CANbus Programmable Logic Controllers (PLC)

30 Results
Programmable controller for mobile machines -- CR0133
from ifm efector inc.

For complex control functions in vehicles and mobile machines. With many multifunctional configurable input and output channels. High-performance CAN interfaces for various communication tasks. Protection rating for the requirements of mobile machines. Freely programmable to IEC 61131-3 with CODESYS... [See More]

  • Network Options: CANbus
  • Input: Analog Input; Frequency or Pulse; Resistance
  • Maximum Channels: 64
  • Output: Analog Output; Frequency or Pulse; Digital
PLCs - Programmable Logic Controllers -- 1244307
from RS Components, Ltd.

BARTH 0850-0560 PLC I/O Module [See More]

  • Network Options: CANbus; Canopen
  • Outputs: 5
  • Inputs: 5
  • Input: Analog Input; Analogue, digital
Codesys PLC Controller EtherCAT and CANOpen Protocol RTC -- C4374
from Sichuan Odot Automation System Co., Ltd.

The C4374 follows the IEC61131-3 international standard programmable logic controller, supports ladder diagram (LD), instruction list (IL), structured text (ST), function block diagram (CFC/FBD), sequential function chart (SFC) five programming languages, user program storage supports 4 Mbytes, data... [See More]

  • Network Options: CANbus
  • Baud Rate: 115200
  • Computer Interface Options: Single Serial Interface; 3*RJ45,1*RS485,1*CAN
  • Program Languages: IEC61131-3; IEC61131-3(LD、IL、ST、CFC/FBD、SFC)
Programmable controller for mobile machines -- CR0403
from ifm efector inc.

For simple control functions in vehicles and mobile machines. With many multifunctional configurable input and output channels. High-performance CAN interfaces for various communication tasks. For use in driver's cabin and control cabinet. Freely programmable to IEC 61131-3 with CODESYS 2.3. From... [See More]

  • Network Options: CANbus
  • Input: Analog Input; Frequency or Pulse; Resistance
  • Maximum Channels: 24
  • Output: Analog Output; Frequency or Pulse; Digital
PLCs - Programmable Logic Controllers -- 1244308
from RS Components, Ltd.

BARTH 0850-0660 PLC I/O Module [See More]

  • Network Options: CANbus; Canopen
  • Outputs: 9
  • Inputs: 10
  • Input: Analog Input; Analogue, digital
Programmable controller for mobile machines -- CR0431
from ifm efector inc.

For simple control functions in vehicles and mobile machines. With many multifunctional configurable input and output channels. High-performance CAN interfaces for various communication tasks. For use in driver's cabin and control cabinet. Freely programmable to IEC 61131-3 with CODESYS 2.3. From... [See More]

  • Network Options: CANbus
  • Input: Analog Input; Frequency or Pulse; Resistance
  • Maximum Channels: 14
  • Output: Relay Output; Analog Output
PLCs - Programmable Logic Controllers -- 1348863
from RS Components, Ltd.

BARTH 0850-0800 PLC I/O Module [See More]

  • Network Options: CANbus; Canopen
  • Outputs: 9
  • Inputs: 5
  • Input: Analog Input; Analogue, digital
Programmable controller for mobile machines -- CR0708
from ifm efector inc.

powerful 32 bit triple core controllers with large application memory. With many multifunctional configurable inputs and outputs. High-performance CAN and Ethernet interfaces for various communication tasks. Freely programmable to IEC 61131-3 with CODESYS 3.5. From May 1st 2025, products produced in... [See More]

  • Network Options: Ethernet; CANbus; CANopen; SAE J1939; free protocol
  • Input: Analog Input; Frequency or Pulse; Resistance
  • Maximum Channels: 37
  • Output: Analog Output; Frequency or Pulse; Digital
PLCs - Programmable Logic Controllers -- 1348867
from RS Components, Ltd.

BARTH 0850-0820 PLC I/O Module [See More]

  • Network Options: CANbus; Canopen
  • Outputs: 9
  • Inputs: 3
  • Input: Analog Input; Analogue
Programmable controller for mobile machines -- CR2530
from ifm efector inc.

