DC Current Current Sensors
from DigiKey
DC CURRENT TRANSDUCER [See More]
- Current Type: DC Current
from Knick Interface LLC
High-Voltage Isolation Amplifier. Type P2: pluggable screw clamp terminals. Input: selectable calibrated preset ranges. 30 mV...100 V unipolar/bipolar. Offset (zero point) adjustable +/- 5%. Output: 10 V , 20 mA , 4...20 mA selectable. Power supply: 20...230 V AC/DC [See More]
- Current Type: DC Current
- Electrical Output: Voltage; Outputs an analog current signal; 10 V, 20 mA, 4...20 mA selectable
- Power Requirements: DC Powered
- Features: High Voltage
from RS Components, Ltd.
Current Sensor AC/DC 5V 5-Pin Case CB [See More]
- Current Type: AC Current; DC Current
- Approvals / Certifications: RoHS
- Mounting / Configuration: Through hole
from Infineon Technologies AG
XENSIV ™ - TLE4971-A120N5-E0001 high precision coreless current sensor with analog interface and dual fast over-current detection outputs. The Infineon XENSIV TLE4971-A120N5-E0001 is a new automotive qualified pre-programmed 120A sensor. It serves the unique ±120A measurement rage, the... [See More]
- Current Type: AC Current; DC Current
- Current: 120
- Technology: Hall-Effect
- Voltage: 3.1
from WAGO
Current signal conditioner; Current input signal: 80 ADC; Modbus RTU; Supply voltage: 24 VDC [See More]
- Current Type: DC Current
from Isabellenhutte USA
Compact, shunt-based current sensing for automotive applications, including UPS and energy storage systems, battery applications, and fuel cells. An affordable solution for 12-48V systems that don ’t require galvanic isolation. Minimizes external temperature influences. Measures its own... [See More]
- Current Type: DC Current
- Mounting / Configuration: Bar Bus Mounting
- Technology: Shunt-Based Measurement Method
- Current: 500
from Allegro MicroSystems Inc.
The ACS730 provides high-bandwidth (1MHz), high-accuracy current sensing for AC or DC currents, featuring galvanic isolation and a small footprint for high-frequency applications. * Note: If you have issues logging into this feature you may need to enable 3rd party cookies in your browser settings. [See More]
- Current Type: AC Current; DC Current
- Current: 0.0 to 50
- Technology: Hall-Effect
- Voltage: 5
from Knick Interface LLC
High-voltage transducer for current measurement via shunt resistor. Calibrated range selection via switch. Input: ± 30, 50, 60, 90, 100 mV. Output: 4..20mA, ±20mA, ±10V, ... Basic / reinforced isolation 2000/1000 V with protective hoods (protection against contact) M5 bolts HV... [See More]
- Current Type: DC Current
- Isolation Voltage: 0.0200 to 0.2300
- Voltage: 0.0300 to 0.1000
- Power Requirements: DC Powered
from RS Components, Ltd.
Current Sensor AC/DC 5V 5-Pin Case CB [See More]
- Current Type: AC Current; DC Current
- Approvals / Certifications: RoHS
- Mounting / Configuration: Through hole
from Infineon Technologies AG
XENSIV ™ - TLE4972-AE35D5 magnetic coreless current sensor in a leaded TDSO-16 package. The Infineon TLE4972 provides an analogue sensor signal proportional to the measured current as well as two fast overcurrent detection pins. Due to its differential measurement principle it is robust... [See More]
- Current Type: AC Current; DC Current
- Voltage: 3.1
- Technology: Hall-Effect
- Accuracy: 2
from WAGO
Current signal conditioner; Current input signal: 140 ADC; Modbus RTU; Supply voltage: 24 VDC; Module width: 35 mm [See More]
- Current Type: DC Current
from Isabellenhutte USA
The IVT-S is a high precision current measurement system,designed for DC applications, especially for automotiveapplication. The product is based on a modular design andprovides flexibility for fast adaptations to meet customerrequirements in the automotive and the industrial area. Thecontinuous... [See More]
- Current Type: DC Current
- Mounting / Configuration: Clamp or Bolt On; Bar Bus Mounting
- Technology: Shunt-Based Measurement Method
- Current: 100 to 2500
from Allegro MicroSystems Inc.
The ACS722 provides precise current measurements for AC or DC current, featuring pin-selectable bandwidth (80kHz or 20kHz), galvanic isolation, and a small footprint for space-constrained applications. Operates at 5V. * Note: If you have issues logging into this feature you may need to enable 3rd... [See More]
- Current Type: AC Current; DC Current
- Current: 0.0 to 50
- Technology: Hall-Effect
- Voltage: 3.3
from Knick Interface LLC
High-Voltage Amplifier VariTrans. Calibrated range selection via switch. Input: ± 60 / 90 / 150 / 300 / 500 mV / 10V. Output: ± 10 V / ± 20 mA / 4 ... 20 mA. Working voltage (basic isolation): 2.2 kV AC/DC. Test voltage: 10 kV AC. Power supply: 20 ... 253 V AC/DC [See More]
- Current Type: DC Current
- Electrical Output: Voltage; Outputs an analog current signal; ± 10 V / ± 20 mA / 4 ... 20 mA
- Power Requirements: DC Powered
- Features: High Voltage
from RS Components, Ltd.
Current Sensor AC/DC 5V 5-Pin Case CB [See More]
- Current Type: AC Current; DC Current
- Approvals / Certifications: RoHS
- Mounting / Configuration: Through hole
from Infineon Technologies AG
XENSIV ™ - TLE4972-AE35S5 magnetic coreless current sensor in a leadless VSON-6 package. The Infineon TLE4972 –AE35S5 is a high precision current sensor based on Hall technology. Due to its differential measurement principle it is robust against stray fields and suited for current... [See More]
- Current Type: AC Current; DC Current
- Voltage: 3.1
- Technology: Hall-Effect
- Accuracy: 2
from Isabellenhutte USA
Shunt-based DC energy reference meter. for power classes up to 500 kW. A smart solution for demanding applications such as public EV DC fast charging, the IEM-DCC-500 supports current ranges up to 500 A and voltage ranges up to 1,000 V. Shunt measurement technology allows for a compact design and an... [See More]
- Current Type: DC Current
- Mounting / Configuration: Bar Bus Mounting
- Technology: Shunt-Based Measurement Method
- Current: 500
from Allegro MicroSystems Inc.
