Video Display Terminal Moisture Meters
from Panametrics
GE ’s Optica Series chilled mirror hygrometers offer National Institute of Standards and Technologies (NIST) —traceable humidity, temperature and pressure measurements for the connected generation. Now data is accessible from anywhere, any time, from within a browser over the Internet or... [See More]
- Display: Video Display Terminal
- Form Factor: Instrument
- Variables Measured: DewPoint; Pressure; Temperature
- Dew Point Range: -112 to 185
from Panametrics
Panametrics OptiSonde hygrometer precisely analyzes humidity and temperature using chilled mirror sensing technology. This humidity analyzer is the perfect sensor of choice for laboratory and process measurements that require high precision without long-term drift. Key Benefits: Chilled mirror... [See More]
- Display: Video Display Terminal
- Form Factor: Instrument
- Variables Measured: DewPoint; Pressure; Temperature
- Dew Point Range: -103 to 167
from Panametrics
Features. air.IQ simplifies the selection and installation of your moisture analyzer. Install the moisture probe, wire your power and outputs to the terminal strip, and connect your gas to the inlet fitting. Wall mounted NEMA 4X package. Includes the analyzer display, moisture probe, interconnecting... [See More]
- Display: Video Display Terminal
- Form Factor: Instrument
- Variables Measured: DewPoint
- Dew Point Range: -166 to 140
from Panametrics
Our TDLS moisture analyzer, Aurora, provides moisture measurements from low PPM to high percentage levels. Its accurate measurements detect moisture in many applications such as natural gas TEG dehydration, natural gas storage, transmission and custody transfer, carbon dioxide for enhanced oil... [See More]
- Display: Video Display Terminal
- Form Factor: Analyzer
- Variables Measured: Absolute Humidity; DewPoint
- Absolute Humidity Range: 0.0015 to 3.8
from Panametrics
Features. Rack, bench, panel, and wall mount configurations. NEMA 4 weatherproof membrane front display/keypad. M Series or IQ.probe moisture probe compatible. Displays moisture content in dew/ frost point and ppmv. Built-in isolated current or voltage analog output. Fail-safe fault alarm relay. Two... [See More]
- Display: Video Display Terminal
- Form Factor: Instrument
- Variables Measured: DewPoint
- Dew Point Range: -166 to 140
from LufftUSA
Description: X-pert range for humidity and temperature measurements in climate and environmental technology. Supplementary description: Temperature and humidity measuring device compatible with various intelligent sensors. [See More]
- Display: Video Display Terminal
- Form Factor: Meter
- Variables Measured: Relative Humidity; DewPoint; Temperature
- Application: Moisture / Water Content in Gases / Air
from KPM Analytics
A Simple On-Line Web Scanner for Fewer Products & Zones. The Guardian-HD Basic Web Profile Analyzer is a single-scanner system to measure moisture, coat weight, and temperature (optional) for all paper, film, and web-converting processes. Entry-level functionality for operators to run simple... [See More]
- Display: Video Display Terminal
- Form Factor: Analyzer
- Variables Measured: Moisture Content
- Moisture Content Range: 0.1000 to 95
from MBW Calibration AG
The 373 is a de-facto standard in humidity measurement for over 15 years. Incremental development based on operational experience and customer feedback means that the 373 continues to meet the expectations of hundreds of users in some of the most challenging applications. Despite its high... [See More]
- Display: Video Display Terminal
- Form Factor: Instrument
- Variables Measured: DewPoint; Temperature
- Dew Point Range: -139 to 203
from Mesa Systems Company
Battery powered, portable, handheld meter, mobile, inexpensive [See More]
- Display: Video Display Terminal
- Form Factor: Meter
- Variables Measured: Moisture Content
- Moisture Content Range: 0.0 to 100
from LufftUSA
High-precision reference measurement standard for industrial humidity calibrations. High-precision reference measurement standard for industrial humidity calibrations. Suitable as humidity reference in climate chambers or humidity generators. Mini USB interface with software, online data collection. [See More]
- Display: Video Display Terminal
- Form Factor: Meter
- Variables Measured: Relative Humidity; DewPoint; Temperature
- Application: Moisture / Water Content in Gases / Air
from KPM Analytics