For complex control functions in vehicles and mobile machines. With many multifunctional configurable input and output channels. High-performance CAN interfaces for various communication tasks. Protection rating for the requirements of mobile machines. Freely programmable to IEC 61131-3 with CODESYS... [See More]

  • Network Options: CANbus
  • Input: Analog Input; Frequency or Pulse; Resistance
  • Maximum Channels: 32
  • Output: Analog Output; Frequency or Pulse; Digital
PLCs - Programmable Logic Controllers -- 8066758 [TM251MESC from Schneider Electric]
from RS Components, Ltd.

Schneider Electric TM251MESC [See More]

  • Network Options: CANbus; Ethernet, modbus, profibus dp, usb
  • Output: Frequency or Pulse; Pulse
  • Input: Analog Input; Analogue
  • Programming Options: Mini usb
Programmable controller for mobile machines -- CR403S
from ifm efector inc.

Freely programmable to IEC 61131-3 with CODESYS 3.5. High-performance CAN interface for various communication tasks. Multifunctional inputs and current-controlled outputs ensure maximum adaptability. Can be used as a safety controller up to SIL2/PL d when combined with a T ÜV-certified software... [See More]

  • Network Options: CANbus; CANopen; SAE J1939
  • Input: Analog Input; Frequency or Pulse; Resistance
  • Maximum Channels: 24
  • Output: Frequency or Pulse; Digital
PLCs - Programmable Logic Controllers -- 8066761 [TM241CEC24T from Schneider Electric]
from RS Components, Ltd.

Schneider Electric TM241CEC24T PLC CPU [See More]

  • Network Options: CANbus; Canopen
  • Outputs: 10
  • Inputs: 14
  • Input: Discrete
Programmable controller for mobile machines -- CR720S
from ifm efector inc.

powerful 32 bit triple core controllers with large application memory. Certified as safety controller with CANopen Safety support. Scalable inputs and outputs for standard and safety applications. High-performance CAN and Ethernet interfaces for various communication tasks. Freely programmable to... [See More]

  • Network Options: Ethernet; CANbus
  • Input: Analog Input; Frequency or Pulse; Resistance
  • Maximum Channels: 98
  • Output: Analog Output; Frequency or Pulse; Digital
PLCs - Programmable Logic Controllers -- 8850894
from RS Components, Ltd.

BARTH 0660-0650 PLC I/O Module [See More]

  • Network Options: CANbus; Can
  • Outputs: 9
  • Inputs: 10
  • Input: Analog Input; Analogue, digital
PLCs - Programmable Logic Controllers -- 8850897
from RS Components, Ltd.

BARTH 0850-0650 PLC I/O Module [See More]

  • Network Options: CANbus; Can
  • Outputs: 9
  • Inputs: 10
  • Input: Analog Input; Analogue, digital
Industrial PLC -- GCAN
from Shenyang Vhandy Technology Co., Ltd.

GCAN-PLC series. GCAN-PLC-400: 1*CAN+1*Ethernet+1*RS232 (or RS485). CPU frequency: 168M. Program storage: 16M. Data storage: 512K. GCAN-PLC-510: 1*CAN+1*Ethernet+1*RS232 (or RS485). CPU frequency: 400M. Program storage: 32M. Data storage: 16M. GCAN-PLC-511: 2*CAN+1*Ethernet+1*RS232+1*RS485. CPU... [See More]

  • Network Options: Ethernet; CANbus; CAN, Ethernet, RS232/485, Follow ISO 11898, support CANopen/Modbus RTU/Modsbus TCP, can be used as master or slave station
  • Outputs: 64
  • Inputs: 64
  • Computer Interface Options: CAN, Ethernet, RS232/485, Follow ISO 11898, support CANopen/Modbus RTU/Modsbus TCP, can be used as master or slave station
Controller starter set for mobile machines -- EC2122
from ifm electronic gmbh

Set for familiarising yourself with mobile controllers and displays. With powerful and easily accessible CAN and Ethernet interface. With I/O simulator box for easy setting of inputs and outputs. Can be used immediately thanks to pre-assembly. article can only be ordered once per customer [See More]

  • Network Options: Ethernet; CANbus
  • Computer Interface Options: CAN; Ethernet
  • Programming Options: Front Panel
  • Power: 12~24 DC
Controller -- ESX
from STW Technic

Designed for harsh environments, freely programmable [See More]

  • Network Options: CANbus
  • Inputs: 24
  • Total Points: 36
  • Outputs: 12
Mini PLC -- PLC
from Shenyang Vhandy Technology Co., Ltd.

