Flow Calibration Instruments
from Sierra Instruments, Inc.
CalTrak ™ SL-800 primary standard gas calibration systems offer a standardized accuracy of ±0.15% of reading, superior to all other commercial laboratory standards. The SL-800 is fast, primary, Mercury-free and easy-to-use. The dimensionally-based primary accuracy of the CalTrak... [See More]
- Environmental Properties: Flow
- User Interface: Digital Front Panel; Computer Interface
- Calibrator Style: Portable; Battery Powered
- Digital Interface: Serial Interface
from ABB Measurement & Analytics
The CalMaster2 suite comprises 2 elements (CalMaster IRIS and CheckMaster). CalMaster IRIS (Intelligent Recognition Information System) is used to verify in situ mains and battery-powered flowmeter systems. CheckMaster is a field validation device that checks whether a metering system has been... [See More]
- Environmental Properties: Flow
- DC Current Range: 0.0 to ?
- Calibrator Style: Fixed; Battery Powered
- User Interface: Digital Front Panel
from Advanced Test Concepts, Inc. (ATC, Inc.)
The GAS-CAL © instrument has a built-in pressure standard with a PC-based interface with Venturi Nozzles and the IGFS. The GAS-CAL © gas flow calibrator uses multiple technologies for precision gas flow testing, calibration, and analysis in the field, on the shop floor, or in the lab. [See More]
- Environmental Properties: Flow
- User Interface: Digital Front Panel
- Calibrator Style: Portable
- Display: Digital Readouts
from TSI Incorporated
The Primary Calibrator 4046 has a range of 2.5 to 300 liters per minute (L/min). This small, portable, battery-operated unit is lightweight and easy to use. Volumetric flowrate is displayed continuously so adjustments to pump flow can be made in real-time. This primary calibrator is accurate to +/-... [See More]
- Environmental Properties: Flow
from Flow Technology, Inc.
Flow Technology ’s Microtrak and Omnitrak positive displacement computer –assisted liquid flowmeter calibration systems provide performance, reliability and economical benefits of ownership. Exceptional accuracy and stability are achieved from a precisely honed, chrome –plated... [See More]
- Environmental Properties: Flow
- User Interface: Computer Interface
- Calibrator Style: Fixed
- Operating Temp: 60 to 120
from Tinsley Precision Instruments
Tinsley Flow Meter Calibrators are portable, easy-to-use kits for werification of the accuracy of Differential Pressure instruments, Recorders, Controllers, Transmitters and Indicators [See More]
- Environmental Properties: Flow
- Display: Digital Readouts
- User Interface: Digital Front Panel
from Daniel Measurement and Control Inc.
Exact measurement of liquid flow requires on-site meter calibration with liquid at operating conditions. Pipe provers from Daniel perform that important task, calibrating turbine, positive displacement and Coriolis meters in the field. Daniel pipe provers automatically record flow meter output... [See More]
- Environmental Properties: Flow
- User Interface: Computer Interface
- Calibrator Style: Fixed
- Digital Interface: Serial Interface
from Sensidyne, LP
Sensidyne ’s GILIBRATOR-2 ® System provides the user with a convenient and highly automated way to check almost any commercially available air sampling pumps for proper air flow function before their deployment. The system consists of an electronic GILIBRATOR-2 ® Base, which is used... [See More]
- Environmental Properties: Flow
- User Interface: Computer Interface
- Calibrator Style: Portable
- Digital Interface: Serial Interface
from Hayward Flow Control
PVC and Glass Calibration Cylinders/Columns for Chemical Feed system applications. A timed draw-down of the liquid in the cylinder provides an accurate measurement of the pumps actual output against system pressure. [See More]
- Environmental Properties: Flow
- Calibrator Style: Portable
from HORIBA Instruments, Inc.
The MFT-20 offers a way of checking whether the mass flow controller (MFC) is operating normally by driving and controlling the MFC while monitoring the input and output voltages. In this manner, any abnormalities in the MFC or power supply can be quickly examined before being removed from the... [See More]
- Environmental Properties: Flow
- Calibration Signal: DC Voltage
- Calibrator Style: Handheld
- DC Voltage Range: 7 to 30
from Badger Meter
The Flo-tech Flo-Check ® USB Hydraulic System Analyzer can be used as a stationary or portable tester for both industrial and mobile hydraulic system diagnostics. Portable Tester. Accurate Diagnostics. The Flo-tech Flo-Check ® USB Hydraulic System Analyzer simultaneously measures flow,... [See More]
- Environmental Properties: Flow; Pressure / Vacuum
- Operating Temp: -40 to 185
- Calibrator Style: Handheld; Portable
from Ultra Energy
Digital air flow calibrators are accurate devices designed for the calibration of all types of air samplers and continuous air monitors. Features: Differential pressure flow sensor. Display of flow in CFM, LPM or M3/min. by operator selection. Standard accuracy: ±2.0% Full Scale. Flow rates... [See More]
- Environmental Properties: Flow
- User Interface: Digital Front Panel
- Calibrator Style: Portable; Battery Powered
- Display: Digital Readouts
from Owlstone Inc.
The OVG-4 is a compact, cost effective calibration gas system, which generates high accuracy, NIST traceable calibration gas standards. [See More]
- Environmental Properties: Flow; Gas; Temperature
- User Interface: Digital Front Panel
- Calibrator Style: Fixed; Modular
- Digital Interface: Serial Interface
from Hoffer Flow Controls, Inc.
CRYOGENIC TRANSFER STANDARD FOR FIELD CALIBRATIONS OF BULK TRANPORT SYSTEMS. The dream of a quick, simple, and reliable field calibration system for cryogenic flowmetering systems has become a reality with the introduction of the Hoffer SY-14B Cryogenic Transfer Standard. When suitably documented by... [See More]
- Environmental Properties: Flow
- Calibration Signal: AC Voltage; DC Voltage
- Calibrator Style: Portable
- User Interface: Digital Front Panel