uSv/hr. Three Ranges: 0 to 10, 0 to 100 and 0 to1000 mR/hr [See More]
- Types of Ionizing Radiation Detected: Gamma Ray; X-Ray
- Detector Output: Dose Rate
- Detector Style: Portable Detector
- Dose Rate (e.g.: sieverts/hour, rem/hour/ R/hour): 0 to 1000mR/hr
from MOXTEK, Inc.
The XPIN ® detector is Moxtek ’s best performing Si-PIN detector. XPIN detectors use a silicon PIN diode, multi-layer collimator, and thin DuraBeryllium ® window, achieving great resolution and x-ray sensitivity. The XPIN preamp provides a low-noise signal output to an analog or... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Detector Style: Detector Sensing Element Only; Portable Detector
from Hitachi High Technologies America, Inc.
Vortex ®-EX silicon drift X-ray detectors feature active areas between 30 mm2 and 80 mm2. Vortex ®-90EX detectors are produced from high purity silicon using state-of-the-art CMOS production technology. They feature excellent energy resolution ( <130 eV FWHM at Mn K α is typical)... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Types of Radiation Detectors: Dosimeter
- Detector Style: Fixed Installation
from Oxford Instruments
Ultim Max TEM, our SDD detector for nanoscale analysis and elemental mapping in the TEM. Using a new low-profile 80 mm2 sensor gets closer to the specimen delivering more x-ray counts under any condition. Combined with a windowless construction and extreme electronics this detector delivers... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Computer Interface: Computer Interface
- Detector Style: Fixed Installation
from Sentinel
Portable 12 V DC area monitor with battery charger. Standard trip point set at 2mR/hr. Audio piezo alert. Large red strobe warning light [See More]
- Types of Ionizing Radiation Detected: Gamma Ray; X-Ray
- Detector Output: Dose Rate
- Detector Style: Fixed Installation
- Type of Monitoring: For Area Monitoring
from Hitachi High Technologies America, Inc.
Vortex ®-EM silicon drift X-ray detectors feature active areas between 30 mm2 and 80 mm2. Vortex ®-EM detectors are produced from high purity silicon using state-of-the-art CMOS production technology. They feature excellent energy resolution ( <130 eV FWHM at Mn K α is typical) and... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Types of Radiation Detectors: Dosimeter
- Detector Style: Fixed Installation
from Oxford Instruments
Ultim Max TLE, our flagship SDD detector for TEM. This detector is optimized to offer elemental characterization at the atomic scale delivering maximum count rates at minimum probe sizes. This performance is achieved using an optimized shape, 100 mm2 sensor, windowless construction, optimized... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Computer Interface: Computer Interface
- Detector Style: Fixed Installation
from Sentinel
Radiography ranges: 0 to 50 and 0 to 500 mR/hr. X-ray ranges: 0 to 5 and 0 to 50 mR/hr. 120V AC Dual range area monitor with selectable alarm trip points. Two 120V AC remote alarm trip outlets [See More]
- Types of Ionizing Radiation Detected: Gamma Ray; X-Ray
- Detector Output: Dose Rate
- Detector Style: Fixed Installation
- Dose Rate (e.g.: sieverts/hour, rem/hour/ R/hour): 0 to 500 mR/hr
from Hitachi High Technologies America, Inc.
Vortex ®-EZ silicon drift X-ray detectors feature active areas between 30 mm2 and 80 mm2. Vortex ®-EZ detectors are produced from high purity silicon using state-of-the-art CMOS production technology. They feature excellent energy resolution ( <140 eV FWHM at Mn K α is typical) and... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Types of Radiation Detectors: Dosimeter
- Detector Style: Fixed Installation
from Oxford Instruments
The x-act is a fully quantitative SDD with excellent performance at low and high count rates. It provides all the benefits of Oxford Instruments' renowned technology in a package that is suitable for applications that do not demand the full performance of the large area X-MaxN detectors. x-act... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Computer Interface: Computer Interface
- Detector Style: Fixed Installation
from Sentinel
Die cast aluminum belt worn rate alarm. Alarms at 500 mR + 20%. 24 Turn calibration potentiometer [See More]
- Types of Ionizing Radiation Detected: Gamma Ray; X-Ray
- Detector Output: Dose Rate
- Detector Style: Portable Detector
- Type of Monitoring: For Personnel Monitoring
from Hitachi High Technologies America, Inc.
Vortex ®-ME3 is a three-element silicon drift detector (SDD) X-ray detection system with a total active area of 90 mm ² - 150 mm ². The Vortex ®-ME3 offers superior energy resolution and high throughput performance to enhance the total analytical performance of the X-ray... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Types of Radiation Detectors: Dosimeter
- Detector Style: Fixed Installation
from Oxford Instruments
Windowless Detector Windowless detectors provide more counts at all energies with unrivalled low energy performance. Collection efficiency is significantly improved compared to detectors of a similar solid angle that need to use a thin window. Sensitivity to N Ka is increased almost 3x Sensitivity... [See More]
- Types of Ionizing Radiation Detected: X-Ray
- Computer Interface: Computer Interface
- Detector Style: Fixed Installation
from Sentinel
FEATURES. Rugged and Reliable. Nylon holster or optional see-through holster. Removable rubber sleeve for extra protection. Water resistant. Low power technology (600 hour operation). LCD Screen can be rotated 180o. Battery life indicator. Large display with backlight. Top alarm indication (Can be... [See More]
- Types of Ionizing Radiation Detected: Gamma Ray; X-Ray
- Types of Radiation Detectors: Geiger-Mueller Counter; Dosimeter
- Detector Style: Portable Detector
- Detectable Activity Range: 0.0013 to 45