Digital Front Panel Oxidation Reduction Potential (ORP) Instruments
from PCE Instruments / PCE Americas Inc.
PCE-228 Water Analysis Meter. Measures pH, redox and temperature /. SD memory card (1 ... 16 GB), measured values are stored in an Excel file /. Large display / RS-232 interface and optional PC software The PCE-228 water analysis meter is an easy-to-use handheld device for measuring pH, mV and... [See More]
- User Controls: Digital Front Panel; Computer Interface
- Measures pH: Yes
- ORP Range: -1999 to 1999
- pH range: 0.0 to 14
from ABB Measurement & Analytics
Overview. The AWT210 offers the power of advanced digital communications in a simple, flexible design, enabling you to get up and running quickly. 'Easy Setup' sensor configuration menus provide step-by-step guidance. Advanced self-diagnostics conforming to NAMUR NE 107 provide harmonized indication... [See More]
- User Controls: Digital Front Panel
- Measures pH: Yes
- ORP Range: -1500 to 1500
- pH range: 0.0 to 14
from Myron L Company
Definitive Dialysate Testing. The DIGITAL DIALYSATE METER is specifically designed to test both acetate and bicarbonate dialysate quality. Measure Conductivity, pH and Temperature to ensure proper mixing during dialysate preparation and as a final check of dialysate quality before hemodialysis... [See More]
- User Controls: Digital Front Panel
- Accuracy: -1 to 1
- ORP Range: -999 to 999
- Features: ORP Reference Electrode Input
from PCE Instruments / PCE Americas Inc.
PCE-228-R Water Analysis Meter. Portable Redox Meter, for both pH and temperature values. with RS-232 interface and optional software The PCE-288-R Water Analysis Meter or Redox Meter is a very easy to use meter to measure mV / pH / ºC. In the PCE-228-R Redox Meter, values can be directly... [See More]
- User Controls: Digital Front Panel; Computer Interface
- Measures pH: Yes (optional feature)
- ORP Range: -1999 to 1999
- pH range: 0.0 to 14
from ABB Measurement & Analytics
AX400 Analyzers incorporate the latest technology providing highly reliable, flexible, feature-packed devices that satisfy a diverse range of process monitoring and control applications. The complete range encompasses solutions for pH/Redox (ORP), conductivity and dissolved oxygen. AX48x instruments... [See More]
- User Controls: Digital Front Panel
- Features: ORP Reference Electrode Input
- ORP Range: -1200 to 1200
- Measures pH: Yes
from Myron L Company
bull; FAST one-touch measurements for Conductivity, Mineral/Salt Concentration, TDS, ORP (REDOX), Free Chlorine, pH and Temperature. • SIMPLE user-intuitive prompts step you through Alkalinity, Hardness and LSI titrations (PS9). • CONVENIENT LSI Calculator accepts both grains and ppm... [See More]
- User Controls: Digital Front Panel
- Accuracy: -1 to 1
- ORP Range: -999 to 999
- Features: ORP Reference Electrode Input
from ABB Measurement & Analytics
ABB's Endura family of 24 VDC analytical transmitters are designed for the requirements of industrial customers and are used in measurement and control applications within a broad range of applications including chemical, pulp & paper, mining and petroleum refining. The APA592 transmitter is... [See More]
- User Controls: Digital Front Panel
- Accuracy: 1
- ORP Range: -1500 to 1500
- Measures pH: Yes
from Myron L Company
NEW! FCE FAC Readings. The Myron L ® Company FCE function reports FAC quickly and accurately by measuring ORP, the chemical characteristic of chlorine that directly reflects its effectivity, cross referenced with pH. Both DPD kits and colorimeters may tell the user the FAC value of the sample in... [See More]
- User Controls: Digital Front Panel