The ACS723 provides precise current measurements for AC or DC current, featuring pin-selectable bandwidth (80kHz or 20kHz), galvanic isolation, and a small footprint for space-constrained applications. Operates at 3.3V. * Note: If you have issues logging into this feature you may need to enable 3rd... [See More]
- Current Type: AC Current; DC Current
- Current: 0.0 to 50
- Technology: Hall-Effect
- Voltage: 5
from Knick Interface LLC
High-Voltage Amplifier VariTrans. Calibrated range selection via switch. Input: ± 1 / 1 ,5 / 2 / 3 / 5 A. Output: ± 10 V / ± 20 mA / 4 ... 20 mA. Working voltage (basic isolation): 2.2 kV AC/DC. Test voltage: 10 kV AC. Power supply: 20 ... 253 V AC/DC [See More]
- Current Type: DC Current
- Electrical Output: Voltage; Outputs an analog current signal; ± 10 V / ± 20 mA / 4 ... 20 mA
- Power Requirements: DC Powered
- Features: High Voltage
from RS Components, Ltd.
Current Sensor AC/DC 5V 5-Pin Case CB [See More]
- Current Type: AC Current; DC Current
- Approvals / Certifications: RoHS
- Mounting / Configuration: Through hole
from Infineon Technologies AG
XENSIV ™ - TLI4971-A025T5-E0001 magnetic coreless current sensor with analog interface and dual fast over-current detection outputs. The Infineon XENSIVTM TLI4971-A025T5-E0001 is a new sensor, pre-programmed to the 25A measurement range. It offers high precision current measurement in... [See More]
- Current Type: AC Current; DC Current
- Current: 25
- Technology: Hall-Effect
- Voltage: 3.1
from Isabellenhutte USA
IAS is a cutting-edge current sensor that uses shunt and TMR (tunnel magneto resistance) current measurement to meet the highest standards of functional safety and availability. Engineered for redundant sensing with configurable overcurrent threshold detection (OCD), this innovative product ensures... [See More]
- Current Type: AC Current; DC Current
- Mounting / Configuration: Bar Bus Mounting
- Technology: MagnetoResistive; Shunt
- Current: 1000 to 2500
from Allegro MicroSystems Inc.
The ACS37800 simplifies power monitoring in AC and DC systems, providing accurate measurements of active, reactive, and apparent power, along with RMS voltage, current, and integrated fault protection. * Note: If you have issues logging into this feature you may need to enable 3rd party cookies in... [See More]
- Current Type: AC Current; DC Current
- Current: 0.0 to 50
- Technology: Hall-Effect
- Voltage: 5
from Knick Interface LLC
High voltage isolator VariTrans. Fixed settings type. Input: ± 5 A. Output: ± 20 mA. Working voltage (basic isolation): 3.6 kV AC/DC. Test voltage: 15 kV AC. Power supply: 20 ... 253 V AC/DC [See More]
- Current Type: DC Current
- Electrical Output: Voltage; Outputs an analog current signal; ± 20 mA
- Power Requirements: DC Powered
- Features: High Voltage
from RS Components, Ltd.
Current Sensor AC/DC 5V 8-Pin SOIC N [See More]
- Current Type: AC Current; DC Current
- Approvals / Certifications: RoHS
- Mounting / Configuration: Surface mount
from Isabellenhutte USA
The IVT 3 Base is a compact high precision current measurement device, which is built on a platform concept where functional components can be added to adapt to many different use cases. The Pro version supports insulation resistance monitoring and 3 or 6 voltage measurement channels. The IVT 3 Base... [See More]
- Current Type: DC Current
- Mounting / Configuration: Clamp or Bolt On; Bar Bus Mounting
- Technology: Shunt-Based Measurement Method
- Current: 1000 to 4000
from Knick Interface LLC
Universal Amplifier. With pluggable screw clamp terminals. Input: calibrated ranges selectable via DIP switch: ( ±)30,45,50,60,75,90,100,150,300,1000 mV. Output: selectable via DIP switch: ( ±) 10 V, ( ±)20 mA; 4...20 mA (active, passive). Power supply: 24 V DC; 100 … 230 V AC. [See More]
- Current Type: DC Current
- Power Requirements: DC Powered
- Voltage: 24
- Electrical Output: Voltage; Outputs an analog current signal; selectable via DIP switch:
from RS Components, Ltd.
Current Sensor AC/DC 5V 8-Pin SOIC N [See More]
- Current Type: AC Current; DC Current
- Approvals / Certifications: RoHS
- Mounting / Configuration: Surface mount
from RS Components, Ltd.
Current Sensor AC/DC 5V 8-Pin SOIC N [See More]
- Current Type: AC Current; DC Current
- Approvals / Certifications: RoHS
- Mounting / Configuration: Surface mount
from RS Components, Ltd.
Current Sensor AC/DC 3.3V 8-Pin SOIC N [See More]
- Current Type: AC Current; DC Current
- Approvals / Certifications: RoHS
- Mounting / Configuration: Surface mount
from RS Components, Ltd.
Current Sensor AC/DC 5V 8-Pin SOIC N [See More]
- Current Type: AC Current; DC Current
- Approvals / Certifications: RoHS
- Mounting / Configuration: Surface mount
from RS Components, Ltd.
Current Sensor AC/DC 3.3V 8-Pin SOIC N [See More]
- Current Type: AC Current; DC Current
- Approvals / Certifications: RoHS
- Mounting / Configuration: Surface mount
from RS Components, Ltd.