GCAN-PLC series. GCAN-PLC-400: 1*CAN+1*Ethernet+1*RS232 (or RS485). CPU frequency: 168M. Program storage: 16M. Data storage: 512K. GCAN-PLC-510: 1*CAN+1*Ethernet+1*RS232 (or RS485). CPU frequency: 400M. Program storage: 32M. Data storage: 16M. GCAN-PLC-511: 2*CAN+1*Ethernet+1*RS232+1*RS485. CPU... [See More]

  • Network Options: Ethernet; CANbus; CAN, Ethernet, RS232/485, Follow ISO 11898, support CANopen/Modbus RTU/Modsbus TCP, can be used as master or slave station
  • Outputs: 64
  • Inputs: 64
  • Computer Interface Options: CAN, Ethernet, RS232/485, Follow ISO 11898, support CANopen/Modbus RTU/Modsbus TCP, can be used as master or slave station
programmable controller for mobile machines -- CR0020
from ifm electronic gmbh

For complex control functions in vehicles and mobile machines. With many multifunctional configurable input and output channels. High-performance CAN interfaces for various communication tasks. Programmable to IEC 61131-3 with CODESYS. E1 type approval by the Kraftfahrt-Bundesamt (German Federal... [See More]

  • Network Options: CANbus
  • Input: Analog Input; Frequency or Pulse; Digital
  • Maximum Channels: 40
  • Output: Analog Output; Frequency or Pulse; Digital
Modular PLC -- GCAN-PLC-510
from Shenyang Vhandy Technology Co., Ltd.

GCAN-PLC series. GCAN-PLC-400: 1*CAN+1*Ethernet+1*RS232 (or RS485). CPU frequency: 168M. Program storage: 16M. Data storage: 512K. GCAN-PLC-510: 1*CAN+1*Ethernet+1*RS232 (or RS485). CPU frequency: 400M. Program storage: 32M. Data storage: 16M. GCAN-PLC-511: 2*CAN+1*Ethernet+1*RS232+1*RS485. CPU... [See More]

  • Network Options: Ethernet; CANbus; CAN, Ethernet, RS232/485, Follow ISO 11898, support CANopen/Modbus RTU/Modsbus TCP, can be used as master or slave station
  • Outputs: 64
  • Inputs: 64
  • Computer Interface Options: CAN, Ethernet, RS232/485, Follow ISO 11898, support CANopen/Modbus RTU/Modsbus TCP, can be used as master or slave station
programmable controller for mobile machines -- CR0303
from ifm electronic gmbh

For complex control functions in vehicles and mobile machines. With many multifunctional configurable input and output channels. High-performance CAN interfaces for various communication tasks. For use in driver's cabin and control cabinet. Freely programmable to IEC 61131-3 with CODESYS 2.3 [See More]

  • Network Options: CANbus
  • Input: Analog Input; Frequency or Pulse; Digital
  • Maximum Channels: 42
  • Output: Analog Output; Frequency or Pulse; Digital
PLC -- GCAN-PLC-400/510/511
from Shenyang Vhandy Technology Co., Ltd.

GCAN-PLC series. GCAN-PLC-400: 1*CAN+1*Ethernet+1*RS232 (or RS485). CPU frequency: 168M. Program storage: 16M. Data storage: 512K. GCAN-PLC-510: 1*CAN+1*Ethernet+1*RS232 (or RS485). CPU frequency: 400M. Program storage: 32M. Data storage: 16M. GCAN-PLC-511: 2*CAN+1*Ethernet+1*RS232+1*RS485. CPU... [See More]

  • Network Options: Ethernet; CANbus; CAN, Ethernet, RS232/485, Follow ISO 11898, support CANopen/Modbus RTU/Modsbus TCP, can be used as master or slave station
  • Outputs: 64
  • Inputs: 64
  • Computer Interface Options: CAN, Ethernet, RS232/485, Follow ISO 11898, support CANopen/Modbus RTU/Modsbus TCP, can be used as master or slave station
programmable controller for mobile machines -- CR0401
from ifm electronic gmbh