- Features: ORP Reference Electrode Input
- ORP Range: -999 to 999
- Measures pH: Yes
from ABB Measurement & Analytics
The AWT420 transmitter can be used with either analog or digital EZLink sensors for a wide range of applications including drinking water, wastewater, industrial water and power. Operation simplicity is a key feature of the AWT420 with its powerful, yet intuitive software, advanced self-diagnostics... [See More]
- User Controls: Digital Front Panel
- Form Factor: Panel
- Measures pH: Yes
- Display Type: Video
from Myron L Company
NEW! FCE FAC Function. The Myron L ® Company FCE function reports FAC quickly and accurately by measuring ORP, the chemical characteristic of chlorine that directly reflects its effectivity, cross referenced with pH. Both DPD kits and colorimeters may tell the user the FAC value of the sample in... [See More]
- User Controls: Digital Front Panel
- Accuracy: -1 to 1
- ORP Range: -999 to 999
- Features: ORP Reference Electrode Input
from Amprobe Test Tools
Help control the costs and risks of maintaining water quality, distribution and waste. Amprobe makes a full line of meters to test pH, conductivity, TDS, salinity, mV, and dissolved oxygen. [See More]
- User Controls: Digital Front Panel
- Measures pH: Yes (optional feature)
- ORP Range: -1999 to 1999
- pH range: 0.0 to 14
from Lovibond® Tintometer®
The SensoDirect 150 is designed for multi purpose operation and measures pH/Redox, dissolved oxygen and conductivity/TDS. It incorporates an intuitive user interface, large, easy to read display and is supplied with a sturdy handy case with electrodes, buffer solution and accessories. Highlights. [See More]
- User Controls: Digital Front Panel
- Measures pH: Yes
- ORP Range: -1999 to 1999
- pH range: 0.0 to 14
from Sartorius Lab Instruments GmbH & Co. KG
Sartorius Professional Meters – For professional measurements and optimal testing in laboratories. Easy to operate with the highest measurement accuracy – also for data management. Automatic buffer recognition. Automatic temperature compensation. Automatic electrode function check. [See More]
- User Controls: Digital Front Panel
- pH range: -2 to 16
- Measures pH: Yes
- Accuracy: 0.0020
from KPM Analytics
Multi-Probe pH Data Logging and Analysis of Lactic Acid Bacteria (LAB) Associated with Cultures and Fermented Foods. The iCinac analyzer is the only solution designed specifically to monitor and analyze the acidification activity of lactic ferments in starter, functional, bio-protective, and... [See More]
- User Controls: Digital Front Panel
- pH Measurement Features: Temperature Measurement
- Measures pH: Yes
- Form Factor: Portable
from Emerson Automation Solutions – Rosemount
The Model 56 Analyzer offers single or dual sensor input with an unrestricted choice of dual measurement combinations. The high resolution full-color display gives unsurpassed visibility and functionality for liquid analytical instrumentation. High resolution full-color screen: easily viewed process... [See More]
- User Controls: Digital Front Panel
- Accuracy: 1
- ORP Range: -1500 to 1500
- Measures pH: Yes
from SWAN Analytical USA, INC.
Electronic transmitter/controller for wall mounting. Measuring and control transmitter for field installation in aluminum box (IP 66). Dimensions: 180 x 140 x 70 mm. Connections: 2 signal outputs for measured values or continuous control, 2 relays as limit switches or as controllers, 1 alarm relay... [See More]
- User Controls: Digital Front Panel
- Accuracy: -1 to 1
- ORP Range: -500 to 1500
- Features: ORP Reference Electrode Input
from OMEGA Engineering, Inc.