Single-Phase, Dual-Mode(AC/DC) Power-Mon [See More]
- Current Type: AC Current; DC Current
- Approvals / Certifications: RoHS
- Mounting / Configuration: Surface mount
- Operating Temperature: -40
from Eaton Corporation - Sensors
The CurrentWatch EAC Series from Eaton ’s electrical business combines a current transformer and signal conditioner into a single package. The EAC Series has jumper-selected current input ranges and industry standard outputs: 4 – 20 mA, 0 – 5V DC or 0 – 10V DC. This family of... [See More]
- Current Type: DC Current
- Mounting / Configuration: Panel Mount
- Loop Type: Open Loop
- Current: 10 to 50
from American Aerospace Controls, Inc.
Clamp-on; output 0 to ±5V; accuracy 1%FS; power ±15Vdc; response 200m-sec; temperature -25 ° to +75 °C; aperture 1+1/2 inch dia; plastic case; barrier screw or connector terminations [See More]
- Current Type: DC Current
- Mounting / Configuration: Clamp or Bolt On
- Technology: Hall-Effect (optional feature)
- Current: -2500 to 2500
from LEM USA, Inc.
LEM products fall broadly into multiple areas of application and are used within general industry, automotive industry, for railway and trackside applications, energy measurement relating to railway on-board applications, energy & automation, battery monitoring, and in Wi-LEM - wireless... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Time Mark Corporation
The Model 279 DC Current Monitor is a single set-point DC current monitor. It can sense either 1-10 Amps DC (24VAC or 120VAC) or 0.1-1 Amps DC (120VAC). The units have an input frequency of 50/60 Hz. The standard version, the 279B, has a screwdriver adjustable trip and hysteresis setting on top of... [See More]
- Current Type: DC Current
- Current: 0.0 to 15
- Mounting / Configuration: 8-Pin Socket
- Voltage: 24
from Tamura Corporation of America
The magnetic flux created by the primary current (If) is balanced through a secondary coil using the magnetic probe device to provide a feedback and associated electronic circuitry to drive a compensating current in the secondary coil. The secondary (compensating) current is an exact (instantaneous)... [See More]
- Current Type: AC Current; DC Current
- Technology: Flux Gate
- Loop Type: Closed Loop
- Mounting / Configuration: Printed Circuit Board
from Airotronics
The CS is an over or under current sensing control. Toroidal sensing means no break in the power wiring. The combination of the over current LED, current adjustment, and percentage trip adjustment provides easy and accurate setting. CS can handle loads up to 20 amps with time delays up to 100 secs. [See More]
- Current Type: AC Current; DC Current
- Technology: Inductive
- Loop Type: Open Loop
- Mounting / Configuration: Clamp or Bolt On
from HARTING Inc. of North America
The new current sensors from HARTING have a robust design, making them ideal in harsh conditions for markets such as rail technology and renewal energy. . Rapid, accurate current measurement is required for the precise regulation of power semiconductor systems such as frequency... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Closed Loop
- Mounting / Configuration: Clamp or Bolt On
from Setra Systems
The CTC Series current transducers are ideal for monitoring current in PLCs (Power Line Carrier Communication) and AMR systems or in remote control systems of SCADA software for automation and supervision, security, condition monitoring in protection systems and for the predictive maintenance of... [See More]
- Current Type: DC Current
- Current: 30 to 120
- Mounting / Configuration: Clamp or Bolt On
- Voltage: 24
from Jiangyin Xinghuo Deyue Technology Co., Ltd.
4-20mAdc/Rated [See More]
- Current Type: DC Current
- Mounting / Configuration: Clamp or Bolt On
- Loop Type: Open Loop
- Current: 100 to 200000
from Honeywell Sensing & IoT
CSDA Series digital current sensors provide a logic level output that changes from the approximate Vcc to 0.4 V when the sensed current exceeds the operate point. Each digital sensor operates on ac or dc current; however, the output will turn off at every zero crossing when sensing AC current. [See More]
- Current Type: AC Current; DC Current
- Voltage: 6 to 16
- Mounting / Configuration: Printed Circuit Board
- Response Time: 100
from Ohio Semitronics, Inc.
OSI manufactures current sensors that are closed loop, highly-precise, and designed for AC, DC, pulse, and variable-frequency drives. We invite you to chat live with our application and product specialists to find or create a solution that works best for your application. [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Closed Loop
- Mounting / Configuration: Panel Mount; Printed Circuit Board
from Define Instruments
What it does: Clips around a cable to measure AC current. Outputs a 0-10V DC signal. The ACCS-010 is a self powered AC current sensor with no external supply required. It converts a high current AC signal into an industry standard 0 –10V DC isolated output. The ACCS-010 can be used to monitor... [See More]
- Current Type: AC Current; DC Current
- Response Time: 250000
- Current: 100 to 200
- Accuracy: 1
from Transcat, Inc.
Product Highlights. High-precision sensors to view waveforms or to use with power meters (for AC/DC). Super high precision: ±0.05% rdg. ±0.01% f.s. Excellent characteristics: Conductor position/external magnetic field/magnetization effect. CAT III 1000 V Safety. Convenient voltage output... [See More]
- Current Type: AC Current; DC Current
- Current: 500
from MultiDimension Technology Co., Ltd.
Description. TMR7304-B is a closed loop current sensor for accurate measurement of DC, AC, pulsed current and arbitrary waveform current with galvanic isolation between primary and secondary circuits. TMR7304-B. Features and Benefits. High accuracy Excellent linearity. Low temperature coefficient... [See More]
- Current Type: AC Current; DC Current
- Current: 6 to 50
- Loop Type: Closed Loop
- Voltage: 5
from Hoyt Electrical Instrument Works, Inc.
