Process Gas Combustion Analyzers

44 Results
ATEX Compliant Gas Analyzer -- AK100 Series
from ABB Measurement & Analytics

The H2 purity and purge gas monitor AK100 provides a complete system for monitoring hydrogen purity during normal operation and purge gas monitoring during commissioning and decommissioning of the generator. [See More]

  • Application: Ambient Air Monitoring; Process Gas
  • Analyzer Technology: Thermal Conductivity
  • Mounting Type: Fixed
  • Number of Gases Monitored: Multi
BTU CalorVal Analyzer -- Model 690
from Control Instruments Corp.

Control Instruments' CalorVal BTU Analyzer is a micro-combustion calorimeter. Because of its unique construction and operating technology, it is the optimum analyzer for directly measuring the total heating value of varying waste gas streams of industrial processes. Continuous & Direct measure... [See More]

  • Application: Process Gas
  • Analyzer Technology: Micro-combustion calorimeter
  • Mounting Type: Fixed
  • Number of Gases Monitored: Multi
Multi-component Analyzer System To Accurately Monitor The Composition Of Exhaust Gases -- ACF5000
from ABB Measurement & Analytics

ABB ’s new ACF5000 is the specialist for emission and process monitoring from the pioneers in FTIR CEMS. It is available in the 4th generation. Since introduction in 1993, ABB has sold more than 2000 units. The standard system design combines the advantages of a FTIR spectrometer, flame... [See More]

  • Application: Continuous Emissions Monitoring; Process Gas
  • Number of Gases Monitored: Multi
  • Mounting Type: Fixed
  • Measurement Type: %Volume; Trace
Infrared Vapor Flamability Analyzer -- SNR610
from Control Instruments Corp.

For flammable gas monitoring in relatively clean, low temperature, low concentration applications. It ’s suitable for single or select solvent ranges and can also be used for mixtures of solvents in processes where normal solvent concentrations are below 25% LFL. Built on proven industrial... [See More]

  • Application: Ambient Air Monitoring; Process Gas
  • Analyzer Technology: Infrared
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single; Multi
Vapor Flammability Analyzer -- PrevEx Model SNR701
from Control Instruments Corp.

The Model SNR701 is an industrial strength assembly consisting of a heated flame cell and an integrated controller that continuously measures total flammable vapor concentrations from 0 to 100% of the Lower Flammable Limit (LFL) range. Optional modifications allow the SNR701 to sample low oxygen and... [See More]

  • Application: Ambient Air Monitoring; Process Gas
  • Analyzer Technology: Flame temperature sensor
  • Mounting Type: Fixed
  • Number of Gases Monitored: Multi
Carbon Monoxide (CO) Analyzer -- Model CCO 5500
from Emerson Automation Solutions – Rosemount

The CCO 5500 Carbon Monoxide (CO) Analyzer uses infrared absorption spectroscopy to continuously measure CO concentration in combustion flue gases. The infrared source is mounted directly on the flue gas duct or stack on the side opposite from the receiver. Infrared energy is radiated by the source,... [See More]

  • Application: Continuous Emissions Monitoring; Process Gas
  • Analyzer Technology: Infrared
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single
Single Point Gas Monitor -- SPM
from Honeywell Analytics, Inc.

A fast response device detecting down to ppb of toxic gases, providing physical evidence of a gas event. This use-anywhere, fast response monitor is specific to your target gas only. Until now, the big concern with basic units for toxic gas monitoring was that environmental conditions or other... [See More]

  • Application: Ambient Air Monitoring; Process Gas
  • Analyzer Technology: Chemcassette. Pyrolyzer option.
  • Mounting Type: Portable; Fixed
  • Number of Gases Monitored: Single
Analyzer for H2 with CO2 Compensation -- Model 4230
from Nova Analytical Systems Inc.