The PHH-128 indicator combines 5 meters into one easy-to-use wall mounting continuous monitor, featuring a large, duallevel, backlit LCD display. This meter can display the EC/TDS/CF (conductivity factor) of your solution together with the choice of either pH (probe sold separately), or... [See More]
- User Controls: Digital Front Panel
- Features: ORP Reference Electrode Input
- ORP Range: 0 to 1999
- Measures pH: Yes
from REED-Direct
High input impedance. Data Hold function. Includes batteries. Probe sold separately [See More]
- User Controls: Digital Front Panel
- Form Factor: Hand Held
- ORP Range: -1999 to 1999
- Display Type: Digital
from Lovibond® Tintometer®
SensoDirect pH200. pH / redox measurement and temperature measurement (Pt1000 or NTC 30kOhm). Automatic temperature compensation (ATC). Auto Hold function. Internal memory for 20 data sets. Automatic buffer recognition with Tintometer standard or DIN or individual buffer. 1, 2 and 3 point... [See More]
- User Controls: Digital Front Panel
- Accuracy: 0.1000
- ORP Range: -1999 to 2000
- Measures pH: Yes
from Emerson Automation Solutions – Rosemount
The Model 1056 dual-input analyzer offers single or dual sensor input with an unrestricted choice of dual measurements thus reducing the cost per loop and saving panel space. The unit has a choice of HART and Profibus DP digital communications. It features a large back-lit display that has... [See More]
- User Controls: Digital Front Panel
- Accuracy: 1
- ORP Range: -1500 to 1500
- Measures pH: Yes
from SWAN Analytical USA, INC.
Electronic transmitter/controller for panel insertion. Measuring and control transmitter for panel installation in a Noryl ® resin enclosure (IP 54). Dimensions: 96 x 96 x 120 mm. Connections: 2 signal outputs for measured values or continuous control, 2 relays as limit switches or as... [See More]
- User Controls: Digital Front Panel
- Features: ORP Reference Electrode Input
- ORP Range: -500 to 1500
- Measures pH: Yes
from OMEGA Engineering, Inc.
The 6-in-1 PHH-126 meter was designed with a built-in rechargeable battery. The built-in battery can last approximately 3 years, with standard charging time of approximately 2 hours. The PHH-126 can measure 4 parameters including pH (probe sold separately), temperature, conductivity and TDS. This... [See More]
- User Controls: Digital Front Panel
- Measures pH: Yes
- Features: ORP Reference Electrode Input
- pH range: 0.0 to 14
from Emerson Automation Solutions – Rosemount
MULTI-PARAMETER INSTRUMENT – up to three inputs: Choose pH/ORP/ISE or Contacting Conductivity/Resistivity, in any combination. LARGE DISPLAY – easy-to-read process measurements. EASY TO INSTALL – modular boards, removable connectors, easy to wire power, sensors and outputs. [See More]
- User Controls: Digital Front Panel
- Accuracy: 1
- ORP Range: -1500 to 1500
- Features: ORP Reference Electrode Input
from OMEGA Engineering, Inc.
An upgraded version of our PHH-126, the PHH-127 has been designed to bring you the most advanced and most functional water tester in the market today. The PHH-127 has a built-in rechargeable battery with wall plug charger with a standard charging time of approximately 2 hours. It can measure 5... [See More]
- User Controls: Digital Front Panel
- Features: ORP Reference Electrode Input
- ORP Range: 0 to 1999
- Measures pH: Yes
from Emerson Automation Solutions – Rosemount
The Model 1066 loop-powered transmitter measures pH, ORP, conductivity, resistivity, oxygen, free chlorine, total chlorine, monochloramine and ozone serving a wide range of liquid analytical applications. Digital communications – HART ® version 7 and FOUNDATION ® fieldbus communication... [See More]
- User Controls: Digital Front Panel
- Accuracy: 1
- ORP Range: -1400 to 1400
- Measures pH: Yes
from OMEGA Engineering, Inc.
The Model PHB-357 microprocessor-based, benchtop meter brings very accurate pH and mV measurements to the laboratory. Useful design features include automatic buffer recognition, automatic calibration, recorder output for permanent recordkeeping, splashproof keypad to prevent damage from spills,... [See More]
- User Controls: Digital Front Panel
- Measures pH: Yes
- ORP Range: -2000 to 2000
- pH range: 0.0 to 14