The M100-DA transducers isolate the DC Input signal from the DC Output signal, which is directly proportional to the input signal. A wide range of D.C. Current and Voltage outputs ar offered. Typically these isolators can be used to prevent earth loops, which occur when a measuring source, that is... [See More]
- Current Type: DC Current
- Mounting / Configuration: DIN Rail
- Loop Type: Closed Loop
- Voltage: 115 to 400
from Eaton Corporation - Sensors
The CurrentWatch EACR Series current sensor family from Eaton ’s electrical business combines a current sensor and a “True RMS ” signal conditioner into a single package. The EACR Series provides True RMS output on distorted waveforms found on VFD or SCR outputs, and on linear... [See More]
- Current Type: DC Current
- Mounting / Configuration: Panel Mount
- Loop Type: Open Loop
- Current: 2 to 5
from American Aerospace Controls, Inc.
MIL grade; output 0 to ±5V; accuracy 1%FS; power ±15Vdc; temperature -55 ° to +85 °C; aperture 3/8 inch dia; response 50m-sec; chassis mount; solder, connector or barrier terminations [See More]
- Current Type: DC Current
- Mounting / Configuration: Panel Mount
- Technology: Hall-Effect (optional feature)
- Current: -5 to 5
from Tamura Corporation of America
• Excellent accuracy. • Very good linearity. • Low temperature drift. • Wide frequency bandwidth. • No insertion loss. • High Immunity To External Interference. • Optimised response time. • Current overload capability [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Jiangyin Xinghuo Deyue Technology Co., Ltd.
Measured current range: ≤ ±2000A;. Output form: 4-20mAdc(three-wire)/ ±4Vdc;. Load: ≤500(current type)/ ≥100K(voltagetype);. Power supply voltage: 12V-24Vdc;. Power consumption current: <40mAdc;. Accuracy(Linearity): ≤1%;. Response time: ≤50ns( ±4Vdc)/... [See More]
- Current Type: DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Clamp or Bolt On
from Honeywell Sensing & IoT
CSDA Series digital current sensors provide a logic level output that changes from the approximate Vcc to 0.4 V when the sensed current exceeds the operate point. Each digital sensor operates on ac or dc current; however, the output will turn off at every zero crossing when sensing AC current. [See More]
- Current Type: AC Current; DC Current
- Voltage: 6 to 16
- Mounting / Configuration: Printed Circuit Board
- Response Time: 100
from Ohio Semitronics, Inc.
OSI provides precision Flux-Gate AC/DC current transducers with accuracies up to 0.01% F.S. Units operate bidirectionally and provide an output that is a scaled replica of the unit. We invite you to chat live with our application and product specialists to find or create a solution that works best... [See More]
- Current Type: DC Current
- Current: 0.0 to 600
- Mounting / Configuration: Panel Mount
- Response Time: 1
from Define Instruments
What it does: Clips around a cable to measure HIGH AC current. Outputs a 4-20mA signal. The ACCS-420 is a loop powered AC current sensor that converts and isolates a high current AC signal into an industry standard 4 –20mA DC signal. It can be used to monitor AC current loads in switchboards,... [See More]
- Current Type: AC Current; DC Current
- Voltage: 15 to 36
- Current: 100 to 200
- Response Time: 250000
from Transcat, Inc.
Product Highlights. Hioki clamp on meters are best-in-class measuring devices incorporating Hioki ’s expertise in current sensing technology. The CT7731 is a 100 A AC/DC Current Sensor that pairs with the detachable Display Unit CM7290 for convenient field testing, while delivering an extended... [See More]
- Current Type: AC Current; DC Current
- Current: 100
from MultiDimension Technology Co., Ltd.
Description. TMR7304-C is a closed loop current sensor for accurate measurement of DC, AC, pulsed current and arbitrary waveform current with galvanic isolation between primary and secondary circuits. TMR7304-C. Features and Benefits. High accuracy Excellent linearity. Low temperature coefficient... [See More]
- Current Type: AC Current; DC Current
- Current: 6 to 50
- Loop Type: Closed Loop
- Voltage: 5
from Hoyt Electrical Instrument Works, Inc.
Use in conjunction with earth leakage relays (type A). Designed to detect leakage current and transmit a. Proportional signal to an earth leakage relay. Surface mounting with 4 fixing slots (not BZCT210). Slim design only 20mm width [See More]
- Current Type: AC Current; DC Current
- Mounting / Configuration: Through Hole (Toroid)
- Technology: Inductive
- Current: 0.0300 to 100000
from Eaton Corporation - Sensors
The CurrentWatch EDC Series from Eaton ’s electrical business combines a hall effect sensor and signal conditioner into a single package for use in DC current applications up to 300A. The EDC Series has jumper-selected current input ranges and industry standard outputs: 4 – 20 mA, 0... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Panel Mount
from American Aerospace Controls, Inc.
Clamp-on; output 0 to ±5V; accuracy 1%FS; power ±15Vdc; response 200m-sec; temperature -25 ° to +75 °C; aperture 1+1/2 inch dia; metal case; barrier screw or connector terminations [See More]
- Current Type: DC Current
- Mounting / Configuration: Clamp or Bolt On
- Technology: Hall-Effect (optional feature)
- Current: -2500 to 2500
from Tamura Corporation of America
• Excellent accuracy. • Very good linearity. • Low temperature drift. • Wide frequency bandwidth. • No insertion loss. • High Immunity To External Interference. • Optimised response time. • Current overload capability [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Panel Mount
from Honeywell Sensing & IoT
CSDA Series digital current sensors provide a logic level output that changes from the approximate Vcc to 0.4 V when the sensed current exceeds the operate point. Each digital sensor operates on ac or dc current; however, the output will turn off at every zero crossing when sensing AC current. [See More]
- Current Type: AC Current; DC Current
- Voltage: 6 to 16
- Mounting / Configuration: Printed Circuit Board
- Response Time: 100
from Ohio Semitronics, Inc.
OSI manufactures current sensors that are open loop, highly-precise, and designed for AC, DC, pulse, and variable-frequency drives. We invite you to chat live with our application and product specialists to find or create a solution that works best for your application. [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Panel Mount; DIN Rail-Mount
from Transcat, Inc.