Product Overview. Moisture, Protein, and/or Oil Analysis in 30 Seconds. Trusted by thousands of quality assurance experts around the world, the SpectraStar ™ XT-3 offers accurate and reliable measurements of moisture, protein, and/or oil (fat) for both laboratory and at-line applications in... [See More]
- Display: Video Display Terminal
- Form Factor: Analyzer
- Variables Measured: Moisture Content
- Moisture Content Accuracy: 0.2000
from MBW Calibration AG
The 473 is the lowest cost MBW dew point instrument, yet it has high performance and the same user interface as its more expensive siblings. It features cable mounted dew point measuring heads that allow the user to measure directly within the application environment, and includes a temperature... [See More]
- Display: Video Display Terminal
- Form Factor: Instrument
- Variables Measured: DewPoint; Temperature
- Dew Point Range: -4 to 158
from LufftUSA
Description: The powerful and compact handheld device with state-of-the-art and robust design. Excellent accuracy. The high-resolution color screen displays rel. humidity, temperature and dew point. Excellent readability. The calibration function (offset correction) guarantees the long-term use... [See More]
- Display: Video Display Terminal
- Form Factor: Meter
- Variables Measured: Relative Humidity; DewPoint; Temperature
- Relative Humidity Range: 0.0 to 100
from KPM Analytics
The Instant Moisture Profiling System (IMPS) is a non-contact RF moisture profiling system, typically used in board manufacturing plants, built in a customizable multi-sensor arrayed framework. [See More]
- Display: Video Display Terminal
- Form Factor: Analyzer
- Variables Measured: Moisture Content
- Moisture Content Range: 0.0 to 25
from MBW Calibration AG
The 473-RP2 is a probe type dew point mirror that is suitable for insertion in to test chambers or environments with moving air. It is particularly well suited for use in relative humidity generators where it functions is a calibration transfer standard for dew/frost point, relative humidity and... [See More]
- Display: Video Display Terminal
- Form Factor: Instrument
- Variables Measured: DewPoint; Temperature
- Dew Point Range: -4 to 158
from LufftUSA
Description: The powerful and compact handheld device with state-of-the-art and robust design. Excellent accuracy. The high-resolution color screen displays rel. humidity, temperature and dew point. Excellent readability. The calibration function (offset correction) guarantees the long-term use... [See More]
- Display: Video Display Terminal
- Form Factor: Meter
- Variables Measured: Relative Humidity; DewPoint; Temperature
- Relative Humidity Range: 0.0 to 100
from KPM Analytics
Product Overview. Continuous Monitoring of Moisture, Oil/Fat & Product Temperature. The MCT466-SF is designed for demanding environmental conditions in food and snack food manufacturing. These sensors are being used at many of the largest food manufacturing plants in the world. They help... [See More]
- Display: Video Display Terminal
- Form Factor: Analyzer
- Variables Measured: Moisture Content
- Moisture Content Range: 0.1000 to 60
from MBW Calibration AG
The 473-SH2 is a chilled mirror dew point hygrometer with a cable mounted measuring head with an integrated sample flow control fan and high precision temperature measurement. It is particularly well suited for use in climatic chambers or humidity generators where it functions is a calibration... [See More]
- Display: Video Display Terminal
- Form Factor: Instrument
- Variables Measured: DewPoint; Temperature
- Dew Point Range: -4 to 158
from LufftUSA
Description: The most precice and flexible all-rounder instrument for professional applications-easy to handle and robust. Allows various intelligent sensors to be connected with automatic recognition, saves measuring campaignes, allows all climate data to be calculated and archieved on a computer... [See More]
- Display: Video Display Terminal
- Form Factor: Meter
- Variables Measured: Relative Humidity; DewPoint; Pressure; Temperature
- Technology: Strain Gauge / Piezoresistive
from MBW Calibration AG
The SHX measuring head is an evolution of the tried and tested SH measuring head. It is able to operate in test conditions up to 125 °C thanks to the use of optical components, electronics and materials that are able to withstand high temperatures. Our development team tested a range of... [See More]
- Display: Video Display Terminal
- Form Factor: Instrument
- Variables Measured: DewPoint; Temperature
- Dew Point Range: -4 to 158