The Nova 4230 Process Hydrogen Analyzer has been specifically designed for the accurate measurement of H2 in exothermic or 'DX' gas from a furnace, generator, or other processes with high levels of H2 and CO2. The CO2 acts as an interference to the measurement of Hydrogen when using a thermal... [See More]

  • Application: Process Gas
  • Analyzer Technology: Thermal Conductivity Cell
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single
Lonestar Portable Gas Analyzer
from Owlstone Inc.

Lonestar is a portable gas analyzer that can detect a broad range of analytes at part per billion concentrations, with high selectivity in just a few seconds. [See More]

  • Application: Personal Exposure Monitoring; Ambient Air Monitoring; Process Gas
  • Analyzer Technology: PID
  • Mounting Type: Portable
  • Number of Gases Monitored: Multi
Gas Analyzer/Biogas/Handheld/Infrared -- Gasboard 3200 plus
from Cubic Sensor and Instrument Co.,Ltd.

Handheld biogas analyzer Gasboard-3200Plus is handheld type analyzer, mainly used for measuring biogas compositions of CH4, CO2, O2, H2S and optional H2, CO gases, with high accuracy, stable performance and easy carrying features, widely used in anaerobic digestion biogas, waste water treatment... [See More]

  • Application: Process Gas
  • Analyzer Technology: Electrochemical; Infrared
  • Mounting Type: Handheld; Portable
  • Number of Gases Monitored: Multi
COSA CHA Continuous Hydrogen Analyzer
from COSA Xentaur Corporation

The COSA/Xentaur Continuous Hydrogen Analyzer (CHA), used in countless UOP Schedule A applications for many years, is built under a license to a patented UOP design. It provides petroleum refiners, petrochemical producers, and electric power generators a means to continuously and accurately monitor... [See More]

  • Application: Process Gas
  • Analyzer Technology: Electrochemical
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single
Gas Analyzer -- FI-800
from RKI Instruments, Inc.

Long life light source, no reference gas required, continuous measurement [See More]

  • Application: Process Gas
  • Analyzer Technology: Optical Interferometric
  • Mounting Type: Fixed
  • Number of Gases Monitored: Multi
Generator Gas Analyzer -- GGA
from Environment One Corporation

E/One's Generator Gas Analyzer (GGA) for hydrogen-cooled generators is a triple-range sensor/analyzer that provides continuous monitoring of gas purity during all phases of generator operation. We've taken a proven monitoring principle — thermal conductivity — and improved upon it. The... [See More]

  • Application: Process Gas
  • Analyzer Technology: Thermoconductivity
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single
Compressed Breathing Air Analysis Kit -- 7015406
from Sensidyne, LP

The Sensidyne Compressed Breathing Air (CBA) Analysis Kit allows anyone to simply, quickly, and quantitatively measure all four of the common contaminants in breathing air, plus oxygen defeciency. [See More]

  • Application: Personal Exposure Monitoring; Confined Space Entry; Continuous Emissions Monitoring; Ambient Air Monitoring; Process Gas
  • Number of Gases Monitored: Single
  • Mounting Type: Portable
  • Measurement Type: %Volume (optional feature); Trace (optional feature)
CH Transmitter -- CH-Trans
from Roscid Technologies

The Model CH-Trans is simple, accurate and. very simple to use in measuring the % levels of hydro carbons. three wire hydrocarbon transmitter. The Model CH-Trans is simple, accurate and very simple to use in measuring the % levels of hydro carbons. One User specific measuring range. The unit offers... [See More]

  • Application: Process Gas
  • Number of Gases Monitored: Multi
  • Analyzer Technology: Infrared
  • Measurement Type: %Volume
High Temperature Oxygen Analyzer -- 5081FG
from Emerson Automation Solutions – Rosemount

Traditional in situ oxygen flue gas analyzers utilize zirconium oxide sensors to measure excess oxygen in process flue gas. These zirconium oxide sensors use a principle of operation based on the Nernst equation. This principle requires that the sensor cell be maintained at a high operating... [See More]

  • Application: Process Gas
  • Analyzer Technology: Zirconium Oxide Sensing Element
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single
Analyzers for Landfill Site -- Model 900A
from Nova Analytical Systems Inc.