Product Highlights. Hioki clamp on meters are best-in-class measuring devices incorporating Hioki ’s expertise in current sensing technology. The CT7736 is a 600 A AC/DC Current Sensor that pairs with the detachable Display Unit CM7290 for convenient field testing, while delivering an extended... [See More]
- Current Type: AC Current; DC Current
- Current: 600
from MultiDimension Technology Co., Ltd.
Description. TMR7304-D is a closed loop current sensor for accurate measurement of DC, AC, pulsed current and arbitrary waveform current with galvanic isolation between primary and secondary circuits. TMR7304-D. Features and Benefits. High accuracy Excellent linearity. Low temperature coefficient... [See More]
- Current Type: AC Current; DC Current
- Current: 6 to 50
- Loop Type: Closed Loop
- Voltage: 5
from Hoyt Electrical Instrument Works, Inc.
Used in conjunction with earth leakage relays (type A). Designed to detect leakage current and transmit a. Proportional signal to an earth leakage relay. Suitable for installations that use busbars [See More]
- Current Type: AC Current; DC Current
- Mounting / Configuration: Through Hole (Toroid)
- Technology: Inductive
- Power Requirements: Self-powered
from Eaton Corporation - Sensors
The CurrentWatch EPRM Series from Eaton ’s electrical business is a family of DIN-rail compatible, split-core current sensors. Product features include a large aperture, switch-selectable inputs and outputs and isolation between primary and secondary circuits. A patented technology eliminates... [See More]
- Current Type: DC Current
- Mounting / Configuration: Panel Mount; DIN Rail
- Loop Type: Open Loop
- Current: 10 to 50
from American Aerospace Controls, Inc.
MIL grade: output 0 to ±5V; accuracy 0.25%FS; power +24 to 32Vdc; temperature -55 ° to +85 °C; aperture 3/8 inch dia; response 5m-sec; chassis mount; solder, connector or barrier terminations [See More]
- Current Type: DC Current
- Mounting / Configuration: Panel Mount
- Technology: Hall-Effect (optional feature)
- Current: -25 to 25
from Tamura Corporation of America
• Excellent accuracy. • Very good linearity. • Low temperature drift. • Wide frequency bandwidth. • No insertion loss. • High Immunity To External Interference. • Optimised response time. • Current overload capability [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Panel Mount
from Honeywell Sensing & IoT
CSL Series inductive analog current sensors incorporate the SS490 Series linear Hall-effect sensor ICs. The sensing element is encapsulated in a printed circuit board-mountable plastic package. The combination of sensor and flux collector comprises the current sensor assembly. These sensors are... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Transcat, Inc.
Product Highlights. Hioki clamp on meters are best-in-class measuring devices incorporating Hioki ’s expertise in current sensing technology. The CT7742 is a 2000 A AC/DC Current Sensor that pairs with the detachable Display Unit CM7290 for convenient field testing, while delivering an... [See More]
- Current Type: AC Current; DC Current
- Frequency Range: 0.0 to 5000
from MultiDimension Technology Co., Ltd.
Description. TMR7304-E is a closed loop current sensor for accurate measurement of DC, AC, pulsed current and arbitrary waveform current with galvanic isolation between primary and secondary circuits. TMR7304-E. Features and Benefits. High accuracy Excellent linearity. Low temperature coefficient... [See More]
- Current Type: AC Current; DC Current
- Current: 75
- Loop Type: Closed Loop
- Voltage: 5
from American Aerospace Controls, Inc.
Mil grade current sensor; output 0 to ±5V; accuracy 1%FS (over temperature); power +10Vdc to +34Vdc; frequency DC-350KHz; response 1micro-sec; temperature –40 ° to +85 °C; aperture 3/4 inch dia; connector or barrier terminations WT 6 oz. (170 grams) [See More]
- Current Type: DC Current
- Mounting / Configuration: Panel Mount
- Technology: Hall-Effect (optional feature)
- Current: 0.0 to 400
from Tamura Corporation of America
• Excellent accuracy. • Very good linearity. • Low temperature drift. • Wide frequency bandwidth. • No insertion loss. • High Immunity To External Interference. • Optimised response time. • Current overload capability [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Panel Mount
from Honeywell Sensing & IoT
CSL Series inductive analog current sensors incorporate the SS490 Series linear Hall-effect sensor ICs. The sensing element is encapsulated in a printed circuit board-mountable plastic package. The combination of sensor and flux collector comprises the current sensor assembly. These sensors are... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Transcat, Inc.
Product Highlights. CAT III 1000 V, 200A AC/DC rated current, DC to 500kHz response, core dia. 24 mm (0.94 in), cord length 3 m (9.84 ft) [See More]
- Current Type: AC Current; DC Current
- Current: 200
from MultiDimension Technology Co., Ltd.
Description. TMR7308-B is a closed loop current sensor for accurate measurement of DC, AC, pulsed current and arbitrary waveform current with galvanic isolation between primary and secondary circuits. TMR7308-B. Features and Benefits. Low temperature coefficient Galvanic isolation. High immunity to... [See More]
- Current Type: AC Current; DC Current
- Current: 50 to 100
- Loop Type: Closed Loop
- Voltage: 15
from American Aerospace Controls, Inc.
MIL grade; output 0 to ±5V; accuracy 0.5%FS; power ±15Vdc; frequency DC-100KHz; response 1m-sec; temperature -55 ° to +85 °C; aperture 1+3/8 inch dia; metal case; barrier or connector terminations [See More]
- Current Type: AC Current; DC Current
- Mounting / Configuration: Panel Mount
- Technology: Hall-Effect (optional feature)
- Current: -1000 to 1000
from Tamura Corporation of America
• Excellent accuracy. • Very good linearity. • Low temperature drift. • Wide frequency bandwidth. • No insertion loss. • High Immunity To External Interference. • Optimised response time. • Current overload capability [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Honeywell Sensing & IoT
CSL Series in-circuit analog current sensors incorporate the SS490 Series linear Hall-effect sensor ICs. The sensing element is encapsulated in a printed circuit board-mountable plastic package. The combination of sensor and flux collector comprises the current sensor assembly. These sensors are... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Transcat, Inc.