For simple control functions in vehicles and mobile machines. With many multifunctional configurable input and output channels. High-performance CAN interfaces for various communication tasks. For use in driver's cabin and control cabinet. Freely programmable to IEC 61131-3 with CODESYS 2.3 [See More]

  • Network Options: CANbus
  • Input: Analog Input; Frequency or Pulse; Resistance
  • Maximum Channels: 20
  • Output: Analog Output; Frequency or Pulse; Digital
PLC Automation -- GCAN-PLC
from Shenyang Vhandy Technology Co., Ltd.

GCAN-PLC series. GCAN-PLC-400: 1*CAN+1*Ethernet+1*RS232 (or RS485). CPU frequency: 168M. Program storage: 16M. Data storage: 512K. GCAN-PLC-510: 1*CAN+1*Ethernet+1*RS232 (or RS485). CPU frequency: 400M. Program storage: 32M. Data storage: 16M. GCAN-PLC-511: 2*CAN+1*Ethernet+1*RS232+1*RS485. CPU... [See More]

  • Network Options: Ethernet; CANbus; CAN, Ethernet, RS232/485, Follow ISO 11898, support CANopen/Modbus RTU/Modsbus TCP, can be used as master or slave station
  • Outputs: 64
  • Inputs: 64
  • Computer Interface Options: CAN, Ethernet, RS232/485, Follow ISO 11898, support CANopen/Modbus RTU/Modsbus TCP, can be used as master or slave station
programmable controller for mobile machines -- CR0411
from ifm electronic gmbh

For simple control functions in vehicles and mobile machines. With many multifunctional configurable input and output channels. High-performance CAN interfaces for various communication tasks. For use in driver's cabin and control cabinet. Freely programmable to IEC 61131-3 with CODESYS 2.3 [See More]

  • Network Options: CANbus
  • Input: Analog Input; Frequency or Pulse; Resistance
  • Maximum Channels: 16
  • Output: Analog Output; Frequency or Pulse; Digital
PLC Manufacturer -- GCAN-PLC-511
from Shenyang Vhandy Technology Co., Ltd.

GCAN-PLC series. GCAN-PLC-400: 1*CAN+1*Ethernet+1*RS232 (or RS485). CPU frequency: 168M. Program storage: 16M. Data storage: 512K. GCAN-PLC-510: 1*CAN+1*Ethernet+1*RS232 (or RS485). CPU frequency: 400M. Program storage: 32M. Data storage: 16M. GCAN-PLC-511: 2*CAN+1*Ethernet+1*RS232+1*RS485. CPU... [See More]

  • Network Options: Ethernet; CANbus; CAN, Ethernet, RS232/485, Follow ISO 11898, support CANopen/Modbus RTU/Modsbus TCP, can be used as master or slave station
  • Outputs: 64
  • Inputs: 64
  • Computer Interface Options: CAN, Ethernet, RS232/485, Follow ISO 11898, support CANopen/Modbus RTU/Modsbus TCP, can be used as master or slave station
programmable controller for mobile machines -- CR2532
from ifm electronic gmbh

For complex control functions in vehicles and mobile machines. With many multifunctional configurable input and output channels. High-performance CAN interfaces for various communication tasks. High protection rating for the requirements of mobile machines. Programmable to IEC 61131-3 with CODESYS [See More]

  • Network Options: CANbus
  • Input: Analog Input; Frequency or Pulse; Resistance
  • Maximum Channels: 64
  • Output: Analog Output; Frequency or Pulse; Digital
programmable controller for mobile machines -- CR413S
from ifm electronic gmbh

Freely programmable to IEC 61131-3 with CODESYS 3.5. High-performance CAN interface for various communication tasks. Multifunctional inputs and current-controlled outputs ensure maximum adaptability. Can be used as a safety controller up to SIL2/PL d when combined with a T ÜV-certified software... [See More]

  • Network Options: Ethernet; CANbus; CANopen; SAE J1939
  • Input: Analog Input; Frequency or Pulse; Resistance
  • Maximum Channels: 32
  • Output: Frequency or Pulse; Digital