The Nova 900 Series analyzers have been designed for monitoring recovered and processed gases from landfill and biogas sites. This equipment continuously removes moisture from the wet sample gas without the need for cooling water, compressed air, or failure-prone thermoelectric elements. The 900... [See More]

  • Application: Process Gas
  • Analyzer Technology: Electrochemical (optional feature); Infrared (optional feature)
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single
Gas Analyzer/Biogas/Online/Infrared -- Gasboard 3200
from Cubic Sensor and Instrument Co.,Ltd.

Online biogas analyzer Gasboard-3200 is a rack type analyzer, mainly used for measuring biogas compositions of CH4, CO2, O2, H2S with high accuracy, stable performance, can be easily integrated with biogas analysis system, widely used in anaerobic digestion biogas, waste water treatment biogas,... [See More]

  • Application: Process Gas
  • Analyzer Technology: Electrochemical; Infrared
  • Mounting Type: Fixed
  • Number of Gases Monitored: Multi
Portable Gas Analyzer -- PGA
from Environment One Corporation

Environment One's standard Generator Gas Analyzer (GGA) can also be supplied in a portable configuration. The PGA incorporates the same hydrogen gas sensor/analyzer and system electronics found in our other hydrogen gas purity systems. The PGA is specifically intended for use in non-hazardous... [See More]

  • Application: Process Gas
  • Analyzer Technology: Thermoconductivity
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single
Hydrogen Transmitter -- H2Trans
from Roscid Technologies

The Model H2Trans is simple, accurate and economic measurement of Hydrogen at trace and % levels. A simple Display and one point calibration allow easy and fast start-up of the instrument. Optional 1/2 G Ex ia IIC T4 (ATEX). Specifications. Measuring range. ppm : 100 – 100000 ppm H2. [See More]

  • Application: Process Gas
  • Number of Gases Monitored: Single
  • Analyzer Technology: Electrochemical
  • Measurement Type: Trace
In Situ Oxygen Analyzer -- 6888
from Emerson Automation Solutions – Rosemount

Rosemount Analytical is the leader in oxygen flue gas analyzer technology. The 6888 continues the tradition of integrating an oxygen probe and field electronics into a single, compact package. The probe inserts directly into a flue gas duct to measure oxygen in combustion processes. No sampling... [See More]

  • Application: Process Gas
  • Analyzer Technology: Zirconium Oxide Sensing Element
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single
Blast Furnace Top Gas Analyzer -- Model 8000
from Nova Analytical Systems Inc.

The Nova 8000 series has been designed for the continuous monitoring of pre-cleaned gases from a blast furnace or other high intensity, continuous industrial processes. The analyzer measures up to four gases simultaneously - O2, CO, CO2, and H2, the ranges of which are shown below. From these... [See More]

  • Application: Continuous Emissions Monitoring; Process Gas
  • Analyzer Technology: Electrochemical (optional feature); Infrared (optional feature); Thermal Conductivity Cell
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single
Gas Analyzer/Biogas/Portable/Infrared -- Gasboard 3200L
from Cubic Sensor and Instrument Co.,Ltd.

Portable biogas analyzer Gasboard-3200L is a portable type analyzer, mainly used for measuring biogas compositions of CH4, CO2, O2, H2S, with high accuracy, stable performance and easy carrying features, widely use in anaerobic digestion biogas, waste water treatment biogas, landfill site,... [See More]

  • Application: Process Gas
  • Analyzer Technology: Electrochemical; Infrared
  • Mounting Type: Portable
  • Number of Gases Monitored: Multi
M-Oxygen Transmitter -- O2Tracer-M
from Roscid Technologies

The Model O2Tracer-M is simple to use, accurate and very economical. Features. Oxygen Transmitter with a display. 4 – 20 mA Loop Powered two wire. Two Wire Process Oxygen analyzer. Calibration : performed at Ambient O2. Accuracy : +/- 2% FSD T= const. +/- 5% FSD 0 >T >50 °C. Response... [See More]