Product Highlights. CAT III 1000 V, 500A AC/DC rated current, DC to 100kHz response, core dia. 36 mm (1.42 in), cord length 3 m (9.84 ft) [See More]
- Current Type: AC Current; DC Current
- Current: 500
from MultiDimension Technology Co., Ltd.
Description. TMR7309-B is a closed loop current sensor for accurate measurement of DC, AC, pulsed current and arbitrary waveform current with galvanic isolation between primary and secondary circuits. TMR7309-B. Features and Benefits. Low temperature coefficient Galvanic isolation. High immunity to... [See More]
- Current Type: AC Current; DC Current
- Current: 125
- Loop Type: Closed Loop
- Voltage: 15
from American Aerospace Controls, Inc.
MIL grade: output 0 to ±5V; accuracy 0.5%FS; power ±15Vdc; frequency DC-20KHz; temperature -55 ° to +85 °C; aperture 1+3/8 inch dia; metal case; barrier screw or connector terminations [See More]
- Current Type: AC Current; DC Current
- Mounting / Configuration: Panel Mount
- Technology: Hall-Effect (optional feature)
- Current: -2000 to 2000
from Tamura Corporation of America
• Excellent accuracy. • Very good linearity. • Low temperature drift. • Wide frequency bandwidth. • No insertion loss. • High Immunity To External Interference. • Optimised response time. • Current overload capability [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Honeywell Sensing & IoT
CSL Series in-circuit analog current sensors incorporate the SS490 Series linear Hall-effect sensor ICs. The sensing element is encapsulated in a printed circuit board-mountable plastic package. The combination of sensor and flux collector comprises the current sensor assembly. These sensors are... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Transcat, Inc.
Product Highlights. CAT III 1000 V, 50A AC/DC rated current, DC to 1MHz response, core dia. 24 mm (0.94 in), cord length 3 m (9.84 ft) [See More]
- Current Type: AC Current; DC Current
- Current: 50
from MultiDimension Technology Co., Ltd.
Description. TMR7559-B is a close loop current sensor for accurate measurement of DC, AC, pulsed current and arbitrary waveform current with galvanic isolation between primary and secondary circuits. TMR7559-B. Features and Benefits. High accuracy Excellent linearity. Low temperature coefficient... [See More]
- Current Type: AC Current; DC Current
- Current: 100 to 250
- Loop Type: Closed Loop
- Voltage: 5
from American Aerospace Controls, Inc.
Industrial grade; output 0 to ±5V; accuracy 0.5%FS; power ±15Vdc; frequency DC-100KHz; response 1m-sec; temperature -20 ° to +70 °C; aperture 1+1/2 inch dia; plastic case; barrier screw terminations [See More]
- Current Type: AC Current; DC Current
- Mounting / Configuration: Panel Mount
- Technology: Hall-Effect (optional feature)
- Current: -600 to 600
from Tamura Corporation of America
• Excellent accuracy. • Very good linearity. • Low temperature drift. • Wide frequency bandwidth. • No insertion loss. • High Immunity To External Interference. • Optimised response time. • Current overload capability [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Honeywell Sensing & IoT
CSL Series in-circuit analog current sensors incorporate the SS490 Series linear Hall-effect sensor ICs. The sensing element is encapsulated in a printed circuit board-mountable plastic package. The combination of sensor and flux collector comprises the current sensor assembly. These sensors are... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Transcat, Inc.
Product Highlights. Power supply and signal output for Current Sensor CT7600 and CT7700 series. Simultaneous dual display of the measured values, frequency, and output rate. Four output formats to output data to loggers or other devices (via Display Unit). Supports AC adapter, AA alkaline batteries,... [See More]
- Current Type: AC Current; DC Current
from MultiDimension Technology Co., Ltd.
Description. TMR7559-C is a close loop current sensor for accurate measurement of DC, AC, pulsed current and arbitrary waveform current with galvanic isolation between primary and secondary circuits. TMR7559-C. Features and Benefits. High accuracy Excellent linearity. Low temperature coefficient... [See More]
- Current Type: AC Current; DC Current
- Current: 100 to 250
- Loop Type: Closed Loop
- Voltage: 5
from American Aerospace Controls, Inc.
Industrial grade; output 0 to ±5V; accuracy 0.5%FS; power ±15Vdc; frequency DC-20KHz; temperature -20 ° to +70 °C; aperture 1+1/2 inch dia; plastic case; barrier screw terminations [See More]
- Current Type: AC Current; DC Current
- Mounting / Configuration: Panel Mount
- Technology: Hall-Effect (optional feature)
- Current: -2000 to 2000
from Tamura Corporation of America
• Excellent accuracy. • Very good linearity. • Low temperature drift. • Wide frequency bandwidth. • No insertion loss. • High Immunity To External Interference. • Optimised response time. • Current overload capability [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Honeywell Sensing & IoT
CSL Series in-circuit analog current sensors incorporate the SS490 Series linear Hall-effect sensor ICs. The sensing element is encapsulated in a printed circuit board-mountable plastic package. The combination of sensor and flux collector comprises the current sensor assembly. These sensors are... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Transcat, Inc.
Product Highlights. Super high precision, ±0.06% amplitude accuracy, ±0.2 degree phase accuracy. Wide-bandwidth DC to 1 MHz (CT6862) excellent frequency characteristics. Applications in the fields of electric and hybrid electric vehicles. A wide operating temperature range is fit to the... [See More]
- Current Type: AC Current; DC Current
- Current: 1000
from MultiDimension Technology Co., Ltd.
Description. TMR7102-D is closed loop current sensors for accurate measurement of DC current with galvanic isolation between primary and secondary circuits. TMR7102-D. Features and Benefits. Low temperature coefficient Galvanic isolation. High immunity to external interference High accuracy among... [See More]
- Current Type: DC Current
- Current: 500
- Loop Type: Closed Loop
- Voltage: 13.5
from American Aerospace Controls, Inc.
MIL grade; output 0 to ±5V; accuracy 0.5%FS; power ±15Vdc; frequency DC-100KHz; response 1m-sec; temperature -55 ° to +85 °C; aperture 3/4 inch dia; solder, connector or barrier terminations [See More]
- Current Type: DC Current
- Mounting / Configuration: Panel Mount
- Technology: Hall-Effect (optional feature)
- Current: -350 to 350
from Tamura Corporation of America
• Excellent accuracy. • Very good linearity. • Low temperature drift. • Wide frequency bandwidth. • No insertion loss. • High Immunity To External Interference. • Optimised response time. • Current overload capability [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Honeywell Sensing & IoT
CSLA Series inductive analog current sensors incorporate SS490 Series linear Hall-effect sensor ICs. The sensing element is assembled in a printed circuit board mountable housing. This housing is available in four configurations. Normal mounting is with 0.375 inch 4-40 screw and square nut (not... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Transcat, Inc.
Product Highlights. Achieve a maximum accuracy of ±0.16%, which is equivalent to power meters using a direct cable connection (when used with the POWER ANALYZER 3390). The cable connecting the power source and load can be made thicker and shorter to allow measurement to be performed in nearly... [See More]
- Current Type: AC Current; DC Current
- Current: 200
from MultiDimension Technology Co., Ltd.
Description. TMR7102-E is closed loop current sensors for accurate measurement of DC current with galvanic isolation between primary and secondary circuits. TMR7102-E. Features and Benefits. Low temperature coefficient Galvanic isolation. High immunity to external interference High accuracy among... [See More]
- Current Type: DC Current
- Current: 500
- Loop Type: Closed Loop
- Voltage: 13.5
from American Aerospace Controls, Inc.
Space flight; output 0 to ±5V; accuracy 0.5%FS; power ±15Vdc; frequency DC-100KHz; response 1m-sec; temperature -40 ° to +71 °C; aperture 1/4 inch dia; solder header terminations [See More]
- Current Type: AC Current; DC Current
- Mounting / Configuration: Panel Mount
- Technology: Hall-Effect (optional feature)
- Current: -60 to 60
from Tamura Corporation of America
• Excellent accuracy. • Very good linearity. • Low temperature drift. • Wide frequency bandwidth. • No insertion loss. • High Immunity To External Interference. • Optimised response time. • Current overload capability [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Honeywell Sensing & IoT
CSLA Series inductive analog current sensors incorporate SS490 Series linear Hall-effect sensor ICs. The sensing element is assembled in a printed circuit board mountable housing. This housing is available in four configurations. Normal mounting is with 0.375 inch 4-40 screw and square nut (not... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Transcat, Inc.
Product Highlights. Achieve a maximum accuracy of ±0.16%, which is equivalent to power meters using a direct cable connection (when used with the POWER ANALYZER 3390). The cable connecting the power source and load can be made thicker and shorter to allow measurement to be performed in nearly... [See More]
- Current Type: AC Current; DC Current
- Current: 50
from MultiDimension Technology Co., Ltd.
Description. The TMR7616-C series current sensor IC operate on the principle of electromagnetic induction with high sensitivity, high signal-to-noise ratio tunneling magnetoresistance (TMR) sensors. With an internal conditioning circuit and electrical isolation between the primary and secondary... [See More]
- Current Type: AC Current; DC Current
- Current: 20 to 65
- Technology: Inductive
- Voltage: 3.3 to 5
from American Aerospace Controls, Inc.
Rail transit; output 0 to ±250mA; accuracy 0.5%FS; power +24Vdc; response 1m-sec; temperature -25 ° to +75 °C; aperture 1+1/2 inch dia; plastic case; bus-bar available; barrier screw terminations [See More]
- Current Type: AC Current; DC Current
- Mounting / Configuration: Panel Mount
- Technology: Hall-Effect (optional feature)
- Current: -1000 to 1000
from Tamura Corporation of America
• Excellent accuracy. • Very good linearity. • Low temperature drift. • Wide frequency bandwidth. • No insertion loss. • High Immunity To External Interference. • Optimised response time. • Current overload capability [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Honeywell Sensing & IoT
CSLA Series inductive analog current sensors incorporate SS490 Series linear Hall-effect sensor ICs. The sensing element is assembled in a printed circuit board mountable housing. This housing is available in four configurations. Normal mounting is with 0.375 inch 4-40 screw and square nut (not... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Transcat, Inc.
Product Highlights. Hioki clamp on meters are best-in-class measuring devices incorporating Hioki ’s expertise in current sensing technology. The CT7642 is a 2000 A AC/DC Current Sensor that pairs with the detachable Display Unit CM7290 to capture instantaneous waveforms that can be output to... [See More]
- Current Type: AC Current; DC Current
- Current: 2000
from MultiDimension Technology Co., Ltd.
Description. TMR7302-E is based on the open loop integrated current sensor for measuring DC, AC, pulsed current and arbitrary waveform current with galvanic isolation and its internal temperature compensation circuitry provides excellent performance under different ambient temperature ranges. [See More]
- Current Type: AC Current; DC Current
- Current: 50 to 250
- Loop Type: Open Loop
- Voltage: 3.3 to 5
from American Aerospace Controls, Inc.
MIL grade; output 0 to ±5V; accuracy 1%FS; power +22 to +32Vdc; frequency DC-3.5KHz; response 100m-sec; temperature -40 ° to +65 °C; aperture 1+3/8 inch dia; connector terminations [See More]
- Current Type: DC Current
- Mounting / Configuration: Panel Mount
- Technology: Hall-Effect (optional feature)
- Current: -200 to 200
from Tamura Corporation of America
L18P***S05R Series. Hall Effect Current Sensors. Features: Open Loop type. Printed circuit board mounting. Integrated primary. Unipolar power supply. Busbar version from 40A to 60A. Insulated plastic case according to UL94V0. Regulated offset voltage. Advantages: Excellent accuracy and linearity. [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Honeywell Sensing & IoT
CSLA Series inductive analog current sensors incorporate SS490 Series linear Hall-effect sensor ICs. The sensing element is assembled in a printed circuit board mountable housing. This housing is available in four configurations. Normal mounting is with 0.375 inch 4-40 screw and square nut (not... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Transcat, Inc.