  • Application: Process Gas
  • Number of Gases Monitored: Single
  • Analyzer Technology: Electrochemical
  • Measurement Type: %Volume
MLT, CLD and FID Multi-Component and Multi-Method Analyzers and Analyzer Systems -- MLT 1 Multi-Component Gas Analyzer
from Emerson Automation Solutions – Rosemount

Rosemount Analytical ’s MLT, CLD and FID series of analyzers offer MLT with multi-component, multi-method analysis utilizing non-dispersive infrared, visible, ultraviolet (NDIR/UV/VIS), thermal conductivity (TCD), paramagnetic, and electrochemical sensor technologies (pO2/eO2), trace oxygen... [See More]

  • Application: Process Gas
  • Analyzer Technology: Electrochemical; Infrared; PID; Paramagnetic, Thermal Conductivity
  • Mounting Type: Fixed
  • Number of Gases Monitored: Multi
Continuous Flue Gas Analyzer -- Model 7200
from Nova Analytical Systems Inc.

The Nova Model 7200-1-F1 flue gas analyzer is specifically designed for use on the flue gases from combustion processes burning gaseous fuels.Sample Gas is drawn into the analyzer from the sampling probe, then pumped through a condensate removal system. Any condensate formed collects and is purged... [See More]

  • Application: Continuous Emissions Monitoring; Process Gas
  • Analyzer Technology: Catalytic (optional feature); Electrochemical (optional feature); Infrared (optional feature); Zirconia, Para-Magnetic
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single
Gas Analyzer/Combustion/Process/Portable/Infrared -- Gasboard-3400P
from Cubic Sensor and Instrument Co.,Ltd.

Combustion analyzers are available for HVAC, boiler, industrial and flue gas monitoring applications. A wide range of units is available, with most offering CO2, CO, O2 with advanced NDIR and long life time ECD technology. A new portable type in reliable and accurate combustion analysis with its... [See More]

  • Application: Process Gas
  • Analyzer Technology: Electrochemical; Infrared
  • Mounting Type: Portable
  • Number of Gases Monitored: Multi
OEM Oxygen Analyzer -- OxyTrans LC OEM
from Roscid Technologies

4 – 20 mA Loop Powered two wire Oxygen Transmitter. Two Wire Process Oxygen analyzer. The Model OxyTrans LC is simple, accurate and economic measurement of Oxygen at trace (ppm) levels and % levels. Four User Specific Measuring Range Offered. The OxyTrans LC is offered in 4 different measuring... [See More]

  • Application: Process Gas
  • Number of Gases Monitored: Single
  • Analyzer Technology: Electrochemical
  • Measurement Type: %Volume; Trace
MLT, CLD and FID Multi-Component and Multi-Method Analyzers and Analyzer Systems -- MLT 2 Multi-Component Gas Analyzer
from Emerson Automation Solutions – Rosemount

Rosemount Analytical ’s MLT, CLD and FID series of analyzers offer MLT with multi-component, multi-method analysis utilizing non-dispersive infrared, visible, ultraviolet (NDIR/UV/VIS), thermal conductivity (TCD), paramagnetic, and electrochemical sensor technologies (pO2/eO2), trace oxygen... [See More]

  • Application: Process Gas
  • Analyzer Technology: Electrochemical; Infrared; PID; Paramagnetic, Thermal Conductivity
  • Mounting Type: Fixed
  • Number of Gases Monitored: Multi
Heat Treat & Industrial Process Analyzer -- Model 7900
from Nova Analytical Systems Inc.

The Nova 7900 Series Heat Treat Analyzer System utilizes high stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long life thermal conductivity cell for hydrogen that is compensated for the... [See More]

  • Application: Process Gas
  • Analyzer Technology: Electrochemical (optional feature); Infrared (optional feature); Thermal Conductivity Cell
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single
Gas Analyzer/Laser Raman -- LRGA-6000
from Cubic Sensor and Instrument Co.,Ltd.

Laser raman gas analyze?r LRGA-6000 is an advanced equipment that can online measure all the gas composition of most fuel gases, including biogas, syngas, natural gas, producer gas and so on. And with the unique advantages of no consumables, higher accuracy, long lifetime, and no routine calibration... [See More]

  • Application: Process Gas
  • Analyzer Technology: Laser Raman
  • Mounting Type: Fixed
  • Number of Gases Monitored: Multi
Oxygen Analyzer -- O2 Tracer
from Roscid Technologies

The Model O2Tracer is simple, accurate and very economic measurement of Oxygen at % levels. One User specific measuring range. the unit will offer with different ranges between 0 – 100% of oxygen. Typical range is 0- 25%. Sensor. The O2Tracer uses a special fuel cell to measure the oxygen... [See More]

  • Application: Process Gas
  • Number of Gases Monitored: Single
  • Analyzer Technology: Electrochemical
  • Measurement Type: %Volume
MLT, CLD and FID Multi-Component and Multi-Method Analyzers and Analyzer Systems -- MLT 3 with Internal Power Supply
from Emerson Automation Solutions – Rosemount

Rosemount Analytical ’s MLT, CLD and FID series of analyzers offer MLT with multi-component, multi-method analysis utilizing non-dispersive infrared, visible, ultraviolet (NDIR/UV/VIS), thermal conductivity (TCD), paramagnetic, and electrochemical sensor technologies (pO2/eO2), trace oxygen... [See More]

  • Application: Process Gas
  • Analyzer Technology: Electrochemical; Infrared; PID; Paramagnetic, Thermal Conductivity
  • Mounting Type: Fixed
  • Number of Gases Monitored: Multi
Heat Treating & H2 Processes Analyzer -- Model 7900P-3A
from Nova Analytical Systems Inc.

The Nova Model 7900P Series Heat Treat analyzers utilize a three channel high stability infrared detector for the simultaneous measurement of CO, CO2, and CH4 in exothermic or endothermic gas mixtures. In addition, the analyzer can be supplied with a fully compensated thermal conductivity cell for... [See More]

  • Application: Process Gas
  • Analyzer Technology: Electrochemical; Infrared
  • Mounting Type: Portable
  • Number of Gases Monitored: Single
Gas Analyzer/Natural gas/Portable/Infrared -- Gasboard-3110P
from Cubic Sensor and Instrument Co.,Ltd.

Portable natural gas analyzer Gasboard-3110P is a portable type analyzer and the best alternative of GC and MS that can be used for online measurement for natural gas composition and heating value second by second. It is widely used in various applications such as natural gas, coal bed methane, SNG,... [See More]

  • Application: Process Gas
  • Analyzer Technology: Infrared
  • Mounting Type: Portable
  • Number of Gases Monitored: Multi
Oxygen Analyzer -- OxyTrans II
from Roscid Technologies

Two Wire Process Oxygen Analyser. The Model OxyTrans is simple, accurate and an economical way to measure traces and % ranges of Oxygen. The unit has a simple display and offers a one point calibration allowing for a quick start up. optional 1/2 G Ex ia IIC T4 (ATEX). Specific Measuring Range. There... [See More]

  • Application: Process Gas
  • Number of Gases Monitored: Single
  • Analyzer Technology: Electrochemical
  • Measurement Type: %Volume; Trace
MLT, CLD and FID Multi-Component and Multi-Method Analyzers and Analyzer Systems -- MLT 4 Multi-Component Gas Analyzer
from Emerson Automation Solutions – Rosemount

Rosemount Analytical ’s MLT, CLD and FID series of analyzers offer MLT with multi-component, multi-method analysis utilizing non-dispersive infrared, visible, ultraviolet (NDIR/UV/VIS), thermal conductivity (TCD), paramagnetic, and electrochemical sensor technologies (pO2/eO2), trace oxygen... [See More]

  • Application: Process Gas
  • Analyzer Technology: Electrochemical; Infrared; PID; Paramagnetic, Thermal Conductivity
  • Mounting Type: Fixed
  • Number of Gases Monitored: Multi
Process Analyzer for H2 & Dew Point -- Model 430DPL-N4
from Nova Analytical Systems Inc.

The Nova 430DPL analyzer utilizes a temperature-controlled T/C cell for the detection of H2 in process gas. This cell produces a small millivoltage output which is directly proportional to the H2 detected. This output is then amplified and displayed on a digital readout meter and is also available... [See More]

  • Application: Process Gas
  • Analyzer Technology: Thermal Conductivity Cell
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single
Gas Analyzer/Syngas/Online/Infrared -- Gasboard-3100
from Cubic Sensor and Instrument Co.,Ltd.

Online syngas analyzer Gasboard-3100 is a stationary analyzer with standard 19'' 3U rack enclosure, easy to be integrated inside industrial system. It is able to online continuously measure volume concentration of CO, CO2, CH4, H2 , O2 , CnHm, C2H2 , C2H4 simultaneously, and calculate gas heating... [See More]

  • Application: Process Gas
  • Analyzer Technology: Electrochemical; Infrared
  • Mounting Type: Fixed
  • Number of Gases Monitored: Multi
Oxygen Analyzer for Glovebox -- OxyTrans
from Roscid Technologies

The Model OxyTrans is simple, accurate and Economic measurement of Oxygen at trace and % levels. A simple Display and one point calibration allow easy and fast start-up of the instrument. Features. Measuring ranges. ppm: 0-10, 0 – 100; 0 – 1000;. : 0 – 10000 ppm O2. : 0 – 25;... [See More]

  • Application: Process Gas
  • Number of Gases Monitored: Single
  • Analyzer Technology: Electrochemical
  • Measurement Type: %Volume; Trace
Oxygen and Combustibles Transmitter -- OCX 8800
from Emerson Automation Solutions – Rosemount

The OCX 8800 with its rugged design, stable sensor, electronics and software package, is the most dependable oxygen/combustibles transmitter on the market. The time-tested and world renowned zirconium oxide sensor is the basis for the oxygen measurement. This, coupled with the new combustibles... [See More]

  • Application: Process Gas
  • Analyzer Technology: Zirconium Oxide Sensing Element
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single
Process Analyzer for Methane -- Model 470N4
from Nova Analytical Systems Inc.

The Nova 470 Series CH4 analyzers utilize a simple and reliable microprocessor-based non-dispersive infrared detector specific to CH4. The detector pulses an infrared beam of light through the sample tube, without the need for a mechanical chopper. In operation, the internal sample pump draws the... [See More]

  • Application: Process Gas
  • Analyzer Technology: Infrared
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single
Gas Analyzer/Syngas/Portable/Infrared -- Gasboard-3100P
from Cubic Sensor and Instrument Co.,Ltd.

Portable syngas analyzer Gasboard-3100P is a portable type analyzer used for syngas composition analysis. It is widely used in various applications such as biomass gasification, coal gasification, waste to energy, RDF, methane conversion, blast furnace top gas, coke gas, ENDO & EXO gas and so on. [See More]

  • Application: Process Gas
  • Analyzer Technology: Infrared
  • Mounting Type: Portable
  • Number of Gases Monitored: Multi
Oxygen and Water Dual Analyzer -- Oxymaster 16TW
from Roscid Technologies

The Model Oxymaster is made for fast, accurate and economic measurement of Oxygen at trace levels. A simple menu-driven software, touch pad and large LCD-display allow easy and fast start-up of the Oxymaster instrument. Specifications. Measuring range: 0 – 8000 ppb O2. free programmable lowest... [See More]

  • Application: Process Gas
  • Analyzer Technology: Variety of Sensors Available
  • Mounting Type: Fixed
  • Number of Gases Monitored: Single