Product Description. Hioki clamp on meters are best-in-class measuring devices incorporating Hioki ’s expertise in current sensing technology. The CT7631 is a 100 A AC/DC Current Sensor that pairs with the detachable Display Unit CM7290 to capture instantaneous waveforms that can be output to... [See More]
- Current Type: AC Current; DC Current
- Current: 100
from MultiDimension Technology Co., Ltd.
Description. TMR7307-C series current sensor is a type of TMR based isolated, open loop current sensor. Benefits the wide bandwidth, it is suitable for measuring DC, AC, pulse and mixed types of current signals. The TMR7307-C series provides multiple current options as 20A, 25A, 32A, 40A, 50A. The... [See More]
- Current Type: AC Current; DC Current
- Current: 20 to 50
- Loop Type: Open Loop
- Voltage: 5
from American Aerospace Controls, Inc.
Bi-directional current transducers, special purpose, wide temperature, fast response, MIL Grade, split yoke, high current, low cost [See More]
- Current Type: DC Current
- Mounting / Configuration: Panel Mount
- Technology: Hall-Effect (optional feature)
- Current: -200 to 200
from Tamura Corporation of America
• Excellent accuracy. • Very good linearity. • Low temperature drift. • Wide frequency bandwidth. • No insertion loss. • High Immunity To External Interference. • Optimised response time. • Current overload capability [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Honeywell Sensing & IoT
CSLA Series inductive analog current sensors incorporate SS490 Series linear Hall-effect sensor ICs. The sensing element is assembled in a printed circuit board mountable housing. This housing is available in four configurations. Normal mounting is with 0.375 inch 4-40 screw and square nut (not... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Transcat, Inc.
Product Highlights. Hioki clamp on meters are best-in-class measuring devices incorporating Hioki ’s expertise in current sensing technology. The CT7636 is a 600 A AC/DC Current Sensor that pairs with the detachable Display Unit CM7290 to capture instantaneous waveforms that can be output to a... [See More]
- Current Type: AC Current; DC Current
- Current: 600
from MultiDimension Technology Co., Ltd.
Description. TMR7401-1000mA leakage current sensor based on magnetic induction principle, incorporates our tunneling magneto resistive (TMR) sensor with high sensitivity and high SNR. With the build-in conditioning circuits for offset voltage, temperature and non-linearity compensation, it provides... [See More]
- Current Type: AC Current; DC Current
- Technology: Inductive; MagnetoResistive
- Loop Type: Open Loop
- Current: 1
from American Aerospace Controls, Inc.
MIL grade; output 0 to ±5V; accuracy 1%FS; power ±15Vdc; temperature -40 ° to +85 °C; aperture 3/4 inch dia; frequency DC to 60Hz; response 1m-sec; solder, connector or barrier terminations [See More]
- Current Type: AC Current; DC Current
- Mounting / Configuration: Panel Mount
- Technology: Hall-Effect (optional feature)
- Current: -1 to 1
from Tamura Corporation of America
L31S***S05 Series. Hall Effect Current Sensors. Features: Open Loop type. Printed circuit board mounting. Unipolar power supply. Industrial temperature range. Sulfur-proof version available (add "S " suffix to part number). Mounting pins. Insulated plastic case according to UL94V0. [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from Honeywell Sensing & IoT
CSLA Series inductive analog current sensors incorporate SS490 Series linear Hall-effect sensor ICs. The sensing element is assembled in a printed circuit board mountable housing. This housing is available in four configurations. Normal mounting is with 0.375 inch 4-40 screw and square nut (not... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from MultiDimension Technology Co., Ltd.
Description. TMR7401-300mA leakage current sensor based on magnetic induction principle, incorporates our tunneling magneto resistive (TMR) sensor with high sensitivity and high SNR. With the build-in conditioning circuits for offset voltage, temperature and non-linearity compensation, it provides... [See More]
- Current Type: AC Current; DC Current
- Technology: Inductive; MagnetoResistive
- Loop Type: Open Loop
- Current: 0.3000
from American Aerospace Controls, Inc.
Space flight; output 0 to ±5V; accuracy 0.5%FS; power ±12Vdc; frequency DC-20KHz; response 1-2m-sec; temperature -55 ° to +100 °C; aperture 3/8 inch dia; metal case; weight 8oz.; solder header terminations [See More]
- Current Type: DC Current
- Mounting / Configuration: Panel Mount
- Technology: Hall-Effect (optional feature)
- Current: -250 to 0.2500
from Tamura Corporation of America
L34S***D15 Series. Hall Effect Current Sensors. Features: Open Loop type. Panel mounting. Bipolar power supply. Large aperture. Insulated plastic case according to UL94V0. Advantage: Excellent accuracy and linearity. Wide nominal current range. Low temperature drift. No insertion loss. High Immunity... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Panel Mount
from Honeywell Sensing & IoT
CSLA Series inductive analog current sensors incorporate SS490 Series linear Hall-effect sensor ICs. The sensing element is assembled in a printed circuit board mountable housing. This housing is available in four configurations. Normal mounting is with 0.375 inch 4-40 screw and square nut (not... [See More]
- Current Type: AC Current; DC Current
- Technology: Hall-Effect
- Loop Type: Open Loop
- Mounting / Configuration: Printed Circuit Board
from MultiDimension Technology Co., Ltd.
Description. TMR7401-600mA leakage current sensor based on magnetic induction principle, incorporates our tunneling magneto resistive (TMR) sensor with high sensitivity and high SNR. With the build-in conditioning circuits for offset voltage, temperature and non-linearity compensation, it provides... [See More]
- Current Type: AC Current; DC Current
- Technology: Inductive; MagnetoResistive
- Loop Type: Open Loop
- Current: 